Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift upto 1.5 m.) by Mechanical Means. |
| 2 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift from 1.5 m to 3.0 m) by Mechanical Means.. |
| 3 | Excavation for foundation in hard murum including removing the excavated material necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift upto 1.50 m) by Mechanical Means.. |
| 4 | Excavation for foundation in hard murum including removing the excavated material necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift from 1.5 to 3.0 m) by Mechanical Means. |
| 5 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres and necessary back filling with available earth /murum, ramming, watering including shoring and strutting, dewatering etc. complete (lift upto 1.5 m) by Mechanical Means. |
| 6 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres and necessary back filling with available earth /murum, ramming, watering including shoring and strutting, dewatering etc. complete (Lift from 1.5 m To 3.0 m.) by Mechanical Means. |
| 7 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. B. Spec. No As director by engineer incharge. |
| 8 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper.. Spec. No As director by engineer incharge. |
| 9 | Providing dry trap rubble stone soling 15cm to 20cm thick including hand packing and compacting complete. |
| 10 | Filling in plinth and floors with approved excavated material in 15cm.to 20cm. layers including watering and compacting etc. complete. Spec. No Bd.A.10 Page No. 262 |
| 11 | Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Spec. No. Bd.A 11, Page No. 263 |
| 12 | Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)) Spec. No. Bd.E.1 Page No. 287 Ground Floor |
| 13 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). Spec. No. Bd. F.3 Page No. 298 and B.7, Page No. 38 |
| 14 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). Spec. No. Bd.F.5 Page No. 300 And B7, Page No 38. Ground Floor |
| 15 | First Floor |
| 16 | . Second floor |
| 17 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No. Bd.F.6 Page No. 300 and B.7, Page No.38 Ground Floor |
| 18 | First Floor |
| 19 | Second floor |
| 20 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). Spec. No. Bd.F.8 Page No. 302 and B.7, Page No.38 Ground Floor |
| 21 | First Floor |
| 22 | Second floor |
| 23 | Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). Spec. No. Bd.F.9 Page No. 303 and B.9, Page No.38 |
| 24 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). Spec. No. : Bd.F. 13 Page No. 305. /I.S. 456 (2000) Ground floor |
| 25 | First floor |
| 26 | Second floor |
| 27 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). Spec. No. Bd.F.11 Page No. 304 and B.7, Page No. 38 Ground floor |
| 28 | First floor |
| 29 | Second floor |
| 30 | Providing and laying Cast in situ/ Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. Coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, laying/ pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Ground floor |
| 31 | First floor |
| 32 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.. Spec. No. Bd.F.17 Page No. 306 Ground floor |
| 33 | First floor |
| 34 | Second floor |
| 35 | Providing fly ash brick masonary with conventional / I.S. type fly ash bricks in cement mortar 1:6 in foundation and plinth including bailing out water manually, striking joints, racking out joints, watering and scaffolding complete. |
| 36 | Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete |
| 37 | Providing and laying in situ M-20 cement concrete of trap / granite / quartzite / gneiss metal with 15% plum of trap stones for foundation and bedding of retaining walls and jetty etc. including necessary formwork, compacting, curing, bailing out water manually in tidal range etc. complete. |
| 38 | Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part3)-1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Ground floor |
| 39 | First floor |
| 40 | Second floor |
| 41 | Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) |
| 42 | Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete/ B.B.masonry and or tying by binding wire etc. complete. |
| 43 | Providing internal cement plaster 12mm thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complet. Spec. No. Bd.L. 2 Page No. 368 Ground floor |
| 44 | First floor |
| 45 | Second floor |
| 46 | Providing and applying gypsum plaster (with Gypsum material of Gypsum India/ Mega Sign or equivalent make) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface/ or on newly brick surface (Excluding rough cast plaster) in all position including preparing and finishing the surface scaffolding etc. complete. Ground floor |
| 47 | First floor |
| 48 | Second floor |
| 49 | Providing and applying plaster with plaster of paris in 6mm. thickness to previously plastered surface in all position including preparing the surface scaffolding etc. complete. Ground floor |
| 50 | First floor |
| 51 | Second floor |
| 52 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Ground floor |
| 53 | First floor |
| 54 | Second floor |
| 55 | Providing and applying Two coats of wall care Putty of 2 mm. thickness for plastered surface and 5-6 mm. thickness finished concrete surface to Ceiling and Walls to prepare surface even and smooth of Brands BIRLA WHITE, BERGER, BISION, J.K., make, etc. complete for plastered walls/ ceiling 2 mm. Ground floor |
| 56 | First floor |
| 57 | Second floor |
| 58 | Providing and laying in position flooring of telephone black / Amba White / Cat Bary Brown / Ruby Red / Ocean Brown Granite Stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. Spec. No. Bd.M. 3 B/Page Number 380 Ground floor |
| 59 | First floor |
| 60 | Providing and applying Royale Luxury Emulsion of Asian/ Berger/ Nerolac/ Dulux Paints or equivalent make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area. Applying Asian/ Berger/ Nerolac/ Dulux Paints or equivalent wall primer with brush by adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dry for 6 to 8 hoursAfter applying Asian/ Berger/ Nerolac/ Dulux Paints or equivalent acrylic wall putty with appropriate prpportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45 % or 65 to 70 % by roller (With prior approval of S.E.). Ground floor |
| 61 | First floor |
| 62 | Second floor |
| 63 | Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC?s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Ground floor |
| 64 | First floor |
| 65 | Second floor |
| 66 | Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compoundand laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1 Kg per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. Spec. No As director by engineer incharge. |
| 67 | Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12 mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1kg/ per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 kg/bag of cement grouting and finishing the top layer with 20 mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 kg/ per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. Ground floor |
| 68 | First floor |
| 69 | Providing and laying 18 milimetre thick ADONI BROWN LEATHER FINISH stone for flooring, machine cut in required size, approved shade, color and texture laid using white cement slurry over 20 milimetre (average) thick base of cement mortar 1:4 followed by laying, fixing and jointed with white cement slurry mixed with matching pigment, including rubbing and curing moulding and polishing to edge to give high gloss finish etc complete. The application rate for tile adhesives shall be as per manufacturer's reco milimetre endations. as per detail drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels and as directed by Engineer in charge. Complete.a) Flooring |
| 70 | Providing and fixing machine cut machine polished 18 to 20 mm thick telephone black / amba white / cat bary brown / RBI red / ocean brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.. Spec. No .Bd. M.22 B Page No. 390 Ground floor |
| 71 | First floor |
| 72 | Second floor |
| 73 | Providing and fixing machine cut both side mirror polished 18 mm. to 20 mm. thick telephone black granite/ Amba White/ Cat bary brown/ Ruby Red/ Ocean Brown granite stone partition with rounding the edges etc. complete. Ground floor |
| 74 | First floor |
| 75 | Providing and laying telephone black / amba white / cadburybrown / ruby red / Ocean brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. Spec. No As director by engineer incharge. Ground floor |
| 76 | First floor |
| 77 | Providing and laying vitrified matt fininsh tiles for flooring having size 590 mm to 605 mm x to 605 mm. of 8 to 10 mm. thickness and confirming I.S. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. Ground floor |
| 78 | First floor |
| 79 | Providing and laying vitrified matt finish tiles for Skirting having size 590 mm. to 605 mm. x to 605 mm. of 8 to 10 mm thickness and confirming I.S. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. Ground floor |
| 80 | First floor |
| 81 | Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete |
| 82 | Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm. x 30 cm. and conforming to I.S.15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. Ground floor |
| 83 | First floor |
| 84 | Providing and fixing frame with / without ventilator of size as specified with country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete. Spec. No As director by engineer incharge. Ground floor |
| 85 | First floor |
| 86 | Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.. Spec. No. BD-T-34 Page Number 499 Ground floor |
| 87 | First floor |
| 88 | Providing and fixing solid core flush door shutter in double leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. Spec. No. As directed by Engineer in charge. |
| 89 | Providing and fixing fibre glass reinforced polyster door shutter 35 mm. thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc. complete. Ground floor |
| 90 | First floor |
| 91 | Providing and fixing in position mild steel fixed staggered (Z Type) Ventilator as per detailed drawing woth hot deep zinc coating including fabricating with mild steel \\"Z Section\\" of size 20 mm x 25 mm. and 3 mm. thick at weight 1.42 Kg/Rmt., with stainless steel mosquito net of 304 Grade, 4 mm. thick float glass as directed by Engineer Incharge including necessary welding, grinding and two coats of oil paint etc. complete. Ground floor |
| 92 | First floor |
| 93 | Providing and fixing mild steel grill work for windows, ventilators, etc.15 kg/sq.m as per drawing including fixtures, necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete. Ground floor |
| 94 | First floor |
| 95 | Providing and fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex. Engineer is necessary before use). Spec. No As director by engineer incharge. Ground floor |
| 96 | First floor |
| 97 | Second floor |
| 98 | Providing and fixing white european type wall-hung pan, of size 350mm x 355mm x 570 mm concealed flush tank with floor-mounting frame installing kit and drain pipe connection set for wall hung WC, with approved make square control plates including soil pipe, vent pipe upto the outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc. complete. Ground Floor |
| 99 | First Floor |
| 100 | Providing & fixing ORISSA TYPE colour glazed earthen ware 625 x 450 mm. W.C. Pan including trap, C.I. soil & vent pipe upto the out side face of wall including 100 mm. diameter C.I.plug, bend,15mm. thick 10 litre PVC flushing cistern with all necessary pipe connection etc. complete. Ground Floor |
| 101 | First Floor |
| 102 | Providing and Fixing toilet set for differently Abled persons consist of Floor Mounted white vitreous china water Closet including 6 litre capacity white vitreous china flushing Cistern with raised soft-push button, white vitreous china wash basin of size 46 x 36 cm and one no SS 304 hinged rail 76 cms & three no SS 304of (Grab Bar) 60 cms all including cutting and making good the walls and floors wherever required ,seat cover, cistern & wash basin fittings,nuts, bolts and gasket etc complete of make Hindware(Matrix series 70002)/ Cera or equivalent as per the direction of Engineer-In-charge. |
| 103 | Providing and fixing white glazed urinal of series with Pressmatic auto closing valve of having 32 milimetre diameter P.V.C. flush pipe with fitting and flushing of approved make and arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc.complete as directed by Engineer in charge. Ground floor |
