| 1 | Providing and fixing of 50 watt led lights make havells complete in all respect as per derication of Engineer-in-charge. |
| 2 | Providing and fixing DI Flange Adopter of size 200 mm complete in all respect |
| 3 | Providing and fixing DI Flange Adopter of size 300 mm complete in all respect |
| 4 | Designing, Supply and erection of DG set of capacity given below with noise controlled devices acoustic of suitable rating, testing and commissioning of diesel generating set, radiator cooled, 3 phase, 4 wire, 50 cycles 415 plus (-)1% volts AC alternator coupled directly through a set of flexible coupling = 200 KVA The DG set should be according to CPCB IV plus draft notification effective from 1 july 2023 norms or any other upto date norms according to CPCB/Govt. complete in all respect. 200 KVA |
| 5 | Designing, Supply and erection of DG set of capacity given below with noise controlled devices acoustic of suitable rating, testing and commissioning of diesel generating set,radiator cooled, 3 phase, 4 wire, 50 cycles 415 plus (-)1% volts AC alternator coupled directly through a set of flexible coupling = 400 KVA The DG set should be according to CPCBIV plus draft notification effective from 1 july 2023 norms or any other upto date norms according to CPCB/Govt. complete in all respect. 400 KVA |
| 6 | Providing and fixing of channel gate for channel size 1.0 x 1.0 mtr with actuator complete in all respect in satisfaction of engineer-in-charge. |
| 7 | Designing, Supply and erection of DG set of capacity given below with noise controlled devices acoustic of suitablerating, testing and commissioning of diesel generating set, radiator cooled, 3 phase, 4 wire, 50 cycles 415 plus (-)1%volts AC alternator coupled directly through a set of flexible coupling = 100 KVA The DG set should be according to CPCB IV plus draft notification effective from 1 july 2023 norms or any other upto date norms according to PCB/Govt. complete in all respect. 100 KVA |
| 8 | Supplying, erection, testing and commissioning of submersible motor pumping set non clog for sewerage having head 40.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked including all accessories (like SS Pipes, SS Chain (Shackle Chain) ,SS Foundation Bolt, complete base frame, Monorail, Chain Guide Line, Auto Compiling, Duct Foot Bend (D/F Bend) etc. complete in all respect the indicated. LPM -8500 and BHP - 125 |
| 9 | Providing and fixing 250 AMP copper bus bar junction bar complete in all respect.. |
| 10 | Providing and fixing 200 AMP copper bus bar junction bar complete in all respect.. |
| 11 | Providing and fixing aluminum ladder stair 12 Feet long including fitting, jointing, fasner complete in all respect as per design satisfaction Engineer-in-charge |
| 12 | Providing and fixing C.I. sluice valves (with wheel) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : - 300 mm i/d |
| 13 | Supplying, erection, testing and commissioning of submersible motor pumping set non clog for sewerage having head 25.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked including all accessories (like SS Pipes, SS Chain (Shackle Chain) ,SS Foundation Bolt, complete base frame, Monorail, Chain Guide Line, Auto Compiling, Duct Foot Bend (D/F Bend) etc. complete in all respect the indicated. LPM - 5000 X 25 Mtr Head |
| 14 | Providing and fixing Ductile iron double flanged swing check type reflux (non return) valves PN- 1.6 including nuts and bolts, rubber sheet, carriage loading, unloading, stacking, handling, re-handling etc. Complete in all respect = 200 mm i/d ( Pumps) .. |
| 15 | Providing and fixing Ductile iron double flanged swing check type reflux (non return) valves PN- 1.6 including nuts and bolts, rubber sheet, carriage loading, unloading, stacking, handling, re-handling etc. Complete in all respect 300 mm for Rising main |
