| 1 | Supply , laying , testing & Commissioning UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm, 4 core, some cable shell be laid at new place with Suitable thimbles complete all as specified and directed by Engr-in-Charge |
| 2 | All as per item No-01 but size 25 sq mm, 4 core complete all as specified by Engineer-in-Charge. |
| 3 | All as per item No-01 but size 50 sq mm, 3.5 core complete all as specified by Engineer-in-Charge. |
| 4 | All as per item No-01 but size 95 sq mm, 3.5 core complete all as specified by Engineer-in-Charge. |
| 5 | All as per item No-01 but size 120 sq mm, 3.5 core complete all as specified by Engineer-in-Charge. |
| 6 | All as per item No-01 but size 185 sq mm, 3.5 core complete all as specified by Engineer-in-Charge. |
| 7 | Dismantling of existing ACSR Conductor of any type complete all as specified and directed by Engineer-in-Charge. |
| 8 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in any type of soil for laying of LT UG cables complete all as specified by Engineer-in-Charge.Note:- The Rate quoted deemed to including cutting and removal of PSP Sheets wherever occured during excavation and the same shall be staged at desired location as directed at site |
| 9 | Returning, filling in, including spreading levelling, watering and well ramming in layers not exceeding 25 cm thick in hard dense soil complete all as specified by Engineer-in-Charge. |
| 10 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified by Engineer-in-Charge. |
| 11 | M&L Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate for foundation of poles including formwork complete all as specified by Engineer-in-Charge. |
| 12 | M & L Plain Cement Concrete 1:3:6 type nominal mix C1 using 20 mm graded stone aggregate for coping of poles/road/plinth blocks of LT poles etc including fair finishing the exposed surfaces even and smooth without using extra cement including necessary form work complete all as specified by Engineer-in-Charge. |
| 13 | Supply and laying of DWC (Double Wall Corrugated) HDPE Pipe, ISI Marked IS 16205 Part-II, of outer dia of 63 mm and inner dia 50 mm with smooth internal and profiled external surface for non pressure under ground cable including all connected accessories like coupler, 'O' Ring etc, for protection of cable complete all as specified by Engineer-in-Charge. |
| 14 | Supply and laying of DWC (Double Wall Corrugated) HDPE Pipe, ISI Marked IS 16205 Part-II, of outer dia of 77 mm and inner dia 63 mm with smooth internal and profiled external surface for non pressure under ground cable including all connected accessories like coupler, 'O' Ring etc, for protection of cable complete all as specified by Engineer-in-Charge. |
| 15 | Material and labour for Double Walled Corrugated (DWC) HDPE pipe of 120 X 103.5 mm bore (OD x ID) with coupler confirming IS 16205 Part-24-2018 for LT UG cable protection complete all as specified and directed by Engineer- in- charge. |
| 16 | M & L for Cutting through existing road surfaces i.e. surfacing PCC soling etc, and making trench of minimum 500mm wide 100cm in depth along the cross section of road for laying of pipes or UG cables, including returning filing in, well ramming & removal of surplus spoil to a distance not exc. 50 mtrs & repairs to road surfaces to match with existing specification after laying the pipes/cable etc complete all as specified by Engineer-in-Charge. |
| 17 | S & F cable route indicator made out of 25 x25 x 4 mm angle iron, 300 mm long embedded in PCC block of suitable size with moulded lettter LT CABLE suitably incribed on CI circular plate 6 mm thick 60mm dia complete incl neccessary PCC 1:3:6, type C-2 (using 40 mm graded aggregate) block of suitable size and neccessary earth work and excavation complete all as specified by Engineer-in-Charge. |
| 18 | Supply only Aluminium thimbles for essential services replacement suitable for under ground LT cables of following sizes including cutting of exsting burn/dammaged cable after disconnecting from exsting position ,extending the cable from cable loop including neccesory earth work and reconnecting the same of Size of 35 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 19 | All as per Item No.18 but for 50 Sqmm capacity cable complete all as specified and directed by Engineer-in-Charge. |
| 20 | All as per Item No. 18 but of 70 Sqmm capacity complete all as specified and directed by Engineer-in-Charge. |
| 21 | All as per Item No. 18 but of 95 Sqmm capacity complete all as specified and directed by Engineer-in-Charge. |
| 22 | All as per Item No. 18 but of 120 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 23 | All as per Item No. 18 but of 185 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 24 | Supply & Fixing PVC insulated sheathed service wire twin core 6 Sqmm aluminium solid conductor 1100 volts grade including taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge. |
| 25 | Supply & Fixing PVC insulated sheathed service wire twin core 10 Sqmm aluminium solid conductor 1100 volts grade including taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge. |
| 26 | Supply and Fixing Change Over Switchs ON-Load 200 Amps 4 pole front operator Sheet metal encloser complete all as specified and directed by Engineer-in-Charge. |
| 27 | Supply and Fixing Change Over Switchs ON-Load 100 Amps 4 pole front operator Sheet metal encloser complete all as specified and directed by Engineer-in-Charge. |
