Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including safe disposal of excavated earth as per direction of engineer inchargeand lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil 80 % + 20 % Hard Rock (Blasting Prohibited) |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 3 | Disposal of Excavated earth |
| 4 | Filling of good earth including diging, loading, unloading, royality, carriage & spreading in proper lines and grades and consolidation with power road roller complete. |
| 5 | Grassing with selection no. 1 grass including watering & maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds & fit for mowing including supplying of good earth if needed (the good earth shall be paid separately.) |
| 6 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: |
| 7 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kind of Soil |
| 8 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge All kinds of soil : |
| 9 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 10 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level using 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 11 | Reinforcement for RCC work including straightening cutting,bending,placing in position & binding complete. |
| 12 | Supply & fixing of 40mm wide PVC strips for joints |
| 13 | 40mm thick marble chips flooring rubbed, under layer 28mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) and top layer 12mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from 7 mm to 10mm nominal size, laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 2:3 (2 cement marble powder mix :3 marble chips) by volume including cement slurry and curing complete : Ordinary cement without any pigment. |
| 14 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form work for: Edges of slabs and breaks in floors and walls under 20 cm wide |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases of columns etc. for mass concrete |
| 17 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 18 | Painting with synthetic enamel paint of approved brand and manufactureto give an even shade. Two or more coat on new work. |
| 19 | Providing and fixing of cricket prctice pitch net as per direction of engineer in charge |
| 20 | Providing & fixing PVC Flexi Wickets 1 No. set of 3 wickets, 1 No stump on other side complete as per direction of engineer incharge |
| 21 | Consolidation of sub grade with PRR of 8-10 tonne capacity |
| 22 | Supplying and filling in plinth with fine sand under floors including, watering,ramming, consolidating and dressing complete.in two layers |
| 23 | Dry brick pitching half brick thick in drains including supply of bricks andpreparing the surface complete. With common burnt clay (non modular) bricks of classdesignation 7.5 (in two layer) |
| 24 | Providing and laying 75mm thick compacted bed of dry brick aggregate40mm thick nominal size including spreading, well rammed, consolidatedand grouted with fine sand including finishing smooth etc. complete as perdirection of Engineer-in-charge |
| 25 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 26 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 27 | RBM filling in Sitting tiers including carriage of material to site by mechanical means, compaction complete job |
| 28 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) in coarse sand |
| 29 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels (Area of slab over 0.5 sqm) |
| 30 | Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 31 | Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter withbitumen and G.I limpet washers or with G.I. limpet washers filled withwhite lead, including a coat of approved steel primer and two coats ofapproved paint on overlapping of sheets complete (upto any pitch inhorizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gram/m2 |
| 32 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 33 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level in 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 34 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etcupto floor V level, including curing but excluding the cost of centring, shuttering and finishing with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 35 | Retaining walls, return walls, walls (any thickness) including attached pilasters buttresses, plinth and string course fillets, kerbs andsteps etc |
| 36 | Weep Holes @ 1.2 m c/c in 2 layers, Width =(0.45+0.79)/2Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes 75 mm diametre |
| 37 | Stone filling behind R wall in layers |
| 38 | providing laying and compacting of stone aggregate of size range 63mm -45mm to wbm specification including screening sorting spreading to template and consolidation with power road roller complete |
| 39 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 40 | Providing and fixing of flags of Sating cloth of different colours including sewing and printing of logo. Complete job as per direction of engineer Incharge |
| 41 | Providing and fixing ACP main board 3mm thickness on 1 x 1 inch tubular frame with writing of Name of stadium etc as per direction of engineer incharge |
| 42 | Centring and shuttering including strutting, propping etc. and removal of form work for Lintel, beams, plinth beams, girders, bressumers and cantilevers |
| 43 | Steel work welded in built up section framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer. |
| 44 | Providing and fixing G.I Chain link Fabric fencing of required width in mesh size 50x50mm including strengthening with 2mm dia wire or nuts, bolts and washers as required complete as per direction of Engineer in Charge Made of G.I wire dia 4mm |
| 45 | Finishing wall with premium acrylic smooth exterior paint with silicone additives of required shade on New work (two or more coats applied @ 1.43 liter/10sqm over and including priming coat of water exterior paint applied @ 2.20kg/10sqm) |
| 46 | Applying priming coat: With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel galvanized iron/steel works |
| 47 | Supply and laying of PVC insulated and PVC sheathed / xlpe aluminium power cable of 1.1 KV grade of following sizes on surface / direct in ground including sand cushioning protective covering and refilling the trench as required as per direction of Engineer Incharge 16 sq. mm 2 core |
| 48 | Supply and laying of PVC insulated unsheathed bright annealed bare copper industrial cable for voltage grade upto 1100V as per IS694:1990 3 core 4 sq. mm |
| 49 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm |
| 50 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door SPN MCBDB |
| 51 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral 32 Amp |
| 52 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral 63 Amp |
| 53 | Installation, Testing and commissioning IP 67 Flood lights 200 watt minimum Luminous flux of luminaire 120 Lm/w, Colour temperature of 5700K, Neutral white, CRI > 80, 50,000 operating hours with PCLens and necessary wire for connection and other accessories required for fixing lights on existing Poles. Firm has to submit originallity certificate of material from OEM or Authorized Distributor with 05 years of warranty. |
| 54 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 55 | Centering and shuttering including strutting, propping etc. and removal of form work for: Suspended floors, roofs, landings, balconies and access platforms |
| 56 | 6MM CEMENT PLASTER6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 57 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 coarse sand) |
| 58 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm |
| 59 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown |
| 60 | Providing and fixing 1st quality ceramic glazed floor tiles conforming toIS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete |
| 61 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or withdash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):Sal wood |
| 62 | Providing and fixing carbon steel galvanized (minimum coating 5micron)dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2 ) counter sunk head, comprising of 10 m dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete masonry etc. as per direction of Engineer-in-charge. 10x160mm |
| 63 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. Second class deodar wood 35 mm thick |
| 64 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thickDecorative ply wood one side decorative veneer andcommercial veneer on other face (type 1) conforming IS 1328 BWR type |
| 65 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class deodar wood 35 mm thick |
| 66 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : Second class deodar wood 35 mm thick |
| 67 | Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 68 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300x16 mm |
| 69 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 300x10 mm |
| 70 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 200x10 mm |
| 71 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 100x10 mm |
| 72 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 125 mm |
| 73 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 100 mm |
| 74 | Providing and fixing aluminum casement stays, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 75 | Providing & laying damp-proof Course 40 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone agg 12.5 mm nominal size) and curing complete |
| 76 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 77 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid. |
| 78 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 79 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings |
| 80 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour:Waste coupling 31mm of 79 mm length and 62 mm breadthweighing not less than 45gms |
| 81 | Providing and fixing toilet paper holder with Flap made out of C.P Brass |
| 82 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete: Flexible pipe 32 mm |
| 83 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm |
| 84 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms. |
| 85 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour:. 600 mm long towel rail with total length of 645 mm, 78 mm wide and effective height of 88 mm, weighing not less than 190 gms. |
| 86 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge |
| 87 | Providing and fixing PTMT grating of approved quality and colour circular type 125 mm nominal dia with 25mm waste hole |
| 88 | Providing and fixing PTMT grating of approved quality and colour 150 mm nominal size square 100 mm diameter of the inner hinged round grating. |
| 89 | Providing and fixing 15 mm nominal bore C.P. stop cock (concealed) of standard design and of approved make conforming to IS : 8931 |
| 90 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet 150 mm diameter |
| 91 | Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms |
| 92 | Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 93 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 |
| 94 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 95 | Providing and fixing unplasticised PVC connection pipe with brass unions: 45 cm length 15 mm nominal bore |
| 96 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore |
| 97 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 98 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes110 mm diametre |
| 99 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes 75 mm diametre |
| 100 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Bend 87.5° 75 mm bend |
| 101 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion 110 mm Bend 87.5° |
| 102 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot and cold water supply, including allCPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. 20mm nominal outer dia pipes.20mm nominal outer dia pipes. |
| 103 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot and cold water supply, including allCPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. 25mm nominal outer dia pipes.25mm nominal outer dia pipes. |
| 104 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. External work including trenching, refilling etc 32mm nominal outer dia pipes |
| 105 | Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brick honey comb shaft with common burnt clay (non modular) bricks of class designation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design |
| 106 | Demolishing brick work manually/by mechanical means includingstacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge In cement mortar |
| 107 | Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 108 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVCinsulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 109 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 110 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 111 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 112 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 113 | Supplying and fixing two module stepped type electronic fanregulator on the existing modular plate switch box includingconnections but excluding modular plate etc. as required. |
| 114 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet |
| 115 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch |
| 116 | Supplying and fixing 5 amps. to 32 amps.rating 240 volts 'C' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required .Single Pole |
| 117 | Supplying and fixing 5 amps. to 32 amps.rating 240 volts 'C' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral |
| 118 | Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door |
| 119 | Supplying and Fixing of Following Ratings of D.P MCB 240 Volts \\"C\\" Series in the Existing MCB D.B complete with connections,Testing and Commissioning Etc. as Required. 63 A |
| 120 | Supplying and fixing following rating, double pole, (single phaseand neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A |
| 121 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 122 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metrebelow ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 123 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 124 | Supply, Installation, testing and commissioning of 20/22 watt 4'-0\\" Tube light fixture aluminium housing with 2000 lumens and minimum efficasy of 100 lumens / watt power factor More than 90 and 5000 burning hours |
| 125 | Supply, Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm dia sweep ceiling fan |
| 126 | Supply Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Exhaust fan 200mm |
| 127 | Supplying and fixing DP Switch MCB type 32 Amp for AC. |
| 128 | Supplying and fixing concealed metal box for fan of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 150 mm dia X 100 mm deep |
| 129 | Supply, Installation, testing and commissioning of angle holder including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 130 | Supply, Installation, testing and commissioning of lED light Bulb 9 watt |
| 131 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required 1 or 2 Module (75mmX75mm) |
| 132 | Supply, Installation, testing and commissioning of 1PH Self Priming Monoblock Pump to lift water from under groung Sump tank to OHT |
| 133 | Installation testing and comissioning of linear surface wall mounted 10/11 watt light luminaire with Luminous efficiency of luminaire 100 lm/W; color rendering index Ra > 80; minimum system lumen output of 1000 lumens and maximum system wattage of 12W; Dimension :- 595 mm Body of extruded aluminium profile and polycarbonate cover. |
| 134 | Providing and fixing of PVC insulated and PVC Sheated / XLPE Aluminium Power cable of 1.1KVgrade of surfaced / direct in groud including excavation sand cushoning protective cover and refileing armoured cable 16 sqmm 2 core |
| 135 | Treatment of soil under existing floors using chemical emulsion (Chlorophriphos/Lindane E.C. 20% with 1% concentration) @ one litre per hole, 300mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement :2 coarse sand) to match the existing floor: |
| 136 | Providing, Laying, spreading and compacting RBM as per specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, watering and compacting to the required density |
| 137 | P/L and compacting stone agrregates of different sizes to form contour and elevation to the desired level as per the Drawing and instruction of Engineer Iincharge (size 40 mm /20 mm/10mm ) down black stone aggregate up to a depth of 300mm from below primary backing incl all carriage. Layers of stone to be rolled as per desired slope and compaction using 8-10 tonnes Road roller over open area & pitch roller over areas with drainage pipes. |
| 138 | Supply and installation of artificial UV resistanat polyethylene synthetic grass with rigid monofilment yarn, minimum 40mm pile height and 1250g/sqm pile weight with total carpet weight not less than 2500g/sqm and infiill in the ratio of 2:1 with sand(size of sand 0.2mm-1.0mm) 15mm (minimum)height and Rubber 8mm(minimum)height infill weight not less than 2.25kg/sft .The stitch rate per meter should be minimum of 285 All line marking shall be white, unless in the drawings. line marking shall be sitched 'tufted' material (painted lines are not acceptable) the carpet should be laid as per the manufacturers manual incl. All applicable taxes, Lavies, Octoria, transportation loading/unloading complete. (Including Maintenace of 3 years by way of brushing and adding infill as and when required) |
| 139 | Providing of Fixing Height Adjustable Fixed Volley Poles with Net and Anteena |
| 140 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000x450x50 mm reinforced with 8 mm dia four nos longitudinal and 9nos cross sectional T.M.T hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S flats of size 50mmx1.6mm complete all as per direction of Engineer-in-charge. |
| 141 | Carriage of sand material from source to site of work M.T including & unloading complete |
| 142 | Carriage of material from source to site of work M.T including & unloading complete agg for avg Lead |
| 143 | carriage of Brick for a distance km by mt Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail