Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Checking, Inspection, maintanance and servicing complete including replacement of unserviceable spare parts of the DG set (comparising of Engine/ Alternator/ Control panel) of the following capacity for smooth functioning complete all as per manufacturers instructions and all as directed by Engg - In - Charge A. (a) Checking of lubricating oil condition (b) Checking engine for oil, water leakage and correcting the same (c) Checking of all the nut bolts of engine and alternator (d) Checking of all belts and adjust the tenson properly (e) Cleaning of air filters (f) Checking and readjusting the valve clearance (g) Change of Oil/Fuel filters and engine oil if necessary (h) Checking of starter motor battery and charger (i) Checking of cooling system and fuel system (j) checking of all power cables and AVR connections and mounting bolt tightnees of alternator (k) checking the function of AVR genaral checks (l) Checking of control panel meters and gadgets functiong (m) Checking of all control and safety wirings B. (a) Checking of flexible coupling of engine and alternator (b) Cleaning of crank case ventilation pipe (c) Checking of injectors and fuel pump (d) Checking of alternator and carbon brushes of following capacity DG sets .Changing/Topping up of best quality engine oil(recomanded by company make) including draining of old burnt oil from DG set and topping with new specified engine oil including unservisible filters(oil,Air,Bypass , Fuel primary and secondary,Water seperator) as per requirement of DG. NOTE (1) Cost of Spares required will be paid and measured separately (2) Servicing/routine check up carried out through authorised service centre of manufacturer (4) Make of spare recommendation by ( Supply Part) |
| 2 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 3 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 4 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 5 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 6 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 7 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 8 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 9 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 10 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 11 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 12 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 13 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 14 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 15 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 16 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 17 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 18 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 19 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 20 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 21 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 22 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 23 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 24 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 25 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 26 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 27 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 28 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 29 | Checking, Inspection, maintanance and servicing complete including replacement of unserviceable spare parts of the DG set (comparising of Engine/ Alternator/ Control panel) of the following capacity for smoth functioning complete all as per manufacturers instructions and all as directed by Engg - In - Charge A. (a) Checking of lubricating oil condition (b) Checking engine for oil, water leakage and correcting the same (c) Checking of all the nut bolts of engine and alternator (d) Checking of all belts and adjust the tenson properly (e) Cleaning of air filters (f) Checking and readjusting the valve clearance (g) Change of Oil/Fuel filters and engine oil if necessary (h) Checking of starter motor battery and charger (i) Checking of cooling system and fuel system (j) checking of all power cables and AVR connections and mounting bolt tightnees of alternator (k) checking the function of AVR genaral checks (l) Checking of control panel meters and gadgets functiong (m) Checking of all control and safety wirings B. (a) Checking of flexible coupling of engine and alternator (b) Cleaning of crank case ventilation pipe (c) Checking of injectors and fuel pump (d) Checking of alternator and carbon brushes of following capacity DG sets .Changing/Topping up of best quality engine oil(recomanded by company make) including draining of old burnt oil from DG set and topping with new specified engine oil including unservisible filters(oil,Air,Bypass , Fuel primary and secondary,Water seperator) as per requirement of DG. NOTE (1) Cost of Spares required will be paid and measured separately (2) Servicing/routine check up carried out through authorised service centre of manufacturer (4) Make of spare recommendation by ( Installation Part) |
| 30 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 31 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 32 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 33 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 34 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 35 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 36 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 37 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 38 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 39 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 40 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 41 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 42 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 43 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 44 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 45 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 46 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 47 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 48 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 49 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 50 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 51 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 52 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 53 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 54 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 55 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 56 | 7.5 KVA DGSet (Kirloskar Make)( Installation Part) |
| 57 | Replacement of Dynamo Assy for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 58 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 59 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 60 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 61 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 62 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 63 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 64 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 65 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 66 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 67 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 68 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 69 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 70 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 71 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 72 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 73 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 74 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 75 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 76 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 77 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 78 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 79 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 80 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 81 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 82 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 83 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 84 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 85 | Repair of Dynamo Assy for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge.( Installation Part) |
| 86 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 87 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 88 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 89 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 90 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 91 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 92 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 93 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 94 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 95 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 96 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 97 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 98 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 99 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 100 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 101 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 102 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 103 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 104 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 105 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 106 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 107 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 108 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 109 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 110 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 111 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 112 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 113 | Supply for M&L for disconnecting the U/S DC alternator of following capacity DG Set, 3 phase any make & type from engine, taking out burnt armature winding aleaning the alternator coil with existing gauge/size of super enamelled copper winding wire, providing new insulation, sleeves, varnishing cotton taping etc reassembling the alternator complete including aligning with engine and testing in all aspects for smooth functioning all as specified and directed by Engineer-in-charge.Re-assembling all the component of the alternator and mounting the same on the existing foundation including welding of alternator foundation plate by electric arc welding ,aligning the alternator with engine and testing on full load as specified in particular specification and as directed by Engr-in-Charge. |
| 114 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 115 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 116 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 117 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 118 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 119 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 120 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 121 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 122 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 123 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 124 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 125 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 126 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 127 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 128 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 129 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 130 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 131 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 132 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 133 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 134 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 135 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 136 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 137 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 138 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 139 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 140 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 141 | Installation of M&L for disconnecting the U/S DC alternator of following capacity DG Set, 3 phase any make & type from engine, taking out burnt armature winding aleaning the alternator coil with existing gauge/size of super enamelled copper winding wire, providing new insulation, sleeves, varnishing cotton taping etc reassembling the alternator complete including aligning with engine and testing in all aspects for smooth functioning all as specified and directed by Engineer-in-charge.Re-assembling all the component of the alternator and mounting the same on the existing foundation including welding of alternator foundation plate by electric arc welding ,aligning the alternator with engine and testing on full load as specified in particular specification and as directed by Engr-in-Charge. |
| 142 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 143 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 144 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 145 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 146 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 147 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 148 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 149 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 150 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 151 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 152 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 153 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 154 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 155 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 156 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 157 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 158 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 159 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 160 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 161 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 162 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 163 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 164 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 165 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 166 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 167 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 168 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 169 | Supply of M&L for taking out burnt winding of exciter of following capaicity of DG sets including re-winding copper wire of super quality, of existing size, No of turns, varnishing, heating complete including testing on full load complete all as specified and directed by Engineer-in-charge. Re-assembling all the component of the alternator and mounting the same on the existing foundation including welding of alternator foundation plate by electric arc welding ,aligning the alternator with engine and testing on full load as specified in particular specification and as directed by Engr-in-Charge.( Supply Part) |
| 170 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 171 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 172 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 173 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 174 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 175 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 176 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 177 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 178 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 179 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 180 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 181 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 182 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 183 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 184 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 185 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 186 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 187 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 188 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 189 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 190 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 191 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 192 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 193 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 194 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 195 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 196 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 197 | Installation of M&L for taking out burnt winding of exciter of following capaicity of DG sets including re-winding copper wire of super quality, of existing size, No of turns, varnishing, heating complete including testing on full load complete all as specified and directed by Engineer-in-charge. Re-assembling all the component of the alternator and mounting the same on the existing foundation including welding of alternator foundation plate by electric arc welding ,aligning the alternator with engine and testing on full load as specified in particular specification and as directed by Engr-in-Charge.( Installation Part) |
| 198 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 199 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 200 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 201 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 202 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 203 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 204 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 205 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 206 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 207 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 208 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 209 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 210 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 211 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 212 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 213 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 214 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 215 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 216 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 217 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 218 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 219 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 220 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 221 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 222 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 223 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 224 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 225 | Supply of Oil seal front, Acc. Drive Seal and rearsuitable side for following Capacity DG Sets make Kirlosker/ cummins/Greaves complete all as specified and directed by Engr-in-Charge.( Supply) |
| 226 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 227 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 228 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 229 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 230 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 231 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 232 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 233 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 234 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 235 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 236 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 237 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 238 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 239 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 240 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 241 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 242 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 243 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 244 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 245 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 246 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 247 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 248 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 249 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 250 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 251 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 252 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 253 | Replacement of Oil seal front, Acc. Drive Seal and rearsuitable side for following Capacity DG Sets make Kirlosker/ cummins/Greaves complete all as specified and directed by Engr-in-Charge.( Installation Part) |
| 254 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 255 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 256 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 257 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 258 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 259 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 260 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 261 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 262 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 263 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 264 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 265 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 266 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 267 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 268 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 269 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 270 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 271 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 272 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 273 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 274 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 275 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 276 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 277 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 278 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 279 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 280 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 281 | Supply of Battery 12 Volt 180 AH (Maint free heavy duty with initial charging.Make- Exide/Amron.all as specified and directed by Engr-in-Charge |
