| 1 | Demolition of Brickwork or stone / boulder masonry, built in cement mortar or cement lime mortar complete all as specified and as directed. |
| 2 | M & L for full or more brick thick Brick work with fly ash brick, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 using old size brick complete all as specified and directed. |
| 3 | Taking down Cement Plaster of any description on internal surfaces on brick or stone walls or concrete surfaces including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed. |
| 4 | M & L for rendering 15 mm thick cement plastering on wall surfaces in two layers (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with liquid water proofing compound in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item). |
| 5 | M & L for rendering 10 mm thick cement plastering on wall surfaces in cement mortar 1:6 on other than fair face of brick-work or concrete surface and finishing the surface even and fair without using extra cement complete all as specified and directed. |
| 6 | M&L for rendering 5 mm thick cement plastering on ceiling surfaces in cement mortar 1:3 on concrete surface, finished the surface even and fair without using extra cement complete all as specified and directed. |
| 7 | Supply only liquid water proofing compound complete all as specified and directed. |
| 8 | M&L for preparation of new plastered surfaces of walls and applying Two or more coats of 100% Premium acrylic exterior emulsion paint having VOC less than 50 m/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including one priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces as ecommended by the manufacturer all as specified and as directed (Note : (i) After drying of primer coat, surface shall be sanded with zero-grade abrasive paper, ensuring primer is not rubbed off. Surface shall be dusted clean. Emulsion paint shall be applied in accordance with manufacturer's instruction.(ii) Rate to include scaffolding and all safety measures at site. ). |
| 9 | M&L for complete removal of existing paint from old decorated surface, preparation of wall surfaces by washing down, rubbing, and removing stains, including application of Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed.(Note: (i) After drying of primer coat, surface shall be sanded with zero-grade abrasive paper, ensuring primer is not rubbed off. Surface shall be dusted clean. Emulsion paint shall be applied in accordance with manufacturer's instruction.(ii) Rate to include scaffolding and all safety measures at site.) |
| 10 | M & L for preparation of new plastered surfaces of walls and applying two coats of plastic emulsion paint of any colour as approved by GE over a coat of primer over two mm thick wall care putty complete all as specified and directed. |
| 11 | M & L for preparation of new plastered surfaces of ceiling and applying two coats of plastic emulsion paint of any colour as approved by GE over a coat of primer over two mm thick wall care putty complete all as specified and directed. |
| 12 | M & L for complete removal of existing treatment from old decorated wall and applying two coats of plastic emulsion paint of any colour as approved by GE over a coat of primer over two mm thick wall acre putty including preparation of surfaces of complete all as specified and directed. |
| 13 | Dismantling wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards /labs /blankets, any thickness, including cover fillets complete all as specified and directed. |
| 14 | S&F false ceiling using anodised aluminium snap grid frame work of size of grid 605 x 605mm with and including hangers of 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long and providing and fixing in repairs of Gypsum Board 12mm thick in ceiling fixed with screw incl GI frame work with standard specification all as specified and directed as per manufacturers instructions and applying two coats of plastic emulsion paint over a coat of primer over 2mm thick wall care putty complete all as specified and directed. |
| 15 | M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed. |
| 16 | M & L for 25 mm thick, plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in padding of concrete or levelling course etc and finished the surface even and rough to receive the topping layer complete all as specified and directed. |
