| 1 | Supplying of Swaged Steel Tubular pole (IS 2713, Pt. II 1980) for following designation and of following dimensions 410-SP-33; 9.0mtrs: 164 Kg. |
| 2 | S/F arm bracket of 50 mm bore tubular Pipe (M.S.) of 1. 5 m (5’) length for fixing on 75/100 mm pole top including S/F 4 mm thick M.S. plate welded with bolts, nuts & clamps,etc. as required with fabrication work |
| 3 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm |
| 4 | Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) (B) Do - by fine sand in Foundation |
| 5 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety |
| 6 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel |
| 7 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (f) 25 mm to 30 mm shuttering without staging in foundation |
| 8 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation |
| 9 | Supply & laying of 50 mm dia, GI pipe (ISI Medium) for protection of cable, road/drain crossing etc. |
| 10 | Finishing of PVC cable end with crimping method including supply & fixing of solderless socket, anti corrosive paste & jointing materials. |
| 11 | Earthling with 80 mm dia G.I. pipe ( TATA medium) X 3.0 mtrs long and 1X 19/8 stranded G.I. hot dip wire 4.0 mtrs long, 25 mm dia X 150 mm long galvanized bolts, double nuts, double washers including socketing at both ends of stranded G.I. hot dip wire by crimping sockets/ thimbles and supplying , fixing 40 mm dia G.I. pipe (ISI medium) protection 3.00 mtr long to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 mtrs for morrum soil. |
| 12 | Supplying & Erection of mini size feeder pillar box of Size (918 x 561 x 382 mm) made up of 2 mm thick MS Plate alongwith suitable M.S. Angle. The P.B. have double hinge door at the front & back with suitable locking arrangement. The box will be painted by 2 cores of aluminiam paint over 1 coat of red oxide paint. Suitable arrangement should be provided for fixing of Timer unit, fuse unit & other accessories. Leg of the pillar box will be 900 mm in length by made up of (35 x 35 x 3 mm MS Angle with suitable base Plate. Legs of the Pillar box will be erected at 300 mm below the ground level with cement concrete (6:3:1). Rest portion coverd by 5\\" Brick Wall with plastering & net cement & bottom portion filled with silver sand as drawing & direction of E.I.C |
| 13 | Supply & delivery of 200 watt LED flood light light with pressure dia cast aluminium housing, IP66 protection, road way luminaries with high power LED as per the detail technical proposal specification and vendor list attached with 7 year warranty. |
| 14 | Supply of PVC / SWA / PVC armoured cable of 1.1 KV grade to the work site of size 10 mm2 x 2 core of make Havells / Crystal / Gloster/ Polycab/Mescab. (Page K-10) |
| 15 | Laying of above cable through PVC pipes for underground work of approved make of of schedule 80 mm duty conforming to ASTMD -1785 and threaded to match with GI pipe as per IS : 1239 (part -I) with all necessary accessories, special viz bend, tee, union, cross elbo, nipple, lonhscrew, reducing scoket, reducing tee, short piece etc. fitted including cost of all materials jointing materials, cutting pipes, making threades, cutting trenches upto 1.5 metre below surface in all shorts of soil and refilling the same as directed complete in all respect. (payment will be made on the centre line measurement of the total pipe line including all specials no separate payment will be made for accessories, specials) |
| 16 | Construction of Plaque (Flok) approved by departmental drawing. |
| 17 | Add GST 18% |
| 18 | Add Cess 1% Please Enable Macros to View BoQ information |