| 282 | Installation of Battery 12 Volt 180 AH (Maint free heavy duty with initial charging.Make- Exide/Amron.all as specified and directed by Engr-in-Charge |
| 283 | Supply of M &L for Removing the fuel injection pump (FIP) from following capacity of DG sets and carry out servicing and calibration including replacement and refitting the same for smooth and efficient functioning all as directed by Engr-in-Charge. Note :-Repairs will be carried out from authorised workshop of MICO or manufacturer of DG set. ( Supply Part) |
| 284 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 285 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 286 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 287 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 288 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 289 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 290 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 291 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 292 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 293 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 294 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 295 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 296 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 297 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 298 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 299 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 300 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 301 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 302 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 303 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 304 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 305 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 306 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 307 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 308 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 309 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 310 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 311 | Fixing of M &L for Removing the fuel injection pump (FIP) from following capacity of DG sets and carry out servicing and calibration including replacement and refitting the same for smooth and efficient functioning all as directed by Engr-in-Charge. Note :-Repairs will be carried out from authorised workshop of MICO or manufacturer of DG set. ( Installation Part) |
| 312 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 313 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 314 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 315 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 316 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 317 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 318 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 319 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 320 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 321 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 322 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 323 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 324 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 325 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 326 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 327 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 328 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 329 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 330 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 331 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 332 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 333 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 334 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 335 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 336 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 337 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 338 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 339 | Supply of M &L for Removing the injectors from following capacity of DG sets and carry out servicing and calibration including replacement of injectors nozzles, etc. and refitting the same for smooth and efficient functioning all as directed by Engr-in-Charge. Note :-Repairs will be carried out from authorised workshop of MICO or manufacturer of DG set. ( Supply Part) |
| 340 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 341 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 342 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 343 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 344 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 345 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 346 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 347 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 348 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 349 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 350 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 351 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 352 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 353 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 354 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 355 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 356 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 357 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 358 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 359 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 360 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 361 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 362 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 363 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 364 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 365 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 366 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 367 | Fixing of M &L for Removing the injectors from following capacity of DG sets and carry out servicing and calibration including replacement of injectors nozzles, etc. and refitting the same for smooth and efficient functioning all as directed by Engr-in-Charge. Note :-Repairs will be carried out from authorised workshop of MICO or manufacturer of DG set. ( Installation Part) |
| 368 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 369 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 370 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 371 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 372 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 373 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 374 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 375 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 376 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 377 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 378 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 379 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 380 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 381 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 382 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 383 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 384 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 385 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 386 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 387 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 388 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 389 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 390 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 391 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 392 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 393 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 394 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 395 | Supply of the radiator assembly of following capacity DG sets cleaning radiator by using K oil and radiator cleaning solution (Ready to Wash) by pressure of pump and brush and Re-assembling after painting of the same complete all as specified and directed by Engr-in-Charge.( Supply Part) |
| 396 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 397 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 398 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 399 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 400 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 401 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 402 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 403 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 404 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 405 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 406 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 407 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 408 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 409 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 410 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 411 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 412 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 413 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 414 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 415 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 416 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 417 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 418 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 419 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 420 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 421 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 422 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 423 | M & L for dismantling the defective radiator assembly and taking it to contractor workshop for cleaning of radiator , finding the leakages by pressure method and providing leak proof treatment to defective radiator assemble by welding/brazing/glazing suitable material for cohesiveness for following capacity DG sets cleaning radiator by using K oil and radiator cleaning solution (Ready to Wash) by pressure of pump and brush and Re-assembling after painting of the same complete all as specified and directed by Engr-in-Charge.Installation Part) |
| 424 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 425 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 426 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 427 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 428 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 429 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 430 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 431 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 432 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 433 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 434 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 435 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 436 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 437 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 438 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 439 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 440 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 441 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 442 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 443 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 444 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 445 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 446 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 447 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 448 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 449 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 450 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 451 | General/Major Overhauling |
| 452 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 453 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 454 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 455 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 456 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 457 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 458 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 459 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 460 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 461 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 462 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 463 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 464 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 465 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 466 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 467 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 468 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 469 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 470 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 471 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 472 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 473 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 474 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 475 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 476 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 477 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 478 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 479 | Top/Minor Overhauling |
| 480 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 481 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 482 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 483 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 484 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 485 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 486 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 487 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 488 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 489 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 490 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 491 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 492 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 493 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 494 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 495 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 496 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 497 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 498 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 499 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 500 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 501 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 502 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 503 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 504 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 505 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 506 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 507 | Replacement of water Separator assembly for following capacity DG sets make : Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 508 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 509 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 510 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 511 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 512 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 513 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 514 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 515 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 516 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 517 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 518 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 519 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 520 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 521 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 522 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 523 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 524 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 525 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 526 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 527 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 528 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 529 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 530 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 531 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 532 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 533 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 534 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 535 | Replacement of water Separator assembly for following capacity DG sets make : Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge. ( Installation Part) |
| 536 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 537 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 538 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 539 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 540 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 541 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 542 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 543 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 544 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 545 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 546 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 547 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 548 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 549 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 550 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 551 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 552 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 553 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 554 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 555 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 556 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 557 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 558 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 559 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 560 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 561 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 562 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 563 | Supply of bty charging alternator (12 volt) with 2 wire system for any capacity of DG Set |
| 564 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 565 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 566 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 567 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 568 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 569 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 570 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 571 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 572 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 573 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 574 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 575 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 576 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 577 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 578 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 579 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 580 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 581 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 582 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 583 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 584 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 585 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 586 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 587 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 588 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 589 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 590 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 591 | Installation of bty charging alternator (12 volt) with 2 wire system for any capacity of DG Set |
| 592 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 593 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 594 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 595 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 596 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 597 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 598 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 599 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 600 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 601 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 602 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 603 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 604 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 605 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 606 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 607 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 608 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 609 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 610 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 611 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 612 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 613 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 614 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 615 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 616 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 617 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 618 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 619 | Supply of Digital RPM meter with Hour meter for any capacity of DG Set |
| 620 | Fixing of Digital RPM meter with Hour meter for any capacity of DG Set |
| 621 | Supply Air cleaner for various capacity DG set (primary + secondary) |
| 622 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 623 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 624 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 625 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 626 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 627 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 628 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 629 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 630 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 631 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 632 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 633 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 634 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 635 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 636 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 637 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 638 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 639 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 640 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 641 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 642 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 643 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 644 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 645 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 646 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 647 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 648 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 649 | Fixing Air cleaner for various capacity DG set (primary + secondary) |
| 650 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 651 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 652 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 653 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 654 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 655 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 656 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 657 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 658 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 659 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 660 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 661 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 662 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 663 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 664 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 665 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 666 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 667 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 668 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 669 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 670 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 671 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 672 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 673 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 674 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 675 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 676 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 677 | Supply of Stainless steel, Grey colour anti-vibration support pads for isolating the DG Set engine and alternator from the mounting frame having weighing capacity upto 400 Kgs each for suitable capacity of DG set complete all as specified and directed by Engr-in-Charge. |
| 678 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 679 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 680 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 681 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 682 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 683 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 684 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 685 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 686 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 687 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 688 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 689 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 690 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 691 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 692 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 693 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 694 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 695 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 696 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 697 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 698 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 699 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 700 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 701 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 702 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 703 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 704 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 705 | Fixing Stainless steel, Grey colour anti-vibration support pads for isolating the DG Set engine and alternator from the mounting frame having weighing capacity upto 400 Kgs each for suitable capacity of DG set complete all as specified and directed by Engr-in-Charge. |
| 706 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 707 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 708 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 709 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 710 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 711 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 712 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 713 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 714 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 715 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 716 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 717 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 718 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 719 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 720 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 721 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 722 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 723 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 724 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 725 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 726 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 727 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 728 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 729 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 730 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 731 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 732 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 733 | Supply of battery terminal for DG Sets complete all as specified and directed by Engr-in-Charge. |
| 734 | Replacement of battery terminal for DG Sets complete all as specified and directed by Engr-in-Charge.( Installation Charges) |
| 735 | Supply of battery cable assy. with copper conductor multistranded RED and BLACK colour 2mtr long 21sqmm for connection to self starter unit to Battery unit complete. |
| 736 | Fixing battery cable assy. with copper conductor multistranded RED and BLACK colour 2mtr long 21sqmm for connection to self starter unit to Battery unit complete. |
| 737 | Supply of best quality anti freezing,Inhabitor Corrosion (Coolant ) liquid for DG set at varrious capacity and locations complete all as specified and directed. Make-castrol/veedol/valoline |
| 738 | toping up of best quality anti freezing,Inhabitor Corrosion (Coolant ) liquid for DG set at varrious capacity and locations complete all as specified and directed. Make-castrol/veedol/valoline( Labour Part) |
| 739 | Dismantling of panel control assembly PCC of DG set |
| 740 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 741 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 742 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 743 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 744 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 745 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 746 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 747 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 748 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 749 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 750 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 751 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 752 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 753 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 754 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 755 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 756 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 757 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 758 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 759 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 760 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 761 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 762 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 763 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 764 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 765 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 766 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 767 | Replacement of panel control assembly PCC of DG set |
| 768 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 769 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 770 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 771 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 772 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 773 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 774 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 775 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 776 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 777 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 778 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 779 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 780 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 781 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 782 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 783 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 784 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 785 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 786 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 787 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 788 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 789 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 790 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 791 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 792 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 793 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 794 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 795 | Replacement of oil filter element as per existing for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 796 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 797 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 798 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 799 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 800 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 801 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 802 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 803 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 804 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 805 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 806 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 807 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 808 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 809 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 810 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 811 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 812 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 813 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 814 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 815 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 816 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 817 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 818 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 819 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 820 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 821 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 822 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 823 | Replacement of Charging Alternator belt suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 824 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 825 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 826 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 827 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 828 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 829 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 830 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 831 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 832 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 833 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 834 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 835 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 836 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 837 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 838 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 839 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 840 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 841 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 842 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 843 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 844 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 845 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 846 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 847 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 848 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 849 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 850 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 851 | Replacement of Charging Alternator belt suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation Part) |
| 852 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 853 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 854 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 855 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 856 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 857 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 858 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 859 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 860 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 861 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 862 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 863 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 864 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 865 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 866 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 867 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 868 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 869 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 870 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 871 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 872 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 873 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 874 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 875 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 876 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 877 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 878 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 879 | Replacement of Fan belt suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 880 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 881 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 882 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 883 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 884 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 885 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 886 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 887 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 888 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 889 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 890 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 891 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 892 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 893 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 894 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 895 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 896 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 897 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 898 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 899 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 900 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 901 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 902 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 903 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 904 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 905 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 906 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 907 | Replacement of Fan belt suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation Part) |
| 908 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 909 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 910 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 911 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 912 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 913 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 914 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 915 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 916 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 917 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 918 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 919 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 920 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 921 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 922 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 923 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 924 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 925 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 926 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 927 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 928 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 929 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 930 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 931 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 932 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 933 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 934 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 935 | Replacement of air cleaner l filter element ( inner and outer ) suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 936 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 937 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 938 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 939 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 940 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 941 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 942 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 943 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 944 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 945 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 946 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 947 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 948 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 949 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 950 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 951 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 952 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 953 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 954 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 955 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 956 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 957 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 958 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 959 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 960 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 961 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 962 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 963 | Repair of air cleaner filter element ( inner and outer ) suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 964 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 965 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 966 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 967 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 968 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 969 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 970 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 971 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 972 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 973 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 974 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 975 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 976 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 977 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 978 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 979 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 980 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 981 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 982 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 983 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 984 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 985 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 986 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 987 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 988 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 989 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 990 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 991 | Replacement of fuel cleaner l filter element ( Primary and secondary ) and fuel water separator as per existing for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 992 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 993 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 994 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 995 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 996 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 997 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 998 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 999 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 1000 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 1001 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 1002 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 1003 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 1004 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 1005 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1006 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 1007 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 1008 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1009 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 1010 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 1011 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 1012 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 1013 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 1014 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 1015 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 1016 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 1017 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1018 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1019 | Repair of fuel cleaner filter element ( Primary and secondary ) and fuel water separator as per existing for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 1020 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 1021 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 1022 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 1023 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 1024 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 1025 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 1026 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 1027 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 1028 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 1029 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 1030 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 1031 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 1032 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 1033 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1034 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 1035 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 1036 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1037 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 1038 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 1039 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 1040 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 1041 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 1042 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 1043 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 1044 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 1045 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 1046 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 1047 | Replacement of V- belt water Pump suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 1048 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 1049 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 1050 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 1051 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 1052 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 1053 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 1054 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 1055 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 1056 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 1057 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 1058 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 1059 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 1060 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 1061 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1062 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 1063 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 1064 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1065 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 1066 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 1067 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 1068 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 1069 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 1070 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 1071 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 1072 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 1073 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1074 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1075 | Repair of V- belt water Pump suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 1076 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 1077 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 1078 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 1079 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 1080 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 1081 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 1082 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 1083 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 1084 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 1085 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 1086 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 1087 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 1088 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 1089 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1090 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 1091 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 1092 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1093 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 1094 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 1095 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 1096 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 1097 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 1098 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 1099 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 1100 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 1101 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 1102 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 1103 | S& F replacement of AVR 24 Volt suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 1104 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 1105 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 1106 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 1107 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 1108 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 1109 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 1110 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 1111 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 1112 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 1113 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 1114 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 1115 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 1116 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 1117 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1118 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 1119 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 1120 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1121 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 1122 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 1123 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 1124 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 1125 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 1126 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 1127 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 1128 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 1129 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1130 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1131 | S& F Installation of AVR 24 Volt suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 1132 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 1133 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 1134 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 1135 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 1136 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 1137 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 1138 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 1139 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 1140 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 1141 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 1142 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 1143 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 1144 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 1145 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1146 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 1147 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 1148 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1149 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 1150 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 1151 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 1152 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 1153 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 1154 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 1155 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 1156 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 1157 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 1158 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 1159 | supply of Self starter suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 1160 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 1161 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 1162 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 1163 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 1164 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 1165 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 1166 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 1167 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 1168 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 1169 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 1170 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 1171 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 1172 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 1173 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1174 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 1175 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 1176 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1177 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 1178 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 1179 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 1180 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 1181 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 1182 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 1183 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 1184 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 1185 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1186 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1187 | Installation of self starter suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. (installation part) |
| 1188 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 1189 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 1190 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 1191 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 1192 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 1193 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 1194 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 1195 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 1196 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 1197 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 1198 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 1199 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 1200 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 1201 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1202 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 1203 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 1204 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1205 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 1206 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 1207 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 1208 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 1209 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 1210 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 1211 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 1212 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 1213 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 1214 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 1215 | supply of Water Pump Assembley suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 1216 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 1217 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 1218 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 1219 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 1220 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 1221 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 1222 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 1223 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 1224 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 1225 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 1226 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 1227 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 1228 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 1229 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1230 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 1231 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 1232 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1233 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 1234 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 1235 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 1236 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 1237 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 1238 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 1239 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 1240 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 1241 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1242 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1243 | Installation of Water Pump Assembley for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge ( Installation part) |
| 1244 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 1245 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 1246 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 1247 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 1248 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 1249 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 1250 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 1251 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 1252 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 1253 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 1254 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 1255 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 1256 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 1257 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1258 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 1259 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 1260 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1261 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 1262 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 1263 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 1264 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 1265 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 1266 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 1267 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 1268 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 1269 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 1270 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 1271 | supply of Turbo Charger Assembley suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 1272 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 1273 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 1274 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 1275 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 1276 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 1277 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 1278 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 1279 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 1280 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 1281 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 1282 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 1283 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 1284 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 1285 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1286 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 1287 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 1288 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1289 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 1290 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 1291 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 1292 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 1293 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 1294 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 1295 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 1296 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 1297 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1298 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1299 | Installation of Turbo Charger Assembley for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 1300 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 1301 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 1302 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 1303 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 1304 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 1305 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 1306 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 1307 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 1308 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 1309 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 1310 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 1311 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 1312 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 1313 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1314 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 1315 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 1316 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1317 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 1318 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 1319 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 1320 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 1321 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 1322 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 1323 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 1324 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 1325 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 1326 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 1327 | supply of Fan Hub Assembley suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 1328 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 1329 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 1330 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 1331 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 1332 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 1333 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 1334 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 1335 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 1336 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 1337 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 1338 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 1339 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 1340 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 1341 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1342 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 1343 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 1344 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1345 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 1346 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 1347 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 1348 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 1349 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 1350 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 1351 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 1352 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 1353 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1354 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1355 | Installation of Fan Hub Assembley for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 1356 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 1357 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 1358 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 1359 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 1360 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 1361 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 1362 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 1363 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 1364 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 1365 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 1366 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 1367 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 1368 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 1369 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1370 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 1371 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 1372 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1373 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 1374 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 1375 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 1376 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 1377 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 1378 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 1379 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 1380 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 1381 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 1382 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 1383 | supply of Alternator Fan suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 1384 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 1385 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 1386 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 1387 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 1388 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 1389 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 1390 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 1391 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 1392 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 1393 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 1394 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 1395 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 1396 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 1397 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1398 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 1399 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 1400 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1401 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 1402 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 1403 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 1404 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 1405 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 1406 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 1407 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 1408 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 1409 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1410 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1411 | Installation of Alternator Fan for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 1412 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 1413 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 1414 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 1415 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 1416 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 1417 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 1418 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 1419 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 1420 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 1421 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 1422 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 1423 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 1424 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 1425 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1426 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 1427 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 1428 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1429 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 1430 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 1431 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 1432 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 1433 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 1434 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 1435 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 1436 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 1437 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 1438 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 1439 | supply of Engine Fan suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 1440 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 1441 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 1442 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 1443 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 1444 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 1445 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 1446 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 1447 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 1448 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 1449 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 1450 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 1451 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 1452 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 1453 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1454 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 1455 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 1456 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1457 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 1458 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 1459 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 1460 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 1461 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 1462 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 1463 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 1464 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 1465 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1466 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1467 | Installation of Engine Fan for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 1468 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 1469 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 1470 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 1471 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 1472 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 1473 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 1474 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 1475 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 1476 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 1477 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 1478 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 1479 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 1480 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 1481 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1482 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 1483 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 1484 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1485 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 1486 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 1487 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 1488 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 1489 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 1490 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 1491 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 1492 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 1493 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 1494 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 1495 | supply of Lub oil Pump suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 1496 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 1497 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 1498 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 1499 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 1500 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 1501 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 1502 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 1503 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 1504 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 1505 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 1506 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 1507 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 1508 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 1509 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1510 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 1511 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 1512 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1513 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 1514 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 1515 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 1516 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 1517 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 1518 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 1519 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 1520 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 1521 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1522 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1523 | Installation of Lub oil Pum for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 1524 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 1525 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 1526 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 1527 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 1528 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 1529 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 1530 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 1531 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 1532 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 1533 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 1534 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 1535 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 1536 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 1537 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1538 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 1539 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 1540 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1541 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 1542 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 1543 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 1544 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 1545 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 1546 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 1547 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 1548 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 1549 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 1550 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 1551 | supply of Thermo state suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 1552 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 1553 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 1554 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 1555 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 1556 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 1557 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 1558 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 1559 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 1560 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 1561 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 1562 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 1563 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 1564 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 1565 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1566 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 1567 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 1568 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1569 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 1570 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 1571 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 1572 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 1573 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 1574 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 1575 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 1576 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 1577 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1578 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1579 | Installation of Thermo state for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge.( Installation part) |
| 1580 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 1581 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 1582 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 1583 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 1584 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 1585 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 1586 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 1587 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 1588 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 1589 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 1590 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 1591 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 1592 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 1593 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1594 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 1595 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 1596 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1597 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 1598 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 1599 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 1600 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 1601 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 1602 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 1603 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 1604 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 1605 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 1606 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 1607 | supply of Battery charger 12 volt 10 AMps suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 1608 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 1609 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 1610 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 1611 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 1612 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 1613 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 1614 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 1615 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 1616 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 1617 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 1618 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 1619 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 1620 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 1621 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1622 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 1623 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 1624 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1625 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 1626 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 1627 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 1628 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 1629 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 1630 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 1631 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 1632 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 1633 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1634 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1635 | Installation of Battery charger 12 Volt 10 Amps for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 1636 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 1637 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 1638 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 1639 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 1640 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 1641 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 1642 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 1643 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 1644 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 1645 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 1646 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 1647 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 1648 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 1649 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1650 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 1651 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 1652 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1653 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 1654 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 1655 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 1656 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 1657 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 1658 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 1659 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 1660 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 1661 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 1662 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 1663 | supply of Battery charger 24 volt 10 AMps suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 1664 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 1665 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 1666 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 1667 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 1668 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 1669 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 1670 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 1671 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 1672 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 1673 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 1674 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 1675 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 1676 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 1677 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1678 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 1679 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 1680 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1681 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 1682 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 1683 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 1684 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 1685 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 1686 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 1687 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 1688 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 1689 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1690 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1691 | Installation of Battery charger 24 Volt 10 Amps for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. (Installation part) |
| 1692 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 1693 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 1694 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 1695 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 1696 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 1697 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 1698 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 1699 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 1700 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 1701 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 1702 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 1703 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 1704 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 1705 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1706 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 1707 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 1708 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1709 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 1710 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 1711 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 1712 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 1713 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 1714 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 1715 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 1716 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 1717 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 1718 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 1719 | supply of battery cable assembly with copper conductor multi stand Red and Black colour suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 1720 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 1721 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 1722 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 1723 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 1724 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 1725 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 1726 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 1727 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 1728 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 1729 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 1730 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 1731 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 1732 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 1733 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1734 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 1735 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 1736 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1737 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 1738 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 1739 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 1740 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 1741 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 1742 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 1743 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 1744 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 1745 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1746 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1747 | Installation of battery cable assembly with copper conductor multi stand Red and Black colour for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 1748 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 1749 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 1750 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 1751 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 1752 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 1753 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 1754 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 1755 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 1756 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 1757 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 1758 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 1759 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 1760 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 1761 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1762 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 1763 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 1764 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1765 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 1766 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 1767 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 1768 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 1769 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 1770 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 1771 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 1772 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 1773 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 1774 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 1775 | Taking down old rusted unservicible silencer single / double with exhaust pipe and M&L for new silencer with exhaust pipe complete bends,coupling etc suitable for following capacities of DG set ( Supply Part) |
| 1776 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 1777 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 1778 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 1779 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 1780 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 1781 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 1782 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 1783 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 1784 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 1785 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 1786 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 1787 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 1788 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 1789 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1790 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 1791 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 1792 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1793 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 1794 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 1795 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 1796 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 1797 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 1798 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 1799 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 1800 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 1801 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1802 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1803 | Taking down old rusted unservicible silencer single / double with exhaust pipe and M&L for new silencer with exhaust pipe complete bends,coupling etc suitable for following capacities of DG set ( Installation Part) |
| 1804 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 1805 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 1806 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 1807 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 1808 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 1809 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 1810 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 1811 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 1812 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 1813 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 1814 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 1815 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 1816 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 1817 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1818 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 1819 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 1820 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1821 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 1822 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 1823 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 1824 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 1825 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 1826 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 1827 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 1828 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 1829 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 1830 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 1831 | supply of Head Gasket suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 1832 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 1833 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 1834 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 1835 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 1836 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 1837 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 1838 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 1839 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 1840 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 1841 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 1842 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 1843 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 1844 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 1845 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1846 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 1847 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 1848 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1849 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 1850 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 1851 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 1852 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 1853 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 1854 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 1855 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 1856 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 1857 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1858 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1859 | Installation of Head Gasket suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 1860 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 1861 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 1862 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 1863 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 1864 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 1865 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 1866 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 1867 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 1868 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 1869 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 1870 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 1871 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 1872 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 1873 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1874 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 1875 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 1876 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1877 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 1878 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 1879 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 1880 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 1881 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 1882 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 1883 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 1884 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 1885 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 1886 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 1887 | supply of Lower Gasket set suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 1888 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 1889 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 1890 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 1891 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 1892 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 1893 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 1894 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 1895 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 1896 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 1897 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 1898 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 1899 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 1900 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 1901 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1902 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 1903 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 1904 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1905 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 1906 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 1907 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 1908 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 1909 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 1910 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 1911 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 1912 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 1913 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1914 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1915 | Installation of Lower Gasket set suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 1916 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 1917 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 1918 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 1919 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 1920 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 1921 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 1922 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 1923 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 1924 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 1925 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 1926 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 1927 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 1928 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 1929 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1930 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 1931 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 1932 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1933 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 1934 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 1935 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 1936 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 1937 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 1938 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 1939 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 1940 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 1941 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 1942 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 1943 | supply of Oil Pan Gasket suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 1944 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 1945 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 1946 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 1947 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 1948 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 1949 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 1950 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 1951 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 1952 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 1953 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 1954 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 1955 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 1956 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 1957 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1958 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 1959 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 1960 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 1961 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 1962 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 1963 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 1964 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 1965 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 1966 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 1967 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 1968 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 1969 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1970 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 1971 | Installation of Oil Pan Gasket suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 1972 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 1973 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 1974 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 1975 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 1976 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 1977 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 1978 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 1979 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 1980 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 1981 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 1982 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 1983 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 1984 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 1985 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1986 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 1987 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 1988 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 1989 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 1990 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 1991 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 1992 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 1993 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 1994 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 1995 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 1996 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 1997 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 1998 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 1999 | supply of Inspection Plate Gasket suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 2000 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 2001 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 2002 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 2003 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 2004 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 2005 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 2006 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 2007 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 2008 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 2009 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 2010 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 2011 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 2012 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 2013 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2014 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 2015 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 2016 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2017 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 2018 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 2019 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 2020 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 2021 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 2022 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 2023 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 2024 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 2025 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2026 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2027 | Installation of Inspection Plate Gasket suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 2028 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 2029 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 2030 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 2031 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 2032 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 2033 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 2034 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 2035 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 2036 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 2037 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 2038 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 2039 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 2040 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 2041 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2042 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 2043 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 2044 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2045 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 2046 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 2047 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 2048 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 2049 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 2050 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 2051 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 2052 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 2053 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 2054 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 2055 | supply of Turbo Charger Gasket suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 2056 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 2057 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 2058 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 2059 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 2060 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 2061 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 2062 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 2063 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 2064 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 2065 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 2066 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 2067 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 2068 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 2069 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2070 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 2071 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 2072 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2073 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 2074 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 2075 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 2076 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 2077 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 2078 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 2079 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 2080 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 2081 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2082 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2083 | Installation of Turbo Charger Gasket suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 2084 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 2085 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 2086 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 2087 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 2088 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 2089 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 2090 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 2091 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 2092 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 2093 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 2094 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 2095 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 2096 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 2097 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2098 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 2099 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 2100 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2101 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 2102 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 2103 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 2104 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 2105 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 2106 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 2107 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 2108 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 2109 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 2110 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 2111 | supply of After Cooler Gasket suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 2112 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 2113 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 2114 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 2115 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 2116 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 2117 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 2118 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 2119 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 2120 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 2121 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 2122 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 2123 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 2124 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 2125 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2126 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 2127 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 2128 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2129 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 2130 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 2131 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 2132 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 2133 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 2134 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 2135 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 2136 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 2137 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2138 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2139 | Installation of After Cooler Gasket suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 2140 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 2141 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 2142 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 2143 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 2144 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 2145 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 2146 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 2147 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 2148 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 2149 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 2150 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 2151 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 2152 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 2153 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2154 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 2155 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 2156 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2157 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 2158 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 2159 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 2160 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 2161 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 2162 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 2163 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 2164 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 2165 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 2166 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 2167 | supply of Cross over Gasket suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 2168 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 2169 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 2170 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 2171 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 2172 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 2173 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 2174 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 2175 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 2176 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 2177 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 2178 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 2179 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 2180 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 2181 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2182 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 2183 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 2184 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2185 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 2186 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 2187 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 2188 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 2189 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 2190 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 2191 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 2192 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 2193 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2194 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2195 | Installation of Cross over Gasket suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 2196 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 2197 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 2198 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 2199 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 2200 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 2201 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 2202 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 2203 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 2204 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 2205 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 2206 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 2207 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 2208 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 2209 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2210 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 2211 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 2212 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2213 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 2214 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 2215 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 2216 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 2217 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 2218 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 2219 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 2220 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 2221 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 2222 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 2223 | supply of Tappet Gasket suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 2224 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 2225 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 2226 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 2227 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 2228 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 2229 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 2230 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 2231 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 2232 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 2233 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 2234 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 2235 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 2236 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 2237 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2238 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 2239 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 2240 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2241 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 2242 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 2243 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 2244 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 2245 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 2246 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 2247 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 2248 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 2249 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2250 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2251 | Installation of Tappet Gasket suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 2252 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 2253 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 2254 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 2255 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 2256 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 2257 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 2258 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 2259 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 2260 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 2261 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 2262 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 2263 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 2264 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 2265 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2266 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 2267 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 2268 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2269 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 2270 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 2271 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 2272 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 2273 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 2274 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 2275 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 2276 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 2277 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 2278 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 2279 | supply of Oil Cooler suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 2280 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 2281 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 2282 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 2283 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 2284 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 2285 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 2286 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 2287 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 2288 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 2289 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 2290 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 2291 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 2292 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 2293 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2294 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 2295 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 2296 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2297 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 2298 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 2299 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 2300 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 2301 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 2302 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 2303 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 2304 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 2305 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2306 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2307 | Installation of Oil Cooler suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 2308 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 2309 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 2310 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 2311 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 2312 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 2313 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 2314 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 2315 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 2316 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 2317 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 2318 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 2319 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 2320 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 2321 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2322 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 2323 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 2324 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2325 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 2326 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 2327 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 2328 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 2329 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 2330 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 2331 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 2332 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 2333 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 2334 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 2335 | supply of Liner suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 2336 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 2337 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 2338 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 2339 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 2340 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 2341 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 2342 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 2343 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 2344 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 2345 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 2346 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 2347 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 2348 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 2349 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2350 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 2351 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 2352 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2353 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 2354 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 2355 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 2356 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 2357 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 2358 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 2359 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 2360 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 2361 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2362 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2363 | Installation of Liner suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 2364 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 2365 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 2366 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 2367 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 2368 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 2369 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 2370 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 2371 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 2372 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 2373 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 2374 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 2375 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 2376 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 2377 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2378 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 2379 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 2380 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2381 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 2382 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 2383 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 2384 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 2385 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 2386 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 2387 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 2388 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 2389 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 2390 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 2391 | supply of Piston and Ring Set suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 2392 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 2393 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 2394 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 2395 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 2396 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 2397 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 2398 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 2399 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 2400 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 2401 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 2402 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 2403 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 2404 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 2405 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2406 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 2407 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 2408 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2409 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 2410 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 2411 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 2412 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 2413 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 2414 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 2415 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 2416 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 2417 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2418 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2419 | Installation of Piston and Ring Set suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 2420 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 2421 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 2422 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 2423 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 2424 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 2425 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 2426 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 2427 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 2428 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 2429 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 2430 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 2431 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 2432 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 2433 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2434 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 2435 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 2436 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2437 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 2438 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 2439 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 2440 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 2441 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 2442 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 2443 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 2444 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 2445 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 2446 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 2447 | supply of CR Bearing suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 2448 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 2449 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 2450 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 2451 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 2452 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 2453 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 2454 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 2455 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 2456 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 2457 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 2458 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 2459 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 2460 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 2461 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2462 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 2463 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 2464 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2465 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 2466 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 2467 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 2468 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 2469 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 2470 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 2471 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 2472 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 2473 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2474 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2475 | Installation of CR Bearing suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 2476 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 2477 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 2478 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 2479 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 2480 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 2481 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 2482 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 2483 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 2484 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 2485 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 2486 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 2487 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 2488 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 2489 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2490 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 2491 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 2492 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2493 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 2494 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 2495 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 2496 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 2497 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 2498 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 2499 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 2500 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 2501 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 2502 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 2503 | supply of Push Rod Valve suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 2504 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 2505 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 2506 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 2507 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 2508 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 2509 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 2510 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 2511 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 2512 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 2513 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 2514 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 2515 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 2516 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 2517 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2518 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 2519 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 2520 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2521 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 2522 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 2523 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 2524 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 2525 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 2526 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 2527 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 2528 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 2529 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2530 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2531 | Installation of Push Rod Valve suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 2532 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 2533 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 2534 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 2535 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 2536 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 2537 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 2538 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 2539 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 2540 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 2541 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 2542 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 2543 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 2544 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 2545 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2546 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 2547 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 2548 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2549 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 2550 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 2551 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 2552 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 2553 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 2554 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 2555 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 2556 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 2557 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 2558 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 2559 | supply of Push Rod Injectors suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 2560 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 2561 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 2562 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 2563 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 2564 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 2565 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 2566 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 2567 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 2568 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 2569 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 2570 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 2571 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 2572 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 2573 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2574 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 2575 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 2576 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2577 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 2578 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 2579 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 2580 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 2581 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 2582 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 2583 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 2584 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 2585 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2586 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2587 | Installation of Push Rod Injectors suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 2588 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 2589 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 2590 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 2591 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 2592 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 2593 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 2594 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 2595 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 2596 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 2597 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 2598 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 2599 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 2600 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 2601 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2602 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 2603 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 2604 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2605 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 2606 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 2607 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 2608 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 2609 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 2610 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 2611 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 2612 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 2613 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 2614 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 2615 | supply of Controller suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 2616 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 2617 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 2618 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 2619 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 2620 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 2621 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 2622 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 2623 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 2624 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 2625 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 2626 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 2627 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 2628 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 2629 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2630 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 2631 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 2632 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2633 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 2634 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 2635 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 2636 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 2637 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 2638 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 2639 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 2640 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 2641 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2642 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2643 | Installation of Controller suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 2644 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 2645 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 2646 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 2647 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 2648 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 2649 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 2650 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 2651 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 2652 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 2653 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 2654 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 2655 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 2656 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 2657 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2658 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 2659 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 2660 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2661 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 2662 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 2663 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 2664 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 2665 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 2666 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 2667 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 2668 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 2669 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 2670 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 2671 | supply of Water Hoses Set suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 2672 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 2673 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 2674 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 2675 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 2676 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 2677 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 2678 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 2679 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 2680 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 2681 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 2682 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 2683 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 2684 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 2685 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2686 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 2687 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 2688 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2689 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 2690 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 2691 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 2692 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 2693 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 2694 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 2695 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 2696 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 2697 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2698 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2699 | Installation of Water Hoses Set suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 2700 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 2701 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 2702 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 2703 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 2704 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 2705 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 2706 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 2707 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 2708 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 2709 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 2710 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 2711 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 2712 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 2713 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2714 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 2715 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 2716 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2717 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 2718 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 2719 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 2720 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 2721 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 2722 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 2723 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 2724 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 2725 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 2726 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 2727 | supply of Rubber Insert suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 2728 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 2729 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 2730 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 2731 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 2732 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 2733 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 2734 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 2735 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 2736 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 2737 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 2738 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 2739 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 2740 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 2741 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2742 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 2743 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 2744 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2745 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 2746 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 2747 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 2748 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 2749 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 2750 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 2751 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 2752 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 2753 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2754 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2755 | Installation of Rubber Insert suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 2756 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 2757 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 2758 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 2759 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 2760 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 2761 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 2762 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 2763 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 2764 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 2765 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 2766 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 2767 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 2768 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 2769 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2770 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 2771 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 2772 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2773 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 2774 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 2775 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 2776 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 2777 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 2778 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 2779 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 2780 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 2781 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 2782 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 2783 | supply of Aluminium Coupling suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Supply Part) |
| 2784 | 1500KVA DG Set (Cummins Make)( Supply Part) |
| 2785 | 750KVA DG Set (Cummins Make)( Supply Part) |
| 2786 | 320KVA DG Set (Cummins Make)( Supply Part) |
| 2787 | 320KVA DG Set (Mahindra Make)( Supply Part) |
| 2788 | 250KVA DG Set (Ashok Layland Make)( Supply Part) |
| 2789 | 250KVA DG Set (Cummins Make)( Supply Part) |
| 2790 | 250KVA DG Set (Kirloskar Make)( Supply Part) |
| 2791 | 200KVA DG Set (Cummins Make)( Supply Part) |
| 2792 | 200KVA DG Set (Mahindra Make)( Supply Part) |
| 2793 | 160KVA DG Set (Cummins Make)( Supply Part) |
| 2794 | 160 KVA DG set (Mahindra Make)( Supply Part) |
| 2795 | 160 KVA DG set (KIrloskar Make)( Supply Part) |
| 2796 | 125 KVA DG Set (Cummins Make)( Supply Part) |
| 2797 | 82.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2798 | 75 KVA DG Set (Cummins Make)( Supply Part) |
| 2799 | 62.5 KVA DG Set (Mahindra Make)( Supply Part) |
| 2800 | 62.5 KVA DG Set (Cummins Make)( Supply Part) |
| 2801 | 50 KVA DG Set (Cummins Make)( Supply Part) |
| 2802 | 40 KVA DG Set (Cummins Make)( Supply Part) |
| 2803 | 40 KVA DG Set (Mahindra Make)( Supply Part) |
| 2804 | 30KVA DG Set (Mahindra Make)( Supply Part) |
| 2805 | 30KVA DG Set (Cummins Make)( Supply Part) |
| 2806 | 25KVA DGSet (Mahindra Make)( Supply Part) |
| 2807 | 15KVA DGSet (Mahindra Make)( Supply Part) |
| 2808 | 15KVA DGSet (Kirloskar Make)( Supply Part) |
| 2809 | 10.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2810 | 7.5 KVA DGSet (Kirloskar Make)( Supply Part) |
| 2811 | Installation of Aluminium Coupling suitable for following capacity DG Set Make Kirlosker/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge. ( Installation part) |
| 2812 | 1500KVA DG Set (Cummins Make)( Installation Part) |
| 2813 | 750KVA DG Set (Cummins Make)(Installation Part) |
| 2814 | 320KVA DG Set (Cummins Make)( Installation Part) |
| 2815 | 320KVA DG Set (Mahindra Make)( Installation Part) |
| 2816 | 250KVA DG Set (Ashok Layland Make)( INstallation Part) |
| 2817 | 250KVA DG Set (Cummins Make)( Installation Part) |
| 2818 | 250KVA DG Set (Kirloskar Make)( Installation Part) |
| 2819 | 200KVA DG Set (Cummins Make)( Installation Part) |
| 2820 | 200KVA DG Set (Mahindra Make)(Installation Part) |
| 2821 | 160KVA DG Set (Cummins Make)( Installation Part) |
| 2822 | 160 KVA DG set (Mahindra Make)(Installation Part) |
| 2823 | 160 KVA DG set (KIrloskar Make)( Installation Part) |
| 2824 | 125 KVA DG Set (Cummins Make)( Installation Part) |
| 2825 | 82.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2826 | 75 KVA DG Set (Cummins Make)( Imstallation Part) |
| 2827 | 62.5 KVA DG Set (Mahindra Make)( Installation Part) |
| 2828 | 62.5 KVA DG Set (Cummins Make)( Installation Part) |
| 2829 | 50 KVA DG Set (Cummins Make)( Installation Part) |
| 2830 | 40 KVA DG Set (Cummins Make)( Installation Part) |
| 2831 | 40 KVA DG Set (Mahindra Make)( Installation Part) |
| 2832 | 30KVA DG Set (Mahindra Make)( Installation Part) |
| 2833 | 30KVA DG Set (Cummins Make)( Installation Part) |
| 2834 | 25KVA DGSet (Mahindra Make)( Installation Part) |
| 2835 | 15KVA DGSet (Mahindra Make)( Installation Part) |
| 2836 | 15KVA DGSet (Kirloskar Make)( Installation Part) |
| 2837 | 10.5 KVA DGSet (Kirloskar Make)(Installation Part) |
| 2838 | 7.5 KVA DGSet (Kirloskar Make)Installation Part) |
| 2839 | Per day rate for Technician/Engine Mechanic for any job not specified above |
| 2840 | Per day rate for Assistant Technician/Assistant Engine Mechanic for any job not specified above Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail