| 1 | Removing Wooden or A.C. partition including frame work and stacking the materials as directed with all leads, lifts, etc. complete. |
| 2 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete. |
| 3 | Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc. |
| 4 | Removing lime or lean cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. |
| 5 | Removing the existing cement plaster of any thickness without causing dust nuisance and stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc. complete. |
| 6 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop iron strips 25 mm X 1.6 mm placed at every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etc. complete. |
| 7 | Providing internal cement plaster 20mm thick in single coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. |
| 8 | Providing and fixing frame work of galvanised iron for suspended false ceiling which includes galvanised iron perimeter channels of size 27 mm and 0.5 mm thick having one flange of 20 mm and other of 30 mm long with perimeter of the ceiling, fixing in brick wall / partition with the help of rawal plugs and screws, suspending galvenised iron intermediate channels of size 45 mm and 0.9 mm thick with two flanges of 15 mm each from the soffit at 1200 mm centres with steel glavanised iron hanger of width 25 mm x 0.5 mm fasteners, ceiling section of 0.5 mm thickness having curved wedge of 51.5 mm and two flanges 0f 26 mm each with lips of 10.5 mm fixed to the intermediate channel with the help of connecting clips and in direction perpendicular to the intermediate channel at 450 mm centres, 12.5 mm dry walls screws at 230 mm centres, fixing screw mechanically either with screw driver or drilling machine with suitable attachement etc. complete. |
| 9 | Dismantling flat wooden or A.C.sheet ceiling with frame work including stacking the materials as directed with all leads, lifts, etc. complete. |
| 10 | Providing and fixing false ceiling of 10 to 12 mm thick decorative boards of fibrous plaster of paris including scaffolding if necessary all architectural work like moulding, cornices, covers, domes, cups as per etailed drawings and three coats of spray painting to boards etc. complete. ( excluding frame work, runners and mild steel suspenders ) . |
| 11 | Providing and Fixing Innovative Recess Interlocking Panle click ceiling system in natural wood reflection which is used both inside and outside. Panles which are hard polymeric surface forming the base for a thermally applied pattern which is finished with high quality thermal printing and protected by a layer of UV-cured lacquer are fitted on existing framing with screw as per manufacturer specification.The panels are resistant to chaning weather condition and biological corrosion and have hideen ventilation for allowing proper moisture removal & air circulation and are protected from moisture, fungi & mould etc complete as directed by Engineer in charge. |
| 12 | Proving and fixing Digital finish Ceramic Tiles of approved quality 600 mm x 1200 mm x 6 mm for dado / flooring in required position with cement mortar and with chemical cement on existing levelled plaster surface or on flooring including joint filling with same colour cement slurry, cleaning, curing etc. complete as directed by Engineer in charge. |
| 13 | Providing and fixing Gypsum board vertical up to 75 mm height with angle of 25 mm x 10 mm x 0.55 mm with gypsum screw complete with jointing and finishing etc as directed by Engineer in charge. |
| 14 | Providing and fixing frame work for wall panneling fixed in vertical section ( 0.5 mm thick having knurled web of 51.5 mm and two equal flange of 26 mm each with lips of 10.5 mm made of G.I. sheet ) placed at 600 mm centres vertically and horizontally MF-7 Intermediate section in equal proportion approximatelly 600 mm and screw fixed to vertical section with 25 mm dry wall screw at 230 mm centres as directed by Engineer in charge. |
| 15 | Providing and fixing 18 mm thick commercial grade for making cupboard / shelf, wall panneling with 2mm thick pvc edge binding including fevicol etc.as directed by Engineer in charge. |
| 16 | Providing and fixing 1 mm thick Mica laminate on existing visible part of 18 mm thick commercial plywood or wood work with fevicol etc. complete as directed by Engineer in charge. |
| 17 | Providing & fixing of 60 mm Low height partition with laminate / Fabric / Marker / Softboard finish partition with double skin provision for 09 mm thick tiles, structure material & all exposed will be Alluminium Anodized finish & the mechanism used from false ceiling to hard ceiling in CRCA powder coated panel finish options are laminated, fabric & sofbboard etc. |
| 18 | Providing and fixing door frame made of Aluminium in Anodized finish ( 35 mm x 15 mm ) size 2.10 mtr x 0.85 mtr. |
| 19 | Providing and fixing of glass door with 12 mm thick Toughened glass with all fitting like floor spring of CNR make, handle, lock etc. with crystal edge polish from both vertical and horizontal side etc. as directed by Enginner in charge. |
| 20 | Providing eatching on existing glass of sliding window / door as per approved designed by Engineer in charge |
| 21 | Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. |
| 22 | Providing and fixing 6 mm thick Commercial grade ply and 1.00 mm thick laminate to existing door shutter on single side including fevicol, nails, handle, mortice lock and accessories etc. complete as directed by Engineer in charge. |
| 23 | Providing and applying priming coat on concrete/masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sabd papering as required etc. compete. |
| 24 | Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. |
| 25 | Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etc. complete. Please Enable Macros to View BoQ information |