| 1 | Appendix A - Providing Submain works |
| 2 | OD39236/2025-2026:1.DESIGN, SUPPLY, INSTALLATION, TESTING, AND COMMISSIONING OFSUB-MAIN MICRO-IRRIGATION SYSTEM AS PER THE IS SPECIFICATIONSAND DESIGN TO BE GOT FINALLY APPROVED FROM KIIDC INCLUDING ALLSUBMAIN PVC PIPELINES,PLACING EMITTER TAKE-OFF ANDFITTINGS, ACCESSORIES, FLUSH VALVES(UV PROTECTED), IRRIGATIONCONTROL VALVES(UV PROTECTED), AND FITTINGS ANDACCESSORIES,PRESSURE TESTING OF SUBMAIN PIPE LINES AND JOINTSAS PER THE GUIDLINES OF KIIFB/KWA, LABOUR CHARGES, COST OFFITTINGS, CONVEYANCE INCLUDING ALL COST OF TRENCHING,BACKFILLING, AND LAYING AS PER DESIGN ALIGNMENT AND LEVELS,IF ANY, ETC, INCLUDING MATERIAL TEST REPORT FROM THE THIRDPARTY MATERIAL QUALITY CONTROL UNIT, AS PER THESPECIFICATIONS AND DIRECTIONS OF DEPARTMENTAL OFFICERS ATSITE. |
| 3 | Appendix B - Providing Main Line works |
| 4 | OD39213/2025-2026:2.DESIGN, SUPPLY, AND INSTALLATION, TESTING AND COMMISIONINGOF MAINLINE MICRO-IRRIGATION SYSTEM AS PER THE ISSPECIFICATIONS AND DESIGN TO BE GOT FINALLY APPROVED FROM KIIDC INCLUDING ALL MAINLINE PVC PIPES,FERTIGATION UNIT(UV PROTECTED), IRRIGATIONCONTROL VALVES FOR MAINLINE,PRESSURE TESTING OF MAIN PIPELINES AND JOINTS AS PER THE GUIDLINES OF KIIFB/KWA, FITTINGS ANDACCESSORIES,PRESSURE TESTING OF LAID PIPE LINES ETC WITH ALLCOSTS OF MATERIALS, LABOUR CHARGES, COST OF FITTINGS,CONVEYANCE INCLUDING ALL COSTS OF TRENCHING, BACKFILLING,AND LAYING AS PER DESIGN ALIGNMENT AND LEVELS IF ANY, ETCINCLUDING, MATERIAL TEST REPORT FROM THE THIRD PARTYCONTROL UNIT,(COST FOR ROAD CUTTING & UTILITY SHIFTING ISEXCLUDED) AS PER THE SPECIFICATIONS AND DIRECTIONS OFDEPARTMENTAL OFFICERS AT THE SITE. |
| 5 | Appendix C - Providing Automation Works |
| 6 | OD39237/2025-2026:SURVEY, DESIGN, INSTALLATION AND TESTING OF FULLY AUTOMATEDCOMMUNITY MICRO IRRIGATION SYSTEM WITH ELECTRONICALLYCONTROLLED VALVES IN THE PROJECT AREA INCLUDING CONDUCTINGCONTOUR SURVEY, INDIVIDUAL FARM BOUNDARY SURVEY,PREPARATION OF DESIGN AND DRAWINGS, PREPARATION OFOPERATION MANUAL,SUBMISSION OF MATERIAL APPROVALREQUEST(THE CONTRACTOR HAS TO SUBMIT THE MATERIAL APPROVALREQUEST BEFORE STARTING THE WORK), SUBMISSION OF WORKSCHEDULE, FORMATION OF WATER USERS ASSOCIATION, TRAINING TOTHE FARMERS ON MODERN FARMING TECHNICS, WATERCONSERVATION, VALUE ADDITION,LIVESTOCK DEVELOPMENT ANDDOCUMENTING ALL TRAININGS , SUITABLE PUMP OF ADEQUATEDESIGN CAPACITY WITH STANDBY AND ACCESSORIES FOR SUCTIONAND DISCHARGE,COMMISSIONING OF HEAD UNIT INCLUDING COST OFRELATED ALL ACCESSORIES SUCH AS PRIMARY FILTRATION,SECONDARY FILTRATION,(SUITABLE AVAILABLE WATER SOURCESSUCH AS PONDS RENOVATED AND WATER FEDDED IN MRBC PHASE-2CIVIL WORKS & RIVERS CAN BE UTILIZED, THE FILTERS SHALL BESUITABLE FOR GROUNDWATER OR SURFACE WATER ACCORDING TOTHE SITE CONDITION), FEEDERMAIN FROM FILTERS, SOLENOID VALVES,PRESSURE RELEASE VALVES, PRESSURE GAUGES, SAFETYACCESSORIES, DRIP SYSTEM WITH PC EMITTERS OF MAXIMUM 3LPH DISCHARGE HAVING EMITTER TO EMITTER SPACING, SELF-FLUSHING AND CONTINUOUS SELF-CLEANINGMECHANISM, IDEAL FOR PERMANENT CROPS IN COMPLEXTOPOGRAPHY AND SUB SURFACE APPLICATIONS, RESISTANT TOSTANDARD NUTRIENTS USED IN AGRICULTURE, DRIP MANIFOLDACCESSORIES,QUICK RELIEF VALVE,NRV, MCU SYSTEM WITH ALLOTHER ACCESSORIES(MCU SHOULD BE SCADA SCREEN WITH REAL TIMESTATUS OF OUTPUTS AND SENSORS READING, COLOR DISPLAY, TOUCHSCREEN WITH RESOLUTION - 1280 * 800, CAPABLE OF WIRELESSOPERATION, INBUILT GLOBAL SIM, OPTION OF INTERNET CONNECTIONVIA LOCAL SIM & LAN, MULTIPLE USERS ACCESS WITH HIERARCHYBASED ON DIFFERENT ROLES, DOWNLOADABLE USER REPORTS -IRRIGATION -FERTIGATION REPORTS