Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Extension of ADC, Miao Sub-Division office building |
| 2 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30cm size, saturated soil and rock), lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returing the stacked soil in 15cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 3 | Re-filling excavated earth in foundations and plinth etc. in 15cm layer including ramming and watering etc. complete. |
| 4 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 5 | Providing and laying in foundations and plinth cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) excluding the cost of centring and shuttering. |
| 6 | Providing and laying damp proof course 38mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 12.5 mm nominal size) |
| 7 | Extra for providing and mixing water proofing material in cement concrete work in the proportion recommended by manufacturers. |
| 8 | Applying a coat of hot bitumen (mashphalte 80/100 or equivalent) using 1.70 kg. per sqm. on damp proof course after cleaing the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 9 | Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth. |
| 10 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in: M20 (1 cement : 1.5 cparse samd : 3 stone aggregate 20mm nominal size) |
| 11 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1:3 (1 cement : 3 fine sand) of thickness not exceeding 6mm to give a smooth and even surface but excluding cost of centring, shuttering and reinforcement. a. M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20mm nominal size). |
| 12 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1:3 (1 cement :3 fine sand) of thickness not exceeding 6mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a. M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20mm nominal size). |
| 13 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size) |
| 14 | Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20mm nominal size) |
| 15 | Centring and shuttering including strutting, propping etc. and removal of form work for: Foundation, footings, bases of columns etc. and mass concrete. |
| 16 | Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5m height) |
| 17 | Lintels, beams, girders, bressumers and cantilevers etc. |
| 18 | Column, pillars, posts and struts etc. |
| 19 | Stairs (excluding-Landings)----Waist slabs |
| 20 | Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/ TMT steel |
| 21 | Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand). |
| 22 | Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level. |
| 23 | Half brick masonry (with best available local bricks) in cement mortar 1:4 (1cement: 4 coarse sand) in foundation and plinth. |
| 24 | Grading Roof for water proofing treatment with:Cement Mortar 1:3 (1 cement :3 coarse sand) |
| 25 | Providing gola 75 x 75 mm in cement concrete 1:2;4 ( 1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1 : 3 ( 1 cement : 3 fine sand) as per standard design : |
| 26 | Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown or/ and residual bitumen applied hot @ 1.45kg per sqm. of area for each courese, second course of roofing felt type-3 grade-1 (hessian base self finished bitumen felt) and fourth and final course of stone grit 6mm and down size or pea size gravel spread at 6 Cu.dm. per sqm. including preparation of surface excluding grading complete. |
| 27 | Providing and fixing on wall face C.I Rain water pipes including filling the joints with spun yarn soaked in neat cement slurry & cement mortar 1:2.100 mm diameter |
| 28 | Providing and fixing M.S. Holder bat clamps of approved design of C.I. or S.C.I. pipes embedded in and including cement concrete block 10mm x 10cm x 10cm of 1:2:4 mix (1 cement : 2 coarse sand: 4 stone aggregate 20mm nominal size) including cost of cutting holes and making good the wall etc. 100 mm diameter |
| 29 | Providing and fixing on wall face C.I. accessories for rain water pipes including filling the joints with spun yarn soaked in neat cement slurry and cement mortar 1:2 (1 cement : 2 fine sand) b)- CI Plain Bend-100mm dia |
| 30 | b)- CI Plain shoe-100mm dia |
| 31 | Making khurras 45 x 45 cm with avg. minimum thickness of 5 cm cement concrete 1 : 2 : 4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1 mm x 1 m x 400 micron, finished with 12 mm cement plaster 1 : 3 ( 1 cement : 3 coarse sand) and finishing the outlet complete as per drawing. |
| 32 | Providing and fixing flush door shutters, decorative type, core of black board construction with frame of 1st class hard wood and well matched 1st class teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. a) 40mm thick including anodized aluminum butt hinges with necessary screws. |
| 33 | Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size). |
| 34 | Providing and fixing aluminum handles anodised transparent or dyed to required color or shade with necessary screws etc complete. 125 mm |
| 35 | Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete.a) 300 x 10 mm |
| 36 | Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete.a) 300 x 16 mm |
| 37 | Providing and fixing 50 cm long aluminum kicking plate 100x3.15mm anodised, transparent or dyed to required color or shade with necessary screws etc. complete. |
| 38 | Providing and fixing chromium plated finished 100mm mortice latch and lock with 6 levers and a pair of CP handles with necessary screws etc. |
| 39 | Providing and fixing MS Round or Sq bars at required spacing in wooden frames of windows. |
| 40 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 60x60 cm refer carpet area calculation |
| 41 | SKIRTING/ DADO : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 12mm thick cement mortar 1:3 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x600 mm |
| 42 | Providing and fixing 1 st quality ceramic glazed wall tiles confirming to IS: 15622 ( thickness to be specified by manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any sizes as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 Cement : 3 Coarse sand) and joining with grey cement slurry @3.30kg per sqm including pointing with white cement mixed with pigment of matching shade complete. |
| 43 | Providing and laying gang saw cut 18 mm thick, mirror polished premoulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge.With granite stone of area less than 0.50 sqm |
| 44 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a approved steel priming coat using structural steel as required in gratings, frames, guard bars, railings, brackets, gates, grills etc. |
| 45 | Providing & fixing Hand Rail of approved size by welding etc to steel ladder railing, balcony railing, staircase railing & similar works, including applyingnpriming coat of approved steel primer : E.R.W Tube |
| 46 | Door /Window / Ventilator Frames:- Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2 mm). Both verticalssides of the frame reinforced with PVC profile of cross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm) and 75 mm x 200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut, jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturer's specification and direction of engineer- in-charge |
| 47 | 12 mm thk cement plaster 1: 4( 1 cement : 4 coarse sand) on walls. |
| 48 | 15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement :4 fine sand) |
| 49 | Applying one coat of cement primer of approved brand and manufacture on wall surface. |
| 50 | Finishing walls with water proofing cement paint of required shade : |
| 51 | Wall painting (two or coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade. |
| 52 | Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works. |
| 53 | With ready mixed pink primer of approved brand and manufacture on resinous wood and plywood works. |
| 54 | painting with synthetic enamel paint of approved brand and manufacture to give an even shade- 2 or more coats |
| 55 | Painting (two or more coats) on rain water, soil waste and vent pipes and fittings with aluminum paint of approved quality over a priming coat of ready mixed genuine red lead on new work. |
| 56 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) :Anodised Aluminium (anodised transparant or dyed to required shade according to IS:1868, minimum anodic coating of grade SC-15) |
| 57 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge. (Cost of aluminium snap beading shall be paid in basic item)With float glass panes of 5.5 mm thickness. |
| 58 | Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-incharge complete.255 X 19 mm. |
| 59 | ELECTRICAL WORKS |
| 60 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 61 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 62 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (For Light Ckt & Light plug) |
