| 1 | Schedule-A Civil Works Excavation |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil. |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. Ordinary rock |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. Hard rock (blasting prohibited) |
| 5 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:1½:3 (1 Cement: 1½ coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form work for : |
| 9 | Foundations, footings, bases of columns, etc. for mass concrete |
| 10 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 11 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 12 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. : |
| 13 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 14 | Mild steel and Medium Tensile steel bars |
| 15 | Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength at all levels in : Cement mortar 1:4 (1 cement : 4 Coarse sand) |
| 16 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand) |
| 17 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 18 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. |
| 19 | Concrete of M25 grade with minimum cement content of 330 kg /cum for all works up to plinth level |
| 20 | Concrete of M25 grade with minimum cement content of 330 kg /cum for all works above plinth level up to floor level V |
| 21 | Dismantling precast concrete or stone slabs in walls, partition walls etc. including stacking within 50 metres lead :thickness 100 mm |
| 22 | Fencing with angle iron post fixed on boundary wall with nets in the embbeded bolts at specified distance and provided with horizontal lines of G.I. barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of iron posts and nuts be paid for separately under Item No. 11). Payment to be made per metre cost of total length of barbed wire used. |
| 23 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 300 mm dia. R.C.C. pipe |
| 24 | Supply of Hydraulic Excavator (3D) with driver & Fuel for 8 hours of duty cycle excluding lunch period. |
| 25 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 600 mm dia. R.C.C. pipe |
| 26 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 250 mm dia. R.C.C. pipe |
| 27 | Supply of Mobile crane, operator & fuel for 8 hours of working hour per day excluding lunch period |
| 28 | Supply of Tractor with tripping trolly, driver & Fuel for 8 hours of duty cycle excluding lunch period. |
| 29 | Providing, laying and fixing in wall for drainage of water through wall, complete as per direction of EIC |
| 30 | P/L 250 mm diameter PVC pipe 4kg/cm2 |
| 31 | P/L 200 mm diameter PVC pipe 4kg/cm2 |
| 32 | P/L 160 mm diameter PVC pipe 4kg/cm2 |
| 33 | P/L 110 mm diameter PVC pipe 4kg/cm2 |
| 34 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1 :6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with: Cement mortar 1 :6 (1 cement : 6 coarse sand) |
| 35 | Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like. Cement mortar 1 :6 (1 cement: 6 coarse sand) |
| 36 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gm/ m² |
| 37 | Providing and laying 50mm thick PUF(Polyurethane Foam) Roofing panel consisting of a 0.5-0.6 mm thick hot dipped high tensile galvanized steel/galvalume sheets which is colour coated with Architectural Polyester, Silicon Modified Polyester, Fluoropolymer or Plastisol whereas the other side of sheet be plain with colour coating. Polyols and Isocyanates are injected between two colour coated metallic sheets kept apart for maintaining the desired thickness. The chemicals shall essentially be free from chlorofluorocarbons. The Polyurethane foam thus formed shall be closed cell. Each panel is to be completed with tongue and groove joint and to be provided with or without camlocks or as per EIC instruction to ensure rigid interlocking between two panels. Panel material should conform to specification as mentioned in IS 16203:2016 |
| 38 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y/U’ shaped placed 2.4m or 3.00 m apart and with 4 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 39 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-incharge: Made of G.I. wire of dia 4 mm |
| 40 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1 :2 (1 cement hardener mix : 2 graded stone aggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 41 | Providing and laying damp-proof course 50 mm thick with cement concrete 1 :2:4 (1 cement: 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 42 | Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces |
| 43 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete: Electric resistance or induction butt welded tubes purlins |
| 44 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats |
| 45 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution |
| 46 | Providing and fixing CRS Sheet of standard IS 513 having yield strength of 240 MPC and 0.5 mm thick with galvanized as per IS 277/GIS 3302 of sheet 0.47 TCT zinc coating of 120 GSM both side mass painted as per IS 14246 RMP tolerance of 0.03 as per IS 513 of colour off white,green,light blue of wide 1.06 m semi corrugated sheets in curves as required plans with double \\"E\\" fastener of required size of make of UTTAM galvanized or self threading Main truss |
| 47 | Providing and laying SBR Polymer modified (of approved make @ minimum 2% by wt. of cement used) plain/reinforced concrete jacket for the structural members e.g. columns, pillars, piers, beams etc with concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] with specified average thickness all-round existing core of RCC member. Note: Rates shall be for finished surface area of concrete and shall include the cost of making holes in existing RCC slab, if required, for pouring concrete in shuttering mould of jacket and appropriate approved Super-Plasticiser for rendering concrete as flowable self compacting and SBR polymer but shall exclude cost of reinforcement, bond coat, Shear Keys, centering and shuttering, strutting, propping etc (Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument) 50 mm thick in Grade M25 with cement content not less than 330 kg per cum |
| 48 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing,paneling and dash fasteners to be paid for separately) :For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 49 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .(Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.0 mm thickness (weight not less than 12.5kg/sqm) |
| 50 | Schedule-B Electrical WorksProviding and laying 1.5 sq. mm ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cable |
| 51 | 1.5 Sq. mm |
| 52 | 2.5 Sq. mm |
| 53 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 54 | 20mm dia. |
| 55 | 25mm dia. |
| 56 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 57 | 1 or 2 Module (75mmX75mm) |
| 58 | 4 Module (125mmX75mm) |
| 59 | 6 Module (200mmX75mm) |
| 60 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 61 | 5/6 amps switch |
| 62 | 15/16 amp switch |
| 63 | 3 pin 5/6 amp socket outlet |
| 64 | 6 pin 15/16 amp socket outlet |
| 65 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 66 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 67 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 68 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 69 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 70 | Supplying and fixing of 20W Luminous LED Bulb, Complete in all respect with the entire satisfaction of Engineer-in-Charge. (Make of fixture Havells, Philips, Syska, Bajaj, wipro or equivalent as per specification with approval of EIC ). |
| 71 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) 40 watt |
| 72 | Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.1050mm, service value ≥ 5.1 CM/Min/Watt, air delivery 150 CM/Min (Minimum) |
| 73 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) Please Enable Macros to View BoQ information |