| 1 | Package.No.AP26PVT027-L036-Road from Palakonda PR Road to Pulagondi in G.Madugula (M) in ASR District, Est.Cost:Rs.80.00 Lakhs |
| 2 | Road Part |
| 3 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201 MORD . including contractors profit & Over head charges, but excluding GST and Seigniorage charges etc., complete. |
| 4 | Construction of embankment with approved material obtained from borrow pits with all lifts, transporting to site, spreading, grading to required slope and compacting with vibratory roller 80-100 KN to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 MORD including contractors profit & Over head charges, but excluding GST and Seigniorage charges etc., complete.., complete. |
| 5 | Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain (not exceeding 0.6 m depth) and foundation of other structures including breaking clods, ramming, spreading, sectioning, grading compacting with vibratory roller 80-100KN to OMC compaction including to a top width of 7.5m and raising to required height complete etc.as per requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 MORD including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete. |
| 6 | Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with initial lift of 3 mts and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5 MORD / 301 MORTH |
| 7 | Construction of granular sub-base by providing well graded material(Table 400.1-A) with Grading III Material(HBG M/C +Stone dust) CBR Value not less than 20 and PI Value less than 6 spreading in uniform layers with Tractor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with Vibratory Roller to achieve the desired density, complete as per Technical Specification Clause 401 MORD including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete. |
| 8 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with Vibratory Roller 80-100 kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406 MORD, including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete |
| 9 | Providing and applying primer coat with bitumen emulsion (CSS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 MORD (for use on Wet mix macadam & WBM) ,including contractors profit & Over head charges, but excluding GST etc., complete for Prime Coat |
| 10 | Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503 MORD, including contractors profit & Over head charges, but excluding GST etc., complete for Tack Coat |
| 11 | Providing, laying and rolling of close-graded premix surfacing (Mix seal surfacing) material of 20 mm thickness composed of 13.2 mm to 0.09 mm (Type-B) aggregates as per Table 500.15 of MORD using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable Hot Mix plant (By mechanical means), laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 507 MORD'2014, including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete |
| 12 | Construction of un-reinforced, panneled cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, as per design, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, wedges, steel plates including levelling the formwork etc complete as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation, admixtures as approved, curing of concrete slab for 14-days, using curing compound (where specified) and water and contraction sawn joint groove (using daimond studded nblades) 3 to 5 mm wide and 1/3rd to 1/4th depth of the slab + or - 5mm or .Thecontraction joint shall be cut as soon as the concrete as under goneinitial hardening and as hard enogh to take up the load of joint swaing machine with out causing damage to the slab. The joint ceilling compound shall not be poured bitumen type having flexibility, resistaance to age hardening and durability of the sealant shall be in accordance with BS 5212 (part-2) with all leads and lifts and coat and conveyance of all materials for 100 thickness for forming the panels of 0.75 X 0.75 mts size as per drawing and Technical Specification Clause 1501 including contractors profit & Over head charges,but excluding Seig Charges, & GST etc,. Complete. |
| 13 | Construction of Shoulders by providing selected earth having minimum CBR of 10%, MDD not less than 1.85 g/cc with LL & PI not more than 40% and 20 respectively and spreading in uniform layers with tractor grader on prepared surface, and compacted at OMC with vibratory roller 80-100 kN to meet requirement of Table 300.2 with as per Technical Specification Clause 303 & 407 MORD, by using machinery including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete. |
| 14 | Road Furniture |
| 15 | Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 MORD / 804 MORTH including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete for (precast)Ordinary KM Stone |
| 16 | Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 MORD / 804 MORTH including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete for (precast)200 M Stone |
| 17 | Providing & fixing of typical PMGSY informatory sign board with LOGO as per MORD secifications and drawing Consisting of Three boards made of encapsulated lens type Retro reflective sheeting as per IRC 67 fixed over Alluminium Composite Material of 4mm thickness fixed on a frame of 25x25x5mm MS angle alround edges and MS flats 25x5mm in the middle duly welding he lower plate and middle plate to 2 nos of verticle posts 75x75 x6mm MS square hallow section of 2.80m length welded with 200x200x5mm thick MS base plate at bottom duly embedded in CC M20 grade blocks of 450x450x600mm, 600mm below ground level and the top most diamond plate welded to middle plate by 47x47 X6mms MS square hallow section tube duly supported by 47x47x6mm MS square tube in between two vertical posts including lettering , colour,band, diagrams, specifications etc., complete as per MORD specifications and paining to all sections of framed posts,tubes and sheetwith primer and two coats of epoxy paint in required shade and colour as per drawing clause 1701 and annexure 1700.1 of MORD including cost and conveyance and other incidental charges ,contractors profit & Over head charges, but excluding GST and seigniorage etc., complete for finshed item of work |
| 18 | Providing and fixing of Maintenance information board as per MoRD specifications and drawings made of encapsulated lens type Retro reflective sheeting as per IRC:67 fixed over Alluminium Composite Material of 4mm thickness and size of 900 x 1500 mm fixed on a frame of 25X25X6mm thick MS angles alround edges and MS flats 25x5mm in the middle and welded to 75 x 5 mm size MS flat plates on back and welded to 75 x 75 x6mm MS Square hollow section of height 3.00m length welded with base MS plate of 300x300x5mm thick base MS plate at bottom duly embedded in to cement concrete M20 grade of size 600 x 600 x 750 mm, 750 mm below ground level including lettering , colour,band, diagrams, specifications etc., complete as per MORD specifications and paining to all sections of framed posts,tubes and sheet with primer and two coats of epoxy paint in required shade and colour as per drawing clause 1701 and annexure 1700.1 of MORD including cost and conveyance and other incidental charges ,contractors profit & Over head charges, but excluding GST and seigniorage etc., complete for finshed item of work |
| 19 | Providing and fixing of Citizen information board as per MoRD specifications and drawings consists of two boards made of encapsulated lens type Retro reflective sheeting as per IRC 67 fixed over Alluminium Composite Material of 4mm thickness and 900/750mm size fixed on a frame of 25x25x5mm thick MS angle alround edges and 25x5mm thick MS flats in the middle welded to 75 x 5 mm size MS Flat plates on back and welded to 75x75x6mm MS square hallow sections of length 3.05m welded with 300x300x5mm MS Base plate at bottom duly embedded in cement concrete M20 grade of size 600x600x750 mm, 750mm below ground level including lettering , colour,band, diagrams, specifications etc., complete as per MORD specifications and paining to all sections of framed posts,tubes and sheet with primer and two coats of epoxy paint in required shade and colour as per drawing clause 1701 and annexure 1700.1 of MORD including cost and conveyance and other incidental charges ,contractors profit & Over head charges, but excluding GST and seigniorage etc., complete for finshed item of work |
| 20 | Providing & fixing of typical PMGSY LOGO Board (every 2Km) as per MORD secifications and drawing consists of two boards made of encapsulated lens type Retro reflective sheeting as per IRC fixed over Alluminium Composite Material of 4mm thickness fixed on a 25x25x5mm size MS frame alround edges and 25mmx5mm size Ms flats in middle duly welding the top and bottom plates 1 No of 75x75 x6mm MS Square hallow section post of 2.95 m height welded with 200x200x5mmthick MS base plate of at bottom duly embedded in CC M 20 grade block of 450x450x600mm, 600mm below ground level including lettering , colour,band, diagrams, specifications etc., complete as per MORD specifications and paining to all sections of framed posts,tubes and sheet with primer and two coats of epoxy paint in required shade and colour as per drawing clause 1701 and annexure 1700.1 of MORD including cost and conveyance and other incidental charges ,contractors profit & Over head charges, but excluding GST and seigniorage etc., complete for finshed item of work |
| 21 | Providing and fixing of retro-reflectorised cautionary,mandatory and informatory sign boards as per MoRD specifications and drawings made of encapsulated lens type reflective sheeting as per IRC:67 fixed over aluminium sheeting 4 mm thick fixed on 25x25x5mm size MS angles alround and 25mm x5mm size MS flats in middle supported on 75x75 x6mm MS angle section post welded with 50x50x5 mm MS angle hold fast at bottom firmly fixed in the ground by means of properly designed foundation with M 20 cement concrete 450 x450x600 mm,600 mm below ground level including lettering , colour,band, diagrams, specifications etc., complete as per MORD specifications and paining to all sections of framed posts,tubes and sheet with primer and two coats of epoxy paint in required shade and colour as per drawing clause 1701 and annexure 1700.1 of MORD including cost and conveyance and other incidental charges ,contractors profit & Over head charges, but excluding GST and seigniorage for Triangular 600x600 |
| 22 | Providing and erecting direction and place identification retro-refectorised sign as per MoRD specifications and drawings made of encapsulated lens type refective type sheeting as per IRC 67 fixed over aluiminium sheeting,4mm thick with area not exceeding 0.90 sqm board fixed on 25x25x5mm size MS frame alround and 25mm x5mm size MS flat in the middle supported on 75x75 x6mm MS angle section posts welded with 50x50x5 mm MS hold fast at bottom, firmly fixed in the ground by means of properly designed foundation with M 20 cement concrete 450 x450x600 mm,600 mm below ground level including lettering , colour,band, diagrams, specifications etc., complete as per MORD specifications and paining to all sections of framed posts,tubes and sheet with primer and two coats of epoxy paint in required shade and colour as per drawing clause 1701 and annexure 1700.1 of MORD including cost and conveyance and other incidental charges ,contractors profit & Over head charges, but excluding GST and seigniorage etc., complete for finshed item of work |
| 23 | Construction of RCC guide posts of 250 mm dia M 20 grade cast-in-situ with 20 mm nominal size aggregate (HBG), true to line and grade, tolerance of vertical RCC posts not to exceed 1 in 500 as per drawing and Technical Specification Clause 1608.2 including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete |
| 24 | Const. of 1Vent-1000 mm pipe Culvert-1No |
| 25 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH, including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete- For Foundations |
| 26 | Filling in foundation trenches / Pipe bedding with Sand as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH ,including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete. |
| 27 | Providing concrete for plain concrete M 10 grade in open foundations using 40 mm nominal size hard stone aggregate (HBG), mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 MORD and 1500, 1700 & 2100 MORTH ,including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete For levelling course |
| 28 | Plain cement concrete M 15 grade using 40,20 & 10mm metal (HBG) mechanically mixed in foundation complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1203 MORD and 1500, 1700 & 2200 MORTH ,including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete- for Head walls of pipe culverts & footings of slab culverts For Head walls and Parapet |
| 29 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head wall and parapets. Tech Specification Clause 1101.6 MORD ,including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete - For Pipe Culverts with 1000mm dia NP3 pipes |
| 30 | Const. of 1V-3mts span slab culvert |
| 31 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH, including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete- For Foundations |
| 32 | Providing concrete for plain concrete M 10 grade in open foundations using 40 mm nominal size hard stone aggregate (HBG), mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 MORD and 1500, 1700 & 2100 MORTH ,including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete For levelling course |
| 33 | Plain cement concrete M 15 grade using 40,20 & 10mm metal (HBG) mechanically mixed in foundation complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1203 MORD and 1500, 1700 & 2200 MORTH ,including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete |
| 34 | Plain cement concrete M 15 grade using 40,20 & 10mm metal (HBG) mechanically mixed in foundation complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1203 MORD and 1500, 1700 & 2200 MORTH ,including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete-for Abutments |
| 35 | Providing and laying reinforced cement concrete M25 grade (Design Mix) using 20 & 10mm metal (HBG) mechanically mixed in superstructure as per drawing and technical specifications Clauses 800, 1401.4.1 and 1401.4.2 MORD / Sections 1500, 1600 & 1700 MORTH ,including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete upto 5m height. - For Bed Blocks |
| 36 | Providing and laying reinforced cement concrete M25 grade (Design Mix) using 20 & 10mm metal (HBG) mechanically mixed in superstructure as per drawing and technical specifications Clauses 800, 1401.4.1 and 1401.4.2 MORD / Sections 1500, 1600 & 1700 MORTH ,including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete upto 5m height. - For Super Structure (Deck slab) |
| 37 | Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 MORD / 710.14 of IRC, 78 & 2200 MORTH including contractors profit & Over head charges but excluding Seigonarage charges & GST |
| 38 | Supplying, fitting and placing HYSD bar reinforcement (Fe 500) in substructure complete as per drawings and technical specification Clauses 1001 & 1206 MORD / Sections 1600 & 2200 MORTH for Bars below 36 mm dia including over laps and wastage, where they are not welded ,including contractors profit & Over head charges, but excluding GST etc., complete- For Sub Structures - For Sub Structures |
| 39 | Supplying, fitting and placing HYSD bar reinforcement (Fe 500) in substructure complete as per drawings and technical specification Clauses 1001 & 1206 MORD / Sections 1600 & 2200 MORTH for Bars below 36 mm dia including over laps and wastage, where they are not welded ,including contractors profit & Over head charges, but excluding GST etc., complete- For Sub Structures - For Sub Structures |
| 40 | Providing weep holes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia PVC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1206.6 MORD / 2706 & 2200 MORTH including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete |
| 41 | Construction of RCC guide posts of 250 mm dia M 20 grade cast-in-situ with 20 mm nominal size aggregate (HBG), true to line and grade, tolerance of vertical RCC posts not to exceed 1 in 500 as per drawing and Technical Specification Clause 1608.2 including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete |
| 42 | Const. of 1V-600mm dia pipe culverts |
| 43 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH, including contractors profit & Over head charges, but excluding GST etc., complete- For Foundations |
| 44 | Filling in foundation trenches / Pipe bedding with Sand as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH ,including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete. |
| 45 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head wall and parapets. Tech Specification Clause 1101.6 MORD ,including contractors profit & Over head charges, but excluding GST and seigniorage etc., complete - For Pipe Culverts600mm dia NP3 pipes Please Enable Macros to View BoQ information |