Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | \\" BOQ \\" BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : CE BATHINDA ZONE Name of Work: PROVISION OF SOLID WASTE MANAGEMENT WORKS AT VARIOUS STNS UNDER AOR OF CWE SRIGANGANAGAR Contract No: CE BTZ/SGNR/TOKEN-57 OF 2025-26 Bidder Name : GENERAL SUMMARY (SCHEDULE OF WORKS) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # NUMBER # Sl.No. Description of Parts/ Item Item Code / Make No. orQty. Unit Pre Priced Rate (in. Rs.) as Defined by MES Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Ps. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT in Figure TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. |
| 3 | Schedule 'A' Part-I(SOLID WASTE MANAGEMENT WORKS INCLUDING CIVIL WORKS, PLANTS, MACHINERIES, ELECTRICAL, MECHANICAL, AREA DRAINAGE, SEWAGE DISPOSAL, ROADS, PATH, COMPOUND WALL, GATE, FIRE FIGHTING, ETC. WITHIN AND INCLUDING THE PERIPHERY OF COMPOUND WALL) |
| 4 | Design, procurement, construction, commissioning, solid waste management plant (at Abohar and Fazilka Mil Stn) for daily guaranteed Acceptable Waste of 2.6 tonnes at 90% probability confidence level and probable future expansion of 25% for 10 years of the contract period (for a population of 6500) with fully automated dirty materials recovery facility (MRF) with AI enabled and PLC controlled screening for handling including all activities relating to sorting, segregation, material recovery, collection, secondary storage, shredding, baling, crushing, loading, unloading, transportation, processing and disposal of solid wastes and monitoring through SCADA and complying the Solid Waste Management Rules, 2016 including creating assets, comprehensive maintenance and service with including consumable materials, chemicals, power, water etc. and shall comprise as under for the scope of works: -(a) Preparation and finalisation of Detail Project report(b) The space for stacking of solid waste of minimum 2 days.(c) Disposal of the waste materials out of the Cantonment/ defence area without any extra cost to the Department and the submission of No Objection Certificate for disposal of the waste materials in case it is asked by the department.(d) Design, prepare architectural/ structural drawing, fabrication, supply, transportation, erection of shed.(e) Design, prepare architectural/ structural drawing, supply, transportation, construction, installation of Weigh Bridge.(f) Design, prepare architectural/ structural drawing, supply, transportation, construction of wash/ change room (both male and female), various storage, processing area, dispatch area, etc.(g) Design, fabrication, supply, transportation, installation of Solid Waste Management Plant including feeding hooper, conveyor belts, trammel screening machine, magnetic separator, shredder machine, balling machine, organic waste composer, air blower, solid waste incinerator. |
| 5 | Srl Item No 1.001 Continued......(h) Standby power back up with Diesel Generator Set and Solar Power Plant as per the discretion of the contractor of suitable capacity. The fuel shall be supplied by the contractor during the operation, maintenance and service period. Diesel Engine Generator Set shall be as per the latest CPCB norms.(i) Electricity supplied by the department shall be charged from the contractor at the rate charged by the concerned State Power Corporation Limited from the department.(j) Design, prepare architectural/ structural drawing, supply, transportation, construction of garages, compound wall of height 2.4 metre, barbed wire fencing of height 0.6 metre above the compound wall, gates, roads, area drainage, sewage disposal, internal electrification, inter water supply, firefighting arrangement, area lighting.(k) Obtain statutory clearance from Government.(l) Maintain, operate, including repairing, replacing, etc. plants and the infrastructure created for 10 years after creating the assets. The contractor shall have full ownership of the materials extracted from solid waste. No royalty shall be charged by the Government. However no compensation shall be paid for lesser quantities of solid waste.(m) The rates quoted are inclusive of operation, comprehensive maintenance and service and the payment schedule shall be as under: -(A) After Finalisation of detail project report- Nil(B) After creating assets - 70% of the quoted amount (As per the Yard stick approved by CE for Interim Payment/ Advance on Account)(C) After creating assets - 70% of the quoted amount (As per the Yard stick approved by CE for intermediate period)(D) After completion of 1 year of comprehensive maintenance: 72%(E) After completion of 2 year of comprehensive maintenance: 74%(F) After completion of 3 year of comprehensive maintenance: 76%(G) After completion of 4 year of comprehensive maintenance: 79%(H) After completion of 5 year of comprehensive maintenance: 82%(I) After completion of 6 year of comprehensive maintenance: 85% |
| 6 | Srl Item No 1.001 Continued......(J) After completion of 7 year of comprehensive maintenance: 88%(K) After completion of 8 year of comprehensive maintenance: 92%(L) After completion of 9 year of comprehensive maintenance: 96%(M) After completion of 10 year of comprehensive maintenance: 100%(N) The retention money shall be as applicable.(n) Monthly testing solid waste parameters before and after processing from NABL approved lab. |
| 7 | Design, procurement, construction, commissioning, solid waste management plant (at Lalgarh Jattan and Sri Ganganagar Mil Stn) for daily guaranteed Acceptable Waste of 6.4 tonnes at 90% probability confidence level and probable future expansion of 25% for 10 years of the contract period (for a population of 16000) with fully automated dirty materials recovery facility (MRF) with AI enabled and PLC controlled screening for handling including all activities relating to sorting, segregation, material recovery, collection, secondary storage, shredding, baling, crushing, loading, unloading, transportation, processing and disposal of solid wastes and monitoring through SCADA and complying the Solid Waste Management Rules, 2016 including creating assets, comprehensive maintenance and service with including consumable materials, chemicals, power, water etc. and shall comprise as under for the scope of works: -(a) Preparation and finalisation of Detail Project report(b) The space for stacking of solid waste of minimum 2 days.(c) Disposal of the waste materials out of the Cantonment/ defence area without any extra cost to the Department and the submission of No Objection Certificate for disposal of the waste materials in case it is asked by the department.(d) Design, prepare architectural/ structural drawing, fabrication, supply, transportation, erection of shed.(e) Design, prepare architectural/ structural drawing, supply, transportation, construction, installation of Weigh Bridge.(f) Design, prepare architectural/ structural drawing, supply, transportation, construction of wash/ change room (both male and female), various storage, processing area, dispatch area, etc.(g) Design, fabrication, supply, transportation, installation of Solid Waste Management Plant including feeding hooper, conveyor belts, trammel screening machine, magnetic separator, shredder machine, balling machine, organic waste composer, air blower, solid waste incinerator. |
| 8 | Srl Item No 1.002 Continued......(h) Standby power back up with Diesel Generator Set and Solar Power Plant as per the discretion of the contractor of suitable capacity. The fuel shall be supplied by the contractor during the operation, maintenance and service period. Diesel Engine Generator Set shall be as per the latest CPCB norms.(i) Electricity supplied by the department shall be charged from the contractor at the rate charged by the concerned State Power Corporation Limited from the department.(j) Design, prepare architectural/ structural drawing, supply, transportation, construction of garages, compound wall of height 2.4 metre, barbed wire fencing of height 0.6 metre above the compound wall, gates, roads, area drainage, sewage disposal, internal electrification, inter water supply, firefighting arrangement, area lighting.(k) Obtain statutory clearance from Government.(l) Maintain, operate, including repairing, replacing, etc. plants and the infrastructure created for 10 years after creating the assets. The contractor shall have full ownership of the materials extracted from solid waste. No royalty shall be charged by the Government. However no compensation shall be paid for lesser quantities of solid waste.(m) The rates quoted are inclusive of operation, comprehensive maintenance and service and the payment schedule shall be as under: -(A) After Finalisation of detail project report- Nil(B) After creating assets - 70% of the quoted amount (As per the Yard stick approved by CE for Interim Payment/ Advance on Account)(C) After creating assets - 70% of the quoted amount (As per the Yard stick approved by CE for intermediate period)(D) After completion of 1 year of comprehensive maintenance: 72%(E) After completion of 2 year of comprehensive maintenance: 74%(F) After completion of 3 year of comprehensive maintenance: 76%(G) After completion of 4 year of comprehensive maintenance: 79%(H) After completion of 5 year of comprehensive maintenance: 82% |
