| 1 | Sch 'A' |
| 2 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed. |
| 3 | M&L 75 mm thick PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) as in sub base of floor complete all as specfied and directed. |
| 4 | M&L 40mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate) as in flooring finished even and smooth without using extra cement complete all as specified and directed. |
| 5 | M&L 100 mm thick PCC (1:2:4) type B-2 using 40 mm graded crushed stone aggregates as in floor, even and fair all as specified and directed. |
| 6 | M&L Machine pressed precast concrete interlocking paver block with grey cement and pigment, any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade laid over and including 25mm thick sand layer, including necessary cutting and waste as per site requirement complete all as specfied and directed. |
| 7 | M&L Machine pressed precast concrete interlocking paver block with grey cement and pigment, any shape and size confirming to IS 15658-2006 of 80 thickness M-40 Grade laid over and including 25mm thick sand layer, including necessary cutting and waste as per site requirement complete all as specfied and directed. |
| 8 | M&L providing precast cement concrete block type B1, 1:2:4 (20 mm graded crushed stone aggregate) set in CM 1:6 as in kerb stone complete all as specfied and directed. |
| 9 | M&L chequerred cement concrete tiles 30cmx30 cm x25 mm thick set, jointed and pointed in neat cement slurry in floors with grey cement and pigment over and including 20mm thick screed bed in cement mortar 1:6 complete all as specfied and directed. |
| 10 | S&F 38mm width of strip glass dividing strips, 3mm thick and inserted in position to confirm to design complete all as specfied and directed. |
| 11 | M&L Endura ceramic tiles of size 300mmx300mm of 9-10 mm thick laid in floors etc., set and jointed in neat cement slurry and pointed in grey or coloured cement and pigment to match the shade of tile laid over and including 15mm thick bedding layer in cement mortar (1:6) including necessary cutting and waste as per site requirement complete all as specfied and directed. |
| 12 | M&L providing plain cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate in roof kerbs or mud stops, rounded or chamfered on edges complete all as specfied and directed. |
| 13 | Taking down cement plaster of any description on brick or concrete surfaces etc including racking out joints, hacking for key, scrubbing down with water etc. complete all as specfied and directed. |
| 14 | Demolition of brickwork built in cement or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specfied and directed. |
| 15 | M&L brick work with sub class 'B' bricks straight or curved on plan exc. 6 mtr mean radius built in CM 1:6 complete all as specfied and directed. |
| 16 | All as per item No 14 herein before but except bricks complete all as specfied and directed (Old bricks shall be reused). |
| 17 | M&L for brickwork with subclass 'B' bricks, straight or curved on plan exc 6 mtr mean radius in half brick thick built in cement mortar 1:6 complete all as specfied and directed. |
| 18 | M&L rendering 15mm thick on brick work or concrete surface in cement mortar (1:4) and finished even and smooth without using extra cement complete all as specified and directed. |
| 19 | M&L two coats cement base paint including preparation of newly plastered surfaces complete all as specfied and directed. |
| 20 | Demolition of reinforcement cement concrete as in Roofs, floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work (reinforcement cut as reqd to facilitate demolition) complete all as specfied and directed. |
| 21 | S&F precast cement concrete, type B1, 1:2:4 (using 20 mm graded crushed stone aggregate) frame work for precast cement concrete jallies , setting in mortar complete with joints to match complete all as specfied and directed. |
| 22 | S&F precast cement concrete, type B0 1:2:4 (using 12.5 mm graded crushed stone aggregate) louvres and jallies, 25 mm thick (measured in solid ) including all moulding but excluding frame complete all as specfied and directed. |
| 23 | Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specfied and directed. |
| 24 | M&L 16-20mm Granite (of any type) work (table rubbed and polished) in steps, pillars and like over and including 10mm thick rendering in CM 1:4, including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 25 | Dismantling of RCC Post any section, embadded in natural ground incl taking out embadded portion in natural ground complete all as specfied and directed. |
| 26 | Excavation in post holes (or similar holes) each not exceeding 0.50 cubic meter in any type of soil , getting out, returning filling in watering and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm and removing surplus soil to a distance n.exc 50 mtr and making good surface complete all as specified and directed. |
| 27 | M&L PCC 1:3:6, type C-2 using 40mm graded crushed stone aggreage in foundation filling and mass concrete complete all as specified and directed. |
| 28 | S&F post and strut in fencing including cutting tops to shape as directed drilling holes notching for wire flat iron fillet ( for securing wire mesh) including all necessary drilling bolting and rivetting conforming to Fe-290 Gd-165 complete all as specified and directed. |
| 29 | S&F mild steel screw bolt (maching made) with hexagonal or square head at one end and screwed the other with washer n.exc 5 cm long dia bolt 5 to 10mm complete all as specified and directed. |
| 30 | Dismantling of steel barbed wire of any thickness and in any position, complete all as specified and directed. |
| 31 | Supply only Chain link MS galvnised fencing , any size or type, complete all as specified and directed. |
| 32 | Labour for Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed. |
| 33 | S&F galvanised 2 strand, steel barbed wire 2.24mm dia, barbed with 2.24 mm dia barbed at 75 mm spacing c/c and straining and fixing to any type of standard rails, straining bolts, including securing and tying at crossings with provison of galvisnised mild steel wire, staples or steel pins etc., complete all as specified and directed. Note : Net length of wire shall be measured. |
| 34 | M&L two coats of synthetic enamel paint on new surface of steel and iron surfaces of any description over 10 cm width or girth over a coat of red oxide primer including prepration of surface complete all as specified and directed. |
| 35 | M&L for mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hooping as in straightening bars for chain link fencing complete all as specified and directed. Please Enable Macros to View BoQ information |