| 1 | Repairing and Servicing of Split, Casette, Central, Ductable A.C.s and VRV including spare parts |
| 2 | (A) Split A.C., Cassette A.C., Central A.C. and Ductable A.C. Spare Parts (Daikin/Voltas) |
| 3 | Air Filter Indoor with installation |
| 4 | Compressor Outdoor with installation |
| 5 | A.C. Panel with installation |
| 6 | A.C. Condenser Outdoor with installation |
| 7 | A.C. Drain pipe with installation |
| 8 | A.C. Relay with installation |
| 9 | A.C. Blower Indoor with installation |
| 10 | A.C. Valve Suction and Discharge with installation |
| 11 | Contactor with installation |
| 12 | Capacitor with installation |
| 13 | Indoor PCB with installation |
| 14 | Outdoor PCB with installation |
| 15 | Outdoor fan blade with installation |
| 16 | Outdoor motor with installation |
| 17 | Outdoor sensor with installation |
| 18 | Copper pipe and sleeve with installation |
| 19 | Gas- Refrigerant System (R22, R410,R32) with installation |
| 20 | Condenser coil with installation |
| 21 | Capillary with installation |
| 22 | Fan guard outdoor with installation |
| 23 | Fins motor blade with installation |
| 24 | Fins blade motor with installation |
| 25 | Outdoor electric panel with installation |
| 26 | Indoor evaporator coil with installation |
| 27 | Expansion valve Indoor with installation |
| 28 | Indoor water tray with installation |
| 29 | Indoor sensor with installation |
| 30 | Flare nuts with installation |
| 31 | Connection valve with installation |
| 32 | Full Indoor Unit for Split A.C. with installation |
| 33 | Full Outdoor Unit for Split A.C. with installation |
| 34 | Copper Refrigerant Pipe Per Meter with installation |
| 35 | Drain Hose Indoor with installation |
| 36 | Drain Hose Outdoor with installation |
| 37 | Motor Fan Indoor with installation |
| 38 | Motor Fan Outdoor with installation |
| 39 | Thermostat Indoor with installation |
| 40 | Drain Pan with installation |
| 41 | Grille with installation |
| 42 | Diffusers for Duct with installation |
| 43 | Damper for Duct with installation |
| 44 | Revesring Valve with installation |
| 45 | Control Panel with installation |
| 46 | 4 Pole Contractor with installation |
| 47 | SPPR Contractor with installation |
| 48 | Remote Control with installation |
| 49 | Stand for Outdoor unit of 1 ton A.C. with installation |
| 50 | Stand for Outdoor unit of 1.5 ton A.C. with installation |
| 51 | Stand for Outdoor unit of 2 ton A.C. with installation |
| 52 | Air Conditioner Outdoor unit Universal Wall Mount Bracket Set (Stainless Steel) with installation |
| 53 | Universal High Quality Air Conditioner Indoor Unit Stand 1 Shelf Bracket (Stainless Steel) with installation |
| 54 | Installation Charge of A.C. |
| 55 | Un-installation and Shifting Charge of A.C. |
| 56 | Charge For A.C. Cleaning with Jet Pump (2 time in One Year) per ton rate |
| 57 | Service/Repair Charge other than all above mentioned Items/Parts |
| 58 | (B) V.R.V. (Variable Refrigerant Value) Spare Parts (Daikin) |
| 59 | Compressor with installation |
| 60 | Invertor compressor with installation |
| 61 | Copper pipe and sleeve with installation |
| 62 | Air filter with installation |
| 63 | Outdoor Condenser with installation |
| 64 | Outdoor fan blade with installation |
| 65 | Outdoor fan motor with installation |
| 66 | Outdoor main PCB with installation |
| 67 | Outdoor inveter PCB with installation |
| 68 | Outdoor power control PCB with installation |
| 69 | Outdoor Electric wire with installation |
| 70 | Indoor outdoor communication wire with installation |
| 71 | Gas charging valve with installation |
| 72 | Discharge and suction valve with installation |
| 73 | Indoor swing blade with installation |
| 74 | Indoor swing motor with installation |
| 75 | All sensor outdoor indoor with installation |
| 76 | Gas- Refrigerant System (R22, R410,R32) with installation |
| 77 | Indoor PCB with installation |
| 78 | Thermistor with installation |
| 79 | Heat reclaim ventilator with installation |
| 80 | EEV (Electronic Expansion Valve) with installation |
| 81 | 04 way valve with installation |
| 82 | Indoor cooling coil with installation |
| 83 | Invertor instantaneo USDT (Tether) with installation |
| 84 | Blower motor and rubber with installation |
| 85 | 02 poll contactor with installation |
| 86 | 03 poll contactor with installation |
| 87 | Auxiliary switches with installation |
| 88 | Liquid line filter driers with installation |
| 89 | Grills with installation |
| 90 | Air diffuser with installation |
| 91 | Float switch with installation |