| 9 | Srl Item No 1.002 Continued......(I) After completion of 6 year of comprehensive maintenance: 85%(J) After completion of 7 year of comprehensive maintenance: 88%(K) After completion of 8 year of comprehensive maintenance: 92%(L) After completion of 9 year of comprehensive maintenance: 96%(M) After completion of 10 year of comprehensive maintenance: 100%(N) The retention money shall be as applicable.(n) Monthly testing solid waste parameters before and after processing from NABL approved lab. |
| 10 | Design, procurement, construction, commissioning, solid waste management plant (at Faridkot Mil Stn) for daily guaranteed Acceptable Waste of 3.0 tonnes at 90% probability confidence level and probable future expansion of 25% for 10 years of the contract period (for a population of 7500) with fully automated dirty materials recovery facility (MRF) with AI enabled and PLC controlled screening for handling including all activities relating to sorting, segregation, material recovery, collection, secondary storage, shredding, baling, crushing, loading, unloading, transportation, processing and disposal of solid wastes and monitoring through SCADA and complying the Solid Waste Management Rules, 2016 including creating assets, comprehensive maintenance and service with including consumable materials, chemicals, power, water etc. and shall comprise as under for the scope of works: -(a) Preparation and finalisation of Detail Project report(b) The space for stacking of solid waste of minimum 2 days.(c) Disposal of the waste materials out of the Cantonment/ defence area without any extra cost to the Department and the submission of No Objection Certificate for disposal of the waste materials in case it is asked by the department.(d) Design, prepare architectural/ structural drawing, fabrication, supply, transportation, erection of shed.(e) Design, prepare architectural/ structural drawing, supply, transportation, construction, installation of Weigh Bridge.(f) Design, prepare architectural/ structural drawing, supply, transportation, construction of wash/ change room (both male and female), various storage, processing area, dispatch area, etc.(g) Design, fabrication, supply, transportation, installation of Solid Waste Management Plant including feeding hooper, conveyor belts, trammel screening machine, magnetic separator, shredder machine, balling machine, organic waste composer, air blower, solid waste incinerator. |
| 11 | Srl Item No 1.003 Continued......(h) Standby power back up with Diesel Generator Set and Solar Power Plant as per the discretion of the contractor of suitable capacity. The fuel shall be supplied by the contractor during the operation, maintenance and service period. Diesel Engine Generator Set shall be as per the latest CPCB norms.(i) Electricity supplied by the department shall be charged from the contractor at the rate charged by the concerned State Power Corporation Limited from the department.(j) Design, prepare architectural/ structural drawing, supply, transportation, construction of garages, compound wall of height 2.4 metre, barbed wire fencing of height 0.6 metre above the compound wall, gates, roads, area drainage, sewage disposal, internal electrification, inter water supply, firefighting arrangement, area lighting.(k) Obtain statutory clearance from Government.(l) Maintain, operate, including repairing, replacing, etc. plants and the infrastructure created for 10 years after creating the assets. The contractor shall have full ownership of the materials extracted from solid waste. No royalty shall be charged by the Government. However no compensation shall be paid for lesser quantities of solid waste.(m) The rates quoted are inclusive of operation, comprehensive maintenance and service and the payment schedule shall be as under: -(A) After Finalisation of detail project report- Nil(B) After creating assets - 70% of the quoted amount (As per the Yard stick approved by CE for Interim Payment/ Advance on Account)(C) After creating assets - 70% of the quoted amount (As per the Yard stick approved by CE for intermediate period)(D) After completion of 1 year of comprehensive maintenance: 72%(E) After completion of 2 year of comprehensive maintenance: 74%(F) After completion of 3 year of comprehensive maintenance: 76%(G) After completion of 4 year of comprehensive maintenance: 79%(H) After completion of 5 year of comprehensive maintenance: 82%(I) After completion of 6 year of comprehensive maintenance: 85% |