WITH CUSTOM TIME PERIOD,CREATE AND VIEW IRRIGATION BLOCKS , MULTI MAINLINE OPERATION(UP TO 4 MAINLINES), REMOTE ACCESS THROUGH WEBVIEW ANDMOBILE APP WITH PASSWORD PROTECTION, MONITOR IN-FIELD IRRIGATION STATUS BY SOILMOISTURE SENSORS WITH GRAPHICAL ANALYSIS , CAN BEOPERATABLE FROM ANYWHERE WITH MULTI LOGIN ACCESS), WATERMETER CONNECTABLE TO MCU,RTU UNIT WITH SOLAR PANEL AND ALLOTHER ACCESSORIES , SOIL MOISTURE SENSORS, SOIL TESTING AT THEFREQUENCY AS REQUIRED, AND THE CONTRACTOR HAS TO ESTABLISHPROVISIONS FOR UTILIZING THEIR AVAILABLE IRRIGATION SYSTEMS ON INDIVIDUAL FARMER FIELDS BY LINKING WITH THIS PROJECTWHERE THE FARMERS ARE WILLING,CONTRACTORHAS TO DEPLOY EXPERIENCED AGRICULTURAL ENGINEER, MACHINERYAND EQUIPMENT FOR EXECUTION, QUALITY CONTROLARRANGEMENTS, PREPARATION&SUBMISSION OF PRODUCTIONPLAN, CADASTRAL MAP, LAND USE MAP, GEOMORPHOLOGY MAP &OBTAINING CONSENT FROM FARMERS FOR LAYING PIPES AND ALLIEDWORKS IN THEIR PROPERTY WITH THE ASSISTANCE OF KIIDC STAFF,MARKET STUDY, FORMING FARMERS ASSOCIATION AND ADVISINGFARMERS ON CROP SELECTION BASED ON WATER AVAILABILITY,MARKET STUDY,AND ALL MATERIALS, FITTINGS, ADHESIVES SHALL BEAS PER THE SPECIFICATIONS AND STANDARDS OF BIS/INTERNATIONALCODES, INCLUDING OPERATION AND MAINTENANCE FOR THREE YEARSAS MENTIONED IN THE TENDER DOCUMENTS(THE CONTRACTOR HAS TODEPLOY EXPERIENCED TECHNISION FOR THREE YEARS MAINTANANCEFROM THE DATE OF PROJECT COMMISSIONING).PREPARATION OF ALLDOCUMENTS FOR ELECTRICITY CONNECTION. |
| 7 | APPENDIX 6ELECTRICAL |
| 8 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 9 | 90.12.7.36:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 300 sq mm |
| 10 | 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 11 | 1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 12 | 1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 13 | 90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 14 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 15 | 2.10.5:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole and neutral |
| 16 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 17 | 9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 18 | 5.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 19 | 5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 20 | 5.19:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 21 | 1.12:Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 22 | 90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp |
| 23 | 90.16.5.6:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.6. mm ( 4 SWG) |
| 24 | 90.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture |
| 25 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 26 | 9.1.30:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm) |
| 27 | OD39231/2025-2026:KSEB CONNECTION CHARGES |
| 28 | OD39233/2025-2026:4.1.6 - Supplying and installing following size of perforated pre-painted M.S. cable trays withperforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting s u s p e n d e r s e t c a s required.450 mm width X50 mm depth X 2.0 mm thickness |
| 29 | OD39223/2025-2026:METERING PANEL :Supply, installation,testing and commissioning of 11KV meteing panel Constructed out of 14SWG CRCA Sheet outdoor cubical type compactable for providing 11kv meter,TTB, 20Amps fuse (4nos) with 2A fuse link 2nos complete for 11kv metering should be placed over cement concrete based and channel platform |