| 28 | Supply and Fixing in repairs MCCB 250 Amps 4 pole 25 KA with adjustable thermal and adjustable magnetic setting,complete all as specified and directed by Engineer-in-Charge. |
| 29 | Supply and Fixing in repair MCCB 200 Amps 4 pole 25 KA with Sheet metal encloser with adjustable thermal and adjustable magnetic setting,complete all as specified and directed by Engineer-in-Charge. |
| 30 | Supply and Fixing MCCB 160 Amps 4 pole 25 KA adjustable thermal and adjustable magnetic setting, complete all as specified and directed by Engineer-in-Charge. |
| 31 | M&L for Preparation of old painted surface of 9 metre steel tubular poles above the top of PCC coping. Painting of pole from top of coping to a height of 1.5metre (bottom portion of pole) with two coats of synthetic enamel paint in black and yellow alternate strip and painting the rest portion of pole of (approximately length 7 metre)including painting of cross arms/clamps etc complete with two coats of synthetic enamel aluminium paint complete all as specified and directed by Engineer-in-Charge. |
| 32 | M & L for Preparation of old cement based painted surfaces of RCC pole 9 metre by cleaning of deposited materials, and painting with one coat of cement base paint of approved make and colour complete all as specified and directed by Engineer-in-Charge. |
| 33 | M&L for fault detection in damaged UG cables using cable fault detector/locator, vehicle mounted to accuracy of 2m for various locations inside Air Force Stn for UG cables of any size upto 240 Sqmm including excavation & earthwork in any type of strata of size 4x2x0.6m to visually inspect/repair the damaged cable complete all as specified and directed by Engineer-in-Charge. |
| 34 | S & fix LT Cable joining kit straight through heat shrinkabale complete with jointing materials suitable for LT Armoured cable 4 core of size 70 to 120 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 35 | S & fix LT Cable joining kit straight through heat shrinkabale complete with jointing materials suitable for LT Armoured cable 4 core of size 150 to 240 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 36 | S & fix LT Cable end joining kit heat shrinkabale complete with jointing materials suitable for LT Armoured cable 4 core of size 70 to 120 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 37 | S & fix LT Cable end joining kit heat shrinkabale complete with jointing materials suitable for LT Armoured cable 4 core of size 150 to 240 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 38 | Taking out of old unserviceable LT panel board any type including accessories complete all as specified and directed by Engineer-in-Charge. |
| 39 | Supply, install, testing & commissioning of factory made out door LT Panel board of sutiable size for 3 phase 415 volt of both side opening doubl door with push type metal lock, heavy duty wide hinges, seperate common across cable aley, made out 3 mm CRCA sheet with angle iron frame of size (50 x50 x 6 mm) and MC channel of size (75mm x 40mm) for panel base out door type , free standing cubical type totally enclosed weather dust and vermin proof with front and rear opening with locking arrangment of 440 Volts , 3 Phase 4 wire 50 Hz having Alluminium Bus bar of capacity 500 Amps duly insulated with IP 54 protection,with powder coating including PCC foundation complete with following switches, space for 1 No vacant cubical suitable for 32 A, cable alley including LT XLPE cable end terminations with glands and lugs:- Incoming:-i)MCCB 4 Pole ,200 A, 25KA adjustable type , 415 volts rating with terminal spreader - 1 No .ii) Multifunction LED meter complete with CT coil including set of indicating lamp RYB -1 setBus - Bar 400 Amps capacity Aluminium bus bar with sleeves. -4 Nos Out going -i) MCCB, 4 pole, 25 KA ,fixed type, 415 volts 200 Amps rating with terminal spreader .- 1 No .ii) MCCB, 4 pole, 25 KA ,fixed type, 415 volts 63 Amps rating with terminal spreader .- 9 No . |
| 40 | M & L for earthing complete with galvanized steel earth plate electrode 60 x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 metre deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead galvanised iron strip 25×4mm by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to panel and protected by galvanised iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of 2009 complete all as specified and directed by Engineer-in-Charge.. Note : RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover. |
| 41 | M & L for repairing of LT Panel doors ,hinged nut,bolts, clamps duly Welding and fabrication as required for one panel complete all as specified and directed by Engineer-in-Charge. |
| 42 | Supply & Fixing in repair Digital 3 phase Voltmeter class 1 flush mounting of Size 96x96 mm Suitable for 240 voltage complete all as specified and directed by Engineer-in-Charge. |
| 43 | Supply & Fixing in repair Digital 3 phase Ammeter 5A class 1 flush mounting of Size 96x96 mm Suitable for 440 voltage with selector switch in LT panel and DG set LT panel complete all as directed by Engr-in- Charge. Please Enable Macros to View BoQ information |
| 44 | Supply & Fixing in repair Digital 3 phase Ammeter 5A class 1 flush mounting of Size 96x96 mm Suitable for 440 voltage with selector switch in LT panel and DG set LT panel complete all as directed by Engr-in- Charge. Please Enable Macros to View BoQ information |