| 1 | SITC of 10 mm2 1C/10 mm2 3.5C as eqv. to 1C length as per site reqr. PVC/XLPE insulated 1100V flexible industrial copper cable for electric installations The cable shall be of standard quality confirming to BIS (Finolex/ Anchor/ L&T/ Havells/ KEI, or eqv.). The job includes cutting and crimping with cr. tool, etc. All the tools and tackles required for completion of job in a safe manner is to be provided by the firm. The details/spec. will be provided by engineer in charge. |
| 2 | SITC of 2.5 mm2 3C PVC insulated 1100V flexible industrial copper cable for submersible pump motors the cable shall be of standard quality confirming to BIS (Finolex/ Anchor/ L&T/ Havells/ KEI, or eqv.). The job includes cutting and crimping with cr. tool, etc. All the tools and tackles required for completion of job in a safe manner is to be provided by the firm. The details/spec. will be provided by engineer in charge. |
| 3 | SITC of 2.5 mm2 2C PVC insulated 1100V flexible copper cable for electrical installations with allied fittings. The cable shall be of standard quality confirming to BIS (Finolex/ Anchor/ L&T/ Havells/ KEI, or eqv.). The details/spec. will be provided by engineer in charge. All the tools and tackles required for completion of job in a safe manner is to be provided by the firm. |
| 4 | SITC of 1.5 mm2 PVC insulated 1100V flexible copper cable for electrical installations with allied fittings. The cable shall be of standard quality confirming to BIS (Finolex/ Anchor/ L&T/ Havells/ KEI, or eqv.). The details/spec. will be provided by engineer in charge. All the tools and tackles required for completion of job in a safe manner is to be provided by the firm. |
| 5 | Installation, testing and commissioning of three phase LT electric control panel complete with connection, internal wiring etc. connections, caliberation & settings to contactors, mcbs/mccbs, relays, starters, etc. The job includes the cost of accessories, thimbles, drilling, bolting, welding as required and testing on full load. The details of the work/items shall be provided by the concerned engineer of EM works. All the tools and tackles required for completion of job in a safe manner is to be provided by the firm. |
| 6 | Installation, testing and commissioning of 50 KVA three phase voltage stabilizer with T. oil of 11 KVA grade as per IS:335 with dielectric strength of 5 KV at 4m air gap to be filled up to top level (5-10 ltr) or as per reqr. The job includes the cost of T.oil and thimbles as required and testing on full load. The details of the work/items shall be provided by the concerned engineer of EM works. All the tools and tackles required for completion of job in a safe manner is to be provided by the firm. |
| 7 | Installation, testing and commissioning of three phase CO complete with connection, etc. The job includes drilling, fixing, bolting, etc and the cost of accessories required in safe execution of the job and testing on full load. The details of the work/items shall be provided by the concerned engineer of EM works. All the tools and tackles required for completion of job in a safe manner is to be provided by the firm. |
| 8 | SITC of 100 W LED floodlight, cool white 5000/ 6000/ 6500K IP 65/66, CRI >80 with allied items with two year warranty. (Havells/ Philips/ Osram/Syska/Wipro/Ledvance/Panasonic/GM or eqv.). The details/spec. will be provided by engineer in charge. All the tools and tackles required for completion of job in a safe manner is to be provided by the firm. |
| 9 | SITC of 50 W LED floodlight/St.light, cool white 5000/ 6000/ 6500K IP 65/66, CRI >80 with allied items with two year warranty. (Havells/ Philips/ Osram/ Ledvance/Panasonic/GM or eqv.). The details/spec. will be provided by engineer in charge. All the tools and tackles required for completion of job in a safe manner is to be provided by the firm. |
| 10 | Providing and fitting of 25mm Polypropylene corrugated flexible conduit for enclosing the cables with allied items incl. clamps. The item PCFC shall be of standard quality. All the tools and tackles required for completion of job in a safe manner is to be provided by the firm. The details/spec. will be provided by engineer in charge. |
| 11 | Providing, laying & fixing of 11 KV, 8 mm anti-skid & shock proof insulation rubber mats (5 sqmm) confirming to IS 15652 with bonding tube on the floor under electric machinery & covering area around electro-mechanical equipment. Providing of industrial rubber 11 KV electrical shock proof safety gloves (01 pairs), Rain coat (03), Insulation boot (01 pairs), Gum boot (01 pair), Anticut glooves CL- 5/4 P and AL-4 (04 pairs) for handling electrical equipments/ connections. The details of the work/item shall be provided by the concerned engineer of EM works. |
| 12 | Supply, installation, testing and commissioning of TPN MCCB/ Circuit Breaker with 415V heavy duty wall mounted corr. resistant steel sheet enclosure IP3X, TP/FP protecting the circuit breaker from dust, moisture, and accidental contact of following capacity: - Capacity---≥63 A. BC -----25 KA at 415V (Ics= 100% Icu) Type of release----- Thermal magnetic with adjustable settings Rated Voltage----415+- 15% Volts. Protection----Short circuit, Overload IS/IEC:---60898/60947(2) The MCCB shall be of standard quality conforming to above standards (ABB / L&T d-sine/ Schneider/ Havells, Legrand). The item used shall be of OEM. All the tools and tackles required for completion of job in a safe manner is to be provided by the firm. The details/spec. will be provided by engineer in charge. |
| 13 | Providing and fitting of switch board with 10/6A-SP switch, 240V, 50 HZ AC switch combined with box wall mount (03), 6 A 3/5 pin socket (01). (Havells, Wipro, GM or equi.). All the tools and tackles required for completion of job in a safe manner is to be provided by the firm. The details/spec. will be provided by engineer in charge of EM works. |
| 14 | Providing of open D-end spanner (6-28) set with cover and stripping tool/cable cutter (01 no.). (Taparia, Stanley, Goodyear). |
| 15 | Providing of combination plier joint cutter (01 no) and screw driver set cum tester (01 no) (Taparia/Stanley). |
| 16 | SITC of bus bar (with voltmeter) heavy duty copper strips (TPN) suitable to sustain load of 100 A to be drilled with equidistant holes including cutting, drilling, bolting, welding as reqd. etc. Rating:-----≥100 A, Voltage: --------415 V. The strips are to be fixed on specific insulators meant for the bus bar and are to be fixed (Anchor/ SSK/ Havells/ L&T/Bnt./Eqv.). The details/spec. will be provided by engineer in charge of EM works. All the tools and tackles required for completion of job in a safe manner is to be provided by the firm. |
| 17 | P/T of manu. high-grade metal/hardened steel crimping tool/cable lug crimping plier of reputed make for copper/ aluminum terminals, CD range 6-50 mm2 |
| 18 | Providing and fitting of GI nuts and bolts of assorted size with washers incl. allied items with cost of tools used. Please Enable Macros to View BoQ information |