| 1 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge.D.S.R 14.79 |
| 2 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - chargeNominal concrete 1:4:8 or leaner mix (including equivalent design mix) D.S.R.15.2.2 |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -all work up to plinth level 1: 4 : 8 (1 cement : 4 coarse sand : 8 graded stone ballast aggregate 40 mm. nominal size) (zone-III) Ref. to DSR 4.1.8 |
| 4 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.DSR 15.56 |
| 5 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D- 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane 3 mm thick DSR 14.91.1 |
| 6 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than .08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm 11.41.2 |
| 7 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm DSR 11.47.2 |
| 8 | 12 mm thick Cement plaster in single coat on wall with 1:4 (1 Cement :4 Coarse sand) mortar finished even and smooth including rounded angle upto 80 mm also including supply of all material labour T&P etc. required for proper completion of the work.DSR 13.4.1 |
| 9 | Removing white on colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.DSR 13.88 |
| 10 | Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer , over the plastered wall surface to prepare the surface even and smooth complete. Item no.-13.80 DSR |
| 11 | Finishing walls with Premium acrylic smooth exterior paint with Silicon additives of required shade: New work (Two or more coats applied @ 1.43ltr/10sqm over and including priming coat of exterior primer applied @ 0.90kg/10sqm) (Apex ultima, weather coat all guard) Asian /Berger DSR 13.47.1 |
| 12 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre) DSR 13.41.1 |
| 13 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour Old work (one or more coats) D.S.R 13.81.1 |
| 14 | Dismantling tile work in floors and roofs laid in ement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm 15.23.1 |
| 15 | Disposal of moorum/building/ malba/rubbish /similar unservicealble dismantled of waste material by mechanical transport including loading transporting, unloading to approved municiple. dumping ground for lead beyond 10km for all lifts completion as per direction of E/I. Note- item to be applicable in urban areas having directions for restricted hours for movement /plying of load carrying motor vehicle to 3.5 cum or more. DSR 1.1.18 |
| 16 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand:4 graded stone aggregate) finished with floating coat of neat cement including cement slurry but excluding the cost of nosing of steps etc. complete. (40mm thick with 20mm nominal size stone aggregate) DSR 11.3.1 |
| 17 | Providing and fixing Ist quality ceramic glazed wall tile conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except bargundy bottle green, black as approved by Engineer -in-charge in skirting, risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1cement :3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm , including pointing in white cement mixed with pigment of matching shade complete. DSR 8.31 |
| 18 | Providing and laying Ceramic glazed floor tiles of size 300x300mm (thickness to be specified by the manufacturer) of ist quality conforming to IS:15622, of approved make in all colours, shades except white , ivory, grey, fume red brown, laid on 20mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand ) and jointing with grey cement slurry @3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. DSR 11.38 |
| 19 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with “S” or “P” trap including dismantling of old WC seat and “S” or “P” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material including malba, all complete as per the direction of Engineer-in charge. Orissa Long pattern W.C Pan of size 580x440 mm 14.80.2 |
| 20 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap 17.7.2 |
| 21 | Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required: White glazed fire clay kitchen sink of size 600x450x 250 mm 17.9.1 |
| 22 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 10 litre capacity - White 17.18.1 |
| 23 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet . Sand cast iron S&S as per IS: 1729 17.60.1.2 |
| 24 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc 20 mm nominal dia Pipes D.S.R.18.8.2 |
| 25 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS :8931: 15 mm nominal bore 18.49.1 |
| 26 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete DSR 18.18.3 |
| 27 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/ Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately)Frame size 45 x 70 mm Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made D.S.R 26.86.1 |
| 28 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 30 mm thickD.S.R 26.87.1 |
| 29 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.18.48 |
| 30 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work . 100 mm nominal dia Pipes. D.S.R 18.9.9 |
| 31 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work. DSR 13.99.1 |
| 32 | Providing and laying gang saw cut 18 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20 mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge With granite stone of area less than 0.50 sqm D.S.R 16.86.1 |
| 33 | Treatment of soil under existing floors using chemical emulsion @one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement: 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1 % concentration . DSR 2.35.3.1 Please Enable Macros to View BoQ information |