| 30 | OD39229/2025-2026:OD20413/2023-2024 -Design, fabrication, supply, erection, testing and commissioning of following Cubicle type, fully compartmentalized LT Switchboards dust tight and vermin proof, Freestanding, floor mounting Switch board fabricated out of 16SWGCRCA sheet with Top Cable entry facility for both incomer and outgoing side fabricated out of 16 SWG CRCA sheet, chemically treated and painted with 2 coats of primer and two coats of stoving enamel paint of approved shade (Powder coated). The enamel paint of approved shade. The Switchboards should have a Set of suitably rated TP? Aluminium busbars with the specified current and fault level, Insulated with heat shrinkable, color coded PVC Sleeves and supported using DMC/SMC Pillar or Finger type busbar supports. APFC PANEL [Capacitors Panel]- 10.0 INCOME 160Amp TPN Isolator-1 No. INSTRUMENTS FOR INCOMER LED Type Red Yellow Blue(RYB), Indication Lamp swith Control fuses and toggle switches - 1set 3Phase 96sqmm Digital Ammeter 0-500A along with with 3nos Cast Resin Class1 400/5 metering Cts with 3nos2A Control fuses 1set. RELAYS Microprocessor based Automatic power factor control relaywith4steps having inbuilt facility for PF adjustment switching time adjustment ete. workingon415VAC,SACTsecondary current with RS485 Modbus output- Ino PF COMPENSATING CAPACITORS Gas Filled Capacitors Panel Mounting type, Discharge Resistors, Providing the Rated KVAR at 415 Volts Rated for upto 440V Continuous Operation OUTGOINGS:- 15KVAR Capacitor and 40Amps 3PoleMCB and Capacitor Duty 3Pole Contactor-3sets 10KVAR Capacitor and 32Amps 3PoleMCB and Capacitor Duty 3Pole Contactor - 2set SKVAR Capacitor and 16Amps 3PoleMCB and Capacitor Duty 3Pole Contactor - 3sets Design, Supply & Fabrication/Installation/Erection APFC |
| 31 | OD39220/2025-2026:M S B ( Main Switch Board ):Supply,installation,test ing and commissiong of MSB panel fabricated out of 14SWG CRCA sheet ,powder coated dust and vermin tight proof,front opening type, cable top/ bottom entry type,flush , floor mounted and also including base frame (incomer:630A 4pole MCCB-1 nos, outgoing:160A 4pole MCCB-8nos ,and also include suitable aluminium bus bar dimension) |
| 32 | OD39221/2025-2026:Earthing with G.I. earth plate 1200 mm X 1200 mm X 6mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 33 | OD39215/2025-2026:Supply , installing and commisioning of outdoor 11KV 400KVA transformer With DP structure also including primary side control protection(AB Switch, Lighting arrester,DO Fuse) combined CT,PT as per standards for HT measuring (CT-0.2S, 15VA turns ratio as required )(PT 11KV/110V 25VA ) metering cubicle and wiring to HT meter using 4sqmm 12 core copper cable as required .Terminations are made with 6mm dia long barrel copper lugs. The work include supply of flexible hose or other required material |
| 34 | OD39217/2025-2026:Supply, conveyane, installation, testing and commissioning of submersible pump set60HP ,Stage:4 outlet:150mm, Head range :36-93mtr, Discharge: 4400-2000lpm@70mtr 2400lpm |
| 35 | OD39227/2025-2026:Providing and fixing 65mm 'B'class GI pipe with GI fittings and clamps as required. |
| 36 | OD39226/2025-2026:Providing and fixing 80mm 'B'class GI pipe with GI fittings and clamps asrequired. |
| 37 | OD39235/2025-2026:Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using 2mm. CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be od183595/2020_2021 : used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly, comprising with the followings as per the KEI standard. Switch gears ? ABB, L&T/Equivalent. Incomer: 160-400A range, 4P, 36KA, microprocessor based MCCB with inbuilt earth fault relay, Bus bar: 200A TPN bus bar.phase indication lamps controlled with slide lock fuse-1set, multifuction meters with CTs-1no. Bus bar: 200A TPN bus bar. Outgoings:200A, 4P TPN SDF with HRC fuse - 3nos. with 3base 2key castle key interlock, 32A TPN SDF with HRC fuse-1no., 2nos. fully automatic VFD starter for suitable capacity motors, 3nos. 12.5Kvar power capacitors. Accessories: phase indication lamps controlled with SPMCBs-3sets, multifuction meters with CTs-3nos. |
