| 1 | Clearing and grubbing of road land including up rooting rank vegetation grass,bush, shurbs saplings and trees of girth upto 300mm removal of stumps of trees cut earlier and disposal of unseviceable materials & stacking of serviceable material to be used or auctioned, upto a lead of 1000m including removal & disposal of top organic soil not exceeding 150mm in thickness.(I) By manual Means- (a) In area of non thorny jungle |
| 2 | Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202(b) Above 600 mm to 900 mm dia Hume pipe |
| 3 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202.ii) By Mechanical MeansA) Cement Concrete |
| 4 | Scarifying Existing Bituminous Surface to a Depth of 150 mm by Mechanical MeansScarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3.0m and lead upto 1000 m as per Technical Specification Clause 301.4. |
| 5 | Construction of embankment with material obtained from borrow pits, construction of embankment with approved materials obtained from borrow pits with a lift up to 1.5m, transporating to site, spreading, grading to required slope and compacting to meet required of tables 300.1 and 300.2 with a lead upto 1000m as per technical specification clause. (a) Private Land |
| 6 | Construction of sub-grade and earthen shoulders construction of sub grade and earthen shoulders with approved materials obtained from borrow pits with all lifts and leads, transporating to site, spreading, grading to required slope and compacting to meet required of table 300.2 with lead upto 1000m as per technical specification clause.(a) Private Land |
| 7 | Excavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections. |
| 8 | (A) By mix in place Method -Construction of granular sub base by providing well graded material, spreading in uniform layers with motor grader on prepare surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification clause 401. (ii) For Grading Material (Gr-II) |
| 9 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying inuniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. |
| 10 | Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 |
| 11 | Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503. |
| 12 | Dense Graded Bituminous Macadam (Providing and laying dense bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix and filler transporting the hot miox to work site,laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no. 507. complete in all respect. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant )( Including cost of testing of materials at site and laboratory as directed by the deptt.)for Grading II (19 mm nominal size) |
| 13 | Bituminous Concrete: Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no.509. complete in all respect. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant )( Including cost of testing of materials at site and laboratory as directed by the deptt.) for Grading II (13 mm nominal size) |
| 14 | Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per technical specification clause 1504 complete including carriage.(i) Including Edge Restrain/Edge Block |
| 15 | Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. (iii) 600mm equilateral triangle |
| 16 | Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. (iv) 600mm circular |
| 17 | Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. (v) 800mm x 600mm rectangular |
| 18 | Providing Hump type speed breaker DBM |
| 19 | Providing Hump type speed breaker BC |
| 20 | Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 |
| 21 | Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 ii) Ordinary Kilometer Stone (Precast) |
| 22 | Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 iii) 200 m stone (precast) |
| 23 | Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specifications(80% of the length is considered) |
| 24 | Providing reflective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H’s fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance. |
| 25 | RCC Guard Post: Supplying, fitting and fixing RCC guard post 150cm long erected 75cm above the ground and 75cm below the ground with M-15 grade (nominal mix 1:2:4 with broken stone aggregate up to 20mm size) of cement concrete and required reinforcement tied in position with annealed black wire including centering, moulding the top, curing including painting concrete surfaces in 23cm strips upto 0.75m from the top alternately in black and white and having 2 nos. reflectiveband of desired shade etc. complete as per design and as directed.(b) 15 cm dia. RCC guard post with reinforcement of 4nos. 12mm dia TMT main steel bars and 6mm TMT/ MS stirrups at 15cm c/c. |
| 26 | Providing Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125 mm x 125 mm ), 90 mm height (from bottom of shank to the top of stud) with detachable battery, m6 LEDs- three on each side for Bi-directional studs / 3LEDs on one side for uni directional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance fro one year from the date of installation of stud on road- (installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician ).a) Bi-directional Stud |
| 27 | Planting of Trees and their Maintenance for three Year (Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge mannure, planting the saplings, backfilling the trenches, watering , fixing the tree guatrd and maintaining the plants for three year. |
| 28 | 2 m x 2 M Box CulvertEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. V Marshy soil |
| 29 | Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 I. Sand filling |
| 30 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 B. With natural Gravel III. P.C.C Grade M20 Nominal mix (1:2:4) |
| 31 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 B. With natural Gravel IV. R.C.C Grade M20 |
| 32 | Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in foundation complete as per drawings and technical specifications Clauses 1000 and 1202 |
| 33 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 B. With Natural Gravel IV. RCC Grade M 25 i) For height upto 5 m |
| 34 | Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 |
| 35 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 |
| 36 | Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 I. Granular material |
| 37 | Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 A. With crushed stone |
| 38 | Drainage spouts complete as per drawing and technical specifications Clause 1209 |
| 39 | Providing and laying curtain walls complete as per drawing and technical specification Clause 1304 iii. Cement concrete grade M 10 |
| 40 | Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less then 25 kg beyond curtain wall |
| 41 | 4.00 M Slab CulvertE/Work in excavation for structures as per drawing and technical specification, clause 305-1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m., dressing sides and bottom and backfilling in trenches with excavated suitable material.1. Ordinary soil |
| 42 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawing and technical specification Clause 802, 803, 1202 & 1203.A. With Crushed stone.I. PCC grade M10Nominal mix 1:3:6 |
| 43 | Plain/reinforced cement concrete in Sub Structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204. A. With Crushed Stone I. P.C.C grade M 15I. Nominal mix (1:2.5:5) |
| 44 | Providing and laying reinforced cement concrete in superstructure as per drawing and technical specification Clause 800, 1205.4 and 1205.5.A. With crushed stoneI. RCC grade M 20(iii) For design mix RCC M20a) Height upto 5.0 m. |
| 45 | Providing and laying cement concrete wearing course M30 grade including reinforcement complete as per drawing and Technical Specification Clause 800 and 1206.3.A. With crushed stone |
| 46 | Providing weep wholes in brick masonry/ stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100mm dia AC pipe extending through the full width of the structures with slope of 1(V) : 20(H) towards drawing face complete as per drawing and Technical Specification Clause 614, 709, 1204.3.7. |
| 47 | Drainage spouts complete as per drawing and Technical Specification Clause 1209. |
| 48 | Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8 |
| 49 | Supplying, fitting and placing TMT bar reinforcement (Fe 500) in sub structure complete as per drawing and Technical Specification Clauses 1002, 1005, 1010 & 1202. |
| 50 | Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 |
| 51 | Providing and laying of boulder apron laid in wire crates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm mesh (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specifications Clause 1301 |
| 52 | Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302(I) Stone/ Boulder |
| 53 | Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302 |
| 54 | RCC DrainEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.I. Ordinary soilUpto 3 m depth |
| 55 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203P.C.C grade M 10Nominal mix 1:3:6 |
| 56 | Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (FromPrimary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses1002, 1005, 1010 & 1202 |
| 57 | Providing concrete for plain / reinforced concrete in substructure complete as per drawings and technical specifications Clauses 802, 804, 805, 806, 1202 & 1204PCC Grade M 20Nominial mix (1:2:4) |
| 58 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 |
| 59 | Providing,fitting & fixing in position of Ornamental Iron Grill at Footpath as directed by engineer in charge. |
| 60 | Utility shifting Please Enable Macros to View BoQ information |