| 1 | Excavation in trenches in hard / dense soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide and getting out including trimming of sides, for laying of cables & foundation of poles, stay assembly, complete all as specified and directed by Engr-in-Charge. |
| 2 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed by Engr-in-Charge. |
| 3 | Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point, complete all as specified and directed by Engr-in-Charge. |
| 4 | Taking out old unserviceable/serviceable un-reinforced concrete PCC cable covers from excavated trench all as directed by the Engineer-in-Charge. Note:- Serviceable un-reinforced concrete PCC cable cover kept in safe custody for reuse at site and unserviceable un-reinforced concrete PCC cable cover through in low lying area. |
| 5 | M&L for factory made un-reinforced pre cast concrete cable protection cover LV class type - I with size 250mm x 150mm x 40mm laid across the cable (i.e. width of cover along the length of cable) for UG cable protection on the top of the sand cushioning, complete all as specified and directed by Engr-in-Charge. |
| 6 | M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 10cm after laying of cable in trenches complete all as directed and sand cover to UG cable, complete all as specified and directed by Engr-in-Charge. |
| 7 | Supply, laying, testing and commissioning of LT UG cable XLPE insulated PVC sheathed galvanized steel strip armoured electric power cable with stranded aluminium conductor 1100 volts grade confirming to IS:7098 (Part-I), suitable for earthed system, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles & screws etc and making connection, complete all as directed. |
| 8 | Description all as per items No. 07.00 here-in-before but for 10 sq mm 2 core |
| 9 | Description all as per items No. 07.00 here-in-before but for16 Sqmm 2 Core |
| 10 | Description all as per items No. 07.00 here-in-before but for25 Sqmm 3.5 Core |
| 11 | S&F of galvanized iron pipe of 40 mm nominal dia light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wall including painting with two coats of aluminium paint over a coat of red oxide paint, complete all as specified and directed by Engr-in-Charge. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be inclusive in the item rate. |
| 12 | Dismantling and taking down unserviceable / defective street light fitting / Flood light fitting of any wattage alongwith mounting bracket, flat iron clamp, nuts bolts etc from overhead LT poles complete all as specified and directed by Engr-in-Charge. |
| 13 | S&F of LED street light luminaire of 60 Watt capacity, made of single piece pressure die-cast aluminium housing with high power LED with lens for proper light distribution luminiaries, IP 66, with toughned glass cover and incl control gear etc, with and incl making all electric connection, complete all as specified and directed by Engineer in charge. |
| 14 | S&F of LED MCPCB, Single Sided,luminaire of 60 Watt capacity, suitable as per existing sample, IP 66, and incl making all electric connection, complete all as specified and directed by Engineer in charge. |
| 15 | S&F of LED Street Light LED DRIVER 50/60W BIS APROVED, For Flood Light, suitable as per existing sample, IP 66, and incl making all electric connection, complete all as specified and directed by Engineer in charge. |
| 16 | S&F of LED street light luminaire of 90 Watt capacity, made of single piece pressure die-cast aluminium housing with high power LED with lens for proper light distribution luminiaries, IP 66, with toughned glass cover and incl control gear etc, with and incl making all electric connection, complete all as specified and directed by Engineer in charge. Make : Crompton Cat part No LSTN-90-CDL-A |
| 17 | S&F of LED MCPCB, Single Sided,luminaire of 90 Watt capacity, suitable as per existing sample, IP 66, and incl making all electric connection, complete all as specified and directed by Engineer in charge. |
| 18 | S&F of LED Street Light LED DRIVER 90/100W BIS APROVED, For Flood Light, suitable as per existing sample, IP 66, and incl making all electric connection, complete all as specified and directed by Engineer in charge. |
| 19 | S&F in replacement of street light fitting bracket, 1.5 mtr long made out of galvanized iron pipe of 40 mm dia size light grade complete with and incl 02 nos MS clamp made of MS flate iron of 50 x 6 mm size with nut, bolts, washer etc with and incl two coats of aluminum paint over a coat of red oxide primer, complete all as specified and directed by Engr-in-Charge. |
| 20 | S&F of LED flood light luminaire of 200 Watt capacity, 24000 Lumen, made of single piece pressure die-cast aluminium housing with high power LED with lens for proper light distribution luminiaries, IP 66, with toughned glass cover and incl control gear etc, with and incl making all electric connection, complete all as specified and directed by Engineer in charge. |
| 21 | S&F of LED flood light luminaire of 150 W 6500K Cool Day White, made of single piece pressure die-cast aluminium housing with high power LED with lens for proper light distribution luminiaries, IP 66, with toughned glass cover and incl control gear etc, with and incl making all electric connection, complete all as specified and directed by Engineer in charge. |
| 22 | S&F of LED flood light luminaire of 100 Watt capacity, 6500 Lumen, made of single piece pressure die-cast aluminium housing with high power LED with lens for proper light distribution luminiaries, IP 66, with toughned glass cover and incl control gear etc, with and incl making all electric connection, complete all as specified and directed by Engineer in charge. |
| 23 | S&F LED 5 W Spike Light IP65 Warm White SPIDER 101 with die cast aluminium housing and polycarbonate opal diffuser and IP protection and incl making all electric connection, complete all as specified and directed by Engineer in charge. Make : Goldmedal GL9U202WW or equvqllent , |
