| 1 | Rewinding of ceiling fan motor (starting and running winding) including all necessary material. The motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enamelled wire with 'E' class insulation material and making connections etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. (New model ceiling fan) |
| 2 | 900/1200 mm sweep (New model ceiling fan) |
| 3 | 1400 mm sweep (New model ceiling fan) |
| 4 | All sizes (Old model ceiling fan) |
| 5 | Labour charges for removing and refixing of Ceiling fan/ Exhaust fan from site |
| 6 | Charges for oiling, overhauling of ceiling fan, table fan, pedestal fan irrespect to the size of fan including removing,refixing of fan from site and testing etc. as required. |
| 7 | Fans w/o Removing & Refixing |
| 8 | Fans with Removing & Refixing at Suitable Location |
| 9 | Providing and Replacement of ball bearing of ceiling/ exhaust fan and refixing the same at suitable location as requiredand as per OEM recommendations. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material shall be retained by the contractor. |
| 10 | Provinding & Replacement of M.S. Shaft of ceiling fan. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 11 | P & Replacement of cover/ bearing seat of ceiling/ exhaust fan. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 12 | P & F Aluminium Blades (a set of 3 blades) duly painted and well finished 900/ 1200 mm. The material of the fan blade shall be of designation 31500B with condition HX6 aluminium alloy sheet confirming to IS 737/2008 |
| 13 | Providing and Replacement of Gun metal bush of ceiling/exhaust/cooler fan/ as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 14 | P & F 3 Speed rotary switch for Desert Cooler complete with testing etc as required. |
| 15 | P & Replacement of M.S. Shaft of fan motor for Desert Cooler/ exhaust fan. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 16 | P & replacement of supporting legs(4 no.) of vertical pump of desert cooler as required for Desert Cooler/ exhaust fan. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 17 | P & F of stud with nuts and washer for Desert Cooler/ exhaust fan.All the scrap material should be retained by the contractor. |
| 18 | Servicing and overhauling of 20\\" sweep desert cooler including oiling, greasing, painting of tank from inside with rubber paint after properly desmantling each assembly and refixing the same as required. |
| 19 | Painting of desert cooler with two coats of rubber paint inside of water tank and two coat of synthetic enamelled paint on both side of cooler body, fan body, grills etc.after cleaning with sand paper, complete in all respect as required. |
| 20 | Replacement of cooler pads (heavy) set of 3 no. of size 25\\" x 27\\" |
| 21 | P & F Brass float valve of weighing approx. 250 gm, 8\\" long rod,PVC ball of 4\\" dia. For desert coler as required. |
| 22 | P & F adjustable M.S.grill 20/22 gauge of size approx. 24\\" x 26\\" including painting etc. as required. |
| 23 | P & F aluminiun blade for 20'' desert cooler fan as required. |
| 24 | P & F outer/inner threaded PVC nipple 1/2\\" dia and 2\\" long |
| 25 | P & Replacement of pvc pipe of 1/2\\" size for vertical pump of desert cooler as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 26 | P & replacement of shaft for vertical pump of desert cooler as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 27 | Spray painting of ceiling fan of size 900/1200/ 1400/ 1500 mm with two coats of white/ brown enamelled paint after cleaning with sand paper. Filling etc. as required. |
| 28 | P & replacement of 4 nos. supporting legs of 20'' fan motor with rubber pads of desert cooler as required.Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 29 | P & replacement of high quality pvc distribution ' T 'and 3 no. elbow for cooler |
| 30 | P & F ISI marked waterproof plywood 6.0 mm thick including cutting, hardwares etc. as required. |
| 31 | Labour Charges for fixing of desert cooler in windows including handling of cooler upto desired location, making electrical/water connection s,testing etc. as required. |
| 32 | Ground floor |
| 33 | First floor |
| 34 | Second floor |
| 35 | P & F of ISI marked vertical pump suitable for 20\\" desert cooler including making connection testing etc. as required. |
| 36 | P & F of submercible pump set suitable for 18/24 \\"Desert coolers. |
| 37 | P & F of submercible pump set suitable for 36 \\"Desert coolers. |
| 38 | P & F cooler fan motor suitable for 20\\" desert cooler including making connection testing etc. as required. |
| 39 | with copper winding Motor ISI Marked |
| 40 | with Aluminium winding Motor ISI Marked |
| 41 | Rewinding of Heavy duty Exhaust fan motor including all necessary material,The motor is to be wound taking no. of coils,turns and pitch as it was originally wound with required size super enamelled wire with 'E' class insulation material and making connections etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 42 | 300/ 380 mm sweep |
| 43 | 450 mm sweep |
| 44 | 600 mm sweep |
| 45 | Rewinding of single phase motor of 1400 RPM including all necessary material and of the same characteristics as original with required size of super enamelled wire 'E' class insulation material and testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 46 | 0.25 H.P. To 0.50 H.P. |
| 47 | 0.75 H.P. To 1.0 H.P. |
| 48 | 2.0 H.P. |
| 49 | Rewinding of three phase squirrel cage induction motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original with required size of super enamelled wire 'E' class insulation material and testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 50 | 3.0 H.P. |
| 51 | 5.0 H.P. |
| 52 | Rewinding of motor of desert cooler pump with super enamelled copper wire, 'E ' class insulation material including removing,refixing,testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 53 | Rewinding of motor of desert cooler fan with super enamelled copper wire, 'E ' class insulation material including removing,refixing,testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 54 | Supplying and charging of fresh refrigerant and testing of performance of air conditioner/ fridge/ water cooler of following capacity including capallary and strainer/ filter. |
| 55 | 1.0 TR Window/ Split A.C. |
| 56 | 1.5 TR Window/ Split A.C. |
| 57 | 2.0 TR Window/ Split A.C. |
| 58 | 25/50 / 40/80 Ltr. Water cooler |
| 59 | 60/120 Ltr. Water cooler |
| 60 | 150/150 Ltr. Water cooler |
| 61 | Replacement of defective compressor by company repaired compressor as per OEM recommendations of following gadgets including testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 62 | 1.0 TR A.C. |
| 63 | 1.5 TR A.C. |
| 64 | 2.0 TR A.C. |
| 65 | 2.5 TR A.C. |
| 66 | 3.0 TR A.C. |
| 67 | 4.0 TR A.C. |
| 68 | 25/50 / 40/80 Ltr. Water cooler |
| 69 | 60/120 Ltr. Water cooler |
| 70 | 150/150 Ltr. Water cooler |
| 71 | P & Replacement of condensing/ cooling coil of copper fins for following capacity A.C./ Water cooler/ Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 72 | 1.0 TR A.C. |
| 73 | 1.5 TR A.C. |
| 74 | 2.0 TR A.C. |
| 75 | 25/50 / 40/80 Ltr. Water cooler |
| 76 | 60/120 Ltr. Water cooler |
| 77 | 150/150 Ltr. Water cooler |
| 78 | Servicing of 1.0/1.5/2.0 TR capacity Split/ Window type air conditioner |
| 79 | P & Replacement of overload protection of A.C./ Water cooler as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 80 | P & Replacement of thermostat of A.C./ Water cooler/fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 81 | P & Replacement of selector switch of 1.0/1.5/2.0 TR A.C Fan as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 82 | P & Replacement of starting relay of A.C/water cooler/fridge compressor as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 83 | P & Replacement of door liner of 165/200 Ltr. Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 84 | P & Replacement of main liner of 165/200 Ltr. Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 85 | P & Replacement of door gasket of 165/200 Ltr. Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 86 | P & Replacement of PVC/ acrylic vegetable basket of 165/200 Ltr. Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 87 | Rewinding of single phase/3phase submersible motor including all necessary material and of the same characteristics as original with required size of super enamelled wire 'E' class insulation material and testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 88 | Above 3.0 HP to 5.0 HP |
| 89 | From7. 5 HP to 10.0 HP |
| 90 | Repairing of submersible pump of with replacement of broken impellers ,diffuser,bush/bearing set , oil seal complete with testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 91 | Above 3.0 HP to 5.0 HP |
| 92 | From7. 5 HP to 10.0 HP |
| 93 | Dismentling of split air conditioner of any capacity/any type including existing indoor unit & outdoor unit , refrigerant piping , connecting cables , drain pipe etc. including shifting of dismentaled material to store complete as required |
| 94 | Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size. |
| 95 | 6.0 Sq. mm |
| 96 | 4 core |
| 97 | 35.0 Sq. mm |
| 98 | 3.5 core |
| 99 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism , energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. |
| 100 | Single pole MCB (With B / C curve tripping characteristics) |
| 101 | 6 A to 32 A rating |
| 102 | Four pole MCB (With B / C curve tripping characteristics) |
| 103 | 40 A rating |
| 104 | 50/63 A rating |
| 105 | SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation from 50 to 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle ( to be paid extra) , including making connections etc. as required. OEM shall have submit NABL / CPRI / ERDA/ Intertek accrediated lab type test certificate. |
| 106 | 4 pole MCCB With Thermal Magnetic release |
| 107 | up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting |
| 108 | up to 100 Amp , 25 kA, adjustable O/L & Fixed S/C setting, |
| 109 | 125 Amp , 25 kA, adjustable O/L & Fixed S/C setting, |
| 110 | 160 Amp , 25 kA, adjustable O/L & Fixed S/C setting, |
| 111 | 200 Amp , 25 kA, adjustable O/L & Fixed S/C setting, |
| 112 | 250 Amp , 25 kA, adjustable O/L & adjustable S/C setting, |
| 113 | Providing & Fixing of BEE Star rated copper wounded with class of Insulation 'F', double ball bearing capacitor start, aluminium body & aluminium blade ceiling fan conforming to all the performance requirements laid down in IS 374:2019 with down rod up to 30 cm with secondary support safety cable ( steel rope) , cotter pin, shackle kit with 3 x 1.5 sq.mm pvc insulated flexible copper conductor and making connection testing etc. as required. |
| 114 | 1200 mm sweep with Air delivery >/= 230 CMM and Service Value 8.20 |
| 115 | 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) |
| 116 | SITC of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output only at CW (5700K to 6500K) , internal surge protection of 4.0 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 117 | 1170mm(+/-10%) LED batten with min. lumen output 2200 lm |
| 118 | SITC of IP-20 LED Recessed / Surface Mounted, Round / Square backlit & SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS compliance 4.0 KV surge protected Isolated driver, with Short & Open circuit protection input 320VAC-48 hr protection, input 350VAC-2 hr protection), having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt,at CW (5700K to 6500K) , THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 119 | Recessed Mounting |
| 120 | Minimum lumen output 1300 lm |
| 121 | Minimum lumen output 1950 lm |
| 122 | Surface Mounting (with extruded alumn. Housing ) |
| 123 | Minimum lumen output 1600 lm |
| 124 | Minimum lumen output 1950 lm |
| 125 | SITC of IP20, 2'x2' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmissivity UV stabilized Non -yellowish diffuser for uniform light distribution. operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V . High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection ( input 320VAC-48 hoursprotection,input 350VAC-2 hours protection) (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 126 | Recessed Mounting |
| 127 | Minimum lumen output 4320 lm |
| 128 | Surface Mounting (Driver should be Inside the Luminaire) |
| 129 | Minimum lumen output 4320 lm Please Enable Macros to View BoQ information |