| 63 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair |
| 64 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 65 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm25 mm |
| 66 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet |
| 67 | TV antenna socket outlet |
| 68 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 69 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 70 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm) |
| 71 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 72 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 73 | Installation, Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 74 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 75 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep |
| 76 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 77 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. For Data & CCTV1 run of cable |
| 78 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC copper conductor single core cable etc. as required. insulated |
| 79 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.(For A.C Units) |
| 80 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 81 | CEILING FANS : Supplying, installation, testing & commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fans with Brushless Direct Current (BLDC) motor, class of insulation B, 3 nos blade, 30cm long down rod, 2 nos canopies, shakel kit, safety rope, copper winding, power factor not less then 0.9, supply earthing etc complete as required |
| 82 | Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCBs & incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required)8 way (4 + 24), Double door |
| 83 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single Pole |
| 84 | Triple pole and neutral |
| 85 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 86 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 87 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 88 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 89 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm |
| 90 | Supplying the following Lighting fixtures including lamps at site. Rate shall include all taxes and duties, transportation etc. complete. (4000 K) (Samples of all light fixtures to be submitted to the client for approval prior to procurement of fixtures)Supply, installation, testing & commissioning of Surface mounted Linear type 4ft 18W Led fitting delivering an initial lamp lumen of 2000 lumens & the luminaire shall be with system efficacy ≥ 100 lm / W. Housing: Polycarbonate . IP20 , Optics: Polycarbonate Diffuser. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 20% & PF ≥ 0.95. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard. Wipro Cat No.: LL20-2021-xxx-65 NE |
| 91 | Supply, installation, testing & commissioning of Surface mounted Linear type 2ft 10W Led fitting delivering an initial lamp lumen of 2000 lumens & the luminaire shall be with system efficacy ≥ 100 lm / W. Housing: Polycarbonate . IP20 , Optics: Polycarbonate Diffuser. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 20% & PF ≥ 0.95. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard. Wipro Cat No.: LL20-2021-xxx-65 NE |
| 92 | Supply of 10\\" dia 1 phase exhaust fan, 900 RPM |
| 93 | 48\\" dia (1200 sweep) double ball bearing ceiling fan Crompton/Usha/ Havels |
| 94 | PHILIPS, 15W, Polycarbonate, Edge Glow Surface LED Downlighter with 270 degree light spread, 1500 lumen, 6500k, 102mm Dia |
| 95 | PLUMBING WORKS |
| 96 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid,10 litre low level white vitreous china flushing cistern & C.P flush bend with fitting & C.I brackets,40mm flush bend,overflow arrangement with special of standard make and mosquito proof coupling of approved municipal design complete including painting of fitting and bracketss,cutting and making good the walls and floors wherever required.W.C pan with ISI marked white solid plastic seat and lid. |
| 97 | Providing and fixing white vitreous china wash basin with C.I./M.S. brackets, 15 mm CP brass pillar taps, 32 mm CP brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required :Flat back wash basin size 550x450 mm with a single 15 mm CP pillar tap |
| 98 | Providing and fixing Stainless steel A ISI 304(18/8) Kitchen sink as per IS:13983 with CI Brackets and stainless steel plugs 40mm, including painting of fittings and brackets, cutting & making good the walls where ever required.Kitchen sink with drainboard, 510 x 1040mm with bowl depth 250mm |
| 99 | Providing and fixing CP Brass Waste for wash basin and sinks.40mm dia |
| 100 | Providing and fixing MI fisher union for wash basin and sinks.40mm dia |
| 101 | Providing and fixing CP Brass or MI trap for wash basin and sinks.b) 40 mm dia |
| 102 | Providing and fixing rubber plug for sink or wash basin. |
| 103 | Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleats with CP brass screws and washers. |
| 104 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes.100 mm dia |
| 105 | Providing and fixing sand cast iron heel rest sanitary bend.100 mm |
| 106 | Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100 x100x100 mm |
| 107 | Providing and fixing sand cast iron trap of self cleaning design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors.a) 100 mm inlet and 100 mm outlet |
| 108 | Painting sand cast iron soil spun soil waste vent pipes and fittings with paint of any color such as chocolate, grey or buff etc over a coat of primer (of approved quality) for new work.100 mm diameter pipe |
| 109 | Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good the walls etc. (internal work)20 mm dia nominal bore |
| 110 | 25 mm dia nominal bore |
| 111 | Concealed pipe including painting with anti-corrosive bitumastic paint, cutting chases and making good the wall20 mm dia nominal bore |
| 112 | 25 mm dia nominal bore |
| 113 | Providing and fixing brass full way valve with wheel of approved quality.32 mm nominal bore |
| 114 | Providing and fixing brass stop cock of approved quality complete25 mm nominal bore |
| 115 | Providing and placing on terrace ( at all floor levels ) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 116 | Providing and fixing CP brass bib cock of approved quality conforming to IS : 893120 mm Nominal bore |
| 117 | Providing and fixing ball valve (brass) of approved quality.High or Low presssure with polythelene float : 20 mm Nominal bore |
| 118 | Providing and fixing CP Angle Valve for basin mixtures and geysers points EWC Cisterns of approved quality conforming to IS : 8931 |
| 119 | Providing laying and jointing glazed stone ware pipe grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.150mm diameter |
| 120 | Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15 cm thick as per standard design.250mm |
| 121 | Constructing brick masonry manhole with 2nd class bricks in cement mortar 1: 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design.a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg). |
| 122 | Providing and fixing square mouth SW gully trap class SP-1 complete with CI grating brick masonry chamber and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg. as per standard design.180x150mm size P typeWith common burnt clay FPS(non modular) bricks of class designation 7.5. |
| 123 | Fire Fighting Work |
| 124 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. |
| 125 | 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 1258520 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.Supply, installation, testing and commissioning ISI marked (IS:15683) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 and walll suspension braket as required as per specifications. |
| 126 | Supply, installation, testing and commissioning of 6kg ABC (Powder Type) Fire Extinguisher. Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC 90 powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:15683 as required as per specifications. |
| 127 | Septic Tank |
| 128 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30cm size, saturated soil and rock), lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returing the stacked soil in 15cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 129 | Dry stone pitching 22.50 cm thick including supply of stone and preparing surface complete (including carriage of stone for 5 Km lead). |
| 130 | Providing and laying cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in :a) Foundations and plinth |
| 131 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface with M20 (1:1.5:3 20 mm nominal size) |
| 132 | Centring and shuttering including strutting, propping etc and removal of form work for :d) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
| 133 | Reinforcement of RCC work including bending, binding and placing in position complete.a) Cold twisted bars. |
