| 1 | Geophysical survey charges Drilling of Borewell in Alluvial soil starta of clay and sand stone, shale, pebbles, boulders etc., by first taking and pilot bore of 140mm/150mm/200mm dia and then enlarging to required dia by direct or reverse rotary mud circulation method, using contractor's ridg fuel labour drilling at the site shown by the Department Officers including construction of mud pit and transportation (Water available within a lead of 1.5K.M) using Rotary Rig. |
| 2 | Upto 60m.Depth ending below Ground Level |
| 3 | From 60m and upto 90m depth ending from G.L. |
| 4 | From 90m and upto 120m depth ending from G.L. |
| 5 | From 120m and upto 150m depth ending from G.L. |
| 6 | From 150m and upto 180m depth ending from G.L. |
| 7 | Reaming 140/150mm Diameter Bore to 300 mm Diameter Below Ground Level From 0Mts and Upto 60m.Depth ending below Ground Level |
| 8 | From 60m and upto 90m depth ending from G.L. |
| 9 | From 90m and upto 120m depth ending from G.L. |
| 10 | From 120m and upto 150m depth ending from G.L. |
| 11 | From 150m and upto 180m depth ending from G.L. |
| 12 | Reaming 300mm Diameter Bore to 400 mm Diameter Below Ground Level From 0Mts and Upto 60m.Depth ending below Ground Level |
| 13 | From 60m and upto 90m depth ending from G.L. |
| 14 | From 90m and upto 120m depth ending from G.L. |
| 15 | From 120m and upto 150m depth ending from G.L. |
| 16 | From 150m and upto 180m depth ending from G.L. |
| 17 | Electrical Logging Charges for borewell |
| 18 | Supply and delivery of the following materials required for the erection of borewell 200 mm dia OD PVC plain casing pipe CS PIPE |
| 19 | 201 mm dia OD pvc Plain casing pipes CM PIPE |
| 20 | 201 mm dia OD PVC plain casing pipe CM PIPE |
| 21 | 200 mm dia OD pvc ribbed screen casing pipes |
| 22 | 200mm dia Bottom Dummy (Pre end cap) |
| 23 | Bore Well Top Cover |
| 24 | Labour charges for inserting PVC Casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes, supplying and packing the annular space with pebbles of size and quality as approved by the Department Officer. 200mm OD PVC Pipe |
| 25 | Charges for developing the borewells with air compressor of 600 CFM capacity (minimum 8 hours) including transportation labour and fuel charges for compressor as direct by Departmental Officers conducting yield test \\"V\\" Notach method |
| 26 | Supply and delivery of submersible pump set 100LMP X 175M Head |
| 27 | 20A-35A Star delta starter panel Board |
| 28 | 4 sq.mm 3 core submersible cable |
| 29 | 63mm OD HDPE HOSE - 10Ksc |
| 30 | 50mm dia SS Nipple |
| 31 | 50mm dia Elbow |
| 32 | 50mm dia MS Clamp sets |
| 33 | 50mm dia GI Flange |
| 34 | 100Ams fuse unit |
| 35 | Earthing set with GI Pipe, GI wire , Bolt and net |
| 36 | Labour charges for errection of submersible pump set including cable jointing fixing of starter, fuse unit and all other accessories etc., complete. Above 5 to 10HP |
| 37 | Earthwork Excavation and Depositing on bank with an initial lead and lift in all types of soil for pipe line works |
| 38 | Supplying and delivery of following Pipes and specials including transporting charges etc. 63mm OD PVC Pipes |
| 39 | 63mm OD PVC bend |
| 40 | 63mm OD PVC Tee |
| 41 | Laying and jointing the following PVC Pipes to trench with proper allignment with PVC Coupler & Cement Paste including conveying & testing with required preasure and leakage etc. |
| 42 | Refilling the Trench with excavated earth after pipes are laid |
| 43 | Earthwork excavation in all classes of soils and depositing on bank with an initial lead and lift such as sand or other loose soil, wet sand not under water silt and ordinary soil, sandy loom, and hard stiff, black cotton soil, red earth, earth mixed with |
| 44 | Filling with good river sand into foundation and basement including cost and conveyance of all materials to work site and all labourcharges for filling, watering etc., complete. |
| 45 | CC 1:4:8 mix using 40mm ISSHBG metal including cost and conveyance of all materials to work site and all labour charges for mixing, laying and watering etc., complete. |
| 46 | Reinforced Cement concrete 1:1.5:3 mix using 20mm ISSHBG metal from approved sources including cost and conveyance of all materials to work site and all labour charges for mixing, laying, and watering etc., complete. Above basement |
| 47 | Brickwork in CM 1:5 mix using country bricks of standard size including cost and conveyance of all materials to work site and including all labour charges and all incidential charges etc., complete. Upto basement |
| 48 | Brickwork in CM 1:5 mix using country bricks of standard size including cost and conveyance of all materials to work site and including all labour charges and all incidential charges etc., complete. For Superstruture. |
| 49 | Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The Surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the Departmental Officers. [The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (waterproof abrasive sheet), cost of putty blade, labour charges for grinding the joints and sand papering, two coat of putty, scrapping the putty area to level the surface smooth, etc., complete]. The Putty should be got approved by the Executive Engineer before use on work. (Based on SoR 2023-24) |
| 50 | Plastering in CM 1:5 ,12mm thick including cost and conveyance of all materials to work site and all labour charges etc., complete. |
| 51 | Flooring with Granolithic flooring to 25mm thick using CC 1:2:4 mix using 20mm ISSHBG metal including cost and conveyance of all materials to work site and all labour charges etc., complete. |
| 52 | Painting the newly plastered wall surface with two coats of Plastic Emulsion Paint outside the building over one coat of cement primer including clearing the surface in all floors etc., complete as per standard specification. |
| 53 | Painting two coats with ready mix paint of approved colour and trade for doors & windows including cost and conveyance of all materials and all other labour charges etc., complete. |
| 54 | Supplying and erriecting, centring for plane surfaces structures such as RCC slab, beam etc., inlcuding strutting upto 3m height using mild steel sheets of size 90cm x 60cm x and B.G 10 stiffened with M.s angles of size 25 mm x 25mm x 3mm for boarding lai |
| 55 | Supplying and erriecting, centring for plane surfaces structures such as RCC slab, beam etc., inlcuding strutting upto 3m height using mild steel sheets of size 90cm x 60cm x and B.G 10 stiffened with M.s angles of size 25 mm x 25mm x 3mm for boarding lai |
| 56 | Supply and fabrication of steel including cost and conveyance of steels to worksite including labour for cutting, jointing and welding if necessary including all labour charges for dying with binding wire etc., complete. |
| 57 | Supplying Steel Door and windows as per standard specification etc |
| 58 | Wiring with 2 x 1.50 sqm ( 22/0.3 ) PVC insulated unsheathed single core Copper Conductor of 1100 v Grade in suitable PVC Rigid Pipe on wall and ceiling with PVC accessaries with TW Switch box with 5 A F . T . Switch with painting of suitable colour for Light Point and Fan Point ( For Electronic Regulator ) S D N o 18 |
| 59 | Supply and fixing of 15w CFL Lamp (spiral lamp) for existing holder on wall etc complete. |
| 60 | Supply and fixing of 16amps DP Switch with metal clod of 500v with tube connection 32Amps and netural on suitable T.W Plug plante with supplying on reeper on Either side With PWD Earthen etc. |
| 61 | Supply and run of 2 of 6s.qm 84/100 pvc SC Unstrenthed on condition of 1100v grade in 25mm side GI Pipe lend with both ends with necssary angles etc |
| 62 | Supply and run of 2 of 6s.qm 84/103 pvc SC Unstrenthed on condition of 1100v on 7/70 GI Reducer with fuse service connection etc |
| 63 | Towards cost and supply of RCC Jolly of size 0.45*0.45m |
| 64 | Provide LFW 1% Please Enable Macros to View BoQ information |