| 16 | Providing and fixing C.I. sluice valves (with wheel) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : - 200 mm i/d... |
| 17 | Providing and Fixing CI Sluice gate as per IS code : 13349 and IS code : 3042 of size 1200 mm including gear box and actuator of suitable size and capacity with synchronizing with PLC SCADA, including nuts bolts marked with IS code : 1363, Carriage loading unloading stacking handling, re handling from manufacturing unit to site etc. complete in all respect as per design and direction of Engineer -in- charge. Gate size - 1200 x1200 mm, suitable depth. at MPS Nayagaon |
| 18 | Providing and Fixing CI Sluice gate as per IS code : 13349 and IS code : 3042 of size 1500 mm including gear box and actuator of suitable size and capacity with synchronizing with PLC SCADA, including nuts bolts marked with IS code : 1363, Carriage loading unloading stacking handling, re-handling from manufacturing unit to site etc complete in all respect as per design and direction of Engineer -in- charge. Gate size - 1500 x 1500 mm, suitable depth. at MPS Nayagaon. |
| 19 | Providing and fixing D.I. AIR valves complete with all accessories bolts, nuts, rubber insertions etc. 100 mm i/d for rising mains |
| 20 | Providing and fixing Ductile iron double flanged swing check type reflux (non-return) valves PN- 1.6 including nuts and bolts, rubber sheet, carriage loading, unloading, stacking, handling, re-handling etc. Complete in all respect - 600 mm |
| 21 | Providing and fixing C.I. Sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately): - 600 mm i/d |
| 22 | Making of Joint from exiting HDPE pipe to connecting new HDPE pipe of 500 mm o/d including cutting, jointing, labour etc at various site complete in all respect. for rising mainOperation and Maintenance during 5th year |
| 23 | Providing and fixing of EOT Crane of Capacity 3 MT including providing and fixing horizontal Beam and vertical column made from suitable size of MS girders to be installed, Confirms to IS : 3177-807, Class of Duty : 2nd Heavy Duty, Lifting Height : 15 Mtr., Location : outdoor Type, Speed : Hoisting - 3 Mtr / Min. (up and down Motion), Cross Travel – 15 Mtr / Min, Long Travel – 15 Mtr / Min, with 3 MT motorized hoist / chain pulley block. complete in all respect as per design, as per direction and satisfaction of Engineer -in- charge Capacity 3 ton |
| 24 | LT panel board indoor Type 0.415 KV ACB Control Cubical Panel with vertical Isolation Type Breaker as per relevant IS as amended up to date and Additional Specifications, having Capacities as mentioned below, Single break trip free mechanism, manually charged and Auto/Manuelly closing breaker suitable for use on 0.415 kv, 3 phase 50 hz AC Supply with short circuit fault level of 500 Amps Capacity, breaker featured with local ON/OFF Indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 2NO plus 2NC and equipped with following switchgears and accessories including making suitable structure arrangement for installation, control wiring and connections etc. as required ( 3 incoming and 3 outgoing) including provision of APFC Panel of 40 kVAR or as per suitable capacity. 1) ACB, 0.415 kV, 800 Amp, 50 kA- 02 Nos. 2) Changeover Switch 0.415 kV, 800 Amp., 50 kA- 01 Nos. 3) MCCB, 415V, 4 pole, 50 KA .a) 160 Amp.- 3 Nos. (1 No. outgoing for APFC panel) 4) Control panel- Cubicle type control panel suitable for floor mounting made out of 2 mm CR sheet duly powder coated and with following electrical equipments. 