| 12 | Srl Item No 1.003 Continued......(J) After completion of 7 year of comprehensive maintenance: 88%(K) After completion of 8 year of comprehensive maintenance: 92%(L) After completion of 9 year of comprehensive maintenance: 96%(M) After completion of 10 year of comprehensive maintenance: 100%(N) The retention money shall be as applicable.(n) Monthly testing solid waste parameters before and after processing from NABL approved lab. |
| 13 | Lump sum price worked out by the tenderer for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-II(Ref pre-priced schedule attached separately) |
| 14 | Lump sum price worked out by the tenderer for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part-III(Ref pre-priced schedule attached separately) |
| 15 | Lump sum price worked out by the tenderer for ROAD, PATH, HARD STANDING AND CULVERT WORKS as listed in Schedule ‘A’ Part-IV(Ref pre-priced schedule attached separately) |
| 16 | Lump sum price worked out by the tenderer for DRAIN as listed in Schedule ‘A’ Part-V(Ref pre-priced schedule attached separately) |
| 17 | Lump sum price worked out by the tenderer for DEMOLITION as listed in Schedule ‘A’ Part-VI(Ref pre-priced schedule attached separately) |
| 18 | Lump sum price worked out by the tenderer for SITE CLEARANCE, EXCAVATION AND EARTH WORKS as listed in Schedule ‘A’ Part-VII(Ref pre-priced schedule attached separately) |
| 19 | Schedule 'A' Part-VIII(MISCELLANEOUS WORKS) |
| 20 | Providing and laying 80 mm thick factory made rubber coated, chamfered edge cement concrete paver block of M-40 conforming to IS 15658: 2021 grade with approved colour, design and pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness, size and shape, made by table vibratory method using polyurethane mould, laid in required colour and pattern over and including 30 mm thick compacted bed of coarse sand having gradation as per IRC SP 63: 2018 and 2 to 4 mm wide joints filled with fine sand having gradation as per IRC SP 63: 2018, compacting and proper embedding/ laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed. |
| 21 | M & L for cutting galvanised mild steel pipe of nominal bore 80 mm, in position for and including insertion of new tee piece including necessary fittings and fixtures complete all as specified and as directed. |
| 22 | Drilling and tapping cast iron water mains (in position) for branch connections of the internal dia 20 mm including brass ferrule complete all as specified and as directed. |
| 23 | M & L for construction of new valve pit/chamber of size 600 mm (Length) X 600 mm (Breadth) X 600 mm (depth) including necessary earth work in any type of soil, PCC foundation M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate as in base concrete, brick work with sub class 'B' bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, cement plaster 20 mm thick internally in two coats of (15 mm and 5 mm) in cement mortar 1:4, 3 mm thick mild steel sheet of any grade and designation as per IS 513: 2008 and IS 10748: 2004 welded with angle iron (40 mm X 40 mm X 6 mm) frame of structural steel, frame welded with angle iron (50 mm X 50 mm X 6 mm) frame of structural steel, welded to flat iron of size 150 mm X 50 mm X 6 mm of structural steel, fixed with bolt of 16 mm dia anchored with plate of size 100 mm X 100 mm X 3 mm of structural steel, bolt and anchored plate embedded in 250 mm thick PCC coping in M15(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, mild steel handle, grade E165 as per IS 15911: 2010 for structural steel with necessary, welding, riveting, bolting including painting exposed steel surfaces with two coats of bituminous paint and embedded surfaces of steel with two coats of tar, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash and all as per drawing No. BTD-811 Sheet Nos 1/2 and 2/2 of HQ CE Bathinda Zone complete all as specified and as directed. |
| 24 | M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed. |
| 25 | M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed. |
| 26 | M & L for auguring under road, pavement, hard standing, railway lines by trenchless technology using latest boring technique and necessary machine for insertion of GI/CI/PP-R/PVC pipe of any dia/ bore/size complete all as specified and as directed. |
| 27 | S & F two core flat, FR-LSH cables for outdoor use, PVC insulation of type C and having PVC sheath of type ST2, 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor for fittings complete all as specified and as directed. |
| 28 | S & F single core flexible conductor FR-LSH cables, PVC insulation of type C and having PVC sheath of type ST2, 10 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor laid in existing conduit complete all as specified and as directed. |
| 29 | S & F LED flood lights nominal power 120 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700⁰K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No. LF20-132-060-57-XX of Wipro or equivalent of Make mentioned under Appendix \\"B\\" including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed. |
| 30 | Supply and fix PVC/Polycarbonate made junction box having two incoming and one outgoing cable ways along with fixing arrangement complete including 01 No MCB of C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 for streetlight complete all as specified and as directed. |
| 31 | Supply and erect factory made 7 meter long hot dip galvanized (as per relevant IS with average coating thickness 65 micron) octagonal poles conform to IS-2062/ BSEN 10025 with 155 mm dia at bottom and 70 mm dia at top A/F made up of 3 mm thick HT sheet along with foundation type base plate of size 250 mm X 250 mm X 16 mm, foundation bolt 4 Nos of M20 X 600 mm high 'J' type EN8 grade, including 1 meter long hot dip galvanized single arm (swan neck) bracket made up of 40 NB dia GI pipe and including excavation, earth work, PCC (1:2:4) type B1 for foundation and grouting the bolts as per manufacturer’s instructions including marking pole number in letters & figures of size not less than 10 cm height with red colour enamel paint including junction box with 2 pole aluminium bus bar of suitable size including 01 No. MCB SP, 6-32 Amps, AC, 50 Hz for distribution alongwith mounting accessories complete all as specified and as directed. Note: PCC for foundation of pole shall be provided as per manufacturers recommendation and same shall be measured and paid separately under relevant item. |
| 32 | Supply and fix metal oxide surge arrester without gap for AC system as per IEC 60099-4: 2014, outdoor type, polymer housing, single column and single phase construction, distribution class, medium duty, nominal discharge current 5 kA, repetitive charge transfer rating (Qrs) more than 0.2 C, thermal charge transfer rating (Qth) more than 0.7 C, nominal system voltage 11 kV, highest system voltage 12 kV, rated voltage of arrester 9 kV, continuous operating voltage 7.2 kV, temporary overvoltage (10.50 kV for 1 s, 9.90 kV for 10 s, 9.35 kV for 100 s), rated short circuit current 20 kA, low short circuit current 600 A, insulation withstand level (lightning impulse voltage 1.2/ 50 µs) 75 kV, lightning impulse residual voltage (8/20 µs) at nominal discharge current maximum 22 kV, high current impulse withstand capability (4/10 µs) 65 kA, minimum creepage distance 300 mm complete all as specified and as directed. |
| 33 | Supplying, installing, testing and commissioning outdoor type compact substation (CSS), factory assembled (non walk type) having 11 kV, 630 Amps, internal arc fault for 20 kA for 1 sec as per IEC 61330/62271-200 and comprising as under: -(A) MV COMPARTMENT: 11 KV, 630A, 25 kA/3 Sec indoor type non-extensible, SF6 gas insulated Ring Main unit with sealed pressure system criterion in accordance with the IEC: 60298,62271 - 202.IAC category IAC-AFL. The Switchgear includes the following HV cubiclesThe indoor non -extensible SF6 insulated RMU fully motorised consist of 1 No. Vacuum Circuit Breaker with Riser (ICOG type) with self-powered relay for protection of transformer (a) Rated voltage should be - 12 kV(b) Rated power frequency voltage - 28 kV(c) Rated lightening withstand voltage - 75 kV(d) Rated current for Ring main feeder - 630 amps(e) Rated current for LBS feeder - 630 amps(f) Rated short time current - 25 kA / 3 sec(g) Rated short time making current -50 kA(h) Ambient temperature (0⁰C to 50⁰C)(i) Rated internal arc rating - 20 KA for 1 sec for tank and cable box category IAC-AFLR(j) RMU shall be provided with protection CTs rated for 30 / 1 amps, class – 10 P10 accuracy, 2.5 VA burden for circuit breaker(k) The feeder shall be self-powered/powered by external source and shall be provided with OC+EF protection for transformer and shall have serial port for communication on modbus protocol.(l) Dead short Circuit life of VI - 40 No |
