| 1 | Supply Part |
| 2 | Fabricated MS Channel X- Arm (75x40x6mm) 1-Phase 2Wire (2ft) |
| 3 | Fabricated MS Channel X- Arm (75x40x6mm) 3-Phase 4 Wire (4ft) |
| 4 | Fabricated GI Channel X- Arm (75x40x6mm) 1-Phase 2Wire (2ft) |
| 5 | Fabricated GI Channel X- Arm (75x40x6mm) 3-Phase 4Wire (4ft) |
| 6 | Fabricated MS Channel X- Arm (75x40x6mm) (8ft) for H-Frame |
| 7 | Fabricated MS Channel X- Arm (75x40x6mm) 10 ft long |
| 8 | Fabricated GI Channel X- Arm (75x40x6mm) (8ft) for H-Frame |
| 9 | Fabricated GI Channel X- Arm (75x40x6mm) 10 ft long |
| 10 | Fabricated MS Channel X- Arm (100x50x6mm) (8ft) for sub-station |
| 11 | Fabricated MS Channel X- Arm (100x50x6mm) 10 ft long |
| 12 | Fabricated angle iron/Channel items as per site requirement. |
| 13 | Fabricated GI Channel X- Arm (100x50x6mm) (8ft) for sub-station |
| 14 | Fabricated GI Channel X- Arm (100x50x6mm) 10 ft long |
| 15 | Fabricated MS 11KV V-Shaped (75x40x6mm) Cross Arm |
| 16 | Fabricated GI 11KV V-Shaped (75x40x6mm) Cross Arm |
| 17 | Fabricated MS Angle Pole Top Bracket (50x50x6 mm) |
| 18 | Fabricated GI angle Pole Top Bracket (50x50x6 mm) |
| 19 | Fabricated MS angle clamps made of 50X8 mm |
| 20 | GI angle clamps made of 50X8 mm |
| 21 | 11 KV Link Set Station Type (Heavy duty) 200A with copper strip |
| 22 | 11 KV Link Set Post Type (Heavy duty) 200A with copper strip |
| 23 | 11 KV Link Set Station Type (Heavy duty) 400A with copper strip |
| 24 | 11 KV Link Set Post Type (Heavy duty) 400A with copper strip |
| 25 | 11 kV Horn Gap Fuse 3-phase 100A |
| 26 | Gapless Surge Arrestor,9 kV,10 kA, LA with (polymer) housing, Station Type |
| 27 | Gapless Surge Arrestor,9 kV,10 kA, LA with (polymer) housing, Post Type |
| 28 | Gapless Surge Arrestor,9 kV,10 kA, LA with (procelein) housing, Station Type |
| 29 | Gapless Surge Arrestor,9 kV,10 kA, LA with (procelein) housing, Post Type |
| 30 | 11 kV Disc Insulators (polymer) Complete with fittings (45KN) |
| 31 | 11 kV Disc Insulators (polymer) Complete with fittings (75KN) |
| 32 | 11 kV Disc Insulators (porcelein) Complete with fittings (45KN) |
| 33 | 11 kV Disc Insulators (porcelein) Complete with fittings (75KN) |
| 34 | 11 KV Pin Insulator (5KN) .porcelein make with GI pin |
| 35 | 11 KV Pin Insulator (5KN), polymer make with GI pin |
| 36 | 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with GI Pin |
| 37 | 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with disc fitting |
| 38 | LT Shackle Insulator porcelien with n/b |
| 39 | LT Shackle Insulator polymer with n/b |
| 40 | GI U -Clamp for Shackle insulator |
| 41 | Suspension Clamp/Dead end clamp for 35 mm sq AB cable |
| 42 | Suspension Clamp/Dead end clamp for 50 mm sq AB cable |
| 43 | Suspension Clamp/Dead end clamp for 70 mm sq AB cable |
| 44 | Suspension Clamp/Dead end clamp for 95 mm sq AB cable |
| 45 | Suspension Clamp/Dead end clamp for 120 mm sq AB cable |
| 46 | Eye Hook |
| 47 | MS Clamp of Size (40x6mm) Suitable for 9mtr pole |
| 48 | Clamp of Size (40x6mm) (Galvanised) |
| 49 | MS Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia MS stranded wire complete for 11 KV Tension points as per REC standard. |
| 50 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia MS stranded wire complete for 11 KV Tension points as per REC standard. |
| 51 | Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 300 mm sq cross section un-armoured XLPE cable, FRLS . |
| 52 | Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 185 mm sq cross section un-armoured FRLS XLPE cable |
| 53 | Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 120 mm sq cross section un-armoured, FRLS XLPE cable |
| 54 | Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 95 mm sq cross section un-armoured FRLS XLPE cable |