| 104 | First floor |
| 105 | Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195mm size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 mm thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge.... Spec. No. As directed by Engineer in charge Ground floor |
| 106 | First floor |
| 107 | Providing and fixing 450 mm x 550 mm size superior type belgium mirror with 16mm dia. nickel plated towel rod etc. complete. Spec. No As director by engineer incharge. Ground floor |
| 108 | First floor |
| 109 | Providing and fixing 10 centimeter PVC nahani trap with grating etc. complete. Ground Floor |
| 110 | First Floor |
| 111 | Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. Spec. No. Bd.V.38 Page No.572. |
| 112 | Providing and fixing Shower Head with shower arm of approved make shower tube hand shower with divertor of spout including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge. Ground Floor |
| 113 | First Floor |
| 114 | Providing and fixing C.P.Two way BIB cock of approved make continental including necessary sockets/union nut etc. complete. Spec. No As director by engineer incharge. Ground floor |
| 115 | First floor |
| 116 | Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. Spec. No As director by engineer incharge. Ground floor |
| 117 | First floor |
| 118 | Providing and fixing on walls / ceiling / floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge. |
| 119 | Providing and fixing on walls / ceiling / floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge |
| 120 | Providing and fixing on walls / ceiling / floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge |
| 121 | Providing and fixing on walls / ceiling / floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge. |
| 122 | Providing and fixing on walls / ceiling / floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge. |
| 123 | RWH - Recharge PitProviding and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5\\" dia x 25m deep borewell at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrapped around with netlon mesh including 300mm thick sidefilling around outside of RCC rings (annular space) with 40mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end-caps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge. |
| 124 | Providing and laying in trenches 40 mm diameter medium grade having embossed as ISI Mark galvanised iron pipes of 3.68 Kg/metre with necessary fitting, remaking good the demolished portion with filling trenches and with primer of anti-corrosive primer oil paint two coats etc. complete. |
| 125 | Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Spec. No As director by engineer incharge. |
| 126 | Providing and fixing 100 mm diameter stabiliser pipe/ P.V.C. soil vent/ waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps etc. complete.. |
| 127 | Providing , laying and fixing ,jointing supreme eco- drain 160 mm SN 4 Nu- drain UPVC pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees, coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etc. complete. Spec. No As director by engineer incharge. |
| 128 | Providing , laying and fixing ,jointing supreme eco- drain 315 mm SN 4 Nu- drain UPVC pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees, coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete. Spec. No As director by engineer incharge. |
| 129 | PProviding and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. Spec. No As director by engineer incharge. |
| 130 | Supply and installation of cubicles of width and depth as perAthena Lite- SS Series Cubicles- Std Sizes (W x D x H): 900 mm x 1550 mm x 2105 mm, (Height is including 100 mm gap from bottom, Door Width- 600 mm specifications/ site drawings). Cubicle height to be 2105 mm. Made from solid grade compact high pressure laminate as per IS:2046 and EN-438 manufactured under high specific pressure > 5 MPa and temperature >120°C, All doors will be of single colour and made of 12 mm thick Merino HPL compact panel. The doors will have chamfered edges. Each door will be supported by 3 stainless steel made hinges affixed to the pilasters. Size of panels to be as per drawing. HARDWARE & ACCESSORIES are H shaped (Top) head frame structure made of extruded Aluminium grade 6063 T5-50 micron epoxy powder coated for surface protection, Size to be 125x70x5T. Corner joinery section, Size to be 40x16.5x1.8T. U-Channel Wall joinery section,Size to be 22x16x1.6T. Door stopper section, Size to be 21x12.5x1.6T. Spring loaded Butt Hinges made from Stainless steel grade 304. Surface finish to be matt type. Covers to be lacor coated.etc complete. |
| 131 | Providing and laying concrete pipes of I.S.NP. class of 150 mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complet. Spec. No. Bd.V.41 Page No.573. |
| 132 | Providing and laying concrete pipes of I. S. NP. class of 300 mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Spec. No. Bd.V.41 Page No.573. |
| 133 | Providing & constructing Brick Masonry Inspection Chamber 60 Cm x 45 Cm x 90 Cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. I. lid 65 kg with frame fixed in cement concrete etc. complete with R.C.C. Cover medium duty 140 kg with frame etc complete. Spec. No. Bd.V.43 Page No.574. |
| 134 | Providing & constructing Brick Masonry Inspection Chamber 90 cm x 45 cm x 90 cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed Stone Ware pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. cover medium duty 140 kilogram with frame etc. complete. |
| 135 | Providing and fixing High Density Polymer container Syntex or alike one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow pipe inclusive of all tanks capacity between 1000 to 20000 liters. |
| 136 | Providing and fixing hume pipe septic tank 900 mm diameter with vent pipe and cap including necessary (excluding excavation and laying). |
| 137 | Providing soak pit of size 120 cm x 120 cm x 120 cm including excavation and filling with brick bats. Spec. No. Bd.V.46 Page No.576. |
| 138 | Providing and fixing in position gypsum board false ceiling with 12.5mm thick gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. Spec :As directed by Engineer in charge. . Ground floor |
| 139 | First floor |
| 140 | Providing and fixing Modular false ceiling of 600 x 600 milimetre center to center and 13 milimetre thick square mineral fiber board to be fixed on frame work of alluminium sections for suspended false ceiling consisting of alluminium T 2”x1 ½” (50 milimetre x 40 milimetre) weighing 0.39 kilogram per metre at 60 centimetre center center and fixed with ½” x ½” (15 x 15 milimetre) flanges weighing 0.19 kilogram per metre suspended on 6 milimetre diameter mild steel rod weighing 0.22 kilogram per metre, fixed on wall and beams including rounding of the edges with alluinium T of 2” x 1 ½” (50 milimetre x 40 milimetre) weighing 0.39 kilogram per metre etc. (all alluminium sections shall be anodized) including all labour, material, lifts etc. complete. Ground floor |
| 141 | First floor |
| 142 | Providing and fixing 50 mm diameter and 1.5 mm thick Stainless steel hand railing in S.S.304 Grade including fabricating ,fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete Ground floor |
| 143 | First floor |
| 144 | Excavation for roadway in earth soil of all sorts, sand, gravel or soft murum including dressing section to the required grade camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 metre and spreading for embankment or stacking as directed. |
| 145 | Providing and laying concrete pipes of I.S.NP. class of 225 mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complet. Spec. No. Bd.V.41 Page No.573. |
| 146 | Providing earth work in embankment with approved materials obtained from other sources upto lead of 50m. including all lifts, laying in layers of 20cm. to 30cm. thickness breaking clods, dressing to the required lines, curves, grades & section, watering and compaction with vibratory roller with V-Sat attachment to achieve not less than 97 % of standard proctor density etc. complete ( Material obtained from Other sources) Spec. No. MORTH 305 |
| 147 | Construction of granular sub-base by Plant Mix Method by providing close graded Material,mixing in a mechanical mix plant at OMC,carriage of mixed Material to work site,spreading in uniform layers with Motor Grader/ Paver on prepared surface and compacting with vibratory power roller to achieve the desired density complete as per clause 401.For Grading I Material. |
| 148 | Wet Mix Macadam -- Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. Laying By Grader/Paver. |
| 149 | Providing and applying primer coat with bitumen emulsion on prepared surface of Granular Base including clearing of road surface and spraying primer at the rate of 0.60 kg/Square Metre using mechanical means. |
| 150 | Providing and applying tack coat on the prepared surface heating by flames in boiler and spraying bitumen with sprayer on dry/hungry B.T. surface at 3.00 Kg /10 Square Metre using VG-30 grade bulk bitumen. |
| 151 | Providing and laying Bituminious Macadam using crushed aggregate of Grading 1, premixed with bituminious binder, transported at site with VTS, laid over a previously prepared surface, finished to the required grade, level, alignment and rolling to achieve the desired density for 80/100 mm compacted thickness with Drum Mix type hot mix plant with SCADA, having complying essential features of hot mix plant as per IRC-27:2009 specified conditions and attachments such as electronic load sensor based belt conveyers, automatic synchronization of bitumen and aggregate fedder, built in dust controller system and PLC for Drum Mix plant, Sensor Paver and Vibratory Roller excluding prime/Tack coat etc. complete with VG-30 grade Bitumen of dose 3.30 percent. |
| 152 | BITUMINOUS CONCRETE:- Providing and laying semi dense bituminous concrete using crushed aggregate of grading 1, premixed with bituminous binder @5.40% by weight of total mix and filler, transported at site with VTS, laid over a previously prepared surface, finished to the required grade ,level, alignment, and rolling to achieve the desired density for 50mm compacted thickness with drum mix plant with SCADA, Sensor paver and Vibratory roller excluding prime/Tack coat etc. complete --Bitumen of specified grade with stone dust filler. (VG-30 bulk bitumen rates are considered to arrive at rates) |
| 153 | Providing and erecting chain link fencing 1.6 M. height with G.I. chain link of size 50 x 50 mm, 8 gauge thick and fixed 75 mm above ground level on vertical M.S. Angles of 40 x 40 x 6 mm size, includind excavating pits for foundation and embedded in C.C. block of 1:4:8 mix of size 450 x 450 x 670 mm. at 1.75 M. c/c with iron bar 16mm dia as hold fast including welding link with angle frame at 30 cm c/c with nuts and bolts and horizontal M.S. Angles at top and bottom of 25 x 25 x 5 mm size and vertical M.S. flat 35 x 5 mm and 25 x 5 mm horizontal including cross support of 40 x 40 x 6 mm angles both side at every corner or bend embedded in concrete blocks of 1:4:8 of size 450 x 450 x 670 mm including 3 coats of oil painting etc. complete. |
| 154 | Providing and casting in Situ or precast tapering R. C. C. M20 mountable type Kerb without gutter (as per IRC 86 1983) embedded 125mm below ground level over M10 PCC finished neatly with C.M. 1:2, setting the same in C.M. 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering Incharge. Using Concrete Batching and Mixing Plant Spec. No. MORTH 408 |
| 155 | Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 450mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. Spec. No. CD.7 Page.Number 162. |
| 156 | Providing and laying in trenches 50mm dai. uPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.complete. |
| 157 | Providing and fixing screw down 40 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. Spec. No. Bd.V.9 Page One Number 555 |
| 158 | Providing & laying perforated P.V.C. 160 mm diameter pipe in proper line,level and slope including necessary material fitting etc complete. |
| 159 | Providing and laying in situ cement concrete M-20 with tremix treatment for 100 mm. thickness for flooring with groove cutting of 4 mm. wide and 20 mm. deep with necessary refilling with bitumen etc. complete. |
| 160 | Providing and fixing 15 mm diameter PVC Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etc complete Ground Floor |
| 161 | First Floor |
| 162 | Providing and fixing Multiple Compartment Lockers @ 1140Lx 457D x 1830 mm. Ht. with 12 Compartments , Complete body & shutter made of CRCA Sheet with powder coated finish as per approved color. |
| 163 | Providing and fixing on walls / ceiling / floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge. |
| 164 | Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:3 with neeru finish to concrete surface complete. |
| 165 | Providing internal cement plaster 20 mm. thick in two coats in cement mortar 1:5 with neeru finish, to concrete, brick surface, in all positions including scaffolding & curing complete. |
| 166 | Providing and applying, plastic emulsion paint of approved quality, colour and shade to old and new surface in three coats including scaffolding, preparing the surface.(excluding primer coat). complete. |
| 167 | Providing and fixing in position (as per I.S.1868: 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 mm. at weight 0.547 kg/Rmt. and window frame bottom track section 61.85 x 31.75 x 1.20 mm. at weight 0.695 kg/Rmt. Top and side track section 61.85 x 31.75 x 1.30 mm. at weight 0.659 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm. at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm. at weight 0.469 kg/Rmt. And handle section 40 x 18 x 1.25 mm. at weight 0.417 kg/Rmt. and top section 40 x 18 x 1.25 mm. at weight 0.417 kg/Rmt. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm. thick plain glass with all required screws and nuts etc, complete with colour Anodising without box. |
| 168 | Providing and fixing white european type wall-hung, of size 360 milimetre x 360 milimetre x 575 milimetre with flush valve of approved make including soil pipe, vent pipe upto outside face of wall, 100 milimetre dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc as directed by Engineer in charge. |
| 169 | Providing and fixing Orissa type white glazed earthenware 575 mm water closet pan including 'S' trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etc.complete. |
| 170 | Providing and fixing on walls /ceiling/ floor 40 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete. |
| 171 | Providing, laying & fixing P.V.C. pipe of 50 mm. diameter with fittings such as bends, tees, reducers, clamps etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 172 | Providing, laying & fixing P.V.C. pipe of 75 mm. diameter with fittings such as bends, tees, reducers, clamps etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 173 | Providing, laying & fixing P.V.C. pipe of 110 mm. diameter with fittings such as bends, tees, reducers, clamps etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 174 | Providing and fixing on walls/ ceiling/ floors, 100 milimetre diameter heavy grade having embossed as Indian Standard Institute Mark galvanised iron pipes of 14.74 kilogrames per metre with necessary fitting, remaking good the demolished portion and applying primer of anti-corrosive oil paint in 2 coats complete. |
| 175 | Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. I. cover of 75 Kilogram with lid and frame fixed in cement concrete etc complete... Spec. No. Bd.V.43 Page No.574. |
| 176 | Providing and fixing reinforced cement concrete Heavy duty (225 Kg) cover of size 90 centimeter x 45 centimeter with frame over inspection chamber etc. complete. |
| 177 | Providing and fixing reinforced cement concrete Heavy duty (160 Kg) cover of size 60centimeter x 45centimeter with frame over inspection chamber etc. complete. |
| 178 | Providing and laying in place 300mm x 300mm x 16mm cement tactile directional and warning tiles (for a person with visual impairment)of the approved brand and make and specified colour for outdoor floors such as footpath, courtyard, multimodals location etc. laid on 20mm thick base of cement mortar 1:4 (1 cement: 4 coarse sand) in all shapes and patterns including grouting the joints with white cement with matching pigments etc. complete as per direction of engineer in charge |
| 179 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means Grading-I (Using Screening Type B (11.2 mm) Aggregate) |
| 180 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means - Grading II (Using Screening Type B (11.2 mm) Aggregate) |
| 181 | Providing and constructing 75 mm. thick Modified Penetration Macadam (MPM) road surface including all materials, preparing the existing road surface, spreading 40 mm. stone metal layers 100% crusher broken metal with conical crusher plant, heating and spraying the bitumen of VG-30 grade @ 2 Kg/sqm, spreading 12 mm. size chips compacting with three wheel static roller having weight 8 to 10 MT. to achive the desired degree of compaction as per Technical Specification Clause 506 etc. complete including picking of existing WBM surface. |
| 182 | Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete. Spec. Number : As directed by Engineer-in-charge. Spec. No. As directed by Engineer-In- Char |
| 183 | Providing and laying of hot applied thermoplastic compound 2.50 milimetre thick including reflectorizing glass beads at 250 grams per square metre area, thickness of 2.50 milimetre is exclusive of surface applied glass beads as per Indian Road Congress:35. The finished surface to be level, uniform and free from streaks and holes complete. |
| 184 | Providing and laying Cast in situ/ Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, plywood/ steel formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand V.S.I. Grade). |
| 185 | Providing and laying in situ/ Ready Mix cement concrete M-20 of trap/ granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, formwork, laying/ pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided, (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). |
| 186 | Providing and laying Cast in situ/ Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). |
| 187 | Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.Spec. No. Bd.C.2 Page No. 275 |
| 188 | Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. Spec. No As director by engineer incharge. |
| 189 | Providing and fixing on walls /ceiling/ floors, 15 mm diameter heavy grade having embossed as ISI Mark galvanised iron pipes of 1.48 Kg/metre with necessary fitting, remaking good the demolished portion and applying primer of anticorrosive oil paint in 2 coats etc.complete. |
| 190 | Providing and laying Cast in situ/ Ready Mix cement concrete in M-15 of trap/ granite/ quartzite/ gneiss metal for steps including steel centering, plywood/steel formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand V.S.I. Grade). |
| 191 | Providing and fixing 20 to 25 milimetre thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimetre thick Cement mortar 1:3 with conceal, setcrete (RMW), Algaeproof or other alike water proofing liquids, raking of joints upto 35 milimetre depth,filling the joints with 6 milimetre size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete). |
| 192 | Providing and fixing 20 to 25 milimetre thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 milimetre between rough shahabad and Reinforced Cement concrete walls with cement grout mixed with water proofing liquid Algaeproof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 milimetre and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrtete 1:3:6 base concrete). |
| 193 | Providing and laying jointless Polydee-LM jointless a highly flexible elastometric coating for RCC/ cementitious surface for terrace waterproofing on B.B.Coba/ R.C.C, after application of TP-42 Primer on perfectly clean substrate (free from loose dust and foreign matter), application of 1st coat of Polydee-LM at the rate 700 gms/sqm applying second coat of Polydee-LM at the rate 700 gm/sqm and finishing the same with sprinkling the AG-10 granules on the wet coating. (After finishing covering the treatment with 25 mm cement plaster for protection with fibrillated 6 mm Plyplast fibre at the rate 125 gms per sqm (to be paid in separate item.) covering 7 years guarantee on Court Fee Stamp Paper of Rs.100/- etc. complete. |
| 194 | Providing waterproof plaster in W.C. and bath 20 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 kg. per bag of cement of approved make and manufacturer and curing and filling joints of Nahani trap and any outlet by properly etc. complete. |
| 195 | Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. Spec. No. As directed by Engineer in charge. |
| 196 | Providing and applying Bitumen VG30/ VG40 layer at 2 kg. per square meter over the terrace, structural slab including cleaning the surface for waterproofing as directed complete. |
| 197 | Providing leak proof treatment by injection grouting method to old floor without removing tiles of W. C., bath, with cement sand proportion of 1:1.5 and water proofing compound at 2 Kg/bag of cement mixed in 35 litres of water including drilling holes in required position groutingwith above mixed solution and ceiling etc. complete. |
| 198 | Providing and laying Vitrified MATT finish having decorative type of size 1000 millimeter x 1000 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical and confirming to I.S. 15622-2006 (Group Bla) of approved make shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints curing and cleaning etc. complete. |
| 199 | Providing and fixing 40mm diameter and 1.5 mm thick Stainless steel hand railing in S.S.304 Grade including fabricating ,fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete. Spec. No As director by engineer incharge. |
| 200 | DENSE BITUMINOUS MACADAM: Proving and laying dense bituminous macadam using crushed aggregates of Grading 1, premixed with bituminous binder of specified grade of Bitumen @ 4.50 per cent by weight of total mix and filler, transported to site with VTS , laid over a previously prepared surface, finished to the required grade, level, alignment, and rolling to achieve the desired density for 76-100 mm compacted thickness .USING Batch mix type hot mix plant with SCADA, Sensor Paver, Vibratory roller with Stone Dust filler.(VG-30 bulk bitumen rates are considered to arrive at rates) |
| 201 | Providing and laying bituminous concrete using crushed aggregates of Grading-1, premixed with bituminous binder at 5.20 percent by weight of total mix and filler, transported to site with Vehicle Tracking System, laid over a previously prepared surface, finished to the required grade, level, alignment and rolling to achieve the desired compaction for 50 mm compacted thickness with VG-30 Bitumen, excluding prime/ tack coat. Using Batch mix type hot mix plant with SCADA, Sensor Paver, Vibratory Roller with Stone Dust filler. |
| 202 | Providing and casting in situ or precast tapering R.C.C. M-20 Barrier type Kerb without gutter (as per IRC:86-1983) embedded 125 mm below ground level over M-10 P.C.C. finished neatly with C.M. 1:2, setting the same in C.M. 1:2, including the required excavation in any strata and removing the excavated stuff anywhere in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching and Mixing Plant. |
| 203 | Providing and fixing heavy duty inter locking concrete Gray paving blocks of 80 mm. thickness of having a strength of 300 kg/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm. thick including skirting joints and cleaning etc. complete. |
| 204 | Providing and fixing heavy duty inter locking concrete Gray paving blocks of 60 mm. thickness of having a strength of 300 kg/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm. thick including skirting joints and cleaning etc. complete. |
| 205 | Providing and laying Cast in situ/ Ready Mix cement concrete M-15 of trap/ granite/ quartzite/ gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed). With fine aggregate (Crushed sand V.S.I. Grade). |
| 206 | Providing and applying two coats of exterior white weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning, prepairing the plaster surface, applying primer coat, scaffolding if necessary and watering the surface for two days complete. |
| 207 | Providing and laying Dense Bituminious Macadam using crushed aggregate of grading 1, premixed with bituminious binder, @4.50% by weight of total mix and filler, transported at site with VTS, laid over a previously prepared surface, finished to the required grade, level, alignment and rolling to achieve the desired density for 76/100 mm compacted thickness with Drum Mix type hot mix plant with SCADA, having complying essential features of hot mix plant as per IRC-27:2009 specified conditions and attachments such as electronic load sensor based belt conveyers, automatic synchronization of bitumen and aggregate fedder, built in dust controller system and PLC for Drum Mix plant, Sensor Paver and Vibratory Roller excluding prime/Tack coat etc. complete with Bitumen VG-30 grade with stone dust filler. |
