| 1 | Excavation in trenches n.exc 1.5M wide and n.exc 1.5M in depth for pipe line, etc. in soft/ loose soil getting out and levelling of bottom surface to required level complete all as specified and as directed.Note:- Excavation where existing UG Cables/water pipe lines are crossing manual excavation only will be allowed. |
| 2 | Returning filling in, including spreading, leveling, watering and well ramming in layers n.exc 25Cm thick soft / loose soil complete all as specified and as directed. |
| 3 | Removing excavated material (Soils) from site to a distance n.exc 50M away and depositing where directed at a level n.exc 1.5mtr above the starting point complete all as specified and as directed. |
| 4 | Supply & laying 110mm HDPE pipe IS:4984:2016, 8Kg/ cm2 heavy grade PE-80 for cable protection complete all as specified and as directed. |
| 5 | Supply & laying 63mm HDPE pipe IS:4984:2016, 8Kg/ cm2 heavy grade PE-80 for cable protection complete all as specified and as directed. |
| 6 | Boring holes under road pavement by bocky manually in any type of soil upto 150mm bore complete all as specified and as directed. |
| 7 | M & L for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in foundation of brick pillar to support the pipe line including demolition of old PCC and removing the debris from site complete all as specified and as directed. |
| 8 | M & L for Brick work with sub class 'B' bricks straight or curved on plan exc 6M mean radius built in CM (1:4) as in brick pillar of required size and shape to support the pipe line including demolition of old brickwork & removing from site complete all as specified and as directed. |
| 9 | M & L for rendering 10 mm thick with cement mortar (1:6) on fair faces of brick work / concrete surfaces, finished the surface even and fair complete all as specified and as directed. |
| 10 | M & L for pin point the fault by arranging fault locating machine in any size of LT UG cable from any location/ position/ situation, taking down/out the faulty portion of cable, of any length from trenches, jointing with cable jointing kit & testing for satisfactorily serviceable with & including necessary excavation and earth work, sand cushioning and making necessary connections to make it functional complete all as specified and as directed.Note :- (i) Cable jointing kit shall be measured and paid separately.(ii) Old retrieved bricks/cable cover shall be reused(iii) The rates quoted includes excavation & earth work with sand cushioning. |
| 11 | M & L for cable joint kit of following sizes for heat shrinkable straight through joint complete all as specified and as directed. |
| 12 | 4 Core 16 Sqmm |
| 13 | 4 Core 25 Sqmm |
| 14 | 3.5 Core 35 Sqmm |
| 15 | 3.5 Core 50 Sqmm |
| 16 | 3.5 Core 70 Sqmm |
| 17 | 3.5 Core 95 Sqmm |
| 18 | 3.5 Core 120 Sqmm |
| 19 | 3.5 Core 185 Sqmm |
| 20 | 3.5 Core 240 Sqmm |
| 21 | Supply and fixing in replacement Ammeter class 1 and including suitable CT coil in existing LT Panel board fitted complete as per existing model complete all as specified and as directed. |
| 22 | Supply and fixing in replacement Volt meter class 1 and including suitable wiring in existing LT Panel board fitted complete as per existing model complete all as specified and as directed. |
| 23 | Supply and fixing in replacement Multifunction Meter showing parameters like V, A, F, PF, kW, kVA, Run hours, kWh (EB and DG),Old energy, Site selectable kWh / kVAh and including suitable wiring in existing LT Panel board fitted complete as per existing model complete all as specified and as directed. |
| 24 | Supply and fixing in replacement LED indicating lamps (R, Y & B) in existing LT Panel board fitted complete as per existing model complete all as specified and as directed. |
| 25 | Supply and laying LT UG XLPE insulated armoured heavy duty electric, power cable with aluminium conductor, 1100 volts grade laid in trenches, fixed to poles etc. cable including taking down old unserviceable cable of the following size:-Note:- Earth work and excavation etc. will be measured and paid under separate item |
| 26 | 4 Core 10 Sqmm |
| 27 | 4 Core 16 Sqmm |
| 28 | 4 Core 25 Sqmm |
| 29 | 3.5 Core 35 Sqmm |
| 30 | 3.5 Core 50 Sqmm |
| 31 | 3.5 Core 70 Sqmm |
| 32 | 3.5 Core 95 Sqmm |
| 33 | 3.5 Core 120 Sqmm |
| 34 | 3.5 Core 150 Sqmm |
| 35 | 3.5 Core 185 Sqmm |
| 36 | 3.5 Core 240 Sqmm |
| 37 | Taking out existing LT UG cable laid in trenches/ fixed to poles etc. and refixing/ relaying the same after connected repair works cable of following sizes :-Note:- Earth work excavation will be measured and paid separately under relevant items) |
| 38 | 4 core 25 Sqmm to 3.5 core 50 Sqmm |
| 39 | 3.5 core to 70 Sqmm to 240 Sqmm |