| 92 | Expansion valve with installation |
| 93 | Magnetic contactor with installation |
| 94 | Valve coil with installation |
| 95 | Branch pipe (Refnets) with installation |
| 96 | Noise filter board with installation |
| 97 | Sub assembly PCB with installation |
| 98 | Thermistor assembly with installation |
| 99 | Drain pump with installation |
| 100 | Rectifier board with installation |
| 101 | A.C. cumulator with installation |
| 102 | Float switch with installation |
| 103 | Control Box with installation |
| 104 | Evaporator coil with installation |
| 105 | Thermostat with installation |
| 106 | External Protection Device with installation |
| 107 | EEPROM (Electrically Erasable Programmable Read-Only Memory) with installation |
| 108 | Drain Motor with installation |
| 109 | Swing Flap Motor with installation |
| 110 | Heat Exchange Main Function with installation |
| 111 | Heat Exchange Thermistor with installation |
| 112 | Movement Detector or Floor Temperature Sensor with installation |
| 113 | High Pressure Switch with installation |
| 114 | Low Pressure Main Function with installation |
| 115 | Discharge Temperature Sensor with installation |
| 116 | Ambient Temperature Sensor with installation |
| 117 | Pressure Sensor with installation |
| 118 | Current Sensor with installation |
| 119 | Heat Exchange Gas Temperature with installation |
| 120 | Liquid Temperature Sensor with installation |
| 121 | Inverter PCB with installation |
| 122 | Noise Filter PCB with installation |
| 123 | Over load Protector PCB with installation |
| 124 | Fan Motor PCB with installation |
| 125 | Main PCB with installation |
| 126 | Suction Pipe Thermostat with installation |
| 127 | Mbn Temperature Sensor with installation |
| 128 | Discharge Pipe Sensor with installation |
| 129 | Solnet Coil with installation |
| 130 | Discharge Pressure Switch with installation |
| 131 | High Pressure Switch with installation |
| 132 | Full Indoor Unit for VRV with installation |
| 133 | Full Outdoor Unit for VRV with installation |
| 134 | Copper Pipe Per Meter with installation |
| 135 | Installation Charge of A.C. |
| 136 | Un-installation and shifting Charge of A.C. |
| 137 | Charge For A.C. Cleaning with Jet Pump (2 time in One Year) per HP rate |
| 138 | Service/Repair Charge other than all above mentioned Items/Parts |
| 139 | (C) Air Handling Unit (AHU) Spare Parts |
| 140 | Return Air Sensor with installation |
| 141 | Damper with installation |
| 142 | Filter with installation |
| 143 | Outdoor Air Sensor with installation |
| 144 | Water Flow Sensor with installation |
| 145 | Air Flow Sensor with installation |
| 146 | Fan Motor (10 HP) with installation |
| 147 | Blower with installation |
| 148 | Motor and Blower Connection Belt with installation |
| 149 | Cooling Coil with installation |
| 150 | Duct with installation |
| 151 | Main Electric Panel with installation |
| 152 | (D) Other Electrical Parts |
| 153 | Electric Plug and Socket Acti 9 Metal Unit Single Door 25A 1P+N+E 2 Mod (A.C. Box) with installation |
| 154 | 2.5 sqmm 3 core Copper Cable Wire for A.C. Electrical Uses ISI Mark PVC 3 Meter Length with installation |
| 155 | 2.5 sqmm 3 core Copper Cable Wire for A.C. Electrical Uses ISI Mark PVC per meter with installation |
| 156 | 4 sqmm 3 core Copper Cable Wire for A.C. Electrical Uses ISI Mark PVC per meter with installation |
| 157 | 6 sqmm 3 core Copper Cable Wire for A.C. Electrical Uses ISI Mark PVC per meter with installation |
| 158 | 2.5 sqmm 4 core Copper Cable Wire for A.C. Electrical Uses ISI Mark PVC per meter with installation |
| 159 | 4 sqmm 4 core Copper Cable Wire for A.C. Electrical Uses ISI Mark PVC per meter 8with installation |
| 160 | 6 sqmm 4 core Copper Cable Wire for A.C. Electrical Uses ISI Mark PVC per meter with installation |
| 161 | 10 sqmm 3 core Copper Cable Wire for A.C. Electrical Uses ISI Mark PVC per meter with installation |
| 162 | MCB 20 A SP (Single Pole Miniature Circuit Breaker) with installation |
| 163 | MCB 25 A SP(Single Pole Miniature Circuit Breaker) with installation |
| 164 | MCB 32 A SP (Single Pole Miniature Circuit Breaker) with installation |
| 165 | ELCB 4 Pole 32A with installation |
| 166 | Socket 16A with installation |
| 167 | 16A Heavy Duty Polycarbonate Plastic 3-Pin Plug with installation |
| 168 | 16A Heavy Duty 2-Pin A.C. Plug Top with installation |
| 169 | Stabilizer for 1 Ton A.C. with installation |
| 170 | Stabilizer for 1.5Ton A.C. with installation |
| 171 | Stabilizer for 2 Ton A.C. with installation Please Enable Macros to View BoQ information |