| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group A |
| 3 | Group B |
| 4 | Rewiring for light point/ fan point/ exhaust fan point/call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 5 | Group A |
| 6 | Group B |
| 7 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. |
| 8 | 1 or 2 Module (75mmX75mm) |
| 9 | 3 Module (100mmX75mm) |
| 10 | 4 Module (125mmX75mm) |
| 11 | 6 Module (200mmX75mm) |
| 12 | 8 Module (125mmX125mm) |
| 13 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 14 | 5/6 A switch |
| 15 | 15/16 A switch |
| 16 | 3 pin 5/6 A socket outlet |
| 17 | 6 pin 15/16 A socket outlet |
| 18 | Bell push |
| 19 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor , single core cable in the existing surface / recessed steel/ PVC conduit as required. |
| 20 | 3 x 1.5 sq. mm |
| 21 | 3 x 4 sq. mm |
| 22 | 3 x 6 sq. mm |
| 23 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 24 | 20 mm |
| 25 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 26 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 27 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 28 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. complete as required. |
| 29 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. complete as required. |
| 30 | Single pole |
| 31 | Supplying and fixing following MCB, 240 volts, 'C' series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and Commissioning etc. as required. |
| 32 | 63 amps, DOUBLE POLE |
| 33 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. complete as required. |
| 34 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. complete as required. |
| 35 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 36 | 18- 22 Watt (4feet) |
| 37 | 18-22 WATT (2 feet) |
| 38 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per |
| 39 | LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching)<5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 40 | 90 watt |
| 41 | Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirementdeg, suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 42 | 150 watt |
| 43 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, Earth Leakage Circuit Breaker (ELCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. complete as required. |
| 44 | 32 amps |
| 45 | SITC of Fancy wall bracket fitting with retrofit LED bulb 7-9 watt complete with all accessories i/c LED bulb etc. directly on wall i/c connections with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and earthing etc as required. (Note:- Contractor shall submit 5 Years gurantee certificate of respective manufacturer along with the fitting). (Sample Appoved by Engineer-in-charge before installation at site). |
| 46 | Supplying, Installation & Testing Commissoining of 1200mm sweep 3 star Rating Electric ceiling fan capacitor type with double ball bearing complete with capacitor, 300mm down road, canopies, shackles, three number blade & suitable for operation on 230 volts 50 Hz, single phase A.C. supply etc Complete as reqd. |
| 47 | Supplying, Installation, Testing and Commissioning of 200 mm sweep fresh air fan working on 230 +/- 10 V single phase 50 Hz Frequency complete with shutter in existing hole of suitable size making good the same i/c connections, interconnections etc. complete as reqd. |
| 48 | Supplying, Installation, Testing and Commissioning of 300 mm Sweep 900 RPM Heavy Duty ISI Marked Exhaust fan with louvers & shutters in the existing opening, including making good the same, connection, testing, commissioning etc. as reqd. |
| 49 | Supplying laying and fixing of one number PVC insulated and PVC sheathed / XLPE aluminium power cable of 1.1 kV grade of following size on existing DWC Pipe etc as required |
| 50 | 3 x 10 sqmm |
| 51 | Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching)<3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \\"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector |
| 52 | 12 -15 watt |
| 53 | S.I.T.C of 6-10 W LED bulkhead fitting made out of CRCA sheet duly power coated/Cast Aluminium body, confirming to IP66, suitable for operation on 240 V, 50 Hz AC Supply having power factor ≥ 0.90, complete i/c making connection, testing and comissioining etc complete as reqd. (Note:- Contractor shall submit 5 Years gurantee certificate of respective manufacturer along with the fitting). |
| 54 | S.I.T.C of following LED Post Top Lantern fitting made out of CRCA sheet, duly powder coated /Aluminium body, confirming to IP - 66, suitable for operation on 150 V to 270 V,(5500 to 6500K), 50 Hz AC Supply, having power factor ≥ 0.95, CRI > 80, Luminaries efficacy ≥ 80 lumen/watt , Driver efficiency > 85%, 10 kv surge protection, L-70 Life 50,000 burning hours. complete i/c dismentaling of existing fitting if any, connection, etc complete as reqd. (Note:- Contractor shall submit 5 Years gurantee certificate of respective manufacturer along with the fitting). |
| 55 | 35 watt |
| 56 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 57 | 16 way, Double door |
| 58 | Supplying and Drawing i/c connections & interconnections of following sizes of PVC Insulated and PVC Round Sheathed Multi Core Flexible Aluminium Conductor Heavy Duty Industrial Cables for Voltage Grade 1100 Volts as per IS: 694:2010 for interconnection from window to fitting of street light pole and high mast pole height of upto 30 mtrs.etc complete as reqd. |
| 59 | 3 x 4 sq.mm |
| 60 | Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming and making good the same etc. complete as per direction of Engineer-incharge. |
| 61 | Credit for old dismantle items i/c labour for dismantle |
| 62 | Assorted size old MCCB |
| 63 | PVC insulated copper wires (upto 6 sq.mm) |
| 64 | Old ceiling fans/Exhaust fan / Fresh air fan |
| 65 | Old switches/sockets |
| 66 | Old assorted size Aluminum cable |
| 67 | post of lantern / street light / flood light |
| 68 | bulkhead |
| 69 | down lighter |
| 70 | Old assorted size LED Fixtures Please Enable Macros to View BoQ information |