| 38 | OD39228/2025-2026:100 A, 415 V, 2 way neutral link mounted on DMC/ SMC base. |
| 39 | OD39224/2025-2026:250A HRC fuse fuse base with fuse link<br> |
| 40 | OD39230/2025-2026:Supply of HRC fuse link 40- 60A |
| 41 | OD39214/2025-2026:Supply and fixing 63A HRC fuse base with fuse link in the existing meter board. |
| 42 | OD39219/2025-2026:Supply & installation of dust and vermin proof, 3 Phase Syntex Meter Board GS- od183263/202 MB-6535(size 760x450x260x) and to fix KSEB meters, fuse units, CT etc required including fixing it on wall, making good the damages colour washing etc. as required. |
| 43 | 90.12.7.33:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 150 sq mm |
| 44 | 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size |
| 45 | 90.12.1.19:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 70 sq mm |
| 46 | 9.1.26:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm) |
| 47 | 9.1.12:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 70 sq. mm (35mm) |
| 48 | 1.55.3:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 49 | OD41652/2025-2026:supply and fixing BCE type fire extinguisher 5kg |
| 50 | OD41659/2025-2026:supply of first Aid kit and 11kv Gloves |
| 51 | OD41660/2025-2026:supply and fixing HT, LT Electrical danger board |
| 52 | 1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 53 | OD41682/2025-2026:Supply, conveyane, installation, testing and commissioning of submersible pump set30HP ,Stage:4 outlet:100mm, Head range :40-96mtr, Discharge: 1600-800lpm@70mtr 1300lpm |
| 54 | CHARGES FOR ELECTRICAL CONNECTION |
| 55 | OD39212/2025-2026:KSEB CONNECTION CHARGES |
| 56 | PUMP ROOM(9*8) |
| 57 | 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 58 | 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 59 | 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 60 | 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers |
| 61 | 2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 62 | 50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete |
| 63 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 64 | 5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 65 | 7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 66 | 50.6.1.3:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure above floor two level up to floor V level thickness 20cm and above in: CM 1:6 ( 1 cement :6 coarse sand) etc complete |
| 67 | 5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 68 | 13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand). |
| 69 | 13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) |
| 70 | 13.48.1:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm |
| 71 | 10.6.2:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20 mm M.S. laths with 1.20 mm thick top cover |
| 72 | 10.7:Providing and fixing ball bearing for rolling shutters. |
| 73 | 10.13.2:Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee- sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with carbon steel galvanised dash fastener of required dia and size ( to be paid for separately) |
| 74 | 9.48.1:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding |
| 75 | 10.2:Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Please Enable Macros to View BoQ information |