5) THERMAL OVER LOAD RELAY- 02 Nos. 6) AUXILARY CONTACTOR a) 95 A (2 NO plus 2 NC) COIL Voltage 220V-02 Nos. b) 95 A (2 NO plus 2 NC) COIL Voltage 220V-02 Nos. c) 95 A (2 NO plus 2 NC) COIL Voltage 220V-02 Nos. 7) Timers for starters- 02 Nos. 8) ELCB (96X96 mm) For all starters- 02 Nos. 9) AIR COOLED AUTO TRANSFORMER STARTER- 02 Nos. a) Frequency of Open. 6 starts/hour (evenly spaced) or as per specification. b) Starting time: Suitable for 12sec starting or as per specification. c) Taps: 50% /65% /80% or as per standard. d) Thermal cut-off: in-built. 10) RYB Indication Light as per outgoing. 11) ON/OFF/Trip indication Light as per outgoing. 12) Spring Charge Healthy Indication as per outgoing. 13) Trip Circuit Healthy Indication as per outgoing. 14) Push Button Test Accept and Reset as per outgoing. 15) Breaker Control Switch as per outgoing. 16) L/R Switch as per outgoing. 17) Emergency Push Button as per outgoing. 18) 10-Annunciator as per outgoing 19) Pin Plug. 20) Toggle Switch. 21) Hooter. 22) Door Switch as per outgoing. 23) Space Heater with thermostat. 24) Control MCB as per outgoing. 25) LED as per outgoing 26) 32 Amp. X 3 Nos., 16 Amp. X 3 Nos. TP MCB for lightening load. For 5000 LPM X 25 Mtr Head (1 working plus 1 standby) |
| 25 | HT Panel -Supply Indoor Type 11KV VCB Control Cubical Panel with vertical Isolation Type Breaker as per Relevant IS as amended up to Date and Additional Specifications, having Capacities as Mentioned Below, Single break trip free mechanism, manually charged and Auto/ Manually closing breaker suitable for use on 11kv, 3 phase 50hz AC, Supply with short circuit fault level of 500 Amps Capacity, breaker featured with local ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 2NO plus 2NC and equipped with following switchgears and accessories including making suitable structure (such as G.O switch, H Pole and HT cable of required capacity etc. complete in all respect) arrangement for installation, control wiring and connections etc. as reqd. (1 IC plus 2 OG) a). VCB, 11KV, 630Amp, 50KA. b). 1ph 11KV/110 Volts PT (indoor type) Class 0.2 Accuracy and 100 VA burden -3 no’s. c). 33KV indoor dead type dual core dual ratio 3CTs of ratio 200-100/5-5 A of 15 VA burden, PS 5 P10 and accuracy class 0.2. d). Control panel- Cubicle type control panel suitable for floor mounting made out of 1.63 mm CR sheet duly powder coated and with following relays. e). Microprocessor based numerical relay for O/L, E/F and SC Protection suitable for above. f). Master trip relay -2 no’s. g). Indicator type Annunciator panel with buzzer. h). Digital Volt Meter- 0-11 KV. i). Digital Amp Meter- 0-100 Amp. j). RYB/ Trip/Closing/Spring charged indicator lamp. k). Fault Annunciator panel for O/L, WTI, OTI and Buchhloz Relay Alarm And Trip Auxiliary relay. l) TNC Switch for Operation. m) Multifunction Meter EM6400NG. n) TCS Relay for Safety.For IPS Railway Track |
| 26 | LT panel board indoor Type 0.415 KV ACB Control Cubical Panel with vertical Isolation Type Breaker as per relevant IS as amended up to date and Additional Specifications, having Capacities as mentioned below, Single break trip free mechanism, manually charged and Auto/Manuelly closing breaker suitable for use on 0.415 kv, 3 phase 50 hz AC Supply with short circuit fault level of 500 Amps Capacity, breaker featured with local ON/OFF Indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 2NO plus 2NC and equipped with following switchgears and accessories including making suitable structure arrangement for installation, control wiring and connections etc. as required (3 incoming and 7 outgoing) including provision of APFC Panel of 250 kVAR or as per suitable capacity. 1) ACB, 0.415 kV, 1600 Amp., 50 kA- 02 Nos. 2) Changeover Switch 0.415 kV, 1000 Amp., 50 kA- 01 Nos. 3) MCCB, 415V, 4 pole, 50 KA a) 800 Amp. -1 No. b) 630 Amp. - 1 Nos. c) 400 Amp. - 4 Nos. (1 No. outgoing for APFC panel) 4) Control panel- Cubicle type control panel suitable for floor mounting made out of 2 mm CR sheet duly powder coated and with following electrical equipment`s. 5) ELECTRONIC OVERLOAD RELAY WITH CT- 06 Nos. 6) AUXILARY CONTACTOR a) 265 A (2 NO plus 2 NC) COIL Voltage 220V-03 Nos. b) 265 A (2 NO plus 2 NC) COIL Voltage 220V-03 Nos. c) 225 A (2 NO plus 2 NC) COIL Voltage 220V-03 Nos. 7) Timers for starters- 06 Nos. 8) ELCB (96X96 mm) For all starters- 06 Nos. 9) AIR COOLED AUTO TRANSFORMER STARTER- 02 Nos. a) Frequency of Open. 6 starts/hour (evenly spaced) or as per specification. b) Starting time: Suitable for 12sec starting or as per specification. c) Taps: 50% /65% /80% or as per standard. d) Thermal cut-off: in-built. 10) RYB Indication Light as per outgoing. 11) ON/OFF/Trip indication Light as per outgoing. 12) Spring Charge Healthy Indication as per outgoing. 13) Trip Circuit Healthy Indication as per outgoing. 14) Push Button Test Accept and Reset as per outgoing. 15) Breaker Control Switch as per outgoing. 16) L/R Switch as per outgoing. 17) Emergency Push Button as per outgoing. 18) 10-Annunciator as per outgoing 19) Pin Plug. 20) Toggle Switch. 21) Hooter. 22) Door Switch as per outgoing. 23) Space Heater with Thermostat. 24) Control MCB as per outgoing. 25) LED as per outgoing 26) 32 Amp. X 3 Nos., 16 Amp. X 3 Nos. TP MCB for lightening load.For 8500 LPM X 40 Mtr Head (2 working plus 1 standby) |
| 27 | Providing and fixing of EOT Crane of Capacity 5 MT including providing and fixing vertical Column and horizontal beam made from suitable size of MS girders to be installed, Confirms to IS : 3177-807, Class of Duty: 2nd Heavy Duty, Lifting Height: 15 Mtr., Location : outdoor Type, Speed : Hoisting - 3 Mtr / Min. (up and down Motion), Cross Travel – 15 Mtr / Min, Long Travel – 15 Mtr / Min, with 5 MT motorized hoist / chain pulley block. complete in all respect as per design, as per direction and satisfaction of Engineer -in- charge Capacity 5 ton |
| 28 | Operation and Maintenance (OandM) of the entire storm water disposal system, including the existing PHED storm water infrastructure as well as the newly proposed works and all other works contingent thereto. The scope shall cover all civil, electrical, mechanical installations, storm water drains, intermediate pumping stations (IPS), main pumping stations (MPS), rising mains, and all associated structures up to the final disposal point, complete scope of work under this contract as per Operation and maintenance Manual of NIT (Attached in additional Documents) for a period of 5 years after 12 month defect liability period and 3 months trial run period. (charged to A/Mtc estimate year wise). Operation and maintenance during defect liability period (Operation only) after 3 months trial run period |
| 29 | Operation and maintenance for 1st Year after defect liability period and after 3 months trial run period. |
| 30 | Operation and maintenance for 2nd Year |
| 31 | Operation and maintenance for 3rd Year |
| 32 | Operation and maintenance for 4th Year |
| 33 | Operation and maintenance for 5th Year |
| 34 | Operation and Maintenance (OandM) of the entire Existing storm water disposals,Storm water Drains of PHED, and other related infrastructure and all other works contingent thereto. The scope shall cover all civil, electrical, mechanical installations, storm water drains, intermediate pumping stations (IPS), main pumping stations (MPS), and their rising mains, and all associated structures up to the final disposal point, complete in all respect during the construction Period as per Operation and maintenance Manual of NIT (Attached in additional Documents) for a period of 12 month . (charged to A/Mtc estimate year wise). Operation and maintenance during Construction period |
| 35 | HSR Itmes(As per uploaded DNIT) Please Enable Macros to View BoQ information |