| 1 | DSR Item No. 2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 2 | 100 A,30KA,FPMCCB |
| 3 | DSR Item No. 8.16.3LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy ≥120 and <135 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, (As per Complete Item No. 7 of the DNIT). |
| 4 | 100 Watt |
| 5 | 150 Watt |
| 6 | DSR ITEM NO. LED 8.9.5Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, (As per Complete Item No. 3 of the DNIT). |
| 7 | 18-22 watt |
| 8 | DSR ITEM NO. 8.7LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, (As per Complete Item No. 7 of the DNIT). |
| 9 | 36 watt |
| 10 | DSR Item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 11 | Single pole |
| 12 | Double pole |
| 13 | Supply and laying of XLPE insulated PVC sheathed Aluminium conductor cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid direct on surface with the help of M.S. clamp of suitable thickness. (As per Complete Item No. 6 of the DNIT). |
| 14 | 10 Sq.mm. 2 Core XLPE Armoured Aluminium conductor cable |
| 15 | 50 Sq.mm. 3.5 Core XLPE Armoured Aluminium conductor cable |
| 16 | 95 Sq.mm. 3.5 Core XLPE Armoured Aluminium conductor cable |
| 17 | Supply & laying of PVC copper wire 1.5mm sq. 3 core round sheathed wire on existing surface with suitable clamps/ hanger etc. including making connection and petty material etc. as required to complete the job to the entire satisfaction of Engineer-in-charge. The copper wire should be of Polycab/ L&T/ Havells/ Finolex/ R.R. Kables make only. |
| 18 | Supply & laying of PVC copper wire 2.5mm sq. 3 core round sheathed wire on existing surface with suitable clamps/ hanger etc. including making connection and petty material etc. as required to complete the job to the entire satisfaction of Engineer-in-charge. The copper wire should be of Polycab/ L&T/ Havells/ Finolex/ R.R. Kables make only. |
| 19 | Providing and fixing MCB 4 Pole 63 AMPS, 415 volt ‘C’ curve 10 KA breaking capacity in the existing enclosure as per site requirement. The job includes making connection with suitable size with copper wire to the entire satisfaction of engineer in charge. The MCB should be L&T (Exora)/ Legrand (DX3)/Schneider(Acti-9)/ ABB (SB200M)/ Siemens(Betagard)/ Hager(H3) make only. |
| 20 | Supply & erection of Cabin Fan 16\\" sweep (metal body) oscillating type complete with aluminium blades & regulator. The fan should have regulator switch for speed regulation. (As per Complete Item No. 10 of the DNIT). |
| 21 | DSR ITEM NO. 9.2Brush Less Direct Current (BLDC) MotorSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, (As per Complete Item No. 11 of the DNIT). |
| 22 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 23 | Supply installation testing and commissioning of 2X12 watt wall mounted Industrial Double Beam emergency LED light with exit sign board. The fitting should have CRCA steel housing, 50000 burning hours, (As per Complete Item No. 12 of the DNIT). Please Enable Macros to View BoQ information |