| 1 | Demolition Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles and M & L for brick work with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cm 1:4 complete all as specified and as directed. |
| 2 | Broken glass coping on top of walls in cement mortar 1:3 including demolition of existing broken coping of any type complete all as specified and as directed. |
| 3 | M & L for cement concrete 1:2:4, Type B–1 using 20mm graded stone aggregate as in bands,sesmic and other similar bands incl,weathering slightly rounded or chamfered angles and throating as directed icl necessary formwork complete all as specified and as directed. |
| 4 | M & L for precast cement concrete 1:2:4 type B0 using 12.5mm graded aggregate louvers and jallies,45mm thick (measured solid) including All moulds set in CM 1:4 including demolition complete all as specified and as directed. |
| 5 | Taking down cement plaster of any description incl raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed. |
| 6 | M & L for 15mm thick rendering in two layers of 10mm thick and 5mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even & fair, using water proofing compound in top layer complete all as specified and as directed. (WPC shall be measured and paid separately as \\"Supply only\\".) |
| 7 | Preparation of new plastered or unplastered surfaces of wall and applying two coats of cement base paint over a coat of alkali-resistant priming coat, complete all as specified and as directed. |
| 8 | Taking down steel gates from its position and repair the same including throughtining alignment properly including welding additional stiffer,brases,pintol hinges locking arrangements etc and erecting the same back in position after applying one coat of synthetic enaemel paint in area of gate n.exc 5.00 Sqmts complete all as specified and as directed. |
| 9 | Dismantling cast iron work in any description |
| 10 | Dismantling fencing/ wire mesh, any type |
| 11 | Supply and fixing Chain link mild steel galvanised fencing, PVC coated 60 x 60 mm aperture and 10 gauge wire fixed with nuts and bolts etc complete all as specified and as directed. |
| 12 | S & F 10mm dia MS round bars including welding with necessary lapping all as directed Gde IS-432 (Part-I) complete all as specified and as directed. |
| 13 | S & F for hand rails, half round or other steel section or core for wooden hand rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or reviting, etc. and similar work conforming to Fe-290 Gde E-165 |
| 14 | S & F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fittrd washers and on hexagonal or square nut, exc 5cm but n exc 10cm long with diameter of shank 11 to 15mm complete all as specified and as directed. |
| 15 | M & L Two coat of synethic enamel paint on new steel surface, including preparation of surface, described over one coat of red oxide for Surfaces of any description, n.exc 10cm in width or girth when uncon nected with other painting or when painted in a different tint complete all as specified and as directed. |
| 16 | M & L for Two coat of synethic enamel paint on new steel surface, including preparation of surface, of any description over 10CM width or girth not otherwise described over one coat of red oxide complete all as specified and as directed. |
| 17 | S & F in repair Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (eachline wire to be measured) including dismantling of Unserviceable barbed wire complete all as specified and as directed. |
| 18 | Supply and fixing punched tape concertina coil 600 to 610mm dia made with high tensile strength galvanized mild steel wire 2.60 mm dia as per IS 4454 strip material (galvanized MS strip as per IS-1730) with angle iron 'V'/'Y' shaped at security wall of approx height 3.00 metre and with 9 horizontal R.B.T and tied with G.I staples and GI clips to retain horizontal including necessary bolts on GI barbed wire tied to angle iron with reinforced barbed tape (RBT)/ spring core 2.6mm dia wire minimum barb 9 mm width, covering per coil 8 to 10 running metres and fixed in position complete all as specified and directed. Note :-(i) The make of concertina coil & barbed wire shall be approved by GE conforming to the specifications before procurement. (ii) Mild steel angle (Y-Shape) shall be measured and paid separately if required at site. |
| 19 | M & L for preparing plastered or unplastered old surfaces of wall by brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and washing rubbing down and applying one coat of cement based paint white or tinted upto triple storey building including scaffolding arrangement complete all as specified and as directed. |
| 20 | Dismantling plain or corrugated steel sheeting, any gauge, thickness as in roof coverings. |
| 21 | S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 22 | Demolition of cement concrete (unreinforced) in ground floors & pavings n.exc 15 cm thickness (below or above ground level), complete all as specified and as directed. |
| 23 | M & L 75mm thick PCC 1:3:6 type C2 (40mm graded Aggregate) as in sub floors, sub bases, floors and pavings, etc complete all as specified and as directed. |
| 24 | Sand filling under floors or in foundation including watering and consolidation, complete all as specified and as directed. |
| 25 | Machine pressed precast concrete interlocking paver block with grey cement and no pigment, any shape, size and design as approved by Engr-in charge confirming to IS 15658-2006 of 60 mm thickness, M-35 grade, complete all as specified and as directed. |
| 26 | Chequered coloured cement concrete tiles glossy finish of size 300 x 300 x 25mm thick, with grey cement and pigment, set, jointed and pointed in neat cement slurry, laid in floors, over and including 15 mm thick screed bed in cement mortar 1:6, complete all as specified and as directed. Please Enable Macros to View BoQ information |