| 17 | M & L for cleaning of surface thoroughly from dust & dirt and cement slurry @ 3 Kg / Sqm shall be applied thoroughly. The provide 10 mm thick screed bed in CM 1:4 mixed with integral water proofing compound as per manufacturer's instructions, after setting and drying cement mortar, the entire surface of the roof slab shall be cleaned thoroughly to remove all loose particle / dust / dirt particle and applying a coat of hot blown grade bitumen primer grade 85 / 25 @ 1.20 Kg Par Sqm shall be applied over priming surface. APP based polymeric membrane of minimum weight 3 Kg/Sqm and a minimum 3mm thick reinforced with polyester non woven fabric (weight not less than 150gms/Sqm) shall be laid on roof and on vertical surface upto and insert in grooves and packed in CM (1:3) with overlaps in membrane 100mm, The over laps shall be sealed by flames or as per manufacturer's instructions. and finally it will be finished with two coats of bituminous based aluminium paint including taking down of existing roof treatment, properly cleaning & drying the concrete surfaces complete all as specified and directed.(Note: Integral water proofing compound shall be measured and paid separately in Supply only item.) |
| 18 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and disposal of debris and rubbish to outside MD land complete all as specified and directed. |
| 19 | M & L for 10cmm thick coloured vitrified tiles, double charged, premium quality, size exceeding 0.42 Sq.m and not exceeding 1 Sq.m, as in floors etc set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile with and including screed bed or bedding layer of 15 mm thick cement mortar 1:6 complete all as specified and directed. (Note: The colour / shade / design of tiles shall be as approved by GE(I).) |
| 20 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 21 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 22 | M&L for 18 to 20 mm thick granite (jet black colour) tiles machine cut as in floors jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing with and including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:6 complete all as specified and as directed. |
| 23 | M & L for glazed, coloured, ceramic, tiles of size (350mm x 250 mm/450mm x 350mm/300mmx450mm) x 6 to 7 mm thick, on vertical surfaces such as skirting, dados etc, including 10 mm thick bedding in cement mortor 1:4 and set & jointed in neat cement slurry & pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 24 | M&L for RCC 1:1.5:3 type A1 (Nominal mix) using 20mm graded stone aggregates as in as in chajja and the like complete all as specified and directed. |
| 25 | M&L for formwork to chulla hoods, chajja etc flat surface , rough finish complete all as specified and directed. |
| 26 | S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 27 | S&F TMT bars 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 28 | Demolition of un-reinforced cement Concrete of any description and in any position not otherwise specifically provided for and removing rubbish to outside MD land complete all as specified and directed. |
| 29 | M & L for 75 mm thick, plain cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 including necessary formwork complete all as specified and directed. |
| 30 | M & L for 25 mm thick, plain cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in flooring, etc and finished the surface even and smooth using extra cement complete all as specified and directed. |
| 31 | S&F 20 mm CPVC pipes SDR 11 shall be fixed with requisite special type of fittings on walls(conceled) & ceiling or laid in floors for internal water supply complete all as specified and directed.(Note: Necessary special fittings shall be measured and paid under relevant supply only items.) |
| 32 | S&F 25 mm CPVC pipes SDR 11 shall be fixed with requisite special type of fittings on walls(conceled) & ceiling or laid in floors for internal water supply complete all as specified and directed.(Note: Necessary special fittings shall be measured and paid under relevant supply only items.) |
| 33 | Supply only 20mm brass elbow for jointing CPVC pipe all as specified and directed. |
| 34 | Supply only 20mm brass elbow (3/4 X ½) for jointing CPVC pipe all as specified and directed. |
| 35 | Supply only 20mm brass Tee for jointing CPVC pipe all as specified and directed. |
| 36 | Supply only 20mm male brass threaded adaptor (MTA/ MBTA) for jointing CPVC pipe all as specified and directed. |
| 37 | Supply only 20mm female brass threaded adaptor (FTA/ FBTA) for jointing CPVC pipe all as specified and directed. |
| 38 | Supply only 20mm Union for jointing CPVC pipe all as specified and directed. |