| 55 | Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 70 mm sq cross section un-armoured FRLS XLPE cable |
| 56 | Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 50 mm sq cross section un-armoured FRLS XLPE cable |
| 57 | Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 35 mm sq cross section un-armoured FRLS XLPE cable |
| 58 | Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 25/20 mm sq cross section un-armoured FRLS XLPE cable |
| 59 | Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 16 mm sq cross section un-armoured FRLS XLPE cable |
| 60 | 3&1/2 Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 300 mm sq cross section un-armoured XLPE cable, FRLS . |
| 61 | 3&1/2 Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 185 mm sq cross section un-armoured FRLS XLPE cable |
| 62 | 3&1/2 Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 120 mm sq cross section un-armoured, FRLS XLPE cable |
| 63 | 3&1/2 Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 95 mm sq cross section un-armoured FRLS XLPE cable |
| 64 | 3&1/2 Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 70 mm sq cross section un-armoured FRLS XLPE cable |
| 65 | 3&1/2 Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 50 mm sq cross section un-armoured FRLS XLPE cable |
| 66 | 3&1/2 Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 35 mm sq cross section un-armoured FRLS XLPE cable |
| 67 | 3&1/2 Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 25/20 mm sq cross section un-armoured FRLS XLPE cable |
| 68 | 11KV AB Cable kit 3-core (heat shrinkable) out-door type 35mmsq |
| 69 | 11KV AB Cable kits (heat shrinkable) indoor type 3 core 35mmsq |
| 70 | 11KV AB Cable kits 3-core (heat shrinkable) out-door type 16mmsq |
| 71 | 11KV AB Cable kits (heat shrinkable) indoor type 3-Core 16mmsq |
| 72 | 11KV AB Cable kits 3-core (heat shrinkable) out-door type 50mmsq |
| 73 | 11KV AB Cable kits (heat shrinkable) indoor type 3-Core 50mmsq |
| 74 | 11KV AB Cable kits 3-core (heat shrinkable) out-door type 70mmsq |
| 75 | 11KV AB Cable kits (heat shrinkable) indoor type 3-Core 70mmsq |
| 76 | 11KV AB Cable kits 3-core (heat shrinkable) out-door type 120mmsq |
| 77 | 11KV AB Cable kits (heat shrinkable) indoor type 3-Core 120mmsq |
| 78 | Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 300mmsq cross section armoured XLPE cable . |
| 79 | Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 185 mm sq cross section armoured XLPE cable |
| 80 | Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 120 mm sq cross section armoured XLPE cable |
| 81 | Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 95mmsq cross section armoured XLPE cable |
| 82 | Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 50mmsq cross section armoured XLPE cable |
| 83 | Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 35mmsq cross section armoured XLPE cable |
| 84 | Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 25/20mmsq cross section armoured XLPE cable |
| 85 | Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 16mmsq cross section armoured XLPE cable |
| 86 | 3&1/2 Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 300mmsq cross section armoured XLPE cable . |
| 87 | 3&1/2 Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 185 mm sq cross section armoured XLPE cable |
| 88 | 3&1/2 Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 120 mm sq cross section armoured XLPE cable |
| 89 | 3&1/2 Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 95mmsq cross section armoured XLPE cable |
| 90 | 3&1/2 Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 50mmsq cross section armoured XLPE cable |
| 91 | 3&1/2 Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 35mmsq cross section armoured XLPE cable |
| 92 | 3&1/2 Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 25/20mmsq cross section armoured XLPE cable |
| 93 | 3&1/2 Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 16mmsq cross section armoured XLPE cable |
| 94 | 3x120 mmSq 11KV Grade (E) Aerial Bunched Cable |
| 95 | 3x95 mmSq 11KV Grade (E) Aerial Bunched Cable |
| 96 | 3x50 mmSq 11KV Grade (E) Aerial Bunched Cable |
| 97 | 3x185 mmSq 3 core 11KV XLPE Armoured Cable |
| 98 | 35mm², 3½ core 1.1 KV Grade PVC Insulated Standard Alu. Conductor cable FRLS type ( Standard make) |
| 99 | 95mm², 3½ core 1.1 KV Grade PVC Insulated Standard Alu. Conductor cable FRLS type ( Standard make) |
| 100 | 120mm², 3½ core 1.1 KV Grade PVC Insulated Standard Alu. Conductor cable FRLS type ( Standard make) |
| 101 | 3x50 mmSq 3 core11KV Unarmoured Cable |
| 102 | 3x95 mmSq 3 Core 11KV Unarmoured Cable |
| 103 | 3x120 mmSq 3 core 11KV Unarmoured Cable |
| 104 | 3x185 mmSq 3 core 11KV Unarmoured Cable |
| 105 | 3x50 mmSq 3 core11KV Armoured Cable |
| 106 | 3x95 mmSq 3 Core 11KV Armoured Cable |
| 107 | 3x120 mmSq 3 core 11KV Armoured Cable |
| 108 | 3x185 mmSq 3 core 11KV Armoured Cable |
| 109 | 2 Core 16mm² Service cable |
| 110 | 2 Core 10mm² Service cable |
| 111 | 3 Core Cable Termination Kit |
| 112 | Single Core Cable Termination Kit |
| 113 | 35mm² LT AB Cable |
| 114 | 50mm² LT AB Cable |
| 115 | 70mm² LT AB Cable |
| 116 | 95mm² LT AB Cable |
| 117 | 120mm² LT AB Cable |
| 118 | HDPE Pipe for underground cabling 95sqmm |
| 119 | HDPE Pipe for underground cabling 120sqmm |
| 120 | HDPE Pipe for underground cabling 185sqmm |
| 121 | HDPE Pipe for underground cabling 240sqmm |
| 122 | PVC Conduit Pipe |
| 123 | PVC Conduit Bend |
| 124 | ST Pole 13 mtr Long flange type with base & cap (410-SP-56) |
| 125 | ST Pole 11 mtr Long flange type with base & cap (410-SP-56) |
| 126 | ST Pole 9 mtr Long with base & cap (410-SP-33) |
| 127 | ST Pole 8 mtr Long with base & cape (410-SP-15) |
| 128 | Aluminium Paint |
| 129 | ACSR 0.03 Weasel conductor (30mmsq) |
| 130 | ACSR 0.05 Rabbit conductor (50mmsq) |
| 131 | ACSR 0.1 Dog conductor |
| 132 | Silicon Cover for 0.03 Weasel Conductor |
| 133 | Silicon Cover for 0.05 Rabbit Conductor |
| 134 | Aluminum Thimbles of different Size for cable terminations of different size |
| 135 | HT Bush & Bush Rods for 25KVA transformers |
| 136 | HT Bush & Bush Rods for 63KVA transformers |
| 137 | HT Bush & Bush Rod for 100KVA transformers |
| 138 | HT Bush & bush Rods for 200KVA/250KVA transformers |
| 139 | HT Bush & Rods for 300KVA transformers |
| 140 | HT Bush bush Rods for 400KVA transformers |
| 141 | HT Bush & bush Rods for 500KVA transformers |
| 142 | HT Bush & bush Rods for 630KVA transformers |
| 143 | HT Bush & bush Rods for 1000KVA transformers |
| 144 | HT Bush & bush Rods for 1500KVA/1600KVA transformers |
| 145 | LT Bush & Bush Rods for 25KVA transformers |
| 146 | LT Bush & Bush Rods for 63KVA transformers |
| 147 | LT Bush & Bush Rod for 100KVA transformers |
| 148 | LT Bush & bush Rods for 200KVA/250KVA transformers |
| 149 | LT Bush & Rods for 300KVA transformers |
| 150 | LT Bush bush Rods for 400KVA transformers |
| 151 | LT Bush & bush Rods for 500KVA transformers |
| 152 | LT Bush & bush Rods for 630KVA transformers |
| 153 | LT Bush & bush Rods for 1000KVA transformers |
| 154 | LT Bush & bush Rods for 1500KVA/1600KVA transformers |
| 155 | Aluminium Ladder 10 meter long |
| 156 | Folding Telescopic Aluminium Ladder 10 meter long |
| 157 | Oil testing machine Confirming to IS standard Test voltage, 0-80 KV |
| 158 | Heavy Duty Crimping Tools suitable upto 630 mm2 |
