| 1 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erectionof Double Walled Corrugated (DWC) HDPE pipe to be laid1mtr. below ground level including excavation placingthe pipe in position and back filling with excavated soil etc.of the required size: Double WalledCorrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.) |
| 2 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE):Supply, laying and erection of aluminium conductor XLPEinsulated PVC sheathed Un-armoured and servedcable 1100 volts grade as per IS 7098 (Part-1)1988 to belaid loose in the existing trench or pipe as per PWDGeneral Specifications: Overal size 16 sqmm (4Core) Un-armoured (Loose) |
| 3 | GALVANIZED STEEL OCTAGONAL POLES FOR WIND VELOCITY OF 169 Km/ HOUR:Supply and erection of Galvanized Steel Octagonal Pole (Sheet thickness 3mm) designed to withstand wind speed 169km/ hour of suitable length(Raw confiming to material IS-5986 (FE-510), BSEN-10025S-355Jor ASTM-572A (GR-50)) and thickness of galvanization (70mm thick) conforming toIS:2629/ IS:2633/ IS:4759, BSEN-ISO-1461-1991 OR ASTM-A123/A123M-02. Thepole shall be in single piece hot dip galvanized and shallbe tapered towards the top. The bottom section shall have openable slot with exteriorsurface door & shall have suitable locking arrangementfor housing three phase 4wire cable connection, bakelitesheet, MCB, loop in and out arrangement for incoming/outgoing cables. There shall be suitable arrangement forearthing. Rigid Base plate of suitable size and thicknessshall be welded inside and outside at the bottom of polewith provision for fixing 4 foundation bolts. The octagonal pole shall be bolted on a pre- cast foundation with a set of four foundation bolts forgreater rigidity. The foundation shall be erectedover cement concrete M20 with steel of given size as perdesign of original pole manufacturer to fixed up to arequired planting depth below ground level as required: Galvanized OctagonalPole Overall Length 7 metre (Sheet thickness 3mm), Topdia.(A/F) 70mm and bottom dia. (A/F) 130mm, Foundationsize below G/L 550mm x 550mm x 1400mm, 4Nos.Foundation Bolts size 20mm dia., Length=700mm with Base PlateDimensions 240mm x 240mm x 16mm Thick |
| 4 | SINGLE/ DOUBLE ARM BRACKETS:Supply and erection of bracket for galvanized octagonal pole,the bracket should be fixed on the top of the pole having topouter dia. 70mm to 90mm (A/F) complete in all respectas approved by the Engineer-in-charge at site:((c)) Single arm bracket 1.5 metre long for galvanizedoctagonal pole |
| 5 | PVC INSULATED FR COPPER CONDUCTORCABLES:Supply and erection of PVC insulated FR single coreUnsheathed copper conductor cable (ISI marked) suitableupto 1100 volts grade confirm to IS:694/1990 left bare inpipe or casing of suitable size complete in all respect asdesired by Engineer-in-charge: Overall size 1.5sq.mm (Un-sheathed) |
| 6 | R: ((i) ) S/E of Microprocessor BasedStreet Light Controller with digital time switch daily programmed with stand bylithium battery with back up of 6 years with min. time between 2 switching operations is 1 minute, three pole power contactors 40A. with coil voltage 220-230V AC with 1 no. aux. contact NO, MCB 2 pole 40amp. (C-Curve, 10kA) & power wiring withsingle core PVC insulated FR cable 10 sq. mm and controlwiring with PVC insulated FR cable 1 sq. mm, 1 no. two position selector switch to bypass timer and other accessories & petty material (din rail, 4 pole bakeliteterminal strip 63A/ 440V AC, required nut bolts) should be fixed on bakelite sheet 6mm thick to be mounted in a IP54 surface/ flush mounting powder coated sheet metal(1.60mm thick) cabinet having size 450mm x 600mm x 150mm to switch ‘ON’ all the 3 phases & switch ‘OFF’ 3 phases pre-fixed timingsphases pre-fixed timings complete in all respect as per satisfaction of Engineer-in-charge: Street Light Controller (For Three Single Phase Circuits) with 3 Nos. Three Pole Power Contactors 40A, 1 no. aux.contactor 6 amp. (2NO+2NC) with coil voltage 220V AC, 3 Nos. MCB 2 Pole 40amp. (C-Curve,10kA) & petty material (Din rail, 2 Nos. 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) |
| 7 | GALVANIZED IRON PIPES AND G.I. EARTHINGSupply & erection of G.I. pipe (A-Class) as per IS:1239(Part-I) 2004 including sockets, bends, inspectionboxes, Steel hooks, GI saddle clamps and other pettymaterials etc., where necessary including paintingas per PWD General Specifications:Earthing earth rod 20 mm dia for providing earthconnections upto line earthwith G.I. Wire 8 S.W.G. (4mmdia.). The rod shall be tapered at one end and flatted onother end. The hole size 10mm dia shall be drilled onthe flatened side for facilitating connection withG.I. wire and thimble etc. Therod shall be erected in groundupto completevertically GI Earth rod 20 mm dia.,3 mtr. Long |
| 8 | Supply and Erection of LED Street Light 70 watt (includingLED driver) with pressure die cast aluminium housing withcontrol gear ( with IP 65/ IP 66 protection), CRI Minimum70, CCT >5700K, toughened glass fitting, LED fixtureminimum 120 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection (as per BIS standards) , surge protection 10kv and above (as per (IS/IEC standards) wattage of each LED Highpower LED of 1 watt to 5 watt with mandatory modular lenses, input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in allrespects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no 1410-1422 06/05/2021. AT-2021/GL Dated Dated 06/05/2021. Besides this thelighting fixture manufactures should have in house NABLaccredited labortary. Make Havells ENDURASUNDOWNSL70WLED 757PASYBOPC / CromptonLSTS-70-CDL-M / SURYA SLE UL 70W IP66 NGN / BajajENXTP 84L WH CR PC SD |
| 9 | Dismentling of CC poles with carrige till dump site |
| 10 | Dismantling Pavements (By of FlexibleMechanical Means)-Dismantling of flexiblepavements thickness above 50mm by mechanical meansand disposal of dismantled materials up to a lead of 1000meters, stacking serviceable and unserviceable materialsseparately as per technical clause 202 of MORT&Hspecifications |
| 11 | Cement Concrete 1:2:4 with stone ballast or shingle mixing by manual means |
| 12 | Earth,Surkhi, Sand, Earth, Fly Ash, Bajri, Ballast,Stone boulders, Kankar and building rubbish, Earth. 5 km Please Enable Macros to View BoQ information |