| 39 | Supply only reducer tee of size 50 x 50 x 20 mm for jointing CPVC pipe all as specified and directed. |
| 40 | Supply only 25mm brass elbow for jointing CPVC pipe all as specified and directed. |
| 41 | Supply only 25mm brass Tee for jointing CPVC pipe all as specified and directed. |
| 42 | Supply only 25mm male brass threaded adaptor (MTA/ MBTA) for jointing CPVC pipe all as specified and directed. |
| 43 | Supply only 25mm female brass threaded adaptor (FTA/ FBTA) for jointing CPVC pipe all as specified and directed. |
| 44 | Supply only 25mm Union for jointing CPVC pipe all as specified and directed. |
| 45 | Supply only 25mm tank adopter for jointing CPVC pipe all as specified and directed. |
| 46 | S & F in repair fancy type Bib taps with wall flange, cromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete complete all as specified and directed. Make: Jaquar Cat Part No. FUS-29037 or Equivalent make as per list of Makes in PS. |
| 47 | S & F in repair fancy type Two way Bib taps with wall flange, cromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.Make: Jaquar Cat Part No. FUS-29041 or Equivalent make as per list of Makes in PS. |
| 48 | S & F in repair table top basin with fixing accessories, vitreous china , size 700 x 435 x 135 mm excluding taps, waste, chain and plug and porcelain stopper but including supply and fixing of 32mm dia bore brass chromium plated waste coupling complete all as specified and directed. Make: Jaquar Cat Part No. ARS-WHT-39903 or Equivalent make as per list of Makes in PS. |
| 49 | S & F in repair soap dispenser with glass bottle complete all as specified and directed. Make: Jaquar Cat Part No. CAN-1135N or Equivalent make as per list of Makes in PS. |
| 50 | S & F in repair glass shelf 600mm long complete all as specified and directed. Make: Jaquar Cat Part No. CPA-1171 or Equivalent make as per list of Makes in PS. |
| 51 | S & F in repair corner glass self (with bracket) complete all as specified and directed. Make: Jaquar Cat Part No. CPA-1173 or Equivalent make as per list of Makes in PS. |
| 52 | S & F in repair aquamax exposed part kit of single lever shower mixer with 3-way diverter (Compatible with ALD-783N) complete all as specified and directed. Make: Jaquar Cat Part No. OPP-15783NKPM or Equivalent make as per list of Makes in PS. |
| 53 | S & F in repair CP Sink Cock with Provision for Connection to RO from rear side & Swinging Spout complete all as specified and directed. Make: Jaquar Cat Part No. FLR5355N or Equivalent make as per list of Makes in PS. |
| 54 | S & F in repair CP Basin Mixter Single Lever Tall Boy with 150mm Extension Body Fixed Spout without Popup Waste System with 600mm Long Braided Hoses Make: Jaquar Cat Part No. FUS-29005NB or Equivalent make as per list of Makes in PS. |
| 55 | S&F in repair Overhead Shower 180mm dia Round Shape Single Flow with Air Effect (ABS Body & Face Plate Chrome Plated) with Rubit Cleaning System complete all as specified & directed.Make: Jaquar Cat Part No. OHS-1755 or Equivalent make as per list of Makes in PS. |
| 56 | S&F in repair Hand Shower 105mm dia Round Shape Single Flow with Air Effect (ABS Body & Face Plate Chrome Plated) with Rubit Cleaning System complete all as specified & directed.Make: Jaquar Cat Part No. OHS-1709 or Equivalent make as per list of Makes in PS. |
| 57 | S&F in repair of CP fancy type angular stop cock 15mm dia with wall flange complete all as specified & directed.Make: Jaquar Cat Part No.FLR-5053N or Equivalent make as per list of Makes in PS. |
| 58 | S&F in repairs PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed. |
| 59 | S&F CP towel ring square with round flange complete all as specified & directed.(Make: Jaquar Cat Part No. ACN-1121N or Equivalent make as per list of Makes in PS.) |
| 60 | S & F in repair Single Towel Rail 600mm Long, Stainless Stee complete all as specified & directed. (Make: Jaquar Cat Part No. ACN 1111SM or Equivalent make as per list of Makes in PS.) |
| 61 | S & F in repair Toilet paper Roll Holder with Stainless Steel Flap complete all as specified & directed. (Make: Jaquar Cat Part No. ACN-1153S or Equivalent make as per list of Makes in PS.) |
| 62 | S & F in repair towel rack with lower hanger (stainless steel) with hook complete all as specified & directed. (Make: Jaquar Cat Part No. AHS-1581H or Equivalent make as per list of Makes in PS.) |
| 63 | S & F in repair Health Faucet spray with 1 Meter Long Easy Flex Tube in Chrome Finish & Wall Hook complete all as specified & directed Make: Jaquar Cat Part No.ALD-565 or Equivalent make as per list of Makes in PS. |