| 159 | Heavy Duty Hydrolic crimping Tools suitable upto 630 mm2 |
| 160 | LED Light 45 watt with complete Assembly for street lighting of Standard make (Havells, Bajaj etc) |
| 161 | LED Light 60 watt with complete Assembly Standard make(Havells, Bajaj etc) |
| 162 | LED Light 120 watt with complete asssembly of Standard make (Havells, Bajaj etc) |
| 163 | LED Flood Light 50 watt with complete asssembly of Reputed make |
| 164 | LED Flood Light 100 watt with complete asssembly of Reputed make |
| 165 | LED Flood Light 200 watt with complete asssembly of Reputed make |
| 166 | LED Flood Light 500 watt with complete asssembly of Reputed make |
| 167 | MCCB switch AP 10 Amps ( Standard make ) |
| 168 | MCCB switch AP 6 Amps ( Standard make ) |
| 169 | MCCB switch AP 32 Amps ( Standard make ) |
| 170 | MCB Switch 10 A ( of reputed make ) |
| 171 | MCB Switch 20 A ( of reputed make ) |
| 172 | MCB Switch 100A ( of reputed make ) |
| 173 | Change over switch TPN 32 Amps of reputed company make |
| 174 | Change over switch TPN 64 Amps of reputed company make |
| 175 | 3 No. sub station earthing by MS Pipe 40 mm or MS Rod 20mm, 2.5 mtr long through MS Strip of 50X6 mm 1 no for neutral earthing and 25X3 mm 2 nos (for 2 transformer body earth, two no. pole earth, 1 no. LA Earth and 1 no. GO handle earth). Note: For LA Earth 1 pipe shall be kept separate. |
| 176 | MS Spiral Earthing, 8 SWG 115 turn coil (For Earthing of pole) |
| 177 | Chemical Earthing( complete set) |
| 178 | Plate Earthing |
| 179 | LT Fuse set (complete) with REC standard |
| 180 | Cutting plier 8 inch long of IS specification (6149-1984 grade II) |
| 181 | 11KV GI pin confirming to REC construction standard C-1 |
| 182 | M-16 GI Nut and bolt (full threaded) of IS :1387 (PartIi) Gr-4/4.6 |
| 183 | LT Stay set (16mm) of REC specification |
| 184 | LT Stay set (20mm) of REC specification |
| 185 | 11KV Pin Insulator (Porcelain type) IS 731 and Is 3188 |
| 186 | Guy Strain insulator (IS-5300) |
| 187 | Dhoti cloth |
| 188 | 3 phase, 4 wire Prodigy energy meter for DT of IS standard as per REC standard |
| 189 | 11 kV, G.O AB Switch , 3-phase, 200A |
| 190 | 11 kV, G.O AB Switch , 3-phase, 400A |
| 191 | Clamp tester upto 2-5KV |
| 192 | Battery 12V 150Ah of reputed company make like Exide etc. |
| 193 | Battery 12V 180Ah of reputed company make like Exide etc. |
| 194 | Galvanised nuts & bolts of sizes |
| 195 | Bamboo Ladder 10 meter long |
| 196 | 11KV link rod of standard specification |
| 197 | Safety Gloves of Standard make with working potantial 11KV |
| 198 | Safety Helmat of standard make |
| 199 | Saftey Jacket with reflector |
| 200 | Electric Saftey Shoes suitable for 11KV (Shock proof) |
| 201 | Chargable Torch |
| 202 | 11KV meggar for nominal test voltage upto 0.5KV of IS standard make |
| 203 | 11KV meggar upto 5KV of IS standard make |
| 204 | 11KV meggar upto 2.5KV of IS standard make |
| 205 | 11KV meggar upto 1KV of IS standard make |
| 206 | 11KV Spacer |
| 207 | Fault passage Indicator |
| 208 | Safety Belt of standard make |
| 209 | GI U Clamps |
| 210 | MS U Clamps |
| 211 | Mukhi Clamps for LT Shackle insulators |
| 212 | Meter Sealing |
| 213 | Key Set (D-Type) |
| 214 | Key Set (Spanner) |
| 215 | Cutting Pliers |
| 216 | Screw driver |
| 217 | Battery Lead (Terminal) |
| 218 | Bulb 100 Watt |
| 219 | Bulb 60 Watt |
| 220 | Rodometer |
| 221 | 1.5Sqmm Multistand Copper Wire |
| 222 | 2.5 Sqmm Multistand Copper Wire |
| 223 | MS Clamp of Size (50x8)mm suitable for 9mtr ST pole |
| 224 | MS Clamp of Size (50x8)mm suitable for 8mtr ST pole |
| 225 | MS Clamp of Size (40x6mm) Suitable for 8mtr pole |
| 226 | Flexible wire 40/76, 2 core PVC Copper wire |
| 227 | 25KVA , 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate |
| 228 | 63KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate |
| 229 | 100KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate |
| 230 | 200KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate |
| 231 | 250KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate |
| 232 | 400KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate |
| 233 | 630KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate |
| 234 | 3P4W LT Line Spacer |
| 235 | 2P3W LT Line Space |
| 236 | 1P2W LT Line Space |
| 237 | Anticlimbing Device |
| 238 | Danger Plate with Clamp |
| 239 | Battery Charger 12Volts |
| 240 | Battery Charger 24Volts |
| 241 | Decorated light (Laddi) of different colours |
| 242 | Decorated light (Laddi) Tri Colour |
| 243 | Buld Holder of reputed make company |
| 244 | S S Combine Box |
| 245 | 6 Ampere Socket of reputed make company |
| 246 | 15 Ampere Socket of reputed make company |
| 247 | Extension Cord (16 Amp) |
| 248 | Extension Cord (6 Amp) |
| 249 | Single Phase Meter (as per REC Standard) of IS Standard. |
| 250 | Earth Tester (Earthing rod -03 Nos) |
| 251 | Single core Cable Kit |
| 252 | Transformer Oil (suitable for Distribution Transformer/Power Transformer) |
| 253 | Coolant |
| 254 | M.Oil (20w40) |
| 255 | M.Oil (15w40) |
| 256 | M.Oil (15w40) CI4+ |
| 257 | Grease |
| 258 | Chainlink Fencing of 6ft height suitable for 11KV Substation |
| 259 | (a) Iron Mesh in sqft |
| 260 | (b) Angle Iron (fabricated structure as per site requirement) in kgs |
| 261 | DO Fuse Set |
| 262 | PP Rope |
| 263 | Earthing Rod |
| 264 | Discharge Rod |
| 265 | Clamp Meter of reputed make company (Mothwani make) |
| 266 | 11kV Voltage detector |
| 267 | 3Ph3 Wire HT CT/PT operated Fully static Smart Tri-Vector Energymeters DLMS Compliant Category 'C' with RS232 port for modem compatibility. 11kV/110V, Ph-Ph (3P,3W) meters for measurement of different electrical parameters including Active Energy (kWh/ MWh), Reactive Energy (kVArh/MVArh), Apparent Energy (kVAh/ MVAh) etc. (make L&T, Secure, ABB) |
| 268 | Metering Cubical having CT & PT unit CTR/PTR will be communicated at the time of placement of order |
| 269 | Insulating Piercing Connector |
| 270 | 3 Phase SMDB of 200A |
| 271 | Jointing Kit 35sqmm |
| 272 | Jointing Kit 50sqmm |
| 273 | Jointing Kit 95sqmm |
| 274 | Jointing Kit 70sqmm |
| 275 | Jointing Kit 120sqmm |
| 276 | Jointing Kit 185sqmm |
| 277 | 63A TPN MCCB |
| 278 | 100A TPN MCCB |
| 279 | 200A TPN MCCB |
| 280 | 400A TPN MCCB |
| 281 | LT Distribution Box for 100KVA DTR with MCCB for incommer & SFU's for outgoing circuit |
| 282 | LT Distribution Box for 250KVA DTR with MCCB for incommer & SFU's for outgoing circuit |
| 283 | LT Distribution Box for 250KVA DTR with MCCB for incommer & SFU's for outgoing circuit |
| 284 | LT Distribution Box for 250KVA DTR with MCCB for incommer & SFU's for outgoing circuit |
| 285 | LT Distribution Box for 250KVA DTR with MCCB for incommer & SFU's for outgoing circuit |
| 286 | LT Distribution Box for 250KVA DTR with MCCB for incommer & SFU's for outgoing circuit |
| 287 | SMDB, 415V AC LV Distribution Box for 3-Phase AB Cable |
| 288 | Double pole structure on 11KV line for installation of Auto Voltage Boosters/Auto Line Sectionalizer |
| 289 | 11KV HT metering CT and PT opereated (Annexure ''A'') |
| 290 | Supply of fabricated Rectangular Frame made up of Angle Iron(of size 50x6mm) of dimension 6x6feet and fixed with GI wire mesh (2x2\\") painted with 02(two) coats of Aluminium paint. The fabricated frames at the corner ends have additional Angle iron legs of length 1.5feet for grouting in cement concrete with the groud. Please Enable Macros to View BoQ information |