| 1 | Disconnection of LT APFC panel from main distribution panel. Segregation of all serviceable and unserviceable components like capacitors, contactors, auxilary block, CT coil, multifunction meters, relays, indicators, push button etc, carrying out servicing of complete APFC panel, by removing dust and cleaning by CRC solution. carrying out serviceability check of all components and refixing of all servicable components complete including connection with internal wiring. Replacement of all unserviceable components as per existing type/make and rating of equivalent type assembling the APFC panel, including connecting with LT distribution panel board and testing complete to the entire satisfaction of EIC. Note:- (i) All components/spares required to be replaced shall be measured and paid seperately under 'Supply & fixing' of item as detailed hereafter. (ii) The internal wiring of suitable size shall be of copper including terminal, lugs and screw to be replaced as per requirement and cost there of is deemed to be included in item rate. (iii) Inspection note indicating involvement of repair work and replacement of components is to be prepared and submitted by Contractor for each APFC panel complete all as specified and directed. |
| 2 | Supply and fixing including connection of capacitor duty contactor, 3 phase, 415V, 50Hz, built in de-latching auxilary contacts 1NO/1NC and damping resistors complete of following type and rated operational current (AC-1) :- Type MO C3, 10A complete all as specified and directed. |
| 3 | Supply and fixing including connection of capacitor duty contactor, 3 phase, 415V, 50Hz, built in de-latching auxilary contacts 1NO/1NC and damping resistors complete of following type and rated operational current (AC-1) :- Type MO C5, 10A complete all as specified and directed. |
| 4 | Supply and fixing including connection of capacitor duty contactor, 3 phase, 415V, 50Hz, built in de-latching auxilary contacts 1NO/1NC and damping resistors complete of following type and rated operational current (AC-1) :-Type MO C10, 25A complete all as specified and directed. |
| 5 | Supply and fixing including connection of capacitor duty contactor, 3 phase, 415V, 50Hz, built in de-latching auxilary contacts 1NO/1NC and damping resistors complete of following type and rated operational current (AC-1) :- Type MO C12.5, 40A complete all as specified and directed. |
| 6 | Supply and fixing including connection of capacitor duty contactor, 3 phase, 415V, 50Hz, built in de-latching auxilary contacts 1NO/1NC and damping resistors complete of following type and rated operational current (AC-1) :- Type MO C15, 40A complete all as specified and directed. |
| 7 | Supply and fixing including connection of capacitor duty contactor, 3 phase, 415V, 50Hz, built in de-latching auxilary contacts 1NO/1NC and damping resistors complete of following type and rated operational current (AC-1) :- Type MO C20, 50A complete all as specified and directed. |
| 8 | Supply and fixing including connection of capacitor duty contactor, 3 phase, 415V, 50Hz, built in de-latching auxilary contacts 1NO/1NC and damping resistors complete of following type and rated operational current (AC-1) :- Type MO C25, 50A complete all as specified and directed. |
| 9 | Supply and fixing APFC Controller for contactor switching with CT input, step 5 step having the feature of capacitor failure indication, suitable for HT & LT side sensing, measurement of individual current and voltage harmonic selectable CT secondary current 1A/5A, modular and expandable steps complete all as specified and directed. |
| 10 | All as per item No.9 here-in-before but 8 step (7+1) with the combination of 5 step APFC controller + 3 step plug in module. |
| 11 | All as per item No. 9 here-in-before but 10 step (9+1) with the combination of 8 step APFC controller + 2 step plug in module. |
| 12 | All as per item No. 9 here-in-before but 12 step (11+1) with the combination of 8 step APFC controller + 2 step plug in module + 2 step plug in module. |
| 13 | Supply and fixing single phase, current transformer, indoor, tape insulated, round type for measuring instrument having CT ratio as required at site according to the load complete all as specified and directed. |
| 14 | Supply and fixing Power Factor Correction capacitor heavy duty cylindrical series LTCCH type, gas filled, and rating 1 to 4 KVAR including internal connection complete all as specified and directed. |
| 15 | All as per above item No. 14 here-in-before but 5 KVAR to 15 KVAR. |
| 16 | All as per above item No. 14 here-in-before but 20 KVAR to 25 KVAR. |
| 17 | Supply and fixing dual source multifunction meter having Accuracy Class 1.0, 0.5, input voltage measurement range 50-520 VAC (P-P), Aux supply 80-300 VAC/DC, CT secondary site selectable 1A/5A, DG sensing input 230 VAC, Flush mounting 96 x 96 mm, CT/PT site programmable, parameters: V, A, F, PF, kW, kVA, Run hours, kWh (EB and DG), old energy, Site selectable kWh/kVAh complete all as specified and directed. |
| 18 | Supply and fixing Bolted fuse link , type HG, HRC fuse of rating 2A including fuse base bolted type 20A complete all as specified and as directed |
| 19 | All as per item No. 18 here-in-before but fuse link and fuse base of rating 32A. |
| 20 | Supply and fixing indicator lamp LED type (RYBG) complete all as specified and directed. |
| 21 | Supply and fixing Push button (Red & Blue) complete all as specified and directed. |
| 22 | Supply and fixing MCB SP (C) Curve Rating 6 to 32 Amps complete all as specified and as directed. |
| 23 | All as above item No. 22 here-in-before but TP 32 Amps. |
| 24 | All as above item No. 22 here-in-before but TP 40 to 63 Amps. |
| 25 | Supply and fixing Fan and thermostat assembly having range of temperature 30-110°C complete all as specified and directed. |
| 26 | M&L for repainting of APFC panel of different size using two coat of synthetic enamel spray painting after preparation of surface and carrying out minor repair to APFC panel enclosure by welding of hinges and replacement of locking arrangement and complete all as specified and directed. |
| 27 | M&L for repair to battery by replacement of lead acid batteries each of 12 Volts, 150 AH complete connected in series suitable for invetors / UPS with battery complete all as specified and directed. |
| 28 | M&L for Repair, maintenance, cleaning, servicing, and calabration of battery charger at main receiving station including replacement of faulty spares such as 220/110V AC transformer having current rating 5 Amps, PCB for main supply, PCB for float and boosting charging, variac variable transformer of suitable size, HRC fuses with fuse base, MCBs, indicator, voltmeter, ammeter etc. or any other spare required to made serviceable the battery charger complete all as specified and as directed.Note: Contractor may be visit the site before quoting the rate and work has to be completed upto entire satishfaction of Engr-in-Charge. |
| 29 | M&L for repair/ Servicing to Online UPS of rating 30 KVA Capacity suitable for 415 Volts, AC, 50 Hz, three phase complete of any make/type all as specified and directed including cleaning and segregation of serviceable and unserviceable components complete all as specified and directed.. |
| 30 | M&L for in replacement of Electronic sencing card (PCB) for Online UPS 30 KVA, 415 Volts, ac, 50 Hz, three phase complete as specified and directed |
| 31 | M&L for repair/ Servicing to Online UPS 12/15 KVA Capacity suitable for 415 Volts, ac, 50 Hz,Single phase complete as specified and directed |
| 32 | M&L for in replacement of Electronic sencing card (PCB) for Online UPS 12/15 KVA, 415 Volts, ac, 50 Hz, Single phase complete as specified and directed |
| 33 | Disconnecting and taking out the defective / non-functional desert cooler of any description and in any position and any floor installed at direct approach, strip opening of desert cooler, cleaning, servicing, oiling & greasing etc of desert cooler, taking out and removing unserviceable / defective parts and internal wiring, replacement of unserviceable & damaged parts and internal wiring, re-assembling & testing of the desert cooler all as specified and directed by Engineer-in-Charge. Note: - (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item .and replacement of unserviceable / damaged body portions i.e. panels / switch board / bottom / top / grills / frame etc. of the desert cooler shall also be measured and paid for separately under appropriate item of Schedule `A'. (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) The rates for above items are deemed to include for transportation to & fro of vertical pumps/fan motors to workshop as approved by Engineer-in-charge for necessary repairs, alignment and testing of pump and motors at workshop & replacement of necessary unserviceable screws/nuts/bolts/washers/ packing etc with new one. |
| 34 | Supply only PVC flexible water Pipe 15 mm dia complete all as specified and directed. |
| 35 | Supply only PVC distributor 3 way, suitable for 15mm dia water distribution all as specified and directed. |
| 36 | Supply only new 3 core PVC insulated copper cable size 1.5 Sq mm round 1100 volt grade as in connection to desert coolers all as specified and directed. |
| 37 | Supply only shaft for fan motor of desert cooler all as specified and directed. |
| 38 | Supply only gun metal bushes for fan motor of desert cooler all as specified and directed. |
| 39 | Taking out & removing old burnt out windings of fan motor and rewinding the fan motor of any description and in any capacity with using existing size copper super enameled wire as approved by the engineer-in-charge including insulating material such as luminous paper, Letherized paper, cotton tape, glass sleeving insulating varnish etc complete all as specified and directed by Engineer-in-Charge. NOTE : (i) Fixing, connecting and testing charges of the repaired motor are deemed to be included under respective item above) (ii) Replacement of unserviceable shaft / GM bushes, fan blades etc shall be measured and paid for separately under appropriate item of Schedule `A' as supply only |
| 40 | Supply only Air curtain panels (side and back removable panels) of any description and size for different size of desert coolers, made to shape and size with using 20 SWG gauge PGI sheets as per requirement including necessary mouldings etc to suit the existing cooler openings all as specified and directed. |
| 41 | Supply only submersible pump for desert cooler 1.5 mtr head complete all as specified and directed. |
| 42 | Supply only blower fan motor Copper winding for desert cooler single phase 230V, 150w to 180w. |
| 43 | Supply only aluminium fan blade ( set of three blades) for cooler motor of any description to suit existing motor all as specified and directed. |
| 44 | Replacement of damaged / unserviceable chicken wire mesh with using new hexagonal wire mesh having 15mm size mesh and 0.5mm dia of wire for supporting to the wood wool pads all as specified and directed. |
| 45 | Providing new wood wool pads of required size as approved (three in each on desert cooler) complete material and labour all as specified and directed. |
| 46 | Replacement of existing unserviceable front grills of any description and in any position with supplying and fixing new grills of existing shape and size and made out of 20 SWG, PGI sheet complete all as specified and directed. |
| 47 | M&L for Preparation of the steel surfaces of desert cooler and applying one coat of synthetic enameled paint (Blue) on all exterior surfaces and applying one coat of black bituminous paint on all interior surfaces including bottom surfaces as approved by the Engineer-in-Charge with different tint / colour complete all as specified and directed. |
| 48 | Supply and fixing 15mm dia Ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule all as specified and directed. |
| 49 | Supply and fixing 15mm dia Gun metal or gate valves, with iron wheel head, screwed, both end for iron pipe all as specified and directed. |
| 50 | Supply and fixing PVC connection 15mm size 450mm length complete with PTMT nuts on both ends all as specified and directed. |
| 51 | M&L for repair/ replacement of old/defective control wiring of Auxiliary control & relay panel control wiring work with marshalling box of 33 kv power Transformer and transformer to 33 kv VCB panel with total 12 core 2.5 Sqmm copper cable complete all as specified and directed. |
| 52 | Under ground Cable Testing / fault detection by authorised agency with Computerised Fault Detection Van complete to find the fault location for 33/11/0.440 KV rated UG cables as directed by Engineer in Charge at site. Note :- Any excavation and earth work and cable joint work involved shall be measured and paid separately against respective item. |
| 53 | Material & labour for replacement of laminated sheet board of installations, made out of sheet steel box, PVC acrylic glow sign board with reflector night vision of size 3.0 m x1.0 m x.0.60 m, complete with fixing material i.e. hole fastner, long screw, nut, bolts, washer, MS chain, clamps etc, including necessary PCC work (1:2:4), written with name of installation in proper size of letter, testing complete all as specified and as directed.Note :- Colour of board and size of letter is to be approved by GE before making order by Contractor. |
| 54 | Supply and Fix in replacement of XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional 16 sq mm 2 core, laid in trenches/ducts /encased in GI pipe /fixed to pole complete all as specified and directed. |
| 55 | Supply and Fix in replacement of XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional 16 sq mm 4 core, laid in trenches/ducts /encased in GI pipe /fixed to pole complete all as specified and directed. |
| 56 | Supply and Fix in replacement of XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional 35 sq mm 3.5 core, laid in trenches/ducts /encased in GI pipe /fixed to pole complete all as specified and directed. |
| 57 | Supply and Fix in replacement of XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional 50 sq mm 3.5 core, laid in trenches/ducts /encased in GI pipe /fixed to pole complete all as specified and directed. |
| 58 | Supply and Fix in replacement of XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional 95 sq mm 3.5 core, laid in trenches/ducts /encased in GI pipe /fixed to pole complete all as specified and directed. |
| 59 | Supply and Fix in replacement of XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional 150 sq mm 3.5 core, laid in trenches/ducts /encased in GI pipe /fixed to pole complete all as specified and directed. |
| 60 | Supply and Fix in replacement of XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional 185 sq mm 3.5 core, laid in trenches/ducts /encased in GI pipe /fixed to pole complete all as specified and directed. |
| 61 | Supplying and laying in Material and Labour for GI tubing medium grade in repairs incl. accessories for protection of cables on poles / under road crossing of sizes 80 mm dia complete all as specified and directed. |
| 62 | Supplying and laying in Material and Labour for GI tubing medium grade in repairs incl. accessories for protection of cables on poles / under road crossing of sizes 50 mm dia complete all as specified and directed. |
| 63 | Supplying and laying in Material and Labour for GI tubing medium grade in repairs incl. accessories for protection of cables on poles / under road crossing of sizes 40 mm dia . |
| 64 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, erection of poles, struts/stays, leveling of yard etc not exceeding 10 M² on plan and not exceeding 1.5 m in depth and getting out in all of kind of soil complete all as specified and directed. |
| 65 | Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m in depth upto 3.0 m for erection of poles, struts/stays, leveling of yard etc not exceeding 10 M² on plan and getting out in all of kind of soil complete all as specified and directed. |
| 66 | M&L for sand cushioning to U/G cable and punning for cushioning of cable 8 cm below the cable and 15cm above cable complete all as specified and directed. |
| 67 | Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size 250 mm x 150 mm x 40 mm and abutting each other with gap between adjacent precast concrete cable cover not exceeding 10 mm over underground cables for protection complete all as specified and directed. |
| 68 | Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soil. |
| 69 | Removing of excavated soil not exc. 50 M from starting points all as directed by EIC. |
| 70 | M&L for Auguring/ Driling /Boring of holes under road, pavement, hard standing by trenchless technology by mannual /machine, including fixing of HDPE pipe of 100 mm bore dia complete all as specified and directed. |
| 71 | Re-routing/relaying of existing LT cable PVC/XLPE insulated aluminium conductor armoured with glavanised steel wire complete of any size and core from any position i.e ground /wall/poles/ culverts etc complete with protection cover, sand, pipe complete all as specified and directed. Note:- (i) Old cable as obtained shall be re-used. (ii) Old serviceable protection cover, protection pipe and sand obtained under this item shall be reused if found serviceable.(iii) Earth work and any other new items shall be measured and paid separately under relavent items. |
| 72 | Material and labour for replacement of old unserviceable CT of LT Panel /Feeder pillar box with CT of ratio upto 200/5 Amps or as required at site according the load incl connecting, disconnecting and testing complete all as directed at site. |
| 73 | Material and labour for replacement of old unserviceable indicators any type with LED based indicating lamps of RYB colour incl disconnecting and connecting of the same all as directed at site. Make : Legrand/ABB/Siemens/L&T |
| 74 | Material and labour for fabrication of copper busbar iE26:E29 hot in any size and shape all as directed and including RYB insulation mounted on epoxy cast/polymer glass insulators all as directed by Engr-in-charge. |
| 75 | Supply, fixing and replacement of MCCB 250 Amps 4 pole 36 KA microprocessor adjustable release type (Icu=Ics=100%) including accessories like spreaders, nut bolt etc suitable setting complete all as directed. |
| 76 | Supply, fixing and replacement of MCCB 160 Amps 4 pole 36 KA microprocessor adjustable release type (Icu=Ics=100%) including accessories like spreaders, nut bolt etc suitable setting complete all as directed. |
| 77 | M&L for end outdoor/indoor jointing kit suitable for 4 to 16 sqmm 3.5 /4 core XLPE/ PVC Cable 1100 volts grade, heat shrinkable type for indoor/ outdoor applications complete including preparing ends of cable all as directed and specified |
| 78 | M&L for end outdoor/indoor jointing kit suitable for 25 to 50 sqmm 3.5 core XLPE/ PVC Cable 1100 volts grade, heat shrinkable type for indoor/ outdoor applications complete including preparing ends of cable all as directed and specified |
| 79 | M&L for end outdoor/indoor jointing kit suitable for 70 to 150 sqmm 3.5 core XLPE/ PVC Cable 1100 volts grade, heat shrinkable type for indoor/ outdoor applications complete including preparing ends of cable all as directed and specified |
| 80 | M&L for end outdoor/indoor jointing kit suitable for 185 to 300 sqmm 3.5 core XLPE/ PVC Cable 1100 volts grade, heat shrinkable type for indoor/ outdoor applications complete including preparing ends of cable all as directed and specified |
| 81 | Earthing complete with galvanized steel earth plate electrodes 600mm x 600mm x 6 mm thick buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanised iron earthing strip 32mm x 6mm thick by means of bolt nuts check nuts and washers of galvanized iron or steel all as specified & shown in electrical plate No.3 of MES SSR part-I 2010 connected to earth test point as specified and testing on completion including provision of 40 mm dia light grade pipe up to 7.5 mtr length as protection & watering pipe shall be 20 mm bore medium grade including all excavation & earth work in any type of strata incl PCC pit (1:3:6) type C-1 with RCC cover including charcoal , salt, funnel, all as directed at site. Note : 1) Rate included for excavation & earth work in any type of strata as shown in electric plate no-3 in SSR Part-I. 2) Rate included for dismantling of old earth pit and removal from site. |
| 82 | Supply, install, testing and commissioning of LT Panel board, outdoor type, gable roof, floor mounted, factory made (CPRI approved) suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with Aluminium bus bars of rating 800 amps duly insulated by insulation of RYB colour 400 Amps rating mounted on porcelain insulators. The panels shall be factory made of minimum sizes 1.3 0 m x1.20 m x 0.50 m,, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 40X40X5 mm and including of lowers on both sides including embedding the panel in PCC platform and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed and including danger board and including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement as desired complete all as directed by Engr-in-charge and comprising of the following:-(A) IN COMING(a) MCCB 4 Pole 415 Volts 36 KA 400 Amp rating microprocessor adjustable release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -01 No(b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No.(c) Panel mounted multi function energy (voltmeter & ammeter) meter of accuracy CL-1.0 rating including CT of ratio 200/5 - 01 No(B) OUT GOING(a) MCCB 4 Pole 415 Volts 36 KA 250 Amp rating microprocessor adjustable release release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -01 Nos(b) MCCB 4 Pole 415 Volts 36 KA 200 Amp rating microprocessor adjustable release release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -01 Nos(c) MCCB 4 Pole 415 Volts 36 KA 160 Amp rating microprocessor adjustable release type including spreaders , nut, bolts, lugs etc (Icu=Ics=100%) -01 No(d) MCCB 4 Pole 415 Volts 36 KA 100 Amp rating microprocessor adjustable release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -01 No(e) MCB 32 Amp TPN including , nut, bolts, lugs etc -02 Nos |
| 83 | Supply, install, testing and commissioning of LT Panel board, outdoor type, gable roof, floor mounted, factory made (CPRI approved) suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with Aluminium bus bars of rating 400 amps duly insulated by insulation of RYB colour 200 Amps rating mounted on porcelain insulators. The panels shall be factory made of minimum sizes 1.20 m x1.10 m x 0.40 m, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 40X40X5 mm and including of lowers on both sides including embedding the panel in PCC platform and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed and including danger board and including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement as desired complete all as directed by Engr-in-charge and comprising of the following:-(A) IN COMING(a) MCCB 4 Pole 415 Volts 36 KA 250 Amp rating microprocessor adjustable release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -01 No(b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No.(c) Panel mounted multi function energy (voltmeter & ammeter) meter of accuracy CL-1.0 rating including CT of ratio 200/5 - 01 No(B) OUT GOING(a) MCCB 4 Pole 415 Volts 36 KA 160 Amp rating microprocessor adjustable release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -01 No(b) MCCB 4 Pole 415 Volts 36 KA 100 Amp rating microprocessor adjustable release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -02 No(c) MCCB 63 Amp TPN including , nut, bolts, lugs etc -02 Nos |
| 84 | Material and labour Cement concrete (1:2:4) type B -1 using 20 mm graded stone aggregate for pedestal of poles/copping including necessary frame work ,fair finishing to exposed surfaces using extra cement complete form, all as directed and specified |
| 85 | Material and labour for Cement concrete (1:3:6) type C -2 using 40 mm graded stone aggregate for foundation of pole /struts/stay assembly etc complete, all as directed and specified |
| 86 | Material and labour in replacement for prestressed cement concrete poles 9 M long of size 102 mm x 172 mm at top and 102 mm x 279 mm at bottom class-10, conforming to relavent latest IS including dismantling and refixing of cross arm, security light fittings, brackets or any other existing fittings etc connecting, testing including dismantling and removal of broken pole and coping complete all as specified and directed at site. NOTE:- (a) Earthwork, PCC will be measured and paid separately under relevant item.(b) Removal of dismantled items from site are included in rate quoted by the contractor. |
| 87 | Dismantling and Supply, erection and fixing in true vertical position steel tubler swaged pole 09 mtr long type (410-SP-31) conforming to IS -2713 (part 1 and 2) - 1980 complete with cast iron base plate, pole cap, MS bolts, nuts and screws, welded and reduced section and lonitudinal weld seam throughout entire length of pole including material and labour for 2 coats of black bituminous paint throughout internally and externally upto planting depth and remaining exterior position of pole with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. |
| 88 | Dismantling of insulators any type any size from existing poles all as directed. |
| 89 | Supply and fix pin type porcelain insulator, vitreous white brown or green including one galvanised mild steel spindle two GI washer and GI Nuts 100 mm height 65 mm dia for 1100 volts grade complete all as specified. |
| 90 | Supply and fix shackle Type, porcelain, vitreous, white, brown or green insulator 1100 volt grade 75 mm in height and 90 mm dia including galvanised mild steel straps of size 31 x 3 mm, insulator bolt of 12 mm dia, washers and nut complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 91 | Supply and fix shackle Type, porcelain, vitreous, white, brown or green insulator 1100 volt grade 75 mm in height and 90 mm dia including galvanised mild steel straps of size 31 x 3 mm, insulator bolt of 12 mm dia, washers and nut complete all as specified and as directed. Please Enable Macros to View BoQ information |