| 24 | S&F LED 25 W Ruby Mini Post Top LED Lamp 6000 K with die cast aluminium housing and polycarbonate opal diffuser and IP protection and incl making all electric connection, complete all as specified and directed by Engineer in charge. Make:Havells or equvqllent |
| 25 | M&L for preparation old (exposed) painted surfaces of existing LT steel tubular street Light pole, struts including cross arms, clamps etc complete and applying two coats of aluminium paint over a coat of red oxide primer over the ground and making 30cm wide strip with black and yellow paint including numbering of HT/LT poles at a height of 1.5 mtr above ground level as per existing having 15mm width and 50mm bold letter complete all as specified and directed including Marking Red Stipn painting on HT Poles etc. |
| 26 | Repair to old UNSV LT Panel comprising cleaning, servicing, tightening of connections, replacement of unserviceable/damaged components such as MCCBs, MCBs, contactors, relays, indicators, selector switches, wiring and allied accessories, attending defects in busbars, terminations, earthing arrangements, repainting/anti-corrosive treatment of panel body, testing and relocated were directed incl PCC foundation etc complete all as specified and directed.”Note- Material such as MCCBs, MCBs, contactors, relays, indicators, selector switches are provided by the department. |
| 27 | S&F, in replacement, LT switch gear 440 Volts 3 phase, 4 wire 50 cycles, cubicle or truck type complete with MCCB, 63 Amps, 16 KA, ICS = 100% ICU, with adjustable thermal - Magnetic Release, including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge. |
| 28 | S&F, in replacement, LT switch gear 440 Volts 3 phase, 4 wire 50 cycles, cubicle or truck type complete with MCCB,100 Amps, 35 KA, ICS = 100% ICU, with with adjustable thermal - Magnetic Release, including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge. |
| 29 | S&F, in replacement, LT switch gear 440 Volts 3 phase, 4 wire 50 cycles, cubicle or truck type complete with MCCB, 160 Amps, 36 KA, adjustable type , including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge. |
| 30 | S&F, in replacement, LT switch gear 440 Volts 3 phase, 4 wire 50 cycles, cubicle or truck type complete with MCCB, 200 Amps, 36 KA, adjustable type including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge. |
| 31 | S&F, in replacement, LT switch gear 440 Volts 3 phase, 4 wire 50 cycles, cubicle or truck type complete with MCCB, 250 Amps, 36KA adjustable type including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge. |
| 32 | S&F, in replacement, LT switch gear 440 Volts 3 phase, 4 wire 50 cycles, cubicle or truck type complete with MCCB, 400 Amps,36 KA adjustable type including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge. |
| 33 | S&F, in replacement, LT switch gear 440 Volts 3 phase, 4 wire 50 cycles, cubicle or truck type complete with ACB, 630 Amps, 50 KA adjustable type including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge. |
| 34 | S&F, in replacement, LT switch gear 440 Volts 3 phase, 4 wire 50 cycles, cubicle or truck type complete with ACB, 800 Amps, 50 KA adjustable type including spreader terminals, phase barriers, complete all as specified and directed by Engr-in-Charge. |
| 35 | Supply and fixing in repair on load change over switch 400 Amps capacity, 415 Volts, 50 Hz, 4 Pole with advance neutral complete open execution type. Make : Standard Cat No : ISCNFO0250 |
| 36 | Supply and fixing in repair on load change over switch 315 Amps capacity, 415 Volts, 50 Hz, 4 Pole with advance neutral complete open execution type. Make : Standard Cat No : ISCNFO0251 |
| 37 | Supply and fixing in repair on load change over switch 250 Amps capacity, 415 Volts, 50 Hz, 4 Pole with advance neutral complete open execution type. Make : Standard Cat No : ISCNFO0252 |
| 38 | Supply and fixing in repair on load change over switch 200 Amps capacity, 415 Volts, 50 Hz, 4 Pole with advance neutral complete open execution type Make : Standard Cat No : ISCNFO0253 |
| 39 | Supply and fixing in repair on load change over switch 100 Amps capacity, 415 Volts, 50 Hz, 4 Pole with advance neutral complete open execution type. Make : Standard Cat No : ISCNFO0254 |
| 40 | S&F in replacement of Intelligent Panel meter to measure voltage, current, frequency, power factor, etc on LT panel with all connected CTs complete all as specified and as directed by the Engineer in charge. |
| 41 | S&F in replacement of LED indicating lamps with colour Red, Yellow, Blue - 01 Set in LT panel with all connected CTs complete all as specified and as directed by the Engineer in charge. |
| 42 | S&F in replacement of Automatic 3 Phase 415 V, 50Hz, 500KW LT Distribution Control Panel (LBS) made up of MS plate with Aluminium Bus bar for Controlling and Monitoring the mains Supply from a centralized Location with Dimension of 8 x 13 x 2ft (H x W x D) Rectangular shape complete all as specified and as directed by the Engineer in charge. |
| 43 | Supply, laying, testing and commissioning of LT UG cable XLPE insulated PVC sheathed galvanized steel strip armoured electric power cable with stranded aluminium conductor 1100 volts grade confirming to IS:7098 (Part-I), suitable for earthed system, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles & screws etc and making connection, complete all as directed. |
| 44 | Description all as per items No. 43.00 here-in-before but for 35 Sqmm 3.5 Core |
| 45 | Description all as per items No. 43.00 here-in-before but for 50 Sqmm 3.5 Core |
| 46 | Description all as per items No. 43.00 here-in-before but for 70 Sqmm 3.5 Core |
| 47 | Description all as per items No. 43.00 here-in-before but for 95 Sqmm 3.5 Core Please Enable Macros to View BoQ information |