| 34 | Srl Item No 8.014 Continued......(B) TRANSFORMER COMPARTMENT: Supplying, installing, connecting, testing & commissioning mineral oil immersed, natural air-cooled, outdoor type, double wound (copper) distribution transformer, three phase, 100 kVA rating, non-sealed type, 50 Hz rated frequency, 11 kV high voltage and 415 V low voltage nominal system voltage, minimum 75 kVp basic insulation level, 11000 V/ 433-250 V no-load voltage ratio, connection (vector) symbol Dyn11, 30⁰ positive phase displacement, off circuit tap changing arrangement for voltage variations of +2.5% to -5% in steps of 2.5% for variation of HV, minimum energy efficiency level 2 (Star 2 as per the notification issued by the Central Government, in consultation with the Bureau of Energy Efficiency and including all the amendments issued up-to-date), 4.5% impedance, ONAN type cooling all as per IS-1180 (Part 1): 2014 including amendment upto and including amendment No. 4 dated 04 Mar 2021 complete with all fittings, accessories and item as specified and as directed. Note: - The energy efficiency level higher than the minimum energy efficiency level as specified here shall be provided without any extra cost in case the transformer of minimum energy efficiency level is not available.(C) LV COMPARTMENT: The LV compartment with Degree of protection-IP54 designed for a 50-degree C ambient temperature. The panel is modular, dead front, freestanding, floor mounted and comprises the following equipment: - (a) 1000 Amps, 50kA withstand fault level capacity rated copper bus bar fully insulated with class F materials and nuts, bolts, washers for connection (b) Air Circuit Breaker (ACB) of rated current 630 A, Rated operational voltage 415 V, Rated insulation voltage 1000 V, 4 Pole, 50 Hz AC supply, Rated ultimate short circuit breaking capacity 50 kA, Rated service short circuit breaking capacity 50 kA, Rated short time withstand capacity 50 kA for 1 second, Rated making capacity 105 kA, Rated impulse withstand voltage of main circuit 8 kV, typical opening time 40 ms, typical closing time 60 ms, thermal magnetic release, manual draw out, overload protection, short circuit protection, earth fault protection (Incomer)(c) Outgoing – (i) 320A, 4P, Thermal Magnetic MCCB-Double Make & Double break type, Ics=25kA - 1 No, (ii) 160A,4P, Thermal Magnetic MCCB-Double Make & Double break type, Ics-=25kA - 1 No, (iii) MCB TPN, 32 Amp, 10 kA- 01 (iv) MCB SPN, 10 kA, 6 to 32 Amos – 4 Nos (D) ACCESSORIES: |
| 35 | Srl Item No 8.014 Continued......(a) Multifunctional meter digital type of adequate capacity showing voltage, current, frequency, power factor, Kilo watt, Kilo watt hour with inbuilt selector switch with current transformer coils for three phase: - 1 No (b) LED indicating lamps (c) Danger Notice Plates for HT & LT(d) COMPACT SUBSTATION (CSS) ENCLOSURE:- Outdoor type enclosure of 1.5 mm (For non-load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. Vacuum Interrupter, RMU, LT panel switchgear and CSS enclosure shall be of same make to ensure life cycle optimization. The design of the enclosure should be type tested for suitably handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment. Vacuum Interrupter, RMU, LT panel switchgear and CSS enclosure shall be of same make to ensure life cycle optimization. All Civil works such as PCC/RCC foundation, Platform, Filling trench and pedestal etc. as per CSS manufacturer's recommendation are included in scope of work.NOTE:-1) As per clause 7.102 of IEC 62271-202-2022 internal arc test in transformer chamber is must, it should be 20 kA for 1 Sec type A & type B.2) Interconnection between HT breaker and transformer through HT cable 95 sqmm also interconnection between transformer and LT panel through suitable size of aluminium bus bar. |
| 36 | Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 63 mm, minimum inside dia 47 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed. |
| 37 | Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 110 mm, minimum inside dia 82 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed. |
| 38 | Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 140 mm, minimum inside dia 106 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed. |
| 39 | Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 200 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed and shall be comprising the followings: - (A) 200 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos(B) Wiring with single core PVC, copper power cable of suitable size(C) Incoming: (a) MCCB rated current (In): 125 A, Icu: 36 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No(D) Outgoing:(a) MCCB rated current (In):32 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -8 Nos(b) MCB, TPN, 10 kA, B-type, rated current 20 A: -8 Nos(E) Accessories:(a) Digital voltmeter 0-500 V with selector switch – 1 No(b) Digital ammeter 0-400 Amps with CT and selector switch – 1 No |
| 40 | Srl Item No 8.018 Continued......(c) LED indicating lamps – 4 Nos(d) Danger Notice Plate for LT(F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm.) |
| 41 | Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 200 Amps rated copper bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed and shall be comprising the followings: - (A) 200 Amps rated copper bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos(B) Wiring with single core PVC, copper power cable of suitable size(C) Incoming: (a) MCCB rated current (In): 125 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No(D) Outgoing:(a) MCCB rated current (In):100 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No(b) MCCB rated current (In): 40 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No(E) Accessories: |
| 42 | Srl Item No 8.019 Continued......(a) Multi-functional digital Voltmeter and ampere meter including suitable and appropriate CTs-01 Set(b) LED indicating lamps – 4 Nos(c) Danger Notice Plate for LT(F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm.) |
| 43 | Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 200 Amps rated copper bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed and shall be comprising the followings: - (A) 200 Amps rated copper bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos(B) Wiring with single core PVC, copper power cable of suitable size(C) Incoming: (a) MCCB rated current (In): 250 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No(D) Outgoing:(a) MCCB rated current (In):63 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No(E) Accessories:(a) Multi-functional digital Voltmeter and ampere meter including suitable and appropriate CTs-01 Set(b) LED indicating lamps – 4 Nos |
| 44 | Srl Item No 8.02 Continued......(c) Danger Notice Plate for LT(F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm.) |
| 45 | Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 200 Amps rated copper bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed and shall be comprising the followings: - (A) 200 Amps rated copper bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos(B) Wiring with single core PVC, copper power cable of suitable size(C) Incoming: (a) MCCB rated current (In): 125 A, Icu: 36 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No(D) Outgoing:(a) MCCB rated current (In):32 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -6 Nos(E) Accessories:(a) Multi-functional digital Voltmeter and ampere meter including suitable and appropriate CTs-01 Set(b) LED indicating lamps – 4 Nos |
| 46 | Srl Item No 8.021 Continued......(c) Danger Notice Plate for LT(F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm.) |
| 47 | Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 320 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed and shall be comprising the followings: - (A) 320 Amps rated copper bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos(B) Wiring with single core PVC, copper power cable of suitable size(C) Incoming: (a) MCCB rated current (In): 200 A, Icu: 36 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No(D) Outgoing:(a) MCCB rated current (In):63 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -2 Nos(b) MCCB rated current (In): 40 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -2 Nos |
| 48 | Srl Item No 8.022 Continued......(c) MCCB rated current (In): 20 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No(d) MCB, SPN, 10 kA, C-type, rated current 6 to 32 A: -3 Nos(E) Accessories:(a) Multi-functional digital Voltmeter and ampere meter including suitable and appropriate CTs-01 Set(b) LED indicating lamps – 4 Nos(c) Danger Notice Plate for LT(F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm.) Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail