| 1 | Excavation in foundation, trenches etc. in all kinds of soil such as pick work jumper work, blasting work in soft/hard rock, chiselling in soft/hard rock including wedging out upto all lift, stacking the excavated soil upto all lead clear from the edge of excavation and then returning the stacked soil in 15cm layers when requaired into plinths, sides of foundation etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as per direction and to the entire satisfaction of Engineer-in-Charge upto all lead and lifts. |
| 2 | Providing and laying cement conrete 1 : 4 : 8 . ( 1 cement : 4 sand and : 8 grade stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth upto all leads and lifts as per the direction and to the entire satisfaction of Engineer-in-Charge. |
| 3 | Providing and laying cement concrete 1 : 1½ : 3 mix. ( 1 cement : 1½ : sand : 3 graded stone aggregate 20mm nominal size) and curing complete excluding cost of form work and reinfocement for reinforced concrete work in : |
| 4 | Foundation footings bases of columns and the like; and mass concreteas per direction and to the entire satisfaction of Engineer-in-Charge. |
| 5 | Walls any thickness but not less than 0.1m thickness including attached pillaster buttresses, plinth and string courses from top of foundation upto two level all floor level as per direction and to the entire satisfaction of Engineer-in-Charge. |
| 6 | Suspended floor roofs, landing, shelves and their supports balconies beams, girders, bressumers and cantilevers upto two level all floor level in all leads and lifts as per direction and to the entiresatisfaction of Engineer-in-charge. |
| 7 | Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm so as to give a fair finish including centring, shuttering strutting and propping etc. with wooden batten and ballies, in all heights of propping and centring below supporting floor to ceiling not exceeding 4 mtrs and removal of the same for insitu-reinforced concrete and plain concrete work in :- |
| 8 | Vertical surfaces such as wall (any thickness) partitions and the like including attached pillasters, buttresses plinth and string courses and the like in all leads and lifts as per direction and to the entire satisfaction of Engineer-in-charge. |
| 9 | In flat surfaces with steel plates such as soffits of suspended floors, roofs, landing and the like floor etc upto all thickness in all leads and lifts as per direction and to the entire satisfaction of Engineer-in-charge. |
| 10 | Providing Tor steel reinforcement for RCC work I/c bending ,binding and placing in position complete upto floor two level. as per direction and to the entire satisfaction of Engineer-in-charge. |
| 11 | Providing in RCC work smooth finishing of the exposed surface with cement mortor1:3 (1cement :3 sand ) |
| 12 | Providing and fixing steel fibre reinforced concrete (SFRC) Manhole covers and frame confirming to IS : 12592 (part-I) 1988 with latest ammendments extra heavy, circular 560mm dia meter as per direction and to the entire satisfaction of Engineer-in-Charge. |
| 13 | Providing and laying cement concrete work 1:5:10( 1 cement :5 sand :10 graded stone agg. 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth. Please Enable Macros to View BoQ information |