| 1 | Installation of Deep Tube Well (Size 200mm X 150mm) by DTH Rig Boring 8.1.1 Preparation of site for placement of the drilling rig including excavation of mud pit, circulation drain, collection chamber etc. all complete as directed. |
| 2 | 8.1.2 Movement of Rig from the Divisional Head Quarter to the drilling site including cost of P.O.L. all complete as directed. |
| 3 | 8.1.3 Transportation of all ancillary equipments, camp materials, welding set, rig accessories etc. from Divisional Head Quarter to worksite to and fro including cost of P.O.L. all complete as directed.(a) Upto 100.00 Km distance from Divisional H.Q. |
| 4 | 8.1.4 Transportation of all store materials like pipes, strainer, cone, socket, clamp, bentonite etc. from Divisional Head Quarter to worksite to and fro including cost of P.O.L. all complete as directed.(a) Upto 100.00 Km distance from Divisional H.Q. |
| 5 | 8.1.5 Transportation of air compressor from the Divisional Head Quarter to the drilling site with all accessories including cost of P.O.L. all complete as directed.(a) Upto 100.00 Km distance from Divisional H.Q. |
| 6 | 8.1.6 Transportation of P.O.L. all complete as directed. |
| 7 | 8.1.7 Construction of temporary accommodation and low cost sanitary facility for drilling staff including cost of camp materials viz. cots, tables, chairs, utensils, dresses, safety helmets etc. and dismantling the accommodation after completion of the work all complete as directed. |
| 8 | 8.1.8 Providing water supply facilities at drilling site all complete as directed.By installing 1 Nos. of Singur hand pump |
| 9 | 8.3.1 Drilling with drill bit in overburden portion of soil formation including collection of soil sample at every 3.0 m depth wherever there is a change of strata in sample boxes with distinguishing marks upto the depth of rock formation and with drawing the drill bit for lowering casing as directed with 245mm to 300 mmm dia drill bit |
| 10 | 8.3.2 Casing / sinking / lowering of 200 mm dia MS pipe including cost of pipe and labour charge for casing, welding of joint by welding machine and sinking by drilling rig in portion all complete as directed by department. |
| 11 | 8.3.3 Drilling with drilling rig using D.T.H. in all kinds of rock formation including collection of sample at every 3.0 m depth of boring or wherever there is a change of strata in sample boxes with distinguishing marks upto a required depth of boring along with breaking rock fracture for desired discharge, withdrawing drilling rod and finishing the borehole by ramming upto a reqired dia upto the bottom and washing the well as per direction of the department all complete including testing of yield and drawdown of SWL of the DTW in presence of Engineer / incharge with submission of all report and lithology of the well as directed by the department. |
| 12 | NS Casing / sinking / lowering of 150 mm dia MS pipe including cost of pipe and labour charge for casing, welding of joint by welding machine and sinking by drilling rig in portion all complete as directed by department (As the stone is loose in nature) |
| 13 | Laying ,fitting,fixing,testing & commissioning of Raw water pumping main from DTW to Pressure filter6.2.1 G.I. Socket (g) 65mm |
| 14 | 6.2.2 G.I. Union Socket (g) 65mm |
| 15 | 6.2.3 G.I. Threaded Flange (g) 65mm |
| 16 | 6.2.4 G.I. Bend (g) 65mm |
| 17 | 6.2.14 G.I. NIPPLE (50mm long) (g) 65mm |
| 18 | 6.2.16 G.I. NIPPLE (100mm long) (g) 65mm |
| 19 | 6.2.19 G.I. NIPPLE (175mm long)(g) 65mm |
| 20 | 6.2.21 G.I. NIPPLE (225mm long) (g) 65mm |
| 21 | 6.8.3 M.S. CLAMP/BOLT/ NUT/ WASHER |
| 22 | 6.8.4 Rubber Insertion Sheet (a) 3 mm thick |
| 23 | (B) Labour Payment (including cost of pipe)18.12 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.18.12.7 65 mm dia nominal bore |
| 24 | 14 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 14.3 65mm dia |
| 25 | 12 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :12.3 65mm dia |
| 26 | 18.34 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :18.34.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 27 | Supplying,fitting,fixing,testing & commissioning of 3 Phase electric driven Raw Water Submersible pumpelectric driven pressurisation pump (Jockey pump) 4309 180 lpm at 88 m Head |
| 28 | 10.7.1 Labour charge for installation of Submersible pump set including supplying, carrying, fitting and fixing suction pipes of required length with G.I. Specials such as socket, bend, G.I. flange, M.S. Clamps and necessary jointing materials including commissioning and testing the pump but excluding only the cost of column pipe all complete as required as directed (upto 30.00m depth) (c) (i) 50 mm dia column pipe upto 30 m depth |
| 29 | 10.7.1 Labour charge for installation of Submersible pump set including supplying, carrying, fitting and fixing suction pipes of required length with G.I. Specials such as socket, bend, G.I. flange, M.S. Clamps and necessary jointing materials including commissioning and testing the pump but excluding only the cost of column pipe all complete as required as directed (upto 30.00m depth) (c) (ii) 50 mm dia column pipe beyond 30.00m depth extra charges. |
| 30 | 8641 Chlorinated Polyvinyl - chloride (CPVC) pipe 50 mm nominal dia |
| 31 | 17.5.1 Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of cross linkable ethylene propylene rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH (Service Cable) |
| 32 | 6.8.14 Supply & fitting of PVC 3 CORE FLAT SUBMERSIBLE CABLES TO IS:694/1990(e) 10sqmm (80/0.40) |
| 33 | 17.1.11 Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required |
| 34 | 6.8.13 Supply of Steel Wire Rope Lube (IS:2266) |
| 35 | NS Extension of 3 phase AB Cable for load extension |
| 36 | Providing,supplying,fitting,fixing of Iron removal pressure filter of 10000 LPHNS Supplying, fitting, fixing in position Multimedia pressure filter consisting of FRP vessel of Gratisco / TATA make filled with Anthracite, Kotax light media, White Sand, Treated Sand, Gravel, MnO2 filter media along with Cotton Candle to remove iron effectively at a max. pressure of 10 kg/sqcm and max flow rate of 10000 lph with back wash facility including all fittings, valves, Tee, Elbow etc. complete in all respect as directed including all taxes. |
| 37 | Construction of UGR of size 30,000 ltr.capacity 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil. |
| 38 | 11.1 Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks:11.1.2 1:6 (1cement : 6 coarse sand) |
| 39 | 4.20A Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources and using recycled concrete aggregate (RCA) as coarse aggregate and fine aggregate within the permissible utilization, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete.4.20A.1 All works upto plinth level4.20A.1.1 Concrete of M10 grade with minimum cement content of 220 kg /cum. |
| 40 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.4 Hot rolled deformed bars |
| 41 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.1 Mild steel and Medium Tensile steel bars |
| 42 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.1 Foundations, footings, bases of columns, etc. for mass concrete |
| 43 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts |
| 44 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 45 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.7 Stairs, (excluding landings) except spiral-staircases |
| 46 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.20 Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick |
| 47 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.13 Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards |
| 48 | 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 49 | 5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 50 | 5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 51 | 9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc. |
| 52 | 13.1 12 mm cement plaster of mix :13.1.1 1:4 (1 cement: 4 fine sand) |
| 53 | 13.26 Providing and applying plaster of paris putty of 2mm thickness obver plastered surface to prepare the surface even and smooth complete. |
| 54 | 13.43 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :13.43.1 Water thinnable cement primer |
| 55 | 13.46 Finishing walls with Acrylic Smooth exterior paint of required shade :13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 56 | 4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 57 | Supplying,fitting,fixing ,testing & commissioning of 3 phase electric driven clear water centrifugal pump 3 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)Horizontal type,multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50Hz AC supply with IP55 class of protection for enclosure, horizontal footmounted typewithClass-'F' insulation, conforming to IS : 325.M.S.fabricatedCommonbaseplate,coupling,couplingguard, foundation bolts etc. as required.3.2 180 lpm at 70 m Head |
| 58 | Construction of protection fencing around the DTW with M.S GrillNS Construction of protection fencing around the Transformer with providing, fitting and fixing of M.S. Grill of required pattern fitted In RCC post with necessary' earth work excavation, PCC works above brick solling and 65 mm thick CC floor all complete as directed & specified. |
| 59 | Laying,fitting,fixing,testing & commissioning of Distribution network9.1.1 Earth work in excavation for foundation trenches including refilling the quantity as necessary after completion of work of pipe line dressing, ramming, watering etc. and removal of surplus earth with 50m lead and lift up to 1.50m all complete as directed including bailing out water where necessary.(b) Blastic land, tillah soil, hard soil, soil mixed with moram gravel and boulders upto one man size |
| 60 | 18.12 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.18.12.7 65 mm dia nominal bore |
| 61 | 18.12 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.18.12.6 50 mm dia nominal bore |
| 62 | 18.12 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.18.12.5 40 mm dia nominal bore |
| 63 | 18.12 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.18.12.4 32 mm dia nominal bore |
| 64 | 18.13 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :18.13.1 25 to 40 mm nominal bore |
| 65 | 18.13 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :18.13.2 50 to 80 mm nominal bore |
| 66 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.3A 1:2:4 (1 cement : 2 coarse sand (zone-III) including manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 25% : 4 graded stone aggregate 20 mm nominal size Recycled Concrete Aggregate (RCA) upto 25%) |
| 67 | 7.3 DRAIN AND SOAKPIT :7.3.1 Construction of drain with cement concrete works in proportion 1:2:4 in slope 1:50 with a base layer of concrete of proportion 1:4:8 as per respective approved drawings including necessary earth work and refilling after completion of work all complete as directed. |
| 68 | 12 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :12.1 40mm dia |
| 69 | 12 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :12.2 50 mm dia |
| 70 | 12 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :12.3 65mm dia |
| 71 | 18.34 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :18.34.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 72 | NS Providing Functional Household Tap Connection from distribution network Please Enable Macros to View BoQ information |