| 40 | M & L for preparing old distempered and painted surfaces of walls by washing, rubbing down and stopping of surfaces and applying one coat of distemper oil emulsion (as approved tint) complete all as specified and as directed. |
| 41 | M & L for preparing old painted asbestos cement building board panel surfaces of any description, over 10 cm in width or girth and applying one coat of cement base paint (as approved tint) complete all as specified and as directed. |
| 42 | Supply and fixing in repairs following MCCB's thermal magnetic fixed type including studs and cable lugs in existing LT panel fixing complete all as specified and as directed. |
| 43 | MCCB 100 Amps 16 KA, 4 Pole |
| 44 | MCCB 125 Amps 16 KA, 4 Pole |
| 45 | MCCB 160 Amps 25 KA, 4 Pole |
| 46 | MCCB 200 Amps 25 KA, 4 Pole |
| 47 | MCCB 250 Amps 25 KA, 4 Pole |
| 48 | MCCB 250 Amps 36 KA, 4 Pole |
| 49 | MCCB 320 Amps 36 KA, 4 Pole |
| 50 | MCCB 400 Amps 36 KA, 4 Pole |
| 51 | Supply and fixing in repair Air circuit Breaker (ACB) 4 Pole, 415 V, with microprocessor based Thermal Magnetic Release (Manual Draw out type) of capacity 630 Amps complete all as specified and as directed. |
| 52 | M & L for earthing GI plate 60x60cmx6mm thick electrode and 32x6mm galvanised strip as earthing lead thick buried directly in ground vertically to a depth not less than 2.25 mtr below normal ground level, connected to copper strip of size 32x6mm as earth lead by means of bolts, nuts and washers made out of copper or tinned brass and protection GI pipe of 40mm dia all as specified and testing complete including earthwork, PCC chamber, RCC chamber cover with handle GI watering pipe 20mm dia, GI funnel with wire mesh, magnesium sulphate, salt, charcoal, lugs etc. and method of earthing shall be as per plate No.3 of SSR part -I complete all as specified and as directed. |
| 53 | Cutting the existing bituminous, RCC road, PCC path and interlocking foot path any one and making good with PCC (1:3:6) type C-1 for a width of 0.45 metre and a depth of 0.45 metre complete all as specified and as directed. |
| 54 | M & L 16 Sqmm 4 Core PVC insulated copper conductor, single core cable including lugs in surface/ wall/ floor as required area complete all as specified and as directed. |
| 55 | M & L 25 Sqmm 4 Core PVC insulated copper conductor, single core cable including lugs in surface/wall/floor as required area complete all as specified and as directed. |
| 56 | M & L 50 Sqmm 4 Core PVC insulated copper conductor, single core cable including lugs in surface/wall/floor as required area complete all as specified and directed |
| 57 | M & L 70 Sqmm 4 Core PVC insulated copper conductor, single core cable including lugs in surface/ wall/ floor as required area complete all as specified and as directed. |
| 58 | Taking down old Unserviceable any type changeover switch and S & F On -load change over switches 415V, 50 Hz 63Amps 4 Pole on existing pole/ wall/ Panel Board complete all as specified and as directed. |
| 59 | Taking down old Unserviceable any type changeover switch and S & F On -load change over switches 415V, 50 Hz 100Amps 4 Pole on existing pole/ wall/ Panel Board complete all as specified and as directed. |
| 60 | Taking down old Unserviceable any type changeover switch and S & F On -load change over switches 415V, 50 Hz 200Amps 4 Pole on existing pole/ wall/ Panel Board complete all as specified and as directed. |
| 61 | Taking down old Unserviceable any type changeover switch and S & F On -load changeover switches 415V, 50 Hz 320Amps 4 Pole on existing pole/ wall/ Panel Board complete all as specified and as directed. |
| 62 | S & F LED street light fittings 70 watts 6000K new generation energy saving & environment friendly long life versatile pressure die cast aluminium with Toughened glass in the front & IP 66 roadway luminaire with high power LED as light source and electronic driver electric operated AC single phase 240 volts with all accessories with existing high mast/ building/ pole light fitting in and including reqd three core copper conductor complete taking out existing Unserviceable old one complete all as specified and as directed.Make:- Philips Cat No. BRP501 LED098 CW R3C PSU S1/ Bajaj Cat No. ZELA P 86L WH PO TG SD J/ Wipro Cat No. LR09-781-XXX-57-XX / Havells Cat No. ENDURA SUNDOWN SL 72 W LED 765 SYBO TV |
| 63 | S & F LED street light fittings 90 watts 6000K new generation energy saving & environment friendly long life versatile pressure die cast aluminium with Toughened glass in the front & IP 66 roadway luminaire with high power LED as light source and electronic driver electric operated AC single phase 240 volts with all accessories with existing high mast/building/pole light fitting in and including reqd three core copper conductor complete taking out existing Unserviceable old one complete all as specified and as directed.Make:- Philips Cat No. BRP502 LED126 CW R3C PSU S1 / Wipro Cat No. LR09-102-XXX-57-XX / Orient Cat No. LSFS-90-C-HL |
| 64 | S & F LED street light fittings 120 watts 6000K new generation energy saving & environment friendly long life versatile pressure die cast aluminium with Toughened glass in the front & IP 66 roadway luminaire with high power LED as light source and electronic driver electric operated AC single phase 240 volts with all accessories with existing high mast/building/pole light fitting in and including reqd three core copper conductor complete taking out existing Unserviceable old one complete all as specified and as directed.Make:- Philips Cat No.BRP503 LED168 CW R3C PSU S1/ Wipro Cat No.LR09-132-XXX-57-XX/ Orient Cat No. LSFS-120-C-HL |
| 65 | S & F LED Flood Light fittings 80 watts 6000K new generation energy saving & environment friendly long life versatile pressure die cast aluminium with IP 66 roadway luminaire with high power LED as light source and electronic driver electric operated AC single phase 240 volts with all accessories with existing high mast/ building/ pole light fitting in and including reqd three core copper conductor complete taking out existing Unserviceable old one complete all as specified and as directed.Make:- Havells Cat No. JETA LEGANZA FLS 80W LED 757 P60DT OTG/ Crompton Cat No. LFL-80-CDL/ 60-HPM/ Bajaj Cat No. GLEAM-XT F 96L WH NB-A3 PC SD |
| 66 | S & F LED Flood Light fittings 120 watts 6000K new generation energy saving & environment friendly long life versatile pressure die cast aluminium with IP 66 roadway luminaire with high power LED as light source and electronic driver electric operated AC single phase 240 volts with all accessories with existing high mast/ building/ pole light fitting in and including reqd three core copper conductor complete taking out existing Unserviceable old one complete all as specified and as directed.Make:- Havells Cat No. JETA LEGANZA FLS 120W LED 757 P60DT OTG/ Crompton Cat No. CFS-504-120-57-60D-SL-GL-NSG / Wipro Cat No. LF40-132-060-57-XX/ Bajaj Cat No. GLEAM-XT F 144L WH NB-A3 PC SD |
| 67 | Supply installation, testing and commissioning of LED bollard 10W light fitting long life LED module complete accessories as recommended by manufacturer suitable for 220/ 240 volt AC supply with IP 65 protection including necessary connection etc. complete all as specified and as directed.Make:- Havells TURINBLS10WLED857PSYMTOPC/ Wipro Cat No.LB16-131-XXX-57-08/ Orient Cat No. LLSLBL-10-W |
| 68 | Supply and lay GI tubes, 'light grade' galvanised, with all fittings of bore of tube 50mm laid in trenches for drawing cables under road/ drain crossings etc. complete all as specified and as directed. |
| 69 | Supply and lay GI tubes, 'light grade' galvanised, with all fittings of bore of tube 80mm laid in trenches for drawing cables under road/ drain crossings etc. complete all as specified and as directed. |
| 70 | Preparation of old painted surface of electric poles mild steel tubular type 7.5 to 11Mtr long any type/ make/ model including writing the MES No with white paint over black band of paint at a level of 1.2m above ground level on each pole complete all as specified and as directed. |
| 71 | M & L for cutting chasing of existing pole foundation PCC/RCC for dressing existing/ new LT UG cable and making to good disturbed surfaces with PCC (1:3:6) type C-1 complete all as specified and as directed. |
| 72 | Taking down/ lowering the flood light assembly from high mast light pole by operating motor or by manually by operating handle system for repairing/ replacing the Unserviceable flood light assembly complete or partially as directed as per site requirement including greasing of gear wheels and steel rope for smooth up and down of light assembly and checking of electric connection to motor system/ contacts complete all as specified and as directed. |
| 73 | Labour only for attending and identifying electric supply complaints of day to day maintenance of existing LT Panels/ LT Cable including connecting electrical accessories/ spares of water supply/ Elect supply installations, electrical fitting with lights, short circuits in OTM/Md Accn as per complaint register complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 74 | Labour only for attending and identifying electric supply complaints of day to day maintenance of existing LT Panels/ LT Cable including connecting electrical accessories/ spares of water supply/ Elect supply installations, electrical fitting with lights, short circuits in OTM/Md Accn as per complaint register complete all as specified and as directed. Please Enable Macros to View BoQ information |