| 208 | Providing & applying washable oil bound distemper of approved colour and shade to old & new surfaces in two coats including scaffolding, preparing the surfaces.(excluding the primer coat.) complete. Ground floor |
| 209 | First floor |
| 210 | Second floor |
| 211 | Providing and applying priming coat on concrete/ masonary / asbestos cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. Spec. No As director by engineer incharge. Ground floor |
| 212 | First floor |
| 213 | Second floor |
| 214 | Providing and fixing mild steel grill work for windows, ventilators 20 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. |
| 215 | Labour charges for removing grass, thorney shrubs, Jungli shrub, Kubabul and alike grass along roadside making the ground clean by showel and phavaras etc. complete. |
| 216 | Three Track Two Glass+ One Net Shutter Window :Providing and fixing aluminium system color anodized sliding window of various sizes. Window will be made from Geeta / Malwin/Lexil/Brandson, 25 to 27 mm slim series or equivalent System. Window will be of specially extruded aluminium 3Track-2 Glass+ 1 net shutter, track joints will be of 45 degree joints, Joints will be fixed with specially developed clits. Track frame will be fixed to the masonry opening of windows with S S 202 screws. Glass shutter will be made from specially extruded aluminium section, glass considered is 5 mm. clear toughened glass. All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to form uniform hairline joint. All shutter will be fixed to the main frame with necessary double roller to have smooth and easy movement of the shutter. Shutters will have single point self pressing lock. All fixing screws will be of S S 202. Windows will be sealed with weather sealant from outer periphery, etc. all complete as per architectural drawings and the directions of the engineers-in-charge with all necessary fasteners and accessories complete |
| 217 | Providing and fixing 12 mm thick toughen glass and edge polish as shown in the drawings or as directed, including all necessary fittings like Upper glazing profile, bottom locking glazing profile, standard gasket for profile, locking Gasket 12 mm,door soft central 180 weather seal for glass edges as pes drawings having glass fixing sections at all sides concealed in partitions etc complete as directed by Engineer -in-Charge gaps between glass panels should be filled by clear silicon weather proofing sealant, EPDM gaskets, handles all necessary fasteners and accessories complete as directed by Engineer-in-Charge |
| 218 | Tensile membrane structure - Main FabricDesigning, Supplying, Providing, fabricating, assembling and erection of Tensile membrane MS structure by Serge Ferran accredited category A fabricator using Precontraint TX30 of Serge Ferrari including associated civil work, foundation design, plates, foundation boits, gutter, flashing, gabel ends wherever required and complete structural design considering wind load & height of installation and providing structural stability certificate for the same from registered structural engineer in project area For details refer to Specifications. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, including all leads, lifts at all levels and shall De as directed by Engineer in charge. The rate shall be exclusive of Goods & Service Tax but inclusive of all other taxes, duties & levies |
| 219 | Providing and laying Filter material underneath pitching in slopes complete as per drawings and technical specifications etc. complete. |
| 220 | GARDEN SOIL:- Supplying on site garden soil well seived 80% to pass through I.S seive of 10 mm size free from stones rubbish like dried grass roots and other such materials.The soil should befresh from quarry. The colour of the soil generally is red. The soil will be measured by measuring box(Farma) Item includes Transporting loading-unloading etc ( Lead charges per 35km. considered Excluding royalty.) |
| 221 | Inspecting the existing asphalt sub base laying new synthetic surface of sandwich according to the latest version of IAAF hand book and its amendment and then design , plan, supply, deliver, store and install sandwitch type 400mm 8 lane mimimum 14 mm thick synthetic Athletic Track cast in situ with SBR rubber & EPDM granules of terracotta colour (including line marking on surface as per IAAF Standard)surface to surface to latest IAAF Handbook Specification and requirement within the tolerant limits set out by IAAF to obtain IAAF Class 2 certification for the completed athletic track with line marking by IAAF approved surveyor. IAAF approved brands of approved material all complete with the 5 years life Gurantee for the 400M synthetic sandwich type athletic track using operation and maintenance manual and training to PMC feilds staff for protection of synthetic track all complete and IAAF field manual norms whichever is most strigent.(IAAF approved Brands) Brands approved Spurtan BV- Polyton, Conica (Germany), Alstan SW (Stockmare), Poreplastic competition or any other brand of American, UK, EU, Australia which are IAAF Approved and having established office in India a. Base Layer : Polyurethane binder and SBR granules laid with the specialised paver b. Central Layer : Seal Coat using Polyurethane and EPDM Powdered Rubber c. Top Layer : Spray Coat of Polyurethane mixed with EPDM granules. |
| 222 | Providing and laying 50mm thick Multipurpose Heavy Duty Natural Turf for playfields and Football ground over the prepared surface including watering, cutting, trimming, levelling, etc. complete. Final density of turf will be achieved as required and to the entire satisfaction of the Architect/Engineer in charge (Bermuda Grass).Spec.as directed by engineer in charge. |
| 223 | Providing and fixing throwing safety cages with requied poles and net incl. the ground fixing sleeves and ground hooks etc. for discus and hammer throw of IAAF approved spec. As directed by Engineer in Charges (Including all necessary testing) etc. Complete. including all taxes and duties |
| 224 | Providing and fixing Hammer throwing circle / ring of IAAF approved spec. As directed by Engineer in Charges (Including all necessary testing) etc. Complete. including all taxes and duties |
| 225 | Providing and fixing discts throwing circle / ring of IAAF approved spec. As directed by Engineer in Charges. (Including all necessary testing) etc. Complete.all taxex and Duties. |
| 226 | Providing and fixing shot put throwing circle / ring of IAAF approved spec. As directed by Engineer in Charges. (Including all necessary testing) etc. Complete. including all taxes and duties |
| 227 | Providing and laying root zone.Providing and filling ground with sand of approved quality incl. watering, compacting, etc. complete. Spec. as directed by engineer in charge.H46 |
| 228 | Providing supplying and Fixing Of precast Reinforcement cementConcrete U Shaped drain Gutter Of graded M40 With heavy drainn Cover Of required Size 450X450mm including jointing fixingand maintaining required shap as per drawing and instructeion from engg-in-charge (incluing all texes excluding GST) |
| 229 | PROVIDING and laying Natural River Sand in Play Area or requiredlocations in Gardens,as per the instructions given by the EngineerIncharge, inclusive of material,Labour,Transportation,Taxes,etcall complete. |
| 230 | Providing & fixing ALUMINIUM DOUBLE DOOR WITH 6 MM TOUGHNED GLASS made up of 85*35mm mat silver colour anodised door sections for hinge side and lock side and 85*35 mm top section for top and 150*35 mm bottom section for bottom. 6 mm toughened glass is fitted with help of a silver anodised aluminum glazing clip and door is fitted using top bottom pivot and heavy duty floor spring door closer ( Enox. Quba or Hafle). Including PVC U packing for glass, SS 450 mm H handle and dead lock system and labour charges etc. as per architectural design and drawing and as directed by Engineer In charge etc. complete |
| 231 | Providing and Construction RCC InspectionChamber 90cm x 45cm x90cm with RCC M-20 raft of 200mm thick in all strata area including cost of reinforcement RCC M-20 vertical pardi of 150mm thick including cost of reinforcement, including steel centering, formwork, cover blocks, laying/pumping, compacting, curing, finshing and roughening them if special finish is to be provided and curing complete for RCC work, 1:2:4 cement concrete channels half round G.S.W. pipes, plastering from inside and airtight with 75mm thick RCC cover medium duty 140kg etc. complete. Rate including all leads and lifts at Pune station. (Including excavation in all strata. minimum 48.00kg of TMT Fe 500 steel, RCC minimum 0.77 Cum M-20 etc are included in cost. |
| 232 | Providing and Construction RCC InspectionChamber 60cm x 45cm x90cm with RCC M-20 raft of 200mm thick in all strata area including cost of reinforcement RCC M-20 vertical pardi of 150mm thick including cost of reinforcement, including steel centering, formwork, cover blocks, laying/pumping, compacting, curing, finshing and roughening them if special finish is to be provided and curing complete for RCC work, 1:2:4 cement concrete channels half round G.S.W. pipes, plastering from inside and airtight with 75mm thick RCC cover medium duty 140kg etc. complete. Rate including all leads and lifts at Pune station. (Including excavation in all strata. minimum 48.00kg of TMT Fe 500 steel, RCC minimum 0.77 Cum M-20 etc are included in cost. |
| 233 | All weather synthetic application : providing and applying five layer all weather synthetic coating for vollyball,basketball,tennis court over existing concrete or bitumen base.this includes cleaning existing surface,removing existing dust,dirt and repairing minor cracks and surface depressions using crack filler and then applying first layer of primer(uniqprimer) or filler chemical.then applying second and third layer of sealer or resurfacer (100% acrylic , concentrated and pigmented emulsion ) which includes repairing all cracks and surface depression using priroof crack filler and then applying sealer (black or natural white colour) using silica sand and potable water.after this applying fourth and fifth layer of synthetic color coating(100% acrylic , highly pigmented emulsion) using silica sand.colour coating will be green,red or bule in colour as per the instructions of site in charge.after all layers are applied, line marking shall be donewith width and measurements as per the international standards and instructions of site in charge.this work will include gurantee of atleast three years from the application of coat. |
| 234 | Providing & fixing factory-made safety fencing powder coated steel special connector, it includes 6 Mtr High with ladder back support up to 4.5m, ф 76mm (OD) 3 mm thick MS pipes, green powder coated factory finished post vertical post fixed on foundation with the help of J bolt Which supplied by us and fix by client as per our drawing. At 3.0mtr center to center distance, ф 60 mm (OD) 2 mm thick MS pipe Horizontal post, three horizontal post installed at Top middle and Bottom location for 6 mtr Height with the help of special connectors. Garware make 2” X 2” nylon Net to be used all sides of Fencing, fixed to vertical post and Three horizontal Supports with the help of 6mm thick nylon rope. special Connectors made from pressed steel and powder coated finish for connecting Vertical and horizontal post by using M12 X 90 carriage bolt at every joint and corner of horizontal and vertical post without welded joints for easy installation and removable. Entire material is sandblasted, Powder coating is done with high quality PP powder coating (Jotun PP powder) and finally tests such as scratch test, DP test (confirming coating thickness) and salt spray test are done to ensure quality check. Entire material comes with 2 years warranty on the coating. |
| 235 | Providing and Fixing Structural steel gate with Wire mesh of size 50 x 50 mm 4 gauge thick and fixed 75 mm above Ground level. outer vertical support of ISMC 150X75X10 mm size Channel for M.S. box 150X150 mm embedded in C.C. block of M25 garde of size 450 x 450 x 700 mm. at 1.75 M.c/c with iron bar 16. etc. complete & As per Drg & design. |
