| 1 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 2 | a) 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 3 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 4 | a) 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 5 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 6 | a) Above 95 sq. mm and upto 185 sq. mm |
| 7 | SITC of 11 TR ductable Split AC,twin circuit,03 ph, 415 Volts unit complete with all components like air cooled condenser , indoor coil unit, blower, Filters, controller, display unit and outdoor copper condensers unit with scroll compressors ,fan etc including pressure testing, vacuumising the system, gas charging & Installation of all hardware components,hanging on ceiling the IDU with suitable size bolts/brackets etc. as required make:- Hitachi Toushi Pro series R410A Model No.:PAG120SSHDDA3Z1 (or equivalent model in Mitsubishi/ Carrier/ Blue star/Daikin/Fujitsu). |
| 8 | Providing and fixing of refrigerant hard drawn copper pipes of following sizes (Suction & delivery) of split type AC i/c providing electrical cables (4 core 4sqmm), insulation, extra gas charging, cutting, drilling holes on the wall for passing gas pipes , fixing suitable size PVC pipe on the wall through the holes and cementing, painting to give an even look and smooth finish and covering with PVC non adhessive tape over the 13 mm thick closed nitrile foam insulation of refrigerant pipes and as per the direction of E-in-C |
| 9 | a) Refrigerant pipes of Sizes 7/8\\" & 1/2\\" |
| 10 | Supplying and fixing of air ducting fabricated out of GI Sheet confirming to latest IS:655 and complete with dampers, tab hangers, anchor fasteners, etc and complete as required and as indicated below. GI Sheet shall be grade 120 confirming to latest IS:277 |
| 11 | a) Duct with 0.8mm thick GI sheet (22SWG) |
| 12 | b) Duct with 0.63mm thick GI sheet(24SWG) |
| 13 | Supply & Fixing of air powder coated Aluminium grills/diffusers with / without G.I volume control dampers of following description with necessary frame work complete as required. |
| 14 | a) Supply Air Ext.Al. Square/rectangular Diffusers with VCD |
| 15 | b) Return Air Ext.Al. Grilles 0,15,30 &45 deg. deflection without VCD |
| 16 | Supply and fixing of Thermal insulation of following thickness for supply air ducting made of Class 0 endless sheet with self adhesive pre-covered with Alumunium foil,make ARMAFLEX or equivalent, complete as required. |
| 17 | a) 19 mm (code no COA-19mm/EAL ) |
| 18 | Supply and fixing Acoustic insulation of supply air ducting immediately after discharge of packaged unit made of 20 mm thick self adhesive Ductliner sheets make:- ARMASOUND super silence ductliner,code no ASD-SA-140-20 or equivalent, complete as required. |
| 19 | Fabrication and fixing of stand/Pedestal required for out door unit & bracket for AC duct supports made of suitable size MS Angle/ MS pipes/MS flats including painting with anti corrosive primer and metallic paint as required. |
| 20 | Supplying and fixing of following sizes of CPVC plumbing pipe along with accessories for fixing as drain pipe to IDU of ductable split type Air conditioner in surface/recess make: PRINCE SMARTFIT or equivalent including connections using cpvc cement solvent,providing suitable size union in every 03 metres, elbows, Tee, F.T.A etc ,cutting the wall and making good the same in case as required Make: PRINCE SMARTFIT or equivalent. |
| 21 | a) 25mm |
| 22 | Making of box enclosure for indoor AHU with 19 mm and 12mm marine plywood and suitable size M.S Angle framing of required size, insulating the space inside and outside the enlcosure with Armaflex class 0 sheet COA-13MM/EAL thick insulation and installation of indoor unit of Ductable split Air conditioner, making good the same, the enclosure with two coats of wood primer etc. as per requirement of site and the instruction of E-in-C. |
| 23 | SITC of air curtain 6 feet long with 220V, single phase 50 Hz with 3 motors and 6 blower assembly with a total power consumption of 360 W and air flow of 3000 CFM and complete metal body similar to make :- Chronovex, Model No.:- PCXP1803Y or similar models from any reputed manufacturer. |
| 24 | Supply of 3.5 core, 150 sqmm. ISI marked PVC sheathed/ XLPE armoured Aluminium conductor cable of 1.1 KV grade as required. |
| 25 | SITC of one 'G' frame Double door Panel Board , incomer 250 A \\"AA\\" Frame MCCB and 4 way TP MCCBs G-frame outgoing quivalent to Havells CAT No.IHVG02500400 Including one set Cable ally 4 way equivalent to CAT No. ISSBOU0691, add on Pre-Wired Meter Module with Voltmeter, Ammeter, Selector Switch, CT’s 250/0.5 A with 0.2 accuracy class Control fuse and indicating lights equivalent to CAT No.ISSBOU0707 and supplying and fixing including making connections/ inter-connection of following switchgear etc. as required.a) 'TP MCCB, 250A, 415V,50Hz 36 KA breaking capacity .b) TP MCCB, 63A, 415V, 50 Hz, 10KA Breaking capacity. Please Enable Macros to View BoQ information |