| 1 | PART-A (Bldg.) |
| 2 | Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler with hermetically sealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick) and tank (0.5 mm thick) , stainless steel water tray,minimum two nos Brass Chrome plated faucets and suitable drainage system complete in all respect with required height MS fabricated and Painted Angle iron frame ( Cost of frame to be paid Extra )complete in all respect of the following capacity. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . cooling capacity 40 Ltr./Hr. and storage capacity 80 Ltrs (22.51.3) |
| 3 | 9.2/B-9Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: |
| 4 | 2.7.3 /S-2P & F Bib cock (IS: 8931 Mark), Superior quality of approved make:(A) C.P. brass bib cock 15mm nominal bore. |
| 5 | 2.11.2/S-2P & F Ball Cock (IS: 1703 Mark) with Rod & P.V.C. Ball complete: Brass wt. not less than 400gm 20mm |
| 6 | 2.15.1 /S-2P & F Full - way Valve (IS: 778 Mark) or wheel valve of approved make:(A) Gun metal 15 mm nominal bore |
| 7 | (B) Gun metal 25 mm nominal bore (2.15.3) |
| 8 | 2.26.3/S-2P & F PVC Storage Tank ( IS: 12701 marked indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 CM long wash out pipe with plug & socket, including making connection etc., complete of approvrd design: 500 ltr capacity |
| 9 | 2.38.1&2.38.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)(A) 25mm nominal outer dia pipes |
| 10 | E 1.3.1Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSRon board. |
| 11 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR(A) 2 x 2.5 sq. mm. + 1x1.5sqmm (4.1.7) |
| 12 | 7.36Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works with Galvanized box of 1.2 mm thick with earth terminal with suitable size phenolic laminated sheet (IS : 2036 - 1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outlet making connection , testing , etc. as required. . For specification of Wiring accessories refer Chapter E - 07 related item & For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 13 | PART- B (Item Rate Basis) |
| 14 | SITC of RO water system with Filteration stage = Particulate filter-Membrane life enhance filter-sedimentation filter-Pre carbon filter-RO Membrane filter-Postcarbon filter, Input power Rating - 230 V AC, 50H= Hz, Percentage of Rejection TDS - 90% orbetter having following features (a) Double purification by Ro with ESS or latest technology with TDS indicator. (b) Spin welded RO Membrane Housing to prevent tempering. (C) Push fit components for leak proof performance (d) Fully automatic operation with auto start and auto off. (E) SS/ABS construction for corrosion free lifespan. (F) Equally suitable for water from all bore wells, overhead storage tanks, water tankers and even municial taps. (G) RO Membrane Flushing - Auto Flush @ Every start, Every stop and every one Hour of working for one minute, complete in all respect with following capacityPurification capacity-50 LPH, duty Cycle 270-500 Liters/day Please Enable Macros to View BoQ information |