| 134 | Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand). |
| 135 | 12 mm cement plaster 1 : 3 (1 cement : 3 fine sand). In Plinth wall. |
| 136 | Providing laying and jointing glazed stone ware pipe grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.a) 150 mm dia SW pipes |
| 137 | Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15 cm thick as per standard design. a) 150 mm dia SW pipes |
| 138 | Construction of soak pit 1.5 x 1.2 x 1.5 m filled with brick bats including SW drain pipe 100 mm dia and 1.20 m long complete as per standard design. |
| 139 | Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work).b) 20 mm nominal bore |
| 140 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work).a) 32 mm niminal bore |
| 141 | b) 20 mm nominal bore |
| 142 | c) 25 mm nominal bore |
| 143 | providing and fixing PVC trap of approved quality.a) 50 mm |
| 144 | Providing and fixing Chlorinated Polyvinyl Chloride(CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain and brass threaded fittings this includes jointing of pipes & fittings with one step CPVC solvent cement trenching, refilling & testing of joints complete as per direction of Engineer Incharge.a) External worki) 50 mm dia |
| 145 | ii) 75 mm dia |
| 146 | Providing & fixing steel nahani trap floor drain for WC |
| 147 | Providing & fixing PVC elbow for PVC pipe fitting. |
| 148 | Providing and fixing sand cast iron soil, waste and vent pipe.b) 75 mm dia |
| 149 | Type-V [ADC Bungalow] |
| 150 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30cm size, saturated soil and rock), lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returing the stacked soil in 15cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 151 | Re-filling excavated earth in foundations and plinth etc. in 15cm layer including ramming and watering etc. complete. |
| 152 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 153 | Providing and laying in foundations and plinth cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) excluding the cost of centring and shuttering. |
| 154 | Providing and laying damp proof course 38mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 12.5 mm nominal size) |
| 155 | Extra for providing and mixing water proofing material in cement concrete work in the proportion recommended by manufacturers. |
| 156 | Applying a coat of hot bitumen (mashphalte 80/100 or equivalent) using 1.70 kg. per sqm. on damp proof course after cleaing the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 157 | Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth. |
| 158 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in: M20 (1 cement : 1.5 cparse samd : 3 stone aggregate 20mm nominal size) |
| 159 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1:3 (1 cement : 3 fine sand) of thickness not exceeding 6mm to give a smooth and even surface but excluding cost of centring, shuttering and reinforcement. a. M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20mm nominal size). |
| 160 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1:3 (1 cement :3 fine sand) of thickness not exceeding 6mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a. M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20mm nominal size). |
| 161 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size) |
| 162 | Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20mm nominal size) |
| 163 | Centring and shuttering including strutting, propping etc. and removal of form work for: Foundation, footings, bases of columns etc. and mass concrete. |
| 164 | Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5m height) |
| 165 | Lintels, beams, girders, bressumers and cantilevers etc. |
| 166 | Column, pillars, posts and struts etc. |
| 167 | Stairs (excluding-Landings)----Waist slabs |
| 168 | Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/ TMT steel |
| 169 | Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand). |
| 170 | Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level. |
| 171 | Half brick masonry (with best available local bricks) in cement mortar 1:4 (1cement: 4 coarse sand) in foundation and plinth. |
| 172 | Grading Roof for water proofing treatment with:Cement Mortar 1:3 (1 cement :3 coarse sand) |
| 173 | Providing gola 75 x 75 mm in cement concrete 1:2;4 ( 1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1 : 3 ( 1 cement : 3 fine sand) as per standard design : |
| 174 | Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown or/ and residual bitumen applied hot @ 1.45kg per sqm. of area for each courese, second course of roofing felt type-3 grade-1 (hessian base self finished bitumen felt) and fourth and final course of stone grit 6mm and down size or pea size gravel spread at 6 Cu.dm. per sqm. including preparation of surface excluding grading complete. |
| 175 | Providing and fixing on wall face C.I Rain water pipes including filling the joints with spun yarn soaked in neat cement slurry & cement mortar 1:2.100 mm diameter |
| 176 | Providing and fixing M.S. Holder bat clamps of approved design of C.I. or S.C.I. pipes embedded in and including cement concrete block 10mm x 10cm x 10cm of 1:2:4 mix (1 cement : 2 coarse sand: 4 stone aggregate 20mm nominal size) including cost of cutting holes and making good the wall etc. 100 mm diameter |
| 177 | Providing and fixing on wall face C.I. accessories for rain water pipes including filling the joints with spun yarn soaked in neat cement slurry and cement mortar 1:2 (1 cement : 2 fine sand) b)- CI Plain Bend-100mm dia |
| 178 | b)- CI Plain shoe-100mm dia |
| 179 | Making khurras 45 x 45 cm with avg. minimum thickness of 5 cm cement concrete 1 : 2 : 4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1 mm x 1 m x 400 micron, finished with 12 mm cement plaster 1 : 3 ( 1 cement : 3 coarse sand) and finishing the outlet complete as per drawing. |
| 180 | Providing and fixing flush door shutters, decorative type, core of black board construction with frame of 1st class hard wood and well matched 1st class teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. a) 40mm thick including anodized aluminum butt hinges with necessary screws. |
| 181 | Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size). |
| 182 | Providing and fixing aluminum handles anodised transparent or dyed to required color or shade with necessary screws etc complete. 125 mm |
| 183 | Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete.a) 300 x 10 mm |
| 184 | Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete.a) 300 x 16 mm |
| 185 | Providing and fixing 50 cm long aluminum kicking plate 100x3.15mm anodised, transparent or dyed to required color or shade with necessary screws etc. complete. |
| 186 | Providing and fixing chromium plated finished 100mm mortice latch and lock with 6 levers and a pair of CP handles with necessary screws etc. |
| 187 | Providing and fixing MS Round or Sq bars at required spacing in wooden frames of windows. |
| 188 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 60x60 cm refer carpet area calculation |
| 189 | SKIRTING/ DADO : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 12mm thick cement mortar 1:3 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x600 mm |
| 190 | Providing and fixing 1 st quality ceramic glazed wall tiles confirming to IS: 15622 ( thickness to be specified by manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any sizes as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 Cement : 3 Coarse sand) and joining with grey cement slurry @3.30kg per sqm including pointing with white cement mixed with pigment of matching shade complete. |
| 191 | Providing and laying gang saw cut 18 mm thick, mirror polished premoulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge.With granite stone of area less than 0.50 sqm |
| 192 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a approved steel priming coat using structural steel as required in gratings, frames, guard bars, railings, brackets, gates, grills etc. |
| 193 | Providing & fixing Hand Rail of approved size by welding etc to steel ladder railing, balcony railing, staircase railing & similar works, including applyingnpriming coat of approved steel primer : E.R.W Tube |
| 194 | Door /Window / Ventilator Frames:- Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2 mm). Both verticalssides of the frame reinforced with PVC profile of cross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm) and 75 mm x 200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut, jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturer's specification and direction of engineer- in-charge |
| 195 | 12 mm thk cement plaster 1: 4( 1 cement : 4 coarse sand) on walls. |
| 196 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement :4 fine sand) |
| 197 | Applying one coat of cement primer of approved brand and manufacture on wall surface. |
| 198 | Finishing walls with water proofing cement paint of required shade : |
| 199 | Wall painting (two or coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade. |
| 200 | Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works. |
| 201 | With ready mixed pink primer of approved brand and manufacture on resinous wood and plywood works. |
| 202 | painting with synthetic enamel paint of approved brand and manufacture to give an even shade- 2 or more coats |
| 203 | Painting (two or more coats) on rain water, soil waste and vent pipes and fittings with aluminum paint of approved quality over a priming coat of ready mixed genuine red lead on new work. |
| 204 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) :Anodised Aluminium (anodised transparant or dyed to required shade according to IS:1868, minimum anodic coating of grade SC-15) |
| 205 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge. (Cost of aluminium snap beading shall be paid in basic item)With float glass panes of 5.5 mm thickness. |
| 206 | Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-incharge complete.255 X 19 mm. |
| 207 | ELECTRICAL WORKS |
| 208 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 209 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 210 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (For Light Ckt & Light plug) |
| 211 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair |
| 212 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 213 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm25 mm |
| 214 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet |
| 215 | TV antenna socket outlet |
| 216 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 217 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 218 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm) |
| 219 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 220 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 221 | Installation, Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 222 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 223 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep |
| 224 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 225 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. For Data & CCTV1 run of cable |
| 226 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC copper conductor single core cable etc. as required. insulated |
| 227 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.(For A.C Units) |
| 228 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 229 | CEILING FANS : Supplying, installation, testing & commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fans with Brushless Direct Current (BLDC) motor, class of insulation B, 3 nos blade, 30cm long down rod, 2 nos canopies, shakel kit, safety rope, copper winding, power factor not less then 0.9, supply earthing etc complete as required |
| 230 | Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCBs & incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required)8 way (4 + 24), Double door |
| 231 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single Pole |
| 232 | Triple pole and neutral |
| 233 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 234 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 235 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 236 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 237 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm |
| 238 | Supplying the following Lighting fixtures including lamps at site. Rate shall include all taxes and duties, transportation etc. complete. (4000 K) (Samples of all light fixtures to be submitted to the client for approval prior to procurement of fixtures)Supply, installation, testing & commissioning of Surface mounted Linear type 4ft 18W Led fitting delivering an initial lamp lumen of 2000 lumens & the luminaire shall be with system efficacy ≥ 100 lm / W. Housing: Polycarbonate . IP20 , Optics: Polycarbonate Diffuser. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 20% & PF ≥ 0.95. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard. Wipro Cat No.: LL20-2021-xxx-65 NE |
| 239 | Supply, installation, testing & commissioning of Surface mounted Linear type 2ft 10W Led fitting delivering an initial lamp lumen of 2000 lumens & the luminaire shall be with system efficacy ≥ 100 lm / W. Housing: Polycarbonate . IP20 , Optics: Polycarbonate Diffuser. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 20% & PF ≥ 0.95. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard. Wipro Cat No.: LL20-2021-xxx-65 NE |
| 240 | Supply of 10\\" dia 1 phase exhaust fan, 900 RPM |
| 241 | 48\\" dia (1200 sweep) double ball bearing ceiling fan Crompton/Usha/ Havels |
| 242 | PHILIPS, 15W, Polycarbonate, Edge Glow Surface LED Downlighter with 270 degree light spread, 1500 lumen, 6500k, 102mm Dia |
| 243 | PLUMBING WORKS |
| 244 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid,10 litre low level white vitreous china flushing cistern & C.P flush bend with fitting & C.I brackets,40mm flush bend,overflow arrangement with special of standard make and mosquito proof coupling of approved municipal design complete including painting of fitting and bracketss,cutting and making good the walls and floors wherever required.W.C pan with ISI marked white solid plastic seat and lid. |
| 245 | Providing and fixing white vitreous china wash basin with C.I./M.S. brackets, 15 mm CP brass pillar taps, 32 mm CP brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required :Flat back wash basin size 550x450 mm with a single 15 mm CP pillar tap |
| 246 | Providing and fixing Stainless steel A ISI 304(18/8) Kitchen sink as per IS:13983 with CI Brackets and stainless steel plugs 40mm, including painting of fittings and brackets, cutting & making good the walls where ever required.Kitchen sink with drainboard, 510 x 1040mm with bowl depth 250mm |
| 247 | Providing and fixing CP Brass Waste for wash basin and sinks.40mm dia |
| 248 | Providing and fixing MI fisher union for wash basin and sinks.40mm dia |
| 249 | Providing and fixing CP Brass or MI trap for wash basin and sinks.b) 40 mm dia |
| 250 | Providing and fixing rubber plug for sink or wash basin. |
| 251 | Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleats with CP brass screws and washers. |
| 252 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes.100 mm dia |
| 253 | Providing and fixing sand cast iron heel rest sanitary bend.100 mm |
| 254 | Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100 x100x100 mm |
| 255 | Providing and fixing sand cast iron trap of self cleaning design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors.a) 100 mm inlet and 100 mm outlet |
| 256 | Painting sand cast iron soil spun soil waste vent pipes and fittings with paint of any color such as chocolate, grey or buff etc over a coat of primer (of approved quality) for new work.100 mm diameter pipe |
| 257 | Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good the walls etc. (internal work)20 mm dia nominal bore |
| 258 | 25 mm dia nominal bore |
| 259 | Concealed pipe including painting with anti-corrosive bitumastic paint, cutting chases and making good the wall20 mm dia nominal bore |
| 260 | 25 mm dia nominal bore |
| 261 | Providing and fixing brass full way valve with wheel of approved quality.32 mm nominal bore |
| 262 | Providing and fixing brass stop cock of approved quality complete25 mm nominal bore |
| 263 | Providing and placing on terrace ( at all floor levels ) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 264 | Providing and fixing CP brass bib cock of approved quality conforming to IS : 893120 mm Nominal bore |
| 265 | Providing and fixing ball valve (brass) of approved quality.High or Low presssure with polythelene float : 20 mm Nominal bore |
| 266 | Providing and fixing CP Angle Valve for basin mixtures and geysers points EWC Cisterns of approved quality conforming to IS : 8931 |
| 267 | Providing laying and jointing glazed stone ware pipe grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.150mm diameter |
| 268 | Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15 cm thick as per standard design.250mm |
| 269 | Constructing brick masonry manhole with 2nd class bricks in cement mortar 1: 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design.a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg). |
| 270 | Providing and fixing square mouth SW gully trap class SP-1 complete with CI grating brick masonry chamber and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg. as per standard design.180x150mm size P typeWith common burnt clay FPS(non modular) bricks of class designation 7.5. |
| 271 | Type-IV residential Quarter [1 Block-5 Units] |
| 272 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30cm size, saturated soil and rock), lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returing the stacked soil in 15cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 273 | Re-filling excavated earth in foundations and plinth etc. in 15cm layer including ramming and watering etc. complete. |
| 274 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 275 | Providing and laying in foundations and plinth cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) excluding the cost of centring and shuttering. |
| 276 | Providing and laying damp proof course 38mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 12.5 mm nominal size) |
| 277 | Extra for providing and mixing water proofing material in cement concrete work in the proportion recommended by manufacturers. |
| 278 | Applying a coat of hot bitumen (mashphalte 80/100 or equivalent) using 1.70 kg. per sqm. on damp proof course after cleaing the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 279 | Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth. |
| 280 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in: M20 (1 cement : 1.5 cparse samd : 3 stone aggregate 20mm nominal size) |
| 281 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1:3 (1 cement : 3 fine sand) of thickness not exceeding 6mm to give a smooth and even surface but excluding cost of centring, shuttering and reinforcement. a. M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20mm nominal size). |
| 282 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1:3 (1 cement :3 fine sand) of thickness not exceeding 6mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a. M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20mm nominal size). |
| 283 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size) |
| 284 | Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20mm nominal size) |
| 285 | Centring and shuttering including strutting, propping etc. and removal of form work for: Foundation, footings, bases of columns etc. and mass concrete. |
| 286 | Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5m height) |
| 287 | Lintels, beams, girders, bressumers and cantilevers etc. |
| 288 | Column, pillars, posts and struts etc. |
| 289 | Stairs (excluding-Landings)----Waist slabs |
| 290 | Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/ TMT steel |
| 291 | Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand). |
| 292 | Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level. |
| 293 | Half brick masonry (with best available local bricks) in cement mortar 1:4 (1cement: 4 coarse sand) in foundation and plinth. |
| 294 | Grading Roof for water proofing treatment with:Cement Mortar 1:3 (1 cement :3 coarse sand) |
| 295 | Providing gola 75 x 75 mm in cement concrete 1:2;4 ( 1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1 : 3 ( 1 cement : 3 fine sand) as per standard design : |
| 296 | Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown or/ and residual bitumen applied hot @ 1.45kg per sqm. of area for each courese, second course of roofing felt type-3 grade-1 (hessian base self finished bitumen felt) and fourth and final course of stone grit 6mm and down size or pea size gravel spread at 6 Cu.dm. per sqm. including preparation of surface excluding grading complete. |
| 297 | Providing and fixing on wall face C.I Rain water pipes including filling the joints with spun yarn soaked in neat cement slurry & cement mortar 1:2.100 mm diameter |
| 298 | Providing and fixing M.S. Holder bat clamps of approved design of C.I. or S.C.I. pipes embedded in and including cement concrete block 10mm x 10cm x 10cm of 1:2:4 mix (1 cement : 2 coarse sand: 4 stone aggregate 20mm nominal size) including cost of cutting holes and making good the wall etc. 100 mm diameter |
| 299 | Providing and fixing on wall face C.I. accessories for rain water pipes including filling the joints with spun yarn soaked in neat cement slurry and cement mortar 1:2 (1 cement : 2 fine sand) b)- CI Plain Bend-100mm dia |
| 300 | b)- CI Plain shoe-100mm dia |
| 301 | Making khurras 45 x 45 cm with avg. minimum thickness of 5 cm cement concrete 1 : 2 : 4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1 mm x 1 m x 400 micron, finished with 12 mm cement plaster 1 : 3 ( 1 cement : 3 coarse sand) and finishing the outlet complete as per drawing. |
| 302 | Providing and fixing flush door shutters, decorative type, core of black board construction with frame of 1st class hard wood and well matched 1st class teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. a) 40mm thick including anodized aluminum butt hinges with necessary screws. |
| 303 | Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size). |
| 304 | Providing and fixing aluminum handles anodised transparent or dyed to required color or shade with necessary screws etc complete. 125 mm |
| 305 | Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete.a) 300 x 10 mm |
| 306 | Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete.a) 300 x 16 mm |
| 307 | Providing and fixing 50 cm long aluminum kicking plate 100x3.15mm anodised, transparent or dyed to required color or shade with necessary screws etc. complete. |
| 308 | Providing and fixing chromium plated finished 100mm mortice latch and lock with 6 levers and a pair of CP handles with necessary screws etc. |
| 309 | Providing and fixing MS Round or Sq bars at required spacing in wooden frames of windows. |
| 310 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 60x60 cm refer carpet area calculation |
| 311 | SKIRTING/ DADO : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 12mm thick cement mortar 1:3 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x600 mm |
| 312 | Providing and fixing 1 st quality ceramic glazed wall tiles confirming to IS: 15622 ( thickness to be specified by manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any sizes as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 Cement : 3 Coarse sand) and joining with grey cement slurry @3.30kg per sqm including pointing with white cement mixed with pigment of matching shade complete. |
| 313 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x30 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. sqm 1225.10 shades, except White, Ivory, Grey, Fume Red Brown laid on 20mm thick bed of Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete. |
| 314 | Providing and laying gang saw cut 18 mm thick, mirror polished premoulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge.With granite stone of area less than 0.50 sqm |
| 315 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a approved steel priming coat using structural steel as required in gratings, frames, guard bars, railings, brackets, gates, grills etc. |
| 316 | Providing & fixing Hand Rail of approved size by welding etc to steel ladder railing, balcony railing, staircase railing & similar works, including applyingnpriming coat of approved steel primer : E.R.W Tube |
| 317 | Door /Window / Ventilator Frames:- Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2 mm). Both verticalssides of the frame reinforced with PVC profile of cross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm) and 75 mm x 200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut, jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturer's specification and direction of engineer- in-charge |
| 318 | 12 mm thk cement plaster 1: 4( 1 cement : 4 coarse sand) on walls. |
| 319 | 15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement :4 fine sand) |
| 320 | Applying one coat of cement primer of approved brand and manufacture on wall surface. |
| 321 | Finishing walls with water proofing cement paint of required shade : |
| 322 | Wall painting (two or coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade. |
| 323 | Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works. |
| 324 | With ready mixed pink primer of approved brand and manufacture on resinous wood and plywood works. |
| 325 | painting with synthetic enamel paint of approved brand and manufacture to give an even shade- 2 or more coats |
| 326 | Painting (two or more coats) on rain water, soil waste and vent pipes and fittings with aluminum paint of approved quality over a priming coat of ready mixed genuine red lead on new work. |
| 327 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) :Anodised Aluminium (anodised transparant or dyed to required shade according to IS:1868, minimum anodic coating of grade SC-15) |
| 328 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge. (Cost of aluminium snap beading shall be paid in basic item)With float glass panes of 5.5 mm thickness. |
| 329 | Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-incharge complete.255 X 19 mm. |
| 330 | ELECTRICAL WORKS |
| 331 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 332 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 333 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (For Light Ckt & Light plug) |
| 334 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair |
| 335 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 336 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm25 mm |
| 337 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet |
| 338 | TV antenna socket outlet |
| 339 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 340 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 341 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm) |
| 342 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 343 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 344 | Installation, Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 345 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 346 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep |
| 347 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 348 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. For Data & CCTV1 run of cable |
| 349 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC copper conductor single core cable etc. as required. insulated |
| 350 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.(For A.C Units) |
| 351 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 352 | CEILING FANS : Supplying, installation, testing & commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fans with Brushless Direct Current (BLDC) motor, class of insulation B, 3 nos blade, 30cm long down rod, 2 nos canopies, shakel kit, safety rope, copper winding, power factor not less then 0.9, supply earthing etc complete as required |
| 353 | Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCBs & incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required)8 way (4 + 24), Double door |
| 354 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single Pole |
| 355 | Triple pole and neutral |
| 356 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 357 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 358 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 359 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 360 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm |
| 361 | Supplying the following Lighting fixtures including lamps at site. Rate shall include all taxes and duties, transportation etc. complete. (4000 K) (Samples of all light fixtures to be submitted to the client for approval prior to procurement of fixtures)Supply, installation, testing & commissioning of Surface mounted Linear type 4ft 18W Led fitting delivering an initial lamp lumen of 2000 lumens & the luminaire shall be with system efficacy ≥ 100 lm / W. Housing: Polycarbonate . IP20 , Optics: Polycarbonate Diffuser. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 20% & PF ≥ 0.95. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard. Wipro Cat No.: LL20-2021-xxx-65 NE |
| 362 | Supply, installation, testing & commissioning of Surface mounted Linear type 2ft 10W Led fitting delivering an initial lamp lumen of 2000 lumens & the luminaire shall be with system efficacy ≥ 100 lm / W. Housing: Polycarbonate . IP20 , Optics: Polycarbonate Diffuser. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 20% & PF ≥ 0.95. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard. Wipro Cat No.: LL20-2021-xxx-65 NE |
| 363 | Supply of 10\\" dia 1 phase exhaust fan, 900 RPM |
| 364 | 48\\" dia (1200 sweep) double ball bearing ceiling fan Crompton/Usha/ Havels |
| 365 | PHILIPS, 15W, Polycarbonate, Edge Glow Surface LED Downlighter with 270 degree light spread, 1500 lumen, 6500k, 102mm Dia |
| 366 | PLUMBING WORKS |
| 367 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid,10 litre low level white vitreous china flushing cistern & C.P flush bend with fitting & C.I brackets,40mm flush bend,overflow arrangement with special of standard make and mosquito proof coupling of approved municipal design complete including painting of fitting and bracketss,cutting and making good the walls and floors wherever required.W.C pan with ISI marked white solid plastic seat and lid. |
| 368 | Providing and fixing white vitreous china wash basin with C.I./M.S. brackets, 15 mm CP brass pillar taps, 32 mm CP brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required :Flat back wash basin size 550x450 mm with a single 15 mm CP pillar tap |
| 369 | Providing and fixing Stainless steel A ISI 304(18/8) Kitchen sink as per IS:13983 with CI Brackets and stainless steel plugs 40mm, including painting of fittings and brackets, cutting & making good the walls where ever required.Kitchen sink with drainboard, 510 x 1040mm with bowl depth 250mm |
| 370 | Providing and fixing CP Brass Waste for wash basin and sinks.40mm dia |
| 371 | Providing and fixing MI fisher union for wash basin and sinks.40mm dia |
| 372 | Providing and fixing CP Brass or MI trap for wash basin and sinks.b) 40 mm dia |
| 373 | Providing and fixing rubber plug for sink or wash basin. |
| 374 | Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleats with CP brass screws and washers. |
| 375 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes.100 mm dia |
| 376 | Providing and fixing sand cast iron heel rest sanitary bend.100 mm |
| 377 | Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100 x100x100 mm |
| 378 | Providing and fixing sand cast iron trap of self cleaning design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors.a) 100 mm inlet and 100 mm outlet |
| 379 | Painting sand cast iron soil spun soil waste vent pipes and fittings with paint of any color such as chocolate, grey or buff etc over a coat of primer (of approved quality) for new work.100 mm diameter pipe |
| 380 | Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good the walls etc. (internal work)20 mm dia nominal bore |
| 381 | 25 mm dia nominal bore |
| 382 | Concealed pipe including painting with anti-corrosive bitumastic paint, cutting chases and making good the wall20 mm dia nominal bore |
| 383 | 25 mm dia nominal bore |
| 384 | Providing and fixing brass full way valve with wheel of approved quality.32 mm nominal bore |
| 385 | Providing and fixing brass stop cock of approved quality complete25 mm nominal bore |
| 386 | Providing and placing on terrace ( at all floor levels ) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 387 | Providing and fixing CP brass bib cock of approved quality conforming to IS : 893120 mm Nominal bore |
| 388 | Providing and fixing ball valve (brass) of approved quality.High or Low presssure with polythelene float : 20 mm Nominal bore |
| 389 | Providing and fixing CP Angle Valve for basin mixtures and geysers points EWC Cisterns of approved quality conforming to IS : 8931 |
| 390 | Providing laying and jointing glazed stone ware pipe grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.150mm diameter |
| 391 | Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15 cm thick as per standard design.250mm |
| 392 | Constructing brick masonry manhole with 2nd class bricks in cement mortar 1: 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design.a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg). |
| 393 | Providing and fixing square mouth SW gully trap class SP-1 complete with CI grating brick masonry chamber and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg. as per standard design.180x150mm size P typeWith common burnt clay FPS(non modular) bricks of class designation 7.5. |
| 394 | Type-II Residential Quarter [1 Block-12 Unis]- 3 Blocks |
| 395 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30cm size, saturated soil and rock), lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returing the stacked soil in 15cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 396 | Re-filling excavated earth in foundations and plinth etc. in 15cm layer including ramming and watering etc. complete. |
| 397 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 398 | Providing and laying in foundations and plinth cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) excluding the cost of centring and shuttering. |
| 399 | Providing and laying damp proof course 38mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 12.5 mm nominal size) |
| 400 | Extra for providing and mixing water proofing material in cement concrete work in the proportion recommended by manufacturers. |
| 401 | Applying a coat of hot bitumen (mashphalte 80/100 or equivalent) using 1.70 kg. per sqm. on damp proof course after cleaing the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 402 | Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth. |
| 403 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in: M20 (1 cement : 1.5 cparse samd : 3 stone aggregate 20mm nominal size) |
| 404 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1:3 (1 cement : 3 fine sand) of thickness not exceeding 6mm to give a smooth and even surface but excluding cost of centring, shuttering and reinforcement. a. M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20mm nominal size). |
| 405 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1:3 (1 cement :3 fine sand) of thickness not exceeding 6mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a. M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20mm nominal size). |
| 406 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size) |
| 407 | Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20mm nominal size) |
| 408 | Centring and shuttering including strutting, propping etc. and removal of form work for: Foundation, footings, bases of columns etc. and mass concrete. |
| 409 | Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5m height) |
| 410 | Lintels, beams, girders, bressumers and cantilevers etc. |
| 411 | Column, pillars, posts and struts etc. |
| 412 | Stairs (excluding-Landings)----Waist slabs |
| 413 | Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/ TMT steel |
| 414 | Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand). |
| 415 | Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level. |
| 416 | Half brick masonry (with best available local bricks) in cement mortar 1:4 (1cement: 4 coarse sand) in foundation and plinth. |
| 417 | Grading Roof for water proofing treatment with:Cement Mortar 1:3 (1 cement :3 coarse sand) |
| 418 | Providing gola 75 x 75 mm in cement concrete 1:2;4 ( 1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1 : 3 ( 1 cement : 3 fine sand) as per standard design : |
| 419 | Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown or/ and residual bitumen applied hot @ 1.45kg per sqm. of area for each courese, second course of roofing felt type-3 grade-1 (hessian base self finished bitumen felt) and fourth and final course of stone grit 6mm and down size or pea size gravel spread at 6 Cu.dm. per sqm. including preparation of surface excluding grading complete. |
| 420 | Providing and fixing on wall face C.I Rain water pipes including filling the joints with spun yarn soaked in neat cement slurry & cement mortar 1:2.100 mm diameter |
| 421 | Providing and fixing M.S. Holder bat clamps of approved design of C.I. or S.C.I. pipes embedded in and including cement concrete block 10mm x 10cm x 10cm of 1:2:4 mix (1 cement : 2 coarse sand: 4 stone aggregate 20mm nominal size) including cost of cutting holes and making good the wall etc. 100 mm diameter |
| 422 | Providing and fixing on wall face C.I. accessories for rain water pipes including filling the joints with spun yarn soaked in neat cement slurry and cement mortar 1:2 (1 cement : 2 fine sand) b)- CI Plain Bend-100mm dia |
| 423 | b)- CI Plain shoe-100mm dia |
| 424 | Making khurras 45 x 45 cm with avg. minimum thickness of 5 cm cement concrete 1 : 2 : 4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1 mm x 1 m x 400 micron, finished with 12 mm cement plaster 1 : 3 ( 1 cement : 3 coarse sand) and finishing the outlet complete as per drawing. |
| 425 | Providing and fixing flush door shutters, decorative type, core of black board construction with frame of 1st class hard wood and well matched 1st class teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. a) 40mm thick including anodized aluminum butt hinges with necessary screws. |
| 426 | Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size). |
| 427 | Providing and fixing aluminum handles anodised transparent or dyed to required color or shade with necessary screws etc complete. 125 mm |
| 428 | Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete.a) 300 x 10 mm |
| 429 | Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete.a) 300 x 16 mm |
| 430 | Providing and fixing 50 cm long aluminum kicking plate 100x3.15mm anodised, transparent or dyed to required color or shade with necessary screws etc. complete. |
| 431 | Providing and fixing chromium plated finished 100mm mortice latch and lock with 6 levers and a pair of CP handles with necessary screws etc. |
| 432 | Providing and fixing MS Round or Sq bars at required spacing in wooden frames of windows. |
| 433 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 60x60 cm refer carpet area calculation |
| 434 | SKIRTING/ DADO : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 12mm thick cement mortar 1:3 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x600 mm |
| 435 | Providing and fixing 1 st quality ceramic glazed wall tiles confirming to IS: 15622 ( thickness to be specified by manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any sizes as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 Cement : 3 Coarse sand) and joining with grey cement slurry @3.30kg per sqm including pointing with white cement mixed with pigment of matching shade complete. |
| 436 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x30 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. sqm 1225.10 shades, except White, Ivory, Grey, Fume Red Brown laid on 20mm thick bed of Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete. |
| 437 | Providing and laying gang saw cut 18 mm thick, mirror polished premoulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge.With granite stone of area less than 0.50 sqm |
| 438 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a approved steel priming coat using structural steel as required in gratings, frames, guard bars, railings, brackets, gates, grills etc. |
| 439 | Providing & fixing Hand Rail of approved size by welding etc to steel ladder railing, balcony railing, staircase railing & similar works, including applyingnpriming coat of approved steel primer : E.R.W Tube |
| 440 | Door /Window / Ventilator Frames:- Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2 mm). Both verticalssides of the frame reinforced with PVC profile of cross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm) and 75 mm x 200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut, jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturer's specification and direction of engineer- in-charge |
| 441 | 12 mm thk cement plaster 1: 4( 1 cement : 4 coarse sand) on walls. |
| 442 | 15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement :4 fine sand) |
| 443 | Applying one coat of cement primer of approved brand and manufacture on wall surface. |
| 444 | Finishing walls with water proofing cement paint of required shade : |
| 445 | Wall painting (two or coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade. |
| 446 | Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works. |
| 447 | With ready mixed pink primer of approved brand and manufacture on resinous wood and plywood works. |
| 448 | painting with synthetic enamel paint of approved brand and manufacture to give an even shade- 2 or more coats |
| 449 | Painting (two or more coats) on rain water, soil waste and vent pipes and fittings with aluminum paint of approved quality over a priming coat of ready mixed genuine red lead on new work. |
| 450 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) :Anodised Aluminium (anodised transparant or dyed to required shade according to IS:1868, minimum anodic coating of grade SC-15) |
| 451 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge. (Cost of aluminium snap beading shall be paid in basic item)With float glass panes of 5.5 mm thickness. |
| 452 | Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-incharge complete.255 X 19 mm. |
| 453 | ELECTRICAL WORKS |
| 454 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 455 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 456 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (For Light Ckt & Light plug) |
| 457 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair |
| 458 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 459 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm25 mm |
| 460 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet |
| 461 | TV antenna socket outlet |
| 462 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 463 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 464 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm) |
| 465 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 466 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 467 | Installation, Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 468 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 469 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep |
| 470 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 471 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. For Data & CCTV1 run of cable |
| 472 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC copper conductor single core cable etc. as required. insulated |
| 473 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.(For A.C Units) |
| 474 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 475 | CEILING FANS : Supplying, installation, testing & commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fans with Brushless Direct Current (BLDC) motor, class of insulation B, 3 nos blade, 30cm long down rod, 2 nos canopies, shakel kit, safety rope, copper winding, power factor not less then 0.9, supply earthing etc complete as required |
| 476 | Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCBs & incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required)8 way (4 + 24), Double door |
| 477 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single Pole |
| 478 | Triple pole and neutral |
| 479 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 480 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 481 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 482 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 483 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm |
| 484 | Supplying the following Lighting fixtures including lamps at site. Rate shall include all taxes and duties, transportation etc. complete. (4000 K) (Samples of all light fixtures to be submitted to the client for approval prior to procurement of fixtures)Supply, installation, testing & commissioning of Surface mounted Linear type 4ft 18W Led fitting delivering an initial lamp lumen of 2000 lumens & the luminaire shall be with system efficacy ≥ 100 lm / W. Housing: Polycarbonate . IP20 , Optics: Polycarbonate Diffuser. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 20% & PF ≥ 0.95. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard. Wipro Cat No.: LL20-2021-xxx-65 NE |
| 485 | Supply, installation, testing & commissioning of Surface mounted Linear type 2ft 10W Led fitting delivering an initial lamp lumen of 2000 lumens & the luminaire shall be with system efficacy ≥ 100 lm / W. Housing: Polycarbonate . IP20 , Optics: Polycarbonate Diffuser. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 20% & PF ≥ 0.95. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard. Wipro Cat No.: LL20-2021-xxx-65 NE |
| 486 | Supply of 10\\" dia 1 phase exhaust fan, 900 RPM |
| 487 | 48\\" dia (1200 sweep) double ball bearing ceiling fan Crompton/Usha/ Havels |
| 488 | PHILIPS, 15W, Polycarbonate, Edge Glow Surface LED Downlighter with 270 degree light spread, 1500 lumen, 6500k, 102mm Dia |
| 489 | PLUMBING WORKS |
| 490 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid,10 litre low level white vitreous china flushing cistern & C.P flush bend with fitting & C.I brackets,40mm flush bend,overflow arrangement with special of standard make and mosquito proof coupling of approved municipal design complete including painting of fitting and bracketss,cutting and making good the walls and floors wherever required.W.C pan with ISI marked white solid plastic seat and lid. |
| 491 | Providing and fixing white vitreous china wash basin with C.I./M.S. brackets, 15 mm CP brass pillar taps, 32 mm CP brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required :Flat back wash basin size 550x450 mm with a single 15 mm CP pillar tap |
| 492 | Providing and fixing Stainless steel A ISI 304(18/8) Kitchen sink as per IS:13983 with CI Brackets and stainless steel plugs 40mm, including painting of fittings and brackets, cutting & making good the walls where ever required.Kitchen sink with drainboard, 510 x 1040mm with bowl depth 250mm |
| 493 | Providing and fixing CP Brass Waste for wash basin and sinks.40mm dia |
| 494 | Providing and fixing MI fisher union for wash basin and sinks.40mm dia |
| 495 | Providing and fixing CP Brass or MI trap for wash basin and sinks.b) 40 mm dia |
| 496 | Providing and fixing rubber plug for sink or wash basin. |
| 497 | Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleats with CP brass screws and washers. |
| 498 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes.100 mm dia |
| 499 | Providing and fixing sand cast iron heel rest sanitary bend.100 mm |
| 500 | Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100 x100x100 mm |
| 501 | Providing and fixing sand cast iron trap of self cleaning design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors.a) 100 mm inlet and 100 mm outlet |
| 502 | Painting sand cast iron soil spun soil waste vent pipes and fittings with paint of any color such as chocolate, grey or buff etc over a coat of primer (of approved quality) for new work.100 mm diameter pipe |
| 503 | Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good the walls etc. (internal work)20 mm dia nominal bore |
| 504 | 25 mm dia nominal bore |
| 505 | Concealed pipe including painting with anti-corrosive bitumastic paint, cutting chases and making good the wall20 mm dia nominal bore |
| 506 | 25 mm dia nominal bore |
| 507 | Providing and fixing brass full way valve with wheel of approved quality.32 mm nominal bore |
| 508 | Providing and fixing brass stop cock of approved quality complete25 mm nominal bore |
| 509 | Providing and placing on terrace ( at all floor levels ) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 510 | Providing and fixing CP brass bib cock of approved quality conforming to IS : 893120 mm Nominal bore |
| 511 | Providing and fixing ball valve (brass) of approved quality.High or Low presssure with polythelene float : 20 mm Nominal bore |
| 512 | Providing and fixing CP Angle Valve for basin mixtures and geysers points EWC Cisterns of approved quality conforming to IS : 8931 |
| 513 | Providing laying and jointing glazed stone ware pipe grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.150mm diameter |
| 514 | Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15 cm thick as per standard design.250mm |
| 515 | Constructing brick masonry manhole with 2nd class bricks in cement mortar 1: 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design.a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg). |
| 516 | Providing and fixing square mouth SW gully trap class SP-1 complete with CI grating brick masonry chamber and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg. as per standard design.180x150mm size P typeWith common burnt clay FPS(non modular) bricks of class designation 7.5. |
| 517 | Sepitc Tank |
| 518 | Clearing and Grubbing Road Land . (Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness.)By Manual means:-a) In area of light jungle |
| 519 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30cm size, saturated soil and rock), lift upto 1.50m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returing the stacked soil in 15cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 520 | Dry stone pitching 22.50 cm thick including supply of stone and preparing surface complete (including carriage of stone for 5 Km lead). |
| 521 | Providing and laying cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in :a) Foundations and plinth |
| 522 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface with M20 (1:1.5:3 20 mm nominal size) |
| 523 | Centring and shuttering including strutting, propping etc and removal of form work for :d) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
| 524 | Reinforcement of RCC work including bending, binding and placing in position complete.a) Cold twisted bars. |
| 525 | Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand). |
| 526 | 12 mm cement plaster 1 : 3 (1 cement : 3 fine sand). In Plinth wall. |
| 527 | Providing laying and jointing glazed stone ware pipe grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.a) 150 mm dia SW pipes |
| 528 | Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15 cm thick as per standard design. a) 150 mm dia SW pipes |
| 529 | Construction of soak pit 1.5 x 1.2 x 1.5 m filled with brick bats including SW drain pipe 100 mm dia and 1.20 m long complete as per standard design. |
| 530 | Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work).b) 20 mm nominal bore |
| 531 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work).a) 32 mm niminal bore |
| 532 | b) 20 mm nominal bore |
| 533 | c) 25 mm nominal bore |
| 534 | Providing and fixing PVC trap of approved quality.a) 50 mm |
| 535 | Providing and fixing Chlorinated Polyvinyl Chloride(CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain and brass threaded fittings this includes jointing of pipes & fittings with one step CPVC solvent cement trenching, refilling & testing of joints complete as per direction of Engineer Incharge.a) External worki) 50 mm dia |
| 536 | ii) 75 mm dia |
| 537 | Providing & fixing steel nahani trap floor drain for WC |
| 538 | Providing & fixing PVC elbow for PVC pipe fitting. |
| 539 | Providing and fixing sand cast iron soil, waste and vent pipe.b) 75 mm dia Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail