| 1 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plasterincluding disposal of rubbish to the dumping ground within 50m lead.As per pwd general bsr 2022 code no. 14.55ch no. B-14 |
| 2 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6graded stone aggregate 20mm nominal size).As per PWD BSR 2022 item no. 3.1.4 CH no. B-03 |
| 3 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : as per pwd bsr 2022 ch no B-5 code 5.2.2 |
| 4 | Add extra over item of brick work with class designation 10.0 in substitution of class designation 7.5. as per pwd bsr 2022 ch no B-5 code 5.18.1 |
| 5 | Plaster on new surface on wall in cement sand mortar 1:6 including racking of joints etc. Complete fine finish :20mm thick. As per pwd general bsr 2022 code no 12.3.2 ch no. B-12 |
| 6 | Precast terrazo tiles of approved make, 20mm thick withmarble chips of size upto 6mm laid in floors, and landing,jointed with neat cement slurry mixed with pigment to matchthe shade of the tiles, including rubbing and polishingcomplete on 20mm thick bed of cement sand mortar 1 : 4. Light shade using white cement .as per pwd bsr 2022 ch no B-11.13.2 code -11 |
| 7 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:old work.same colour.As per pwd bsr 2022 code no 12.37.2(b) |
| 8 | Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding. Old work. As per pwd bsr 2022 code no 14.41.2 |
| 9 | Providing and fixing 1st quality standardmarble printed / granite shade or dark shade tiles in glazed tiles confirming to IS:13753 & Is:15622 of size up to 300*450mm in walls, steps,pillars etc. Laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete ( excluding the cost of cement plaster on walls and pillars). As per pwd general bsr 2022 code no. 7.12 +7.14ch no. B-7 |
| 10 | Providing and fixing 1st quality MAT finished ceramic tile size300*300mm confirming to IS : 15622 colour such as marble printed / granite shade or dark shade tiles in floor , steps , pillars etc. Laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4).As per pwd general bsr 2018 code no. 7.13 ch no. B-7 |
| 11 | Providing and fixing in cement sand mortar 1 : 4 single paitam (rebated) stone doors windows and ventilator frames of approved quarry :Size 75x 75mm as per pwd bsr 2021 ch no B-15 code 15.24.2 |
| 12 | Providing and fixing in cement sand mortar 1 : 4 double paitam (rebated) stone doors windows and ventilator frames of approved quarry :Size 100x 75mm as per pwd bsr 2021 ch no B-15 code 15.25.1 |
| 13 | Supplying and fixing in walls machine cut and polished stone shelves, tands and in CM 1:3 with machine cut edges :Kota stone minimum 30mm thick.. As per pwd bsr 2022 ch no B-6 code 6.17.3 |
| 14 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : One or more coats on Old Work as per pwd bsr 2022 ch 12.46.2 |
| 15 | P&f steel glazed doors , window and ventilators shutters of standerd rolled steel section joints mitred and welded with steel lungs 13*3 mm , 10 cm long embedded in cement concrete block 15*10*10 cm of 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggrigate 20 mm nominal size ) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with and nuts as required including providing and fixing of plain glass panes 4 mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws completes including priming coat of approvel steel primer , excluding the cost of metal beading and other fitting except necessary hings of pivots steel handles pegs stay etc. as required : window fixed .As per pwd general bsr 2022 code no. 9.19.2 ch no. B-9 |
| 16 | Repair of existing steel glazed doors, windows and ventilator, MS sheet door, garge doors, compound wall gates etc. by welding drilling complete include. Cost of welding rods and hire charge of welding meachine and TP etc complete.As per pwd general bsr 2022 code no. 13.23 ch no. B-13 |
| 17 | Renewing glass panes, with putty and nails wherever necessary: Float glass panes of thickness 4 mm . As per pwd general bsr 2022 code no. 13.4.1. ch no. B-13 |
| 18 | Repair to damaged cement plaster of stone chajja with CM 1 : 3 of required thickness on top & bottom as per existing pattern and making patta etc complete up to three floor level as per direction of Engineer in charge including all necessary scoffolding etc.As per pwd general bsr 2022 code no. 13.31. ch no. B-13 |
| 19 | Providing & fixing door, window, chowkhats and other frames, including antitermite treatment, M.S. flat, hold fasts of size 250 x 40 x 3mm fixed with M.S. bolt 5mm dia 50mm long duly embedded in cement concrete M-15 grade :Sheesham wood Grade - I.As per PWD BSR 2022 item no. 8.1.3 page no. B-8 |
| 20 | SS wire gauge 14 mesh x 24 gauge.As per PWD BSR 2022 item no. 8.6.9 page no. B-8 |
| 21 | Providing & Fixing of ward robe shutters made out of 19mm thick BWP block board ISI of superior quality make with following details :-Front side finishing with 1mm thick superior quality mica approved make and 0.8mm thick approved shade mica in the inner side. Covering with teak wood beading 25x12mm all the sides of shutter & 35x12mm on outer frame for making good the wall joint including heavy brass S.S. fittings (Handle 200mm 2 Nos., Tower Bolt 150mm 2 Nos., Brass Lock 1 Nos., Magnetic Catcher 2 Nos., Brass Hinges 75x40x2.5 mm 6 Nos., SS Hanger Rod 20mm dia) complete as per drawing and design approved by Engineer in Charge. As per PWD BSR 2022 item no. 8.34 ch no. B-8 |
| 22 | Providing & Fixing BWR ISI marked 19 mm board of approved make for making wardrobe/shelves and other furniture with fevicol & nails complete as per approved by engineer in charge. As per PWD BSR 2022 item no. 8.38 ch no. B-8 |
| 23 | Providing & Fixing Commercial Ply as per IS 710 : 1976 BWR of approved make for making wardrobe/shelves and other furniture with fevicol & nails complete as per approved by engineer in charge. 12 mm thick.As per PWD BSR 2022 item no. 8.39(ii) ch no. B-8 |
| 24 | Providing & Fixing mica of approved make for inner/outer side of shutters with fevicol & nails complete as per approved by engineer in charge.0.8mm thick mica.As per PWD BSR 2022 item no. 8.35(ii) ch no. B-8 |
| 25 | Providing & Fixing telescopic channel of approved make for drawers with screws complete as per approved by engineer in charge.600mm long As per PWD BSR 2022 item no. 8.40(v)ch no. B-8 |
| 26 | Providing & Fixing drawer handle of approved make for drawers with screws complete as per approved by engineer in charge.150mm long .As per PWD BSR 2022 item no. 8.41(ii) ch no. B-8 |
| 27 | Providing & Fixing drawer lock of approved make for drawers with screws complete as per approved by engineer in charge.As per PWD BSR 2022 item no. 8.42 ch no. B-8 |
| 28 | 12 mm thick glass As per PWD BSR 2022 item no. 8.6.7 ch no. B-8 |
| 29 | Providing and fixing Nigeria / Ghana /Ivory Coast Teak wood grade-I mouldings and beadings in doors and windows size :-25x20 mm As per PWD BSR 2022 item no. 8.23.4 ch no. B-8 |
| 30 | Providing and fixing IS : 3564 marked aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. complete. As per PWD BSR 2022 item no. 8.27 ch no. B-8 |
| 31 | Providing and applying Melamine polish on teak wood work of approved brand and manufacture to give an even shade with two or more coats by compressor including sand papering, wood filler coat etc complete in all respect:New Surface as per pwd bsr 2022 ch no 12 code 12.50.1 |
| 32 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work l) 20mm nominal size.as per pwd bsr 2022 ch no s-1 code 2.38.2 |
| 33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Enternal work Exposed on wall)20mm nominal size.as per pwd bsr 2022 ch no s-1 code 2.39.2 |
| 34 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Enternal work Exposed on wall)25 mm nominal size.as per pwd bsr 2022 ch no s-1 code 2.39.3 |
| 35 | P&F on wall face UPVC rain and soil waste (SWR) Pipes conforming to IS:13592 including jointing with seal ring conforming to IS:5382 Leaving 10 mm gap for thermal expansion; single socket:type B: 110 mm dia . As per pwd general bsr 2019 code no 3.32.2 ch no S-3 |
| 36 | single tee with door 110 mm dia .As per pwd general bsr 2022 code no. 3.45.16.ii ch no. S-3 |
| 37 | single bend with door 87.5 degree 110 mm dia .As per pwd general bsr 2022 code no. 3.45.4.ii ch no. S-3 |
| 38 | P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: As per pwd bsr ch no 4-1 code 1.2.1 |
| 39 | P & F Mixing Range (15mm)C.P. sink mixer with swinging spout J-pipe..As per pwd general bsr 2022 code no. 2.21.3 ch no.S-2 |
| 40 | P & F shower arm 15 mm dia of approved quality /make:C.P. Brass heavy and superior quality 370 mm projection.As per pwd general bsr 2022 code no. 1.54.4 ch no.S-1 |
| 41 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet of approved quality/make.C.P. brass of Heavy & superior quality, revolving with adjustable key 150mm.As per pwd bsr 2022 code no 1.55.3 Ch S-1 |
| 42 | P & F Inlet Connection (Angle Valves) Superior quality,of approved make, for Wash basin,Gyser etc.: C.P. Inlet connection 15 mm Brass with 37 cm long pipe and nut. (IS:8931 marked). As per PWD BSR 2022 item no 2.12.2. CH no - S2 |
| 43 | Hand shower with 8 mm dia 1 mt long PVC tube & wall hook complete.As per PWD BSR 2022 item no 2.33.21 CH no - S2 |
| 44 | P & F PVC Storage Tank (IS:12701 marked indicating the BIS license No.) of approved make with cover, 25 mm dia 1 M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including placing on terrace( at all floors),making connection etc. complete of approved design. 1000 ltr . as per pwd bsr 2022 ch no 2.26.5 |
| 45 | Construction of chamber in all type of soil with 230/300 mm thick masonry in CM 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr.Inside size 450 X 450 mm depth upto 0.5 M Cement cover with frame. as per pwd bsr 2022 items no. 3.21.1, ch no. S 3 |
| 46 | P & F kitchen & Lab Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up to floor level complete including cutting and making good the wall & floor :1 mm thick stainless steel AISI-304 & IS 13983-1994 KItchen sink of approved make as per er incharge with large waste coupling .37 x 18 x 7 17x15x7 (with drain board)as per pwd bsr 2022 ch no s-1 code 1.38.9.4 |
| 47 | Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering.M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size. as per pwd bsr 2022 ch no B-3 code 3.2.2 |
| 48 | Providing and Applying ACRYLIC emulsion polymer waterproofing chemical coating, on over roof on over roof slabs/terrace/balconies/parapet wall etc.with following method/specification:Paint the surface with regular paint brush so as to obtain approximately 0.3mm thickness coating. apply the 2nd coat next day at right angles to the 1st coat so that total thickness of the coating should be approximately 0.6mm coverage by using above formulation will be 40 ft2/ litre of chemical. painted surface does not require any external water curing since chemical will hold sufficient water for curing.After the primer coat Apply 2 coats of modified acrylic emulsion polymer water proofing compound having solar heat reduction properties coating @ 0.330 KG/SQM on the surface of the interval of 3-4 hours. Undulation on the surface is repair before the waterproofing work.as per pwd bsr 2022 code no 15.29 CH B-15 |
| 49 | Providing & Fixing of of ventilating fans Capacitor start, copper wounded, single phase with PVC impeller, ABS body, automatic openable louver shutter in existing opening including making connection, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR ..200mm sweep As Per PWD Electric BSR 2022 item no. ch no 15 15.13.2 page no. 82 : 200mm sweep |
| 50 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit & it's accessories, round tiles,Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch,Modular plate with grid plate, screws, making connections, testing etc. as required. short point (up to 3 mtr.) As per PWD BSR 2022 item no. 1.1.1 |
| 51 | Medium point (up to 6 mtr.) As per PWD BSR 2022 item no. 1.1.2 |
| 52 | long point (up to 6 mtr.) As per PWD BSR 2022 item no. 1.1.2 |
| 53 | Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification of Wiring accessories refer Chapter E - 07 related item & For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. As per PWD BSR 2022 item no 7.37. CH no.7 |
| 54 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 2 x4.0 sqmm As per pwd bsr 2022 item no 4.1.11 ch no 4 |
| 55 | S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required including cutting the wall, covering conduit and making good the same as required. 25 mm.As per pwd electric bsr 2022 code no. 1.4.2 |
| 56 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR2 x 2.5 sq.mm. As per pwd electric bsr 2022 code no. 4.1.6 |
| 57 | Pointing on stone slab ceiling with cement mortar 1:2 (1 cement : 2 fine sand): Flush/ Ruled pointing .as per pwd bsr 2022 code no 12.32 ch B-12 |
| 58 | P & F 1st quality Vitrified tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete. : size 600 mm X 600 mm . As per pwd general bsr 2022 code no.7.18.2 ch no. B-7 |
| 59 | P & F Automatic Flushing Cistern of first quality (IS : 774 mark) of approved make fitting, siphon with copper tube, C.I. brackets complete including cutting and making good the wall : WVC Automatic flushing cistern - 10 Litre Capacity. As per pwd general bsr 2022 code no. 1.21ch no.S-1 |
| 60 | P&F external grade board solid core single / Double leaf flush door shutter IS : 2202 ( part -2) 1996 marked using phenole formel dehyderesin in glue both side with approved stainless steel fitting complete as per annxure' A' : 35 mm thickdecorative teak vaneer one side . As per PWD BSR 2022 item no. 8.13.3.2 page no. B-8 |
| 61 | Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint.As per pwd bsr 2022 code no 9.17 ch B-17 |
| 62 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.as per pwd bsr 2022 code no 9.5 ch B-9 Please Enable Macros to View BoQ information |