| 1 | Dismantling of ACSR conductors including jumper from LT pol,e any description complete all as specified and directed. |
| 2 | Dismantling of earth wire including craddles, any description complete all as specified and directed. |
| 3 | Dismantling of insulators any type and size complete all as specified and directed. |
| 4 | Dismantling of cross arms made of MS sections, any description complete all as specified and directed. |
| 5 | Dismantling of poles any type, size and description complete all as specified and directed. |
| 6 | Taking down LT UG cable PVC insuclated bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of any size laid in trenches fixed on wall/ /floor/pole from trenches complete all as specified and directed. |
| 7 | Supply, laying and testing of XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sqmm, 3.5 core complete all as specified and directed. |
| 8 | All as per item No. 7 above but size of 70 sqmm, 3.5 core |
| 9 | All as per item No. 7 above but size of 50 sqmm, 3.5 core |
| 10 | All as per item No. 7 above but size of 35 sqmm, 3.5 core |
| 11 | All as per item No. 7 above but size of 16 sqmm, 4 core |
| 12 | All as per item No. 7 above but size of 10 sqmm, 4 core |
| 13 | All as per item No. 7 above but size of 10 sqmm, 2 core |
| 14 | Taking down LT UG cable and cable protection cover, protection pipe etc, any size and description for re-use including required earthwork (excavation, returning filling and removing surplus excavated soil) complete all as specified and directed.Note:- Obtained material shall be kept in safe custody of Contractor for re-use in respective item here-in-after. |
| 15 | Excavation in trenches in hard/dense of soil not exceeding 1.5 metre wide and not exceeding 1.5metre in depth and getting out complete all as specified and directed. |
| 16 | Excavation in trenches in hard/dense of soil not exceeding 1.5 metre wide and exceeding 1.5m but n.exc. 3.0m in depth and getting out complete all as specified and directed. |
| 17 | Returning filling in with excavated soil, including spreading, leveling watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 18 | Removing excavated materials (soil) not exceeding 50metre and depositing where directed at a level not exceeding 1.5 meter above starting point complete all as specified and directed. |
| 19 | Supply and laying sand cushioning with local dry and clean sand over and under the cable for protection of cable , 80 mm thick before laying the cable 150 mm thick after laying the cable complete all as specified and directed. Note:- Only punned thickness of 180mm shall be measured for payment. |
| 20 | Supply and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size 250mm x 150mm x 40mm complete all as specified and directed. |
| 21 | Supply, installation, testing and commissioning of LT distirbution panel, CPRI approved, factory fabricated, outdoor type with canopy, both side openable including locking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, floor mounting, dust and vermin proof, IP 54, fabricated from 3.15 mm thick CRCA sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos suitable insulated copper bus bar, prewired with appropriate size of copper wiring for control wiring and indication lamp and comprising of the following:- |
| 22 | Item No. 21 Contd...(A) INCOMING (i) MCCB, 4 Pole, 415V, 50HZ, 320 Amps 25 KA electronic /microprocessor -01 No. (B) OUTGOING (i) Digital Multifuction meter with selector switch and three current transformers of suitable ratio and capacity -01 Set(ii) LED Type Phase indicator lamps for three phases - 01 set of three (iii) Insulated copper busbar, each suitable for three phases and neutral -01 Set of four(iv) MCCB, 4 Pole,415V, 50HZ, 200Amps, 16 KA fixed thermal and fixed magnetic -02 No(v) MCCB, 4 Pole,415V, 50HZ, 160Amps, 16 KA fixed thermal and fixed magnetic -02 Nos(vi) Spare space for MCCB of same capacity -01 Nos |
| 23 | Supply, installation, testing and commissioning of LT distirbution panel, CPRI approved, factory fabricated, outdoor type with canopy, both side openable including locking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, floor mounting, dust and vermin proof, IP 54, fabricated from 3.15 mm thick CRCA sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos suitable insulated copper bus bar, prewired with appropriate size of copper wiring for control wiring and indication lamp and comprising of the following:- |
| 24 | Item No. 22 Contd...(A) INCOMING (i) MCCB, 4 Pole, 415V, 50HZ, 320 Amps 25 KA electronic /microprocessor -01 No. (B) OUTGOING (i) Digital Multifuction meter with selector switch and three current transformers of suitable ratio and capacity -01 Set(ii) LED Type Phase indicator lamps for three phases - 01 set of three (iii) Insulated copper busbar, each suitable for three phases and neutral -01 Set of four (iv) MCCB, 4 Pole,415V, 50HZ, 160Amps, 16 KA fixed thermal and fixed magnetic -03 Nos(v) MCCB, 4 Pole,415V, 50HZ, 100Amps, 16 KA fixed thermal and fixed magnetic -03 Nos(vi) Spare space for MCCB of same capacity -01 Nos |
| 25 | Supply, installing, testing and commissioning of factory made (including CPRI type tested certified panel) and tested bus bar chamber outdoor type, made out of 3.15mm CRCA MS sheet and 40x40x5mm MS angle iron frame, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type with apron for cable entry closing locking arrangement of size 450mmx450mmx300mm with 4 Nos, 200 Amps copper bus bar and with 160 Amp MCCB, 4 pole, 36KA, 415 Volt, 50 Hz including excavation, earth work and platform for the bus bar chamber with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate)), 15cm thick in foundation, brick work in CM 1:6 with sub class 'B' old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6 type C-1 (using 20mm graded crused stone aggregate) on top and grouting bolts etc for bus bar chamber. The platform shall be such that it is of a height 45cm above the nearest road level. |
| 26 | Supply, erecting and fixing of steel tubular swaged pole (410 SP – 31) conforming to IS 2713 (part 1 to 3), 9 mtr long with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, including two coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint complete all as specified and directed. (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed).Note: (a) Cost of numbering of pole shall be deemed to included in unit rate.(b) Earth work and PCC will be measured and paid for separately under respective item here-in-after.(c) The pole shall be marked with designation, manufacturer's identification and year of manufacture(d) The Contractor shall submit test certificate of pole. |
| 27 | M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) in foundation of PCC poles/struts complete all as specified & directed. |
| 28 | M&L for plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) in foundation of stay assembly etc complete all as specified & directed. |
| 29 | M&L for plain cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) for coping around poles, including necessary form work finishing even and smooth without using extra cement, complete all as specified & directed. |
| 30 | S&F LED street light fitting sun down 70/72 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistantcomplete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 31 | S&F in repair LED street light fitting sun down 70/72 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistantcomplete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 32 | S&F in repair 3 core, 1.5 sqmm PVC insulated and PVC round sheathed copper conductor (flexible) industrial cable, 1100 volt confirming to IS-694 through GI protection pipe from Junction box to street light fitting including providiing suitable copper lugs complete all as specified and directed. |
| 33 | M & L for carrying out boring under the black top road for crossing of LT cable/protection pipe by any means boring machine or otherwise without damaging black top surface of road suitable for fixing of GI pipe 40 to 100mm bore under the road complete all as specified and directed. |
| 34 | M&L for 40 mm bore or next suitable size ( for LED fittings) light grade GI bracket 1.20 mtr long bent to shape by cutting welding and well finishing including MS clamp of flat iron of size 25x5mm suitable length 2 nos complete for steel tubular poles with nuts bolts and painting with two coats of aluminium paint over a coat of primer on MS clamp complete all as specified & directed. |
| 35 | Taking down old unserviceable junction box and S&F weather proof PVC junction box made out of not less than 2mm thick of size 250x200x100mm (approx) complete with hinged door locking arrangement and consisting of 01 No panel mounted connector 4 pole 32A-01 No, MCB SP 06 Amps, 10 KA-01 No including 02 Nos cable glands suitable for inserting cable not less than 50 sqmm with 01 No of 01mm thick GI plate (150x50mm) having two holes as per the size of cable glands, fixed with cable gland for earth connectivity confirming to IP-65 including fixing on street light pole with MS clamps, bolts, nuts and washers all as specified and directed.Note : The rate quoted shall include cost of MS Clamps, bolts, nuts and washers |
| 36 | M&L for shifting of existing street light fittings/luminaries of any description complete all as specified and directed.Note:- (i) Shifting includes taking down of light fitting from existing location (pole/wall/floor) and re-fix in new location (any location) and its testing complete. (ii) All required T&P shall be arranged by the Contractor and cost of the same shall deemed included in quoted unit rates. |
| 37 | Supply & Fixing steel tubing GI light grade 40 mm dia for cable protection passing under Road/Floor or for fixing on walls complete all as specified and directed. |
| 38 | Supply & Fixing steel tubing GI light grade 50 mm dia for cable protection passing under Road/Floor or for fixing on walls complete all as specified and directed. |
| 39 | Supply & Fixing steel tubing GI light grade 100 mm dia for cable protection passing under Road/Floor or for fixing on walls complete all as specified and directed. |
| 40 | M&L for earthing complete with galvanized mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtr below ground level connected to galvanized iron strip 25x4mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber) 1:2:4 type B-1 using 20mm graded stone aggregate copy shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4 funnel wiht wire gauge of 22 gauge (0.68mm) 8 mesh per liner inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with 8 mm four MS bars @ 80mm centre to centre both ways and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2020) and specified including provision of earth wire protected by 40mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, all excavation and earth work & connectiing the earthing to an earthing test point as specified and testing on complete all as specified & directed. |
| 41 | Laying only LT cable in trenches/ through poles of size upto 150 Sqmm cross sectional area of any description complete all as specified and directed.Note:-(i) Cable obtained from item No. 14 shall be used.(ii) Connected earth work shall be measured and paid separately under resepective item. |
| 42 | Laying only cable protection cover of any description complete all as specified and directed.Note:- Protection cover obtained from item No. 14 shall be used. |
| 43 | Laying/fixing only GI pipe as in cable protection on wall/floor, any description complete all as specified and directed.Note:- Protection pipe obtained from item No. 14 shall be used. |
| 44 | S & F Framed work for base/stand of LT panel distribution board conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 45 | M&L for PCC LT cable route indicators shall be in size of 250x 150 mm at bottom and 200 x 150mm at top and 1250mm height, fabricated in cement concrete of 1:2:4 marking on the indicator complete all as specified and directed. |
| 46 | Disconnecting and taking down old fitting of street light fittings of any wattage or size on pole up to 11 mtr complete all as specified and directed.. |
| 47 | Disconnecting and taking down High mast light up to 25 Mtr Height including taking down mast assembly by making necessary arrangement viz telescoping ladder alongwith all safety arrangement and repositioning of the same after repairing complete all as specified and directed..Note:- Relevent items should be meaured and paid separately. |
| 48 | S & F in repair tubes galvanised of 40 mm bore light grade bent to the shape of bracket 1.2 Mtr in length for mounting of street light fitting and fixed on pole with clamp and nut, bolt and washer with two coat paint complete all as specified and directed. |
| 49 | S & F in repair tubes galvanised of max 56 mm bore light grade bent to the shape of bracket 1.2 Mtr in length for mounting of street light fitting and fixed on pole with clamp and nut, bolt and washer with two coat paint complete all as specified and directed. |
| 50 | S&F in repair junction box Triple Pole and neutral enclosure compression gland 2 with connector and clamp for pole mounting with two nos of nut bolt and washers and socket complete of size not less than 12\\"x10\\"x4\\" complete all as specified and directed. |
| 51 | S&F in repair junction box Single Pole and neutral enclosure compression gland 2 with connector and clamp for pole mounting with two nos of nut bolt and washers and socket complete of size not less than 12\\"x10\\"x4\\" complete all as specified and directed. |
| 52 | S&F in repair 120 watt LED flood light fittings having long life of high power LED with SMD LED exclusive innovative dia cast aluminium IP-66 built in IP-67 electronic driver with APFC, lower THD, open circuit protection, over voltage protection, surge protection up to 10KV with built in SPD & other safety as per IS-15885 part -2, Sec 13, IEC 60598-1 of operating voltage 140-270V avg life 50,000 hours complete manufacture prove all test certificate as per protection for minimum 2 years from manufacturing companies complete all as specified and directed. |
| 53 | S&F in repair 150 watt LED flood light fittings having long life of high power LED with SMD LED exclusive innovative dia cast aluminium IP-66 built in IP-67 electronic driver with APFC, lower THD, open circuit protection, over voltage protection, surge protection up to 10KV with built in SPD & other safety as per IS-15885 part -2, Sec 13, IEC 60598-1 of operating voltage 140-270V avg life 50,000 hours complete manufacture prove all test certificate as per protection for minimum 2 years from manufacturing companies complete all as specified and directed. |
| 54 | S&F in repair LED Street Light fixture with dawn to dusk feature (Sunbeam Sensor) with IP-66 protected die-cast aluminium housing and heat resistive toughened glass in the front and peanut lens for batwing light distribution, higher spacing between poles and maintenance free system. LED shall be having LM-79 and LM-80 complied as per L-70 standard. Maximum power consumption shall not exceed 120 W and system lumens shall not be less than 9,000. Optics shall be properly designed with Polycarbonate Lenses to avoid dark patches on the road. Street light without lenses will not be acceptable. Driver shall be 3 stage \\"Constant Current Constant Voltage\\" with voltage range of 150-270V AC. Output voltage of driver should be complied to Safety Extra Low Voltage norms not exceeding 60 V DC. Note: (i) The item rate shall deem to include provision of weather proof PVC insulated aluminium conductor cable 1.5 Sqmm, 3 core as required.(ii) Contractor shall produce warrinty certificate and LEDs used in the product shall comply with EN-62471 for photo - biological safety and certificate for the same from manufacturer shall be provided. Luminaire manufacturer shall produce certificate of association with LED manufacturer for minimum two years. |
| 55 | S&F in repair LED Street Light fixture with dawn to dusk feature (Sunbeam Sensor) with IP-66 protected die-cast aluminium housing and heat resistive toughened glass in the front and peanut lens for batwing light distribution, higher spacing between poles and maintenance free system. LED shall be having LM-79 and LM-80 complied as per L-70 standard. Maximum power consumption shall not exceed 90 W and system lumens shall not be less than 9,000. Optics shall be properly designed with Polycarbonate Lenses to avoid dark patches on the road. Street light without lenses will not be acceptable. Driver shall be 3 stage \\"Constant Current Constant Voltage\\" with voltage range of 150-270V AC. Output voltage of driver should be complied to Safety Extra Low Voltage norms not exceeding 60 V DC. Note: (i) The item rate shall deem to include provision of weather proof PVC insulated aluminium conductor cable 1.5 Sqmm, 3 core as required.(ii) Contractor shall produce warrinty certificate and LEDs used in the product shall comply with EN-62471 for photo - biological safety and certificate for the same from manufacturer shall be provided. Luminaire manufacturer shall produce certificate of association with LED manufacturer for minimum two years. |
| 56 | S&F in repair LED Street Light fixture with dawn to dusk feature (Sunbeam Sensor) with IP-66 protected die-cast aluminium housing and heat resistive toughened glass in the front and peanut lens for batwing light distribution, higher spacing between poles and maintenance free system. LED shall be having LM-79 and LM-80 complied as per L-70 standard. Maximum power consumption shall not exceed 70 W and system lumens shall not be less than 9,000. Optics shall be properly designed with Polycarbonate Lenses to avoid dark patches on the road. Street light without lenses will not be acceptable. Driver shall be 3 stage \\"Constant Current Constant Voltage\\" with voltage range of 150-270V AC. Output voltage of driver should be complied to Safety Extra Low Voltage norms not exceeding 60 V DC. Note: (i) The item rate shall deem to include provision of weather proof PVC insulated aluminium conductor cable 1.5 Sqmm, 3 core as required.(ii) Contractor shall produce warrinty certificate and LEDs used in the product shall comply with EN-62471 for photo - biological safety and certificate for the same from manufacturer shall be provided. Luminaire manufacturer shall produce certificate of association with LED manufacturer for minimum two years. |
| 57 | M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtr below ground level connected to galvanized iron wire 4mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber) 1:2:4 type B-1 using 20mm graded stone aggregate copy shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4 funnel wiht wire gauge of 22 gauge (0.68mm) 8 mesh per liner inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with 8 mm four MS bars @ 80mm centre to centre both ways and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 15mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, all excavation and earth work & connectiing the earthing to an earthing test point as specified and testing on complete all as specified and directed. |
| 58 | Supply and fix timer switche for street lights control for 3 KW Single Phase rating consists of the following items :- (a) Swadeep-02EC-3KW1P(b) contactor AC3 25 Amps - 01 No (c) Incoming MCB of 25 Amps - 01 No(d) Outgoing MCB of 25 Amps - 01 No(e) complete single phase circuit wiring |
| 59 | Supply and fix time switches for street lights control for 5 KW three Phase rating consists of the following items :- (a) Swadeep-02EC-5KW3P(b) contactor AC3 16 Amps per phase - 03 No (c) Incoming MCB of 20 Amps - 01 No(d) Outgoing MCB of 20 Amps - 01 No(e) complete single phase circuit wiring |
| 60 | Supply, installing, testing and commissioning three phase,415V,50Hz monobloc pump of size 100 mm (Suction) x 80 mm (Delivery), 20 HP capacity, speed 3000 RPM, minimum discharge 19.2 litre per second for 18 metre head , cast iron impeller/diffuser, delivery casing motor body , IP55 protection, class F of insulation, replaceable wearing parts etc, including suitable capacity TEFC motor as per model complete all as specified and directed. |
| 61 | Supplying,installing, testing and commissiong of self supporting totally enclosed mounted on base channel of factory made panel board CPRI approved panel builder factory fabricated made out MS sheet not less than 2.0 mm thick CRCA sheet, dust and vermin proof, hinged smoothly openable front and rear with neoprene rubber gasket, epoxy powder coated including danger plate, earth strip (25x5 mm) connecting provision -02 Nos, ventilation louvers, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers etc panel board suitable for 3 phase 4 wire 415V, 50Hz with 200 Amps rated copper bus bar, general construction confirming to IS:8623 (Part I), IP-54,including mounting on angle iron frame made using angle iron 50mmx50mmx6mm complete all as specified and directed and shall be comprising the following :- |
| 62 | Item No. 59 Contd....INCOMING:-(i) onload changeover switch 100 Amps four pole 415V- 01 No(ii) MCCB with micro processor, based trip 3P,415V 125 Amps 35KA - 1 No(iii) LT copper Bus bar 3 phase 4 wire 200Amps 415 volt - 01 Set.(iv) Volt meter digital type and with selector switch - 01 No.(v) Amp meter digital type CT operated 400/ 5 and selector switch- 01 No(vi) Indicating lamp RYB. - 01 Set.OUTGOING:-(i) MCCB 4 pole 100 Amps 35 KA breaking capacity with Adj thermal and adj magnetic setting - 02No. (ii) Fully automatic star delta Starter 3 Ph,415 Volts, suitable for 20 HP including accessories Make L&T/Havells conforming to IS -13947-4 - 02 Nos |
| 63 | M&L Earthing 32x6mm complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick, burried directly in ground (earth pit not less than 2.25 m below ground level) with the top edge of earth plate at depth not less than 1.5 m below ground level, connected to galvanised eath lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed. |
| 64 | Supply Laying, connecting jointing and testing Centrifugally cast (Spun) Ductile iron Pressure pipe ISI Marked Confirming to IS-8329-2000 (Reaffirmed-2005 Edition 4.1) of size 80mm Dia with Socket Spigot ends Suitable for push on joint (Tyton Joint)Each standerd working length supplied with rubber gaskets duly ISI marked for water supply ,Class-9 with socket with cement mortar lining inside and metallic Zinc coating with finishing lyer of bituminous paint on outside the pipe with out polythylene sleeves but including \\"push on joint\\" supplied with ISI Marked EPDM Rubber gasket confirming to IS-5382-1985 laid in trenches complete all as specified and directed by Engr-in-charge |
| 65 | S&F sluice valves, flanged of class 1.0 PN,80 mm (3”)dia complete all as specified and directed. |
| 66 | S&F Foot Valve conforming to IS 4038, 100 mm (4”) dia complete all as specified and directed.. |
| 67 | S&F 3 core x 16 sqmm Flat copper conductor cable 1100 Volts grade, PVC Insulated & PVC Sheathed conforming to IS- 694/1990 for submersible pump set complete all as specified and directed. |
| 68 | S&F special flexible nylon suction tubing as per site requirement with standard water pressure 10 Kg/cm2 complete all as specified and directed. |
| 69 | Surface excavation n.exc 30cm (not exceeding) and averaging15cm deep and getting out complete all as specified and directed. |
| 70 | M&L for 150mm thick hardcore of gauge n exc. 63 mm, with broken stone or boulders deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 71 | M&L for 150mm thick moorum / red bajri filling in floor and paving laid in layers not exc 25cm thick spread leveled and rammed inlcuding watering all as specified and directed |
| 72 | M&L for 100mm thick PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in sub base of floors complete all as specified and directed. |
| 73 | M&L for 25 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in levelling course of sub base finished even and rough to receive the topping layer complete all as specified and directed. |
| 74 | M&L for 75 mm thick PCC 1:3:6, C1 (using 20mm graded stone aggregate) as in plinth protection finishing cement concrete surface even & smooth without using extra cement and provided with construction joint on the interval not morethan 3.0m and filled with bitumen and sand mortar in 1:3 complete all as specified and directed |
| 75 | M&L for mirror polished Machine cut kota stone slab flooring 20-25 mm thick size not less than 550x1100mm including 20 mm thick screed in CM(1:6) laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified and directed |
| 76 | M&L for machine cut kota stone slab 20-25mm thick as in riser / steps, skirting, dado,cills and pillars laid and jointed with grey cement slurry mixed with pigment to match with the shade of the slab including rubbing and polishing over and including 10 mm thick backing coat in CM (1:6) complete all as specified and directed |
| 77 | M &L for Brickwork with subclass 'B' bricks, straright or curved on plan exc 6m mean radius built in Cement mortar 1:6 complete all as specified and directed. |
| 78 | M&L for 15 mm thick rendering on fair face of brick work or concrete surfaces (on vertical surfaces) in CM 1:4 surface finished even and fair complete all as specified and as directed. |
| 79 | M&L for 10 mm thick rendering on fair face of brick work or concrete surfaces (on vertical surfaces) in CM 1:6 surface finished even and fair complete all as specified and as directed. |
| 80 | M&L for preparation of newly plastered wall surfaces and applying two coats of cement base paint complete all as specified and as directed. |
| 81 | M&L for preparation of newly plastered wall surfaces and applying two coats of white wash complete all as specified and as directed. |
| 82 | S&F structural steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, etc (welded/reviting) confirming to Fe-410-W (Gde-E250) quality 'A' complete all as specified and directed. |
| 83 | M&L for two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces over 10 cm width or girth including preparation of new surfaces complete all as specified and directed. |
| 84 | S&F pre painted galvalume sheet 0.50 mm thick having aluminum zinc coating 150 gsm/ sqm double ribbed trapezoidal profile steel sheet any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws complete all as specified and directed. |
| 85 | S&F of 105 mm X 60 mm size pressed steel frames for door with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc including one shop coat of red oxide primer including cutting holes and making good in P:C:C 1.2.4 type B-1 using 20 mm graded stone aggregate and M&L PCC 1:3:6 type C-0 using 12.5 mm graded store aggregate for filling in pressed steel frame complete all as specified and directed. |
| 86 | S&F 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed all as specified and as directed. |
| 87 | M&L for preparation of new wooden surfaces of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 88 | S&F aluminium alloy, anodized sliding door bolt of 300 mm length with hasp and staple (Bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolt of extruded section or cast aluminium alloy complete all as specified and directed. |
| 89 | S&F 200mm long alumunium anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 90 | S&F aluminum handles cast type, anodized of 150 mm size complete all as specified and directed. Please Enable Macros to View BoQ information |