| 236 | Supplying, laying, fixing Multisport Artificial Turf 15mm thick in proper line, level including compaction, all laed, lift, labour, tarnsportation and material etc. complete Technical Specification - Product Name - Multisports 15mm , Application Multisports, Roll Width - 2 Mtr , Roll Length - 25 Mtr, Colour - 2 Tone YRAN Structure:Curl Composition(FIFA Test method 22) – PE, Dtex(FIFA Test method 23) - 5500 ±10%, Tape thickness(FIFA Test Method 25) - 0.67-0.75mm, Tape width(FIFA Test Method 25) - 0.15-0.15mm, Colour change(EN ISO 20105-A02) - ≥Grey scale 3, TURF Pile height(ISO2549): 15mm ±1mm, Gauge(ASTM D5793) : 3/16 inch, Stitch /10cm(ISO1763) 33 ±3%, Density/m²(ISO1763) - 69300 ±10%, Yarn weight(ISO8543) - 1,372g/m² ±10%, Tuft withdrawal force(FIFA TestMethod 26) - One tuft≥35N, Backing Primary backing: PP cloth + Mesh fabric , Weight : 175g ±10%, Secondary backing : Black SBR Latex , Weight : 1153g ±10%, Total weight(ISO8543) : 2700g/m² ±10% |
| 237 | S/I/T/C of Dosing System for Chlorine & PH with Container Constant Flow membrane Dosing System chlorine Dosing to have residual chlorine presence in the Swimming Pool and act as a backup for Ozoniser. 15 lph @5 bar. Make:- Pentair or Equivalent R.A. Unit : 1 / Per No. (As per PMC Bhavan DSR 2023-24, Swimming Pool, 3116, Page No.214) |
| 238 | Providing and Fixing .POOL ACCESSORIES: Wall Inlet Regulable type floor inlets mead in ABS plastic having max. Flow 10000 Make :- Cryster Engineering R.A. Unit : 1 / Per No. (As per PMC Bhavan DSR 2023-24, Swimming Pool, 3103, Page No.213) |
| 239 | Providing and Fixing .POOL ACCESSORIES: Overflow Gratings Suitable for 12\\" wide over flow gutter modular type available in different colors made in PP Plastic Make :- Cryster Engineering R.A. Unit : 1 / Running Metre. (As per PMC Bhavan DSR 2023-24, Swimming Pool, 3102, Page No.213) |
| 240 | Plumbing All 10 kg. Per cm sq. ISI mark PVC pipe and fittings Make Prince / Finolex / equivalent . 75mm Pipe R.A. Unit : 1 / Running Metre 75 mm Dia. x 10 Kg/cm2 (As per PMC Bhavan DSR 2023-24, Swimming Pool, 3096, Page No.213) |
| 241 | Plumbing All 10 kg. Per cm sq. ISI mark PVC pipe and fittings Make Prince / Finolex / equivalent . 63 mm Pipe R.A. Unit : 1 / Running Metre 63 mm Dia. x 10 Kg/cm2 (As per PMC Bhavan DSR 2023-24, Swimming Pool, 3097, Page No.213) |
| 242 | BASIC FILTRATION SYSTEM Filter :Filter Media R.A. Unit : 1 / Kilogram. (As per PMC Bhavan DSR 2023-24, Swimming Pool, 3093, Page No.213) |
| 243 | MAINTENANCE EQUIPMENTS: Suction Trolley Made in SS 304 Mounted on wheels and handels wirh FRP Platform mounted with self priming pump (1 HP), starter and cable etc. suitable to adopt suction Flexible PVC hose pipe 15m length for maintenance and cleaning purpose.It icludes two core wire lead 20m, 1feet long vaccum head with brush all fitting and nozels Make :- Cryster Engineering R.A. Unit : 1 / Per No. (As per PMC Bhavan DSR 2023-24, Swimming Pool, 3107, Page No.214) |
| 244 | MAINTENANCE EQUIPMENTS : Leaf RackR.A. Unit : 1 / Per No. (As per PMC Bhavan DSR 2023-24, Swimming Pool, 3108, Page No.214) |
| 245 | MAINTENANCE EQUIPMENTS : Poo brush curved type R.A. Unit : 1 / Per No. (As per PMC Bhavan DSR 2023-24, Swimming Pool, 3109, Page No.214) |
| 246 | MAINTENANCE EQUIPMENTS : 2 in 1 pH & CL testing kit R.A. Unit : 1 / Per No. (As per PMC Bhavan DSR 2023-24, Swimming Pool, 3113, Page No.214) |
| 247 | Supply, Installation, Testing and Commissioining of Verticle Type FRP Boobin Wound Pressure Sand Filter, Totally anticorrosive filte rof 2000 mm dia., Manufactured with fiber glass & polyster resin, fitted with collector arms & diffuser made from unplastisized PVC & polypropelene, capable of accomodating a flow rate of 125 cum / Hour, Velocity of Filter: 40 cum / Hour / Sqm. Filter Bed Depth 1.0 mtr., Inlet Outlet Connection Size: 140 /160 mm, complete with lid in polyester resin & fiber glass, manual air purge, cap for sand discharge & PVC flanged connection for inlet & outlet. Make- Aqvastar/AstralPool/ Waterco |
| 248 | Supply, Installation, Testing and Commissioining of of 5-Valve batteries built entirely in UPVC with flange connections to filters according to DIN standards. Butterfly valves also in uPVC PN-10 Rated. with Required PVC Fittings such as Equal Tee, Elbow , Stub End and Flanges of PN-10 Rated, supports made of zinc coated steel pipe with antivibration clamps & fixing plugs, Conn.140 mm /160 mm dia. Make- Aqvastar/AstralPool/ Waterco |
| 249 | Supply, Installation, Testing and Commissioining of Single stage/Horizontal Plastic pumps set with inbuilt prefilter,Thermoplastic injected pump casing. Impeller in Brass or noryl with Stainless steel shaft, mechanical seal in stainless steel connected to TEFC induction motor with built-in thermal protection and automatic reset suitable for 190/ 380 volts, 10 HP, 3 phase, 50 cycles A.C supply, IP-55 motor protection complete with inbuilt Filter basket in injected plastic material, Flow 125 m3/hr. @ 12-14 Mtrs. Head (Working 2 Nos. , Standby : 1 No.) Make- Aqvastar/AstralPool/ Waterco |
| 250 | Supply, Install, Testing & commissioning uPVC Piping including necessary fitting such as Elbows, Bends, Sockets, Tees, Collars, Nipples, Reducers, Stub Ends, diminishing pieces, Solvent Cement, etc. for Swimming Pool Inlet & Drain & Suction piping, Swimming Pool filtration plant piping, drain pipe along the pipe periphery including all fittings, fixtures and Ceiling/ Wall Support System suitable for following uPVC pipe as specified and directed. 90 mm Dia. x 10 Kg/cm2 Make Prince / Finolex / equivalent |
| 251 | Supply, Install, Testing & commissioning uPVC Piping including necessary fitting such as Elbows, Bends, Sockets, Tees, Collars, Nipples, Reducers, Stub Ends, diminishing pieces, Solvent Cement, etc. for Swimming Pool Inlet & Drain & Suction piping, Swimming Pool filtration plant piping, drain pipe along the pipe periphery including all fittings, fixtures and Ceiling/ Wall Support System suitable for following uPVC pipe as specified and directed. 110 mm Dia. x 10 Kg/cm2 Make Prince / Finolex / equivalent |
| 252 | Supply, Install, Testing & commissioning uPVC Piping including necessary fitting such as Elbows, Bends, Sockets, Tees, Collars, Nipples, Reducers, Stub Ends, diminishing pieces, Solvent Cement, etc. for Swimming Pool Inlet & Drain & Suction piping, Swimming Pool filtration plant piping, drain pipe along the pipe periphery including all fittings, fixtures and Ceiling/ Wall Support System suitable for following uPVC pipe as specified and directed. 160 mm Dia. x 10 Kg/cm2 Make Prince / Finolex / equivalent |
| 253 | Supply, Install, Testing & commissioning uPVC Piping including necessary fitting such as Elbows, Bends, Sockets, Tees, Collars, Nipples, Reducers, Stub Ends, diminishing pieces, Solvent Cement, etc. for Swimming Pool Inlet & Drain & Suction piping, Swimming Pool filtration plant piping, drain pipe along the pipe periphery including all fittings, fixtures and Ceiling/ Wall Support System suitable for following uPVC pipe as specified and directed. 200 mm Dia. x 10 Kg/cm2 Make Prince / Finolex / equivalent |
| 254 | Supply, Install, Testing & commissioning of PN-10 Rated 200 mm dia. UPVC Suction valve (Butterfly Type) Complete with uPVC stud ends, uPVC flanges, Platted Nut bolts and washers. (For Pump Suction- 3 Nos., For Pool Inlet -1 No.) Make- Aqvastar/Cepex/Pimtas |
| 255 | Supply, Install, Testing & commissioning of PN-10 Rated 160 mm dia. UPVC Suction valve (Butterfly Type) Complete with uPVC stud ends, uPVC flanges, Platted Nut bolts and washers. (For Pump Delivery - 3 Nos., For Pool Drain -1 No.) Make- Aqvastar/Cepex/Pimtas |
| 256 | Supply, Install, Testing & commissioning of PN-10 Rated 160 mm dia. UPVC Check valve (Wafer Type) Complete with uPVC stud ends, uPVC flanges, Platted Nut bolts and washers. (For Pump Delivery- 3 Nos.) Make- Aqvastar/Cepex/Pimtas |
| 257 | S/I/T/C of PN-10 Rated 160 mm dia. UPVC Foot valve (Ball Type) Complete with uPVC stud ends, uPVC flanges, Platted Nut bolts and washers. (For Pump Suction - 3 Nos.) Make- Aqvastar/Cepex/Pimtas |
| 258 | S/I/T/C of VGBA Approved Drain grating in ABS Plastic , Frame in injected moulded plastic, Size of Grill - 450mm x 450mm. Make- Aqvastar/Pentair/Aqua |
| 259 | Supply and Installation of S.S.304 Ladder (4 Step) SS ladder with polished stainless steel hollow pipe of 43mm Dia. and of 14 gauge(1.6mm) thick, Anti-slip stainless steel steps with anchoring fixtures. Make- Make- Aqvastar/Pentair/Aqua |
| 260 | Supply, Install, Testing & commissioning of Electrical Control Panel for Filtration Plant Pumps and Chlorine Dosing System factory made, Suitable for 415V, 3 phase, 4 Wires, 50 Hz, fabricated out of 16 SWG CRCA steel Sheet, IP 52, Floor mounting type, The steel sheet shall undergo minimum seven tank treatement followed by finishing powder coating of min. 60 microns thickness. Star delta starters with SPP, 3 Nos. of phase indicating lights, flush mounted Ammeter, Voltmeter, Selector Switches, Protective fuses.The board includes removable gland plates, cable glands, including connection with outgoing feeders complete with all respects. also includes all required cabling from Panel to Pumps with Cable, Cable Trays, Conduits, ect. within Plant Room. |
| 261 | Supply and Installation of Starting Blocks with mounting frames and foundation bolts - The starting block is manufactured using AISI-304 painted with epoxy resins or polished and dip of plate size 500 x 500 mm. x 700 mm height. high density polyethylene with no-slip machining Top platform, adjustablem Angle of diving platform surface max 10°. Double handle horizontal and vertical for backstroke start. The starting block is provided to numbers standard in 4 sides. Made in according with FINA regulation in force. Make- Aqvastar/AstralPool/ Waterco |
| 262 | Supply and Installation of Float lane - 50 mtrs. long x 100 mm Dia. anti wave breaker lane ropes made made in polyethylene with anti-acid and anti UVA treatments with special feature for eliminate wave movement. Complete with spring tensioner all in stainless steel 316L and cover in silicon, in according with EN 13451-5 and FINA regulation in force. Suitable for high level competitions including SS 316L float line fixing post anchored on the deck. Make- Aqvastar/AstralPool/ Waterco |
| 263 | Supply and Demonstration of Metallic vacuum head in Anodised Aluminium, 800 mm Long, connection external 2” to fit hoses, fork in Stainless Steel. for connection. Make- Aqvastar/AstralPool/ Waterco |
| 264 | Supply and Demonstration of Extensible handles for cleaning attachments in anodized aluminium which can be adapted to the entire range of cleaning equipment, brushes, leaf skimmers and scoops, 9 feet to 27 feet. Long. Make- Aqvastar/AstralPool/ Waterco |
| 265 | Supply and Demonstration of Transparent plastic vacuum hose 2” dia 30 mtrs. long including hose cuffs for connection to suction inlets. Make- Aqvastar/Pentair/Aqua |
| 266 | Supply and Demonstration of Algae brushes with stainless steel bristles. Make- Aqvastar/AstralPool/ Waterco |
| 267 | S/I/T/C of Automatic pH Correction system comprise of an automatic proportional dosing system combining controller, electrical box and hydraulic by-pass probe holder in a single ready-to install unit. IP65 enclosures protect against water jets, Should Include two washable cartridge filters. 100 ltrs. Capacity PVC tank and PVC stirrer. Make- Aqvastar/AstralPool/ Waterco |
| 268 | Supply of Float Lane Storage designed to transport and store the Float Line after use in the swimming pool. Easy to use and aesthetically discreet. The float line roller is manufactured using AISI-304 Stainless Steel The cart has four rotating wheels for maximum mobility. Two of these have a brake. Suitable for Storage of 1 No. of 50 mtrs. long x 100 mm Dia. Float lane. Make- Aqvastar/AstralPool/ Waterco |
| 269 | Supply and Installation of BACK STROKE TURN INDICATOR POST - comprising of 2 no stainless steel SS 316L posts each of 48 mm dia and 1.8 m height provided on either side of the racing pool properly anchored in a suitable anchoring socket on the deck at specified location and shall span across the sides including set of flags as per specifications as per FINA. Make- Aqvastar/AstralPool/ Waterco |
| 270 | Supply and Installation of FALSE START INDICATOR POST- comprising of 2 nos. stainless steel 316L posts each of 48 mm dia and 1.8 m height provided on either side of the racing pool properly anchored in a suitable anchoring socket on the deck at specified location including one post provided with pulley and quick cord fixing and loosening device and including false start line comprising of polyester cord and a float. as per FINA. Make- Aqvastar/AstralPool/ Waterco |
| 271 | Providing and laying Petit Carre Porcelain Finger Grip Tile with Safety Marking of size 245 mm x 120 mm and thickness 18 mm conforming to FINA (Federation International De Nation) Standard on Horizontal surface (Coping) in swimming pool of approved manufacturer and of shade approved by architect or engineer in charge like Cobalt etc. laid in approved pattern on 3- 6 mm ( 5 mm average) thick bed of adhesive mortar of Polymer modified cementitious adhesive ( Bal Endura gold star / latecrete / Rock force ) in conjuction with polymer modified liquid Bal Endura admix Adlor equivalent product of latercrete / Rock force mixed in required porportion as specified by manufacturer including filling / scaling of joints 3-4 mm thick between the tiles with epoxy grout of Bal Endura Epoxy grout / Latecrete / Rock force with matchingcolour pigment to make it water tight and finished neat complete as per direction of Engineer-in-Charge. Make- Serapool/ Agrob Buchtal/Endura |
| 272 | Providing and laying Porcelain Petit Carre Antislip Tile with of size 245 mm x 120 mm and thickness 6.8 mm conforming to FINA (Federation International De Nation) Standard on Horizontal surface (Coping) in swimming pool of approved manufacturer and of shade approved by architect or engineer in charge like unglazed etc. laid in approved pattern on 3- 6 mm ( 5 mm average) thick bed of adhesive mortar of Polymer modified cementitious adhesive ( Bal Endura gold star / latecrete / Rock force ) in conjuction with polymer modified liquid Bal Endura admix Adlor equivalent product of latercrete / Rock force mixed in required porportion as specified by manufacturer including filling / scaling of joints 2-3 mm thick between the tiles with epoxy grout of Bal Endura Epoxy grout / Latecrete / Rock force with matchingcolour pigment to make it water tight and finished neat complete as per direction of Engineer-in-Charge. Make- Serapool/ Agrob Buchtal/Endura |
| 273 | Providing and laying Porcelain Petit Carre Bevelled Edge Antislip Tile with of size 245 mm x 120 mm and thickness 6.8 mm conforming to FINA (Federation International De Nation) Standard on Horizontal surface of Rest Ledge in swimming pool of approved manufacturer and of shade approved by architect or engineer in charge like unglazed etc. laid in approved pattern on 3- 6 mm ( 5 mm average) thick bed of adhesive mortar of Polymer modified cementitious adhesive ( Bal Endura gold star / latecrete / Rock force ) in conjuction with polymer modified liquid Bal Endura admix Adlor equivalent product of latercrete / Rock force mixed in required porportion as specified by manufacturer including filling / scaling of joints 2-3 mm thick between the tiles with epoxy grout of Bal Endura Epoxy grout / Latecrete / Rock force with matchingcolour pigment to make it water tight and finished neat complete as per direction of Engineer-in-Charge. Make- Serapool/ Agrob Buchtal/Endura |
| 274 | Providing and Laying Precast M-20 Saucer Drain with smooth finish embedded 125mm below ground level over M-10 PCC finished neatly joint filling with Cement Mortar, setting the same in Cement Mortar and grooved including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface, Using Concrete Batching and Mixing Plant, including Shuttering/ Mould Curing, Placing, Laying, Levelling all Complete. as specified and directed by Engineering In-charge |
| 275 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification NoWG-MA/CC |
| 276 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No.WG-MA/CC |
| 277 | Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW |
| 278 | Supplying and erecting green colour earthing with 1x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW |
| 279 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW |
| 280 | Supplying and erecting green colour earthing with 1x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW |
| 281 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 282 | Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. |
| 283 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. |
| 284 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. |
| 285 | Supplying and erecting modular type (two module) electronic step regulator for fan duly erected on provided plate and box with wiring connections complete. |
| 286 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar/ POP as per required to match the background. |
| 287 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar/ POP as per required to match the background. |
| 288 | Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW |
| 289 | Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW |
| 290 | Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 770 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 291 | Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 2750 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10%p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 292 | Supplying and erecting LED Strip light 5m Length Max. 95 W IP20 class having minimum lumens output of 1600 Lumens/m min. efficacy of 90 lumen/W CRI>80 CCT upto 5000K Beam Angle of 110 deg. THD<10% p.f. >0.95operating range of 230-270V Life class of 30 000 Hrs. at L70B50 including driver with 1 year warranty. |
| 293 | Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades wire mesh duly erected complete. |
| 294 | Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF |
| 295 | Supplying and fixing anchor type fastener fan hook with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. |
| 296 | Supplying and erecting ‘B’ class G.I .pipe /M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. |
| 297 | Carrying out core cutting of size 3 to 5dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. |
| 298 | Supplying, erecting and marking SPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 299 | Supplying, erecting and marking SPMCB 6A to 32A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 300 | Supplying and erecting triple pole and neutral distribution board (TPNDB) SPMCB of 4 ways/phase (12 poles) with door 1.2mm thickness surface/flush mounted IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 301 | Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs with door1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 302 | Supplying, fixing, and commissioning 2 pole RCBO 6/10/16/20/25A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO |
| 303 | Supplying, fixing, and commissioning 2 pole RCBO 32/40A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO |
| 304 | Supplying, fixing, and commissioning 4 pole RCBO 32/40A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO |
| 305 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no.CB-LT/AL |
| 306 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no.CB-LT/AL |
| 307 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3 core6 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 308 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials testing & recording the results as per specification no. EA-EP |
| 309 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with insulating and non-corrosive bond with required joints As per specification no. EA-EP. |
| 310 | Supplying, installing, testing and commissioning of 11kV 630A 21kA/3sec 2 way Indoor/outdoor extensible motorised SCADA compatible RMU internal arc tested consisting of 1 no. feeder with 1 LBS and 1 no. feeder with 1 VCB compliant to IEC 62271 -100 2 00 and 102 as per specification no.SW-HTS/RMU SCADA |
| 311 | Supplying, installing, testing and commissioning of 3 phase 11/0.433 kV 50 Hz. 315 kVA mineral oil immersed and naturally cooled outdoor type Copper wound without gas cushioning hermetically Sealed transformerdelta/star connected with additional neutral brought out on load side temperature rise should not exceed 45? by thermometer in oil and 50? by the resistance method in winding at full load rating using type A winding insulation (kraft paper) with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5% having 7 number of tap positions with standard accessories complete with test certificate with losses below 1025 Watts at 50% load 3100 Watts at 100% load as per IS 1180(part 1) 2014 with necessary permissions of Electrical Inspector as per specification no SS- TR-SL |
| 312 | Making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete. |
| 313 | Supplying, erecting & terminating XLPE insulated galvanised steel formed wire armoured (strip) cable 11 kV(UE) 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT |
| 314 | Supplying and erecting 11 kV outdoor type gang operated air break triple pole switch 200 A capacity with 3 post pin type insulator per phase mounted in horizontal or vertical position with necessary channels on provided crossarm with adequate length of C class G.l. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp. |
| 315 | Supplying and erecting 11 kV outdoor type drop out fuse with insulator complete with fuse holders fuse barrel with metal fitting fuse element mounted on M.S. channel with working current of 15A capacity complete erected on provided cross arm. |
| 316 | Supplying and erecting 11 kV fuse barrel with metal fittings complete. |
| 317 | Supplying heavy duty operating rod outer dia 25 mm & inner dia 20 mmsuitable for 11 kV with brass couplings etc. for removing drop out fuses at 6 meters length 4 pieces each with rain shade with hand grip including earthling chain 1.5m complete. |
| 318 | Supplying and erecting copper tubular bus 20 mm dia 1.6 mm (16 SWG) thick for the use of high tension over head bus and erected on provided HT insulators with clamps nuts and bolts complete. (weight per meter of bus is about 1.7 kg.) |
| 319 | Supplying and erecting clamps made out of 25x3 mm copper strips to be fixed to tubular bus for connecting the bare copper wire to other equipment with brass nuts bolts of suitable dia complete. |
| 320 | Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG |
| 321 | Supplying and erecting porcelain pin type insulator with GI pin suitable for 11kV line complete as per specification no.OH-INS/PN |
| 322 | Supplying and erecting distribution class 11 kV thyrite type lightening arrester with nut bolts on provided MS channel as per specification no. OH-INS/LA |
| 323 | Supplying and erecting rolled steel joist (girder) pole 100 x 116 mm (23 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ |
| 324 | Supplying and erecting rolled steel joist (girder) pole 125 x 70 mm (13.3 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ |
| 325 | Supplying and erecting V cross arm with ISM channel of 75x40x6mm for 11kV HT OH line with arrangement to fix insulator at 45mm from the end & horizontal distance between insulators 1220mm bent at angle of 60 degree keeping base 305mm and the total vertical height of V cross arm as 460mm and fixed on pole with MS clamp of 80x10 mm nut bolts washers complete as per specification no. OH-PL/VCA |
| 326 | Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 327 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials testing & recording the results as per specification no. EA-EP |
| 328 | Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessaryG. I. Clamps fixed on wall/cable/ conduit with screws complete. |
| 329 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP |
| 330 | Providing SITC of Main Panel having details as belowThe panel shall be comprising of following & IEC 61439 Panel should be fully ompartmentallised Floor mounted withM.S. Channel dully painted fabricated of 14/16swg CRCA sheets completely derusted chemically treated and powder coated with approved shade ON - Off Indicating LED lamp locking arrangements withdual source intelligent flush mounted panel meter three phase four wire (IPM) 415V CT/ PT site programmable class I flush mounted (96 x 96mm) meter with voltage current frequency power factor ON hrs kWhEB and DG set metering and LT current transformer with bar primary 50/5 to 1600/5 ratio with 15 VA burden with IOT Based metering stsyem and gateway included as per SLD having following items - (MSEDCL APPROVED)Main Incomer 1 Nos - 1000A 4P ACB EDO individual fault trip alarm and trip indication mechanical and electrical anti pumping soft/hard rating plug (including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication min. 5 event and trip history on breaker display Outgoing 2 Nos 3 Pole MCCB 415V 320A (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bia Outgoing 6 Nos 3 Pole MCCB 415V 200A (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bia Outgoing 4 Nos 3 Pole MCCB 415V 100A (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bia(NON CSR) |
| 331 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no.CB-LT/AL |
| 332 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no.CB-LT/AL |
| 333 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no.CB-LT/AL |
| 334 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no.CB-LT/AL |
| 335 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no.CB-LT/AL |
| 336 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/pipe as per specification no. CB-LT/AL |
| 337 | Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface to required depth complete. |
| 338 | Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface to required depth complete. |
| 339 | Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 200 mm outside dia double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface to required depth complete. |
| 340 | Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface to required depth complete. |
| 341 | Supplying erecting testing and commissioning of DIESEL GENERATING SET with alternator confirming to CPCB-IV plus Emission Compliant output continuous rating 3 phase 415 V 50 Hz 0.8 p.f. A.C. supply a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours along with standard accessories self-excitedself-regulated screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 % with performance class G3 and maximum fuel consumption ltr/hr 75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters switchgears indicators connected with suitable wires/cables the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA sheet sound absorbing material to restrict sound level up to 75 dB at 1.0 m provided with first filling of oil suitable capacity DEF tank diesel not less than 690 ltr etc. on provided M20 grade CC foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG This D.G set is Fitted in Soundproof & Weather Proof Acoustic Enclosure as per CPCB IV plus Emission Compliant (with acoustic enclosure as per latest Government norms) approved Norms. for bellow mentioned capacity Diesel Generating Set DG Set Capacity 200KVA 3 Phase Maximum Fuel Consumption (Ltr/Hr 75% Loading)34.4 Diesel Tank Capacity ( Ltrs) 425 |
| 342 | Supplying and erecting Supplying erecting testing and commissioning of microprocessor based AMFpanel suitable for diesel generating set of above 180 kVA up to 200 kVAcapacity Three phase 415 Volts 50HzA.C. with all standard features safeties etc as per specification no. GEN-AMF. |
| 343 | Supplying and erecting PVC insulated PVC round sheathed 4 sq.mm (56 no. x 0.30 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV |
| 344 | Design supply installation testing and commissioning of 24-Meter (20 Mtr+ 4 Mtr)-High sports mast made of 4 sections. The 3 sections form the part of the Main High mast and fourth section is part of the Head Frame. The mast should be capable of mounting Min 27 Nos of 1000W Fixtures. The mast should be designed for 50m/s wind speed. The mast should be HOT Dip Galvanized type as per BS EN ISO 1461 or Equivalent. All the sections of the Main Mast should be of Min 5mm 6mm and 8mm thickness for 3 sections and the Top Frame section should be of 4mm Thickness. The Height of Main Mast section should be min 7300mm each and Head frame should be min 4000mm. The Mast should be of Min 20 polygon type.The Bottom Dia of the Main High mast should be Min 650 mm and top Dia should be min 300mm. The main mast part should be made in 3 sections of size 7300mm Bottom 7300mm Middle and 7300mm Top. The overlap between the Bottom and Middle section of the mast should be Min 1000mm and Middle and Top section should be Min 900mm. The Trap Door should be located at a height of 500mm from the base and should be of size 1200mm with a width of 300mm. The Head Frame should be of min 4000mm height x min 5000mm width. It should have max 3 landings. The top 2 landings should be able to accommodate min 10-10 fixtures. The bottom landing should accommodate 7 fixtures. The Head Frame should be of 4mm thickness. The Base Plate for the mast should be 40mm thick of Dia min 870mm. The hole PCD should be of min 760mm.The Base plate should have 20nos of 32mm Dia holes for anchor bolts. The base plate and the anchor plate should be of the same details. The Foundation bolt should be of M30 type and length should be of 1200mm. The Shaft should comply to A572-50/S355/E350 or Equivalent. The Base plate Flats and Other Plates should be as per IS 2062 E250 or Equivalent. All welding should be as per BS 5135/AWS D1.1 or Equivalent. The Mast shall have one or more longitudinal welds. The winch should be of motorized type. Similar to Make- Wipro / Habells |
| 345 | SITC of the Manriding Lift Single number and useable for rest 3 Masts ditachable.The man rider unit should be motorised type. The Length width height of the man rider unit cage shoul be minimum2500mm X 1200 mm X 1000mm. The load carrying capacity of the men riding unit should be minimum 300kg. The Load Capapcity of the which should be min 1500kg. Atrouble free fall arrestor system shall be provided as protection against failure of main wirerope. the fall arrestor system shall be operated automatically without any manual interfernce by the the integral power tool system operated with the help of suitable winch in the base section of the mast. The man rider cage shall be provided with suitable wheels for easy transportation from one mast to another. The climb rate of manrider shall be 9m/Min. |
| 346 | Supplying and erecting 20 m (clear height) motorized high-mast (Top-150mm Bottom-460 mm) hot dipped galvanized material with average minimum thickness 65 micron made from high tensile structure grade steel as per BSEN -10025 S 355/E350 & 3+4 mm thickness with base plate 25 mm Thick x OD 670 mm grade as per IS-2062 pole made in single section & submerge arc welded with lowering & raising motorized unit wire rope stainless steel -316 grade 2 nos. 7x19 construction 6 mm SG-DG U clamps double drum winch assembly 500 kg 5x2.5 sq.mm. flexible copper cable with lantern carriage assembly suitable for max. 16 nos. luminaires and its control gear box lightning arrestor arrangement for fixing aviation light high-mast with serial number factory inspection report/test report of high-mast should be provided asper specifications on provided foundation J type stud/bolts with necessary accessories complete. specification no. OH-PL/HM (excluding luminaries) |
| 347 | Supplying and erecting 16 m (clear height) motorized high-mast (Top-150mmBottom-410 mm) hot dipped galvanized material with average minimum thickness 65 micron made from high tensile structure grade steel as per BSEN -10025 S 355/E350 & 3 mm thickness with base plate 25 mm thick x OD 570 mm grade as per IS-2062 pole made in single section & submerge arc welded with lowering & raising motorized unit wire rope stainless steel 316 grade 2 nos. 7x19 construction 6mm SG-DG U clamps double drum winch assembly 350 kg 5x2.5 sq.mm flexible copper cable with lantern carriage assembly suitable for max. 16 nos. luminaires and its control gear box lightning arrestor arrangement for fixing aviation light high-mast with serial number factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete. specification no. OH-PL/HM (excluding luminaries) |
| 348 | Supplying and erecting 12.5 m (clear height) motorized high-mast (Top -150mm Bottom- 360mm) hot dipped galvanized material with average minimum thickness 65 micron made from high tensile structure grade steel as per BSEN - 10025 S 355/E350 & 3mm thickness with base plate 25 mm thick x OD 520 mm grade as per IS-2062 pole made in single section & submerge arc welded with lowering & raising motorized unit wire rope stainless steel 316 grade 2 nos. 7x19 construction 5mm SG-DG U clamps double drum with assembly 250 kg 5x2.5 Sq.mm. flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box lightning arrestor arrangement for fixing aviation light high-mast with serial number factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete as per specification no.OH-PL/HM (excluding luminaries) |
| 349 | Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 63A TPN MCB incomer 24hr astronomical time switch with minimum 5 Years battery backup IP 54 and IK10 protection 45 A TP contactor for automatic switching of luminaires 2 no 9A contactors and raise/lower push button and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box powder coated with supporting angles self lock gasket and slanting top erected on CC foundation complete. |
| 350 | Supplying, erecting and marking SPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 351 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials testing & recording the results as per specification no. EA-EP |
| 352 | Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessaryG. I. Clamps fixed on wall/cable/ conduit with screws complete. |
| 353 | Providing and erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 100 mm height comprising all required standard accessories. |
| 354 | Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template duly plastered as per design complete (for 20 m raising lowering high mast) . |
| 355 | Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template duly plastered as per design complete (for 16 m raising lowering high mast). |
| 356 | Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template duly plastered as per design complete (for 12.5 m raising lowering high mast). |
| 357 | Making M- 20 cement concrete foundation suitable by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template duly plastered as per design complete (for 25 m high mast). |
| 358 | Supplying and erecting integrated LED flood light fitting Max. 500W IP65 & IK07 class having pressure die-cast aluminium housing including driver with bracket for suitable for sports high-mast installations including stainless-steel bolts nuts washers aiming clampsvibration-resistant mounting hardware and cable entry glands. Similar to Make Wipro/HavellsSystem Parameters as below1.lumens output of Min. 72500 Lumens2. min. efficacy of 140 lumen/W3. CRI>704. CCT upto 5700K5. THD<10% p.f. >0.956. Nominal voltage range of 240V7. Built-in potted electronic Analog Dimmable LED driver with APFC(SMPS based constant current supply) lower THD Open Circuit protection Over Voltage protection Surge Voltage protection upto 4kv internal & 10kV with SPD & other safety test as per IS 15885 Part-2/Sec 13 & CISPR15. |
| 359 | Supplying and erecting integrated LED flood light fitting Max. 250W IP65 & IK07 class having pressure die-cast aluminium housing including driver with bracket for suitable for sports high-mast installations including stainless-steel bolts nuts washers aiming clampsvibration-resistant mounting hardware and cable entry glands. Similar to Make Wipro/HavellsSystem Parameters as below1.lumens output of Min. 30000 Lumens2. min. efficacy of 142 lumen/W3. CRI>704. CCT upto 5700K5. THD<10% p.f. >0.956. Nominal voltage range of 240V7. Built-in potted electronic Analog Dimmable LED driver with APFC(SMPS based constant current supply) lower THD Open Circuit protection Over Voltage protection Surge Voltage Protection upto 6 kV & other safety test as per IS 15885 Part-2/Sec 13. |
| 360 | Supplying and erecting integrated LED flood light fitting up to 1000W with IP66 dust and water protection and IK07 impact resistance made of pressure die-cast aluminium housing. The luminaire shall deliver a minimum system lumen output of 120 000 lumens minimum efficacy of 120 lm/W CRI > 70 CCT up to 6500K THD < 10% and Power Factor > 0.90. It shall operate reliably within 140–270V and include inbuilt surge protection of minimum 4 kV. LED life shall be minimum 50 000 hours (L70B50). The fitting shall include a high-efficiency constant-current LED driver and be supplied with a U-shaped/required mounting bracket along with complete mounting accessories suitable for sports high-mast installations including stainless-steel bolts nuts washers aiming clamps vibration-resistant mounting hardware and cable entry glands. Similar to Make Wipro/Havells |
| 361 | SITC of Outdoor type Mini Feeder Panel having details as below The panel shall be comprising of following & IEC 61439 Panel should be fully ompartmentallised Floor mounted with M.S. Channel dully painted fabricated of 14/16swg CRCA sheets completely derusted chemically treated and powder coated with approved shade ON - Off Indicating LED lamp locking arrangements withdual source intelligent flush mounted panel meter three phase four wire (IPM) 415V CT/ PT site programmable class I flush mounted (96 x 96mm) meter with voltage current frequency power factor ON hrs kWh EB and DG set metering and LT current transformer with bar primary 50/5 to 1600/5 ratio with 15 VA burden with IOT Based metering stsyem and gateway included as per SLD having following items - Main Incomer 1 Nos - 3 Pole MCCB 415V 400A (Ics=100% of Icu)Microprocessor with LSIG Protection in Panel Outgoing 6 Nos 3 Pole MCCB 415V 100A (Ics=100% of Icu)Microprocessor with LSIG Protection in Panel |
| 362 | Supplying, installing, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 1800 to 2280 LPM at 80 to 60 m head driven by electric motor 415 volts 3 phase 50 Hz AC supply of 37kW or of suitable kW capacity for manual/automatic operation and consisting of following(a) Horizontal type single stage centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade) mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor TEFC synchronous speed 3000 RPM suitable for operation with IP 55 protection for enclosure horizontal foot mounted type with Class-'F' insulation conforming toIS-325.(c) M.S. fabricated Common base plate coupling coupling guard foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-MFP/SSC/EP |
| 363 | Supplying, installing, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 120 to 90 m head driven by 110 HP or suitable HP capacity diesel engine at required working speed suitable for automatic operation and consisting of following(a) Horizontal type single stage centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade) mechanical seal conforming to IS 1520.(b) Water cooled with radiator diesel engine conforming to relevant IS standard complete with auto starting mechanism 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v 50Hz AC supply diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine exhaust pipe extended up to 10 m outside pump houseduly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding residential silencer instruments and protection as per standardspecification stop solenoid for auto stop in the event of fault with audio indications etc. as required.(c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-MFP/SSC/DP |
| 364 | Supplying, erecting, testing & commissioning of fire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring &cabling along with allied accessories with following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specifications the capacity of electric motor driven pump are as follows a. Main fire pump(MFP) having capacity of 22kW 1no (1 working)b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby, alternate run per start in auto mode) comprises of the following features & switchgears:1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating.2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU's, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc.3. Individual pump TPN SFU having rotary handle with HRC fuses of suitable rating.4. Digital voltmeter & ammeter & RYB indicating lamps & push buttons & SPP, O/L & phase reversal protection with emergency stop switch.5. TPN SPD 100kA Type 1 +2 tested.6. Required pressure transducer with pressure indication on panel with cabling required for monitoring & automatic operation of fire pumps.7. System controller to control operation of main electric fire pump, jockey (pressurization) pumps in sequence with interlocking for operation of pumps as per specification with automatic/manual operation with selector switch & alternate run of standby Pumps consisting of relays, timers. sensors, annunciation window for fault indication, complete as per specification.8.Suitable capacity electric motor starters for all individual pumps with necessary push buttons & indications.9. Siren of required capacity to be activated when main pump starts & allied accessories as per requirements of local CFO or as directed by engineer in charge.10. Danger board as per IS.11. Spare HRC fuses minimum 2nos of each individual rating with required bakelite fuse holder for main & jockey fire pumps MFP=(1working), JP = (1working+1standby, alternate run per start in auto mode) complete panel, as per specification no. FF-MFP/ECP |
| 365 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials testing & recording the results as per specification no. EA-EP |
| 366 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with insulating and non-corrosive bond with required joints As per specification no. EA-EP. |
| 367 | Supplying and erecting 200 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV |
| 368 | Supplying and erecting 100 mm dia. pressure gauge 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve erected with provided G.I. pipe elbow etc. complete as per specification no. FF-FFA/PG |
| 369 | Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve G.I. nipple elbow etc complete as per specification no. FF-FFA/PS |
| 370 | Supplying and erecting 200 mm dia Cast Iron end line strainer of T-Pot type flanged end pattern PN16 pressure rating screen of SS and end connection with flanged for positive suction complete as per specification no. FF-VL/ELS |
| 371 | Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT |
| 372 | Providing G.I. pipe ‘C’ class ERW 200 mm dia with necessary fittings complete as per specification no. FF-PP |
| 373 | Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV |
| 374 | Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia for supplying water in fire tank complete as per specification no. FF-FA/FMC |
| 375 | Supplying and erecting M.S./CRCA cabinet for housing Fire Brigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8 x 6 ) and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) |
| 376 | Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV |
| 377 | Supplying and erecting M.S./CRCA cabinet for housing single hydrant valve of size ( 400 x 400 x 400)mm or hose pipe box of size ( 600 x 600 x 200)mm made from min. 1.5 mm thick CRCA sheet with angle iron work of min. of size (25 x 25 x 4) mm having front doors with viewing glass of size (200x150) mm and locking arrangement with necessary fixingmaterial such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) |
| 378 | Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating as per specification no. FF-VL/GV |
| 379 | Supplying and erecting 63mm dia reinforced rubber lined (R.R.L.) hose pipe 15m in length fitted with necessary accessories complete as per specification no. FF-FFA/RRL |
| 380 | Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system. |
| 381 | Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP |
| 382 | Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP |
| 383 | Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs welded with 4 hooksand duly painted with one coat of red lead and two coats of silver paint complete. |
| 384 | Providing Round bottom fire bucket of 9 Litres capacity as per IS 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark on provided stand/ wall hook complete. |
| 385 | Supplying and erecting ABC powder type fire extinguisher as per IS 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall. |
| 386 | Supplying and erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. |
| 387 | Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing having system lumens output of Min. 6600 Lumens min. efficacy of 110 lumen/W CRI>70 CCT upto 6500K THD<10% p.f. >0.95operating range of 140-270V inbuilt surge protection of 10 kV Life class of 50 000 Hrs. at L70B50 including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 388 | Supplying and erecting integrated LED street light fitting 85-90W IP65 & IK08 class having single piece pressure die-cast aluminium housing having system lumens output of Min. 9300 Lumens min. efficacy of 110 lumen/W CRI>70 CCT upto 6500K THD<10% p.f. >0.95operating range of 140-270V inbuilt surge protection of 10 kV Life class of 50 000 Hrs. at L70B50 including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 389 | Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface to required depth complete. |
| 390 | Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel concrete excavation and fixing provided nut bolts with the help of template duly plastered as per design complete (for 6m to 8m high octagonal/conical GI pole). |
| 391 | Providing and erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F top 70 mm A/F on provided foundation as per specification no.OH-PL/OPL |
| 392 | Providing and erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 200 mm A/F top 100 mm A/F on provided foundation as per specification no.OH-PL/OPL |
| 393 | Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel concrete excavation and fixing provided nut bolts with the help of template duly plastered as per design complete (for 9m & 10m high octagonal/conical GI pole). |
| 394 | Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT |
| 395 | Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT |
| 396 | Supplying, erecting and marking SPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 397 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP |
| 398 | Supplying and erecting triple pole mini feeder pillar with 500V 300A FPMCCB as incomer and 3 outgoing circuits with HRC fuse base and cartridge of 100A with aluminium bus bar erected in 14 SWG CRCA sheet box with supporting angles self locks gasket having IP54 IK10 protection and slanting top to be erected on provided foundation as per specification no. SW-SWR/MFP |
| 399 | Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core16 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/pipe as per specification no. CB-LT/AL |
| 400 | Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV |
| 401 | Supplying and erecting Gate/garden light fitting with 200mm dia. glass bowl suitable for upto 12W LED Lamp on provided pipe as per specification No.FG-ODF/GLT |
| 402 | Supplying and erecting integral post top lantern fixtures (light house type) suitable upto LED 18 W Lamp consisting of combination of spun aluminium canopy & clear acrylic top cover cast aluminium pole cap on provided pole/ bracket as per specification no. FG-ODF/PTL |
| 403 | Supplying and erecting integrated LED Bollard Cylindrical/Cubical shaped 500mm 8W IP65 & IK10 class having extrusion aluminium housing with polycarbonate diffuser having system lumens output of Min. 800 Lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6500K THD<10% p.f. >0.90 operating range of 140-240V inbuilt surge protection of 2 kV Life class of 25 000 Hrs. at L50B50 including driver complete with 2 Year warranty as per specification No FG-ODF/FLS2. |
| 404 | Supplying and erecting minimum Three & above star rated submersible pump set of 2.25 KW/3 HP with 415 V 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 120 to 475 LPM discharge at 36 to 10 m head & discharge & delivery Pipe of Size-50 mm diameter with a necessary H type clamps as per specification No. WP-SMP |
| 405 | Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 5.625 KW/7.5 HP with 415 V 50 c/s. A.C. supply having delivery head from 36 to 14m and discharge from 225 to 1680 litres. per minute& pipe of Suction 75 mm/ Delivery 65 mm diameter erected with necessary H type clamps as per specification No. WP-OSP |
| 406 | Supplying and erecting flat flexible 3 core 6 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. |
| 407 | Supplying and erecting Water level controller 230/415 V A.C. Four way under ground & Over head tank operation only. |
| 408 | Supplying and erecting automatic control panel for 3 Phase 415 volt A.C Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP S.P.P. Combined ammeter/ voltmeter phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing phase reversal phase imbalance etc . |
| 409 | Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP. |
| 410 | Supplying and erecting ISI mark GI pipe 65 mm. dia. ‘B’ class at position with accessories complete as per specification no. CW-PLB/GP. |
| 411 | Supplying and erecting 50 mm dia. cast iron foot valve at position with necessary materials complete. |
| 412 | Supplying and erecting 65 mm dia. cast iron foot valve at position with necessary materials complete. |
| 413 | Supplying and erecting CI flange 50 mm. dia with necessary nuts bolts and washers with rubber seal in position complete. |
| 414 | Supplying and erecting CI flange 65 mm. dia with necessary nuts bolts and washers with rubber seal in position complete. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail