| 1 | Ground Development Works - Construction of Mud Football Court |
| 2 | 2.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 3 | OD194979/2025-2026 Sieving excavated Earth through sieve of I.S. designation 4.75 mm and collecting good quality earth for measurement including stacking |
| 4 | OD405857/2025-2026\\"Filling with available excavated earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering and rolling every 3rd and top most layer with power roller of minimum 8 tonnes, for all leads including all lifts involved, all cost of materials, labour charges, hire charges for machineries, conveyance, etc.complete as per the direction of Engineer-in-charge. (Based on DSR item no.50.2.26.1 and 2.2.1) |
| 5 | OD246690/2025-2026\\"Supplying and stacking sieved sand at site for measurement including cost of sand, carriage upto 5 k.m. lead,all labour charges for stacking,loading and unloading etc complete (Based on CPWD 30.2.2 & 30.2.4.3). |
| 6 | OD246691/2025-2026\\"Mixing Departmentally supplied sieved red earth and sieved sand in the required proportion specified or directed by the officer - in- charge including all cost of labour charges, hire charges of machinaries, etc. complete.(Based on CPWD 30.2.9) |
| 7 | OD246692/2025-2026\\"Spreading of mixed Departmentally supplied sieved red earth and sieved sand in the required thickness as per direction of officer - in- charge including all cost of labour charges, hire charges of machineries etc. complete.(Based on CPWD 30.2.8) |
| 8 | OD246700/2025-2026\\"Consolidation of subgrade with power road roller of 8 to 12 tonne capacity with road roller including making good the undulations etc.including all cost of labour charges, hire charges ,fuel,oil etc. complete.(Based on CPWD 16.1) |
| 9 | OD194982/2025-2026\\"Supply and Installation of Fixed type 7's Football Goal Post (3.65m x 1.80m x 1.20m) made of pipe 10cm dia G.I. pipe with nylon net as per the direction of Engineer in Charge including all cost of materilas, labour charges, conveyance, etc. complete. |
| 10 | RR Step Gallery |
| 11 | 2.6.1\\"Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 12 | 2.8.1\\"Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 13 | 4.1.8\\"Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 14 | 60.7.1\\"DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site |
| 15 | 7.1.1\\"Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 16 | 50.6.3.2\\"Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete |
| 17 | 50.6.1.1\\"Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete |
| 18 | 13.7.1\\"12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) |
| 19 | 13.1.1\\"12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 20 | 13.48.1\\"Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm |
| 21 | 10.26.3\\"Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes |
| 22 | 13.61.1\\"Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 23 | Fencing (7.5m height) ,RCC Drain & Electric pole foundation |
| 24 | 2.8.1\\"Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 25 | 4.1.3\\"Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 26 | 4.3.1\\"Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns |
| 27 | 4.1.8\\"Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 28 | 5.1.2\\"Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 29 | 5.9.1\\"Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 30 | 5.9.2\\"Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 31 | 5.22.6\\"Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 32 | OD194972/2025-2026\\"Steel work for fencing with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including all cost of materials, labour charges, hire charges of machineries, charges for welding and bolted with special shaped washers etc. complete. |
| 33 | OD247368/2025-2026\\"Supply and Installation of approved quality 2mm thick UV Stabilized Nylon net of Mesh size not greater than 50mm in existing GI poles including all cost of materials, conveyance, labour charges, etc. as per the direction of Engineer in charge.(Rate base on CPWD 26.81) |
| 34 | 13.61.1\\"Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 35 | OD252569/2025-2026\\"Lifting, conveying and fixing the newly casted RCC covering slabs of any thickness on top of drain in position including all labour charges and miscellaneous expenses etc complete (Based onMoRTH 55.25 ) |
| 36 | Inauguration stone and Name Board |
| 37 | OD194971/2025-2026\\"Providing and fixing 18 mm thick gang saw cut, mirror polished, pre-moulded and pre polished, machine cut for inauguration granite stone of required size, approved shade, colour and texture laid over 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) joint treated with white cement, mixed with matching pigment, epoxy touchups including rubbing, curing etc. complete at all levels. Area of slab over 0.50 sqm(Based on Item 8.2.2.2 of DSR) |
| 38 | 16.21\\"Engraving letters in hard stone |
| 39 | 2.8.1\\"Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, |
| 40 | 4.1.3\\"Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 41 | OD194970/2025-2026\\"Steel work for Name Board with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including all cost of materials, labour charges, hire charges of machineries, charges for welding and bolted with special shaped washers etc. complete. |
| 42 | 10.1\\"Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 43 | 13.61.1\\"Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 44 | 13.71\\"Lettering with black Japan pint of approved brand and manufacture |
| 45 | Flood lighting works for the Mud football court. |
| 46 | OD207479/2025-2026\\"SKFOD_ Supply, installation, testing and commissioning of Outdoor Type Floor Mounting KSEB metering panel, suitable for accommodating 3 Phase Energy meter and consisting of 3 nos. of 63 A cutout with HRC fuse( or as per KSEB) , neutral link in separate chamber,63 A SFU-1 no inter connections and separate cabin shall be provided in outdoor panel to accommodate VDB/DB as per the requirement etc.as required, and including necessary supports of floor or wall mounting as required, and the panelfabricated out of 14 SWG CRCA sheet with lockable door with sealing facility having glass window forenergy meter, sealing facility for KSEB, top canopy and necessary overhang, undergone seven tankprocess ,powder coated finish and all mounting access |
| 47 | OD207481/2025-2026\\"SKFOD_ Outdoor Panel Cabin Supply, installation, testing and commissioning of Outdoor Type panelcabin shall be provided for accommodating VDB/DB as per the requirement etc. as required the item isexcluding VDB/DB and including necessary supports of floor or wall mounting as required, and the panelfabricated out of 14 SWG CRCA sheet with lockable door, top canopy and necessary overhang,undergone seven tank process ,powder coated finish and all mounting accessories. |
| 48 | 90.15.4.11\\"Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 49 | OD252528/2025-2026\\"SKF OD : Supply, Installation Testing, Erection and commissioning of 12mtr fixed type Stadium mast suitable for mounting minimum 12no of luminaries, made of Hot- dip Galvanization process as per IS 4759:1996 with monkey climbing arrangement and maintenance platform for easy maintenance and aiming of luminaries. The pole shaft shall be made of 4mm thickness in 2 sections, base dia not less than 250mm and the base plate shall be of min 20mm thick and including foundation bolts and all accessories as required. Make - Crompton, Bajaj or equivalent approved by engineer in-charge |
| 50 | 90.12.7.41\\"Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp |
| 51 | 90.12.1.41\\"Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 16 sq mm |
| 52 | 90.12.1.39\\"Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 6 sq mm |
| 53 | 90.12.2.39\\"Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)4 core 6 sq mm |
| 54 | 90.6.5.11\\"Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm |
| 55 | OD207534/2025-2026\\"SKFOD_ Supply and fixing SINTEX Box (300mmx200mmx105mm) or nearest size including connector,MCB Rail and neutral links for giving connections including all accessories complete as required |
| 56 | 90.11.1.16\\"Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 57 | 2.10.1\\"Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required. Single pole |
| 58 | 2.10.4\\"Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required. Triple pole |
| 59 | 2.13.2\\"Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 60 | 2.15.3\\"Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 61 | 5.1\\"Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 62 | 90.16.1.3 - Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required3.15 mm copper conductor ( 10SWG) |
| 63 | 90.16.1.10\\"Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.25 mm GI conductor (10 SWG) |
| 64 | 9.1.33\\"Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.4 X 16 sq. mm (28mm) |
| 65 | OD207542/2025-2026\\"Supplying and making end termination with brass compression gland and aluminum lugs for followingsize of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required.4 X 6 sq. mm Please Enable Macros to View BoQ information |