| 64 | S & F in repair bottle trap 32mm size with 300mm & 190mm long wall connection pipes & wall flange complete all as specified & directed Make: Jaquar Cat Part No. ALD-769L300x190 or Equivalent make as per list of Makes in PS. |
| 65 | S & F in repair single piece slim concealed cistern body with installation kit & 'P' type drain pipe connection set for wall hung WC (without flush control plate) complete all as specified & directed Make: Jaquar Cat Part No.JCS-WHT-2400P or Equivalent make as per list of Makes in PS. |
| 66 | S & F in repair rimless Wall Hung WC with inbuilt Jet, PP Soft Close Slim Seat Cover, Hinges, Accessories Set of Size: 355x555x370 mm complete all as specified & directedMake : Jaquar Cat Part No.FLS-WHT-5953JPPSM or Equivalent make as per list of Makes in PS. |
| 67 | Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 68 | Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 69 | Taking up or down 25 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 70 | S&F 600 mm x 450 mm bevelled edge looking mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood & fixed to wooden plugs with chromium plated brass screws & cup washers. Complete all as specified and directed. |
| 71 | Dismantling water tanks exc 500 Litres and n.exc 1000 litres complete all as specified and directed. |
| 72 | S & F rotational moulded polyethylene water storage tanks of capacity 1000 litres, double layer construction, ISI marked ,(Cylindrical vertical with closed top), hoisted and fixed in position including taking down old unserviceable one complete all as specified in SSR Part I and as directed. |
| 73 | M&L for 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement including taking down old unserviceable one Complete all as specified and directed. |
| 74 | Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittings heads, shoes, bends, sawn-necks, etc., including cleaning or refixing or removal to store ( measured overall as fixed along the centre line over fittings and accessories) Complete all as specified and directed. |
| 75 | S&F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls including necessary brackets / clamps complete all as specified and directed. |
| 76 | S&F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls including necessary brackets / clamps complete all as specified and directed. |
| 77 | S&F 75mm bore PVC (SWR) bends any type complete all as specified and directed. |
| 78 | S&F 110mm bore PVC (SWR) bends any type complete all as specified and directed. |
| 79 | S&F 75mm bore PVC (SWR) junction single (single \\"T\\") complete all as specified and directed. |
| 80 | S&F 110mm bore PVC (SWR) junction single (single \\"T\\") complete all as specified and directed. |
| 81 | S&F 75mm bore PVC (SWR) vent cowl complete all as specified and directed. |
| 82 | S&F 110mm bore PVC (SWR)vent cowl complete all as specified and directed. |
| 83 | Taking down chowkats or frames, exc 1.5 but n.exc. 4 Sqm in each with shutter (without taking off shutter from the frame) complete all as specified and directed. |
| 84 | Taking down chowkats or frames, n.exc 1.5 in each with shutter (without taking off shutter from the frame) complete all as specified and directed. |
| 85 | Providing and fixing factory made uPVC white colour sliding window, area not exceeding 2.00 sqm each, three track made of extruded profiles with wall thickness of 2.3mm (+0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners including necessary Hardware like Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories complete all as specified and directed. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured lor payment purpose.) |
| 86 | S & F 5.50 mm thick, sheet glass, ordinary quality and glazing with oil putty in square n.exceeding 0.5 Sqm in each pane complete all as specified and as directed. |
| 87 | S&F 12mm thick toughened & frosted glass with etching and SC frosting as per design for glass partition / door fixed with necessary screws, sealant, stainless steel patch and all fittings etc complete all as specified and directed. |
| 88 | Dismantling wrought iron or mild steel work of any description not otherwise provided for wall complete all as specified and as directed. |
| 89 | S & F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor overall length of cover plate 140 mm complete all as specified and directed. |
| 90 | S & F 35 mm thick, factory made Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 91 | S & F 35mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., divided into squares, with plain, cham-fered or roun-ded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass etc.as specified in SSR Part I, Section 8 clause 8.24 (a) complete all as specified and directed. |
| 92 | M & L for Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed. |
| 93 | S & F 375 mm long brass skeleton tower bolts with cast brass plate and staples and rolled or drawn brass bolts and fixed complete all as specified and directed. |
| 94 | S & F 300 mm long brass sliding door bolt with with sand or die cast brass hasp and staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed complete all as specified and directed. |
| 95 | S&F 100mm long butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. |
| 96 | S&F 150 mm long brass handles, cast type, polished bright complete all as specified and directed. |
| 97 | S & F mild steel bands, straps, supports or stays of rain water, ventilating pipes including bolts, hooks (stay) for large gates, hook and pintel hinges, clamps, hold fasts, wall ties, flat iron fillets for securing wire mesh, wind tie, fan hook and similar work including necessary drilling bolting or riveting etc conforming to Fe – 290 Gde E – 165 complete all as specified and as directed. |
| 98 | M&L plain cement concrete type B0 1:2:4 (using 12.5 mm graded stone aggregate) for fixing holdfast or similar work with necessary formwork complete all as specified and directed. |
| 99 | S & F in repair Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 100 | S & F in repairs Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed. |
| 101 | M&L for providing and injecting chemical emulsion for post construction anti-termite treatment along the external perimeter of wall below concrete or masonry apron using chemical emulsion@ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed. |
| 102 | M&L for providing and injecting chemical emulsion for post construction anti-termite treatment of soil under existing floors using emulsion @ one litre per hole 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed. |
| 103 | Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). |
| 104 | Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30 mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed. (Note: stainless steel butt hinges and necessary S S screws shall be measured and paid separately) |
| 105 | S&F in repairs harrison rails of anodised aluminium alloy, chromium plated with fixing brackets, stops, rollers etc complete all as specified and directed. |
| 106 | M&L for 75mm thick Plain cment concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base of floor complete all as specified and directed. |
| 107 | M & L Machine pressed precast concrete interlocking paver block any shape prepared with grey cement and pigment of size confirming to IS 15658-2006 of 60 mm thick M-35 Grade laid over sand cushioning layer complete all specified and directed. (Note: Sand cushioning shall be measured and paid in relevant item.) |
| 108 | M&L for sand filling under floors or in foundations including watering and consolidation for cushioning complete all as specified and as directed. |
| 109 | M&L endura chequered designed cement concrete tiles of size 600mm x 600 mm x 10mm thick, with grey cement and pigment set, jointed and pointed in neat cement slurry in floors over 15mm thick screed bed or bedding layer in cement mortar 1:4 complete all as specified and as directed. |
| 110 | M & L for plain cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) as in surface channel and drain complete all as specified and directed. |
| 111 | M & L for plain cement concrete 1:3:6 type C1 (using 20 mm graded stone aggregate) as in coping including formwork complete all as specified and directed. |
| 112 | M&L for extra for forming fair finished drain or channel 55cm inner girth in cement concrete using extra cement including forms molds, mitered / stopped ends etc |
| 113 | M&L for providing black FRP gully drain cover of 600 x 600mm complete all as specified and directed. |
| 114 | Taking down carefully copper/aluminum existing point wiring (light/fan/socket or power points) complete incl wooden battens/casing capping or conduit etc (without disturbing existing fittings point wiring etc) and all connected fittings such as switch, socket, ceiling rose, lamp holder, brackets ceiling fittings, bulk head fittings and fan regulator etc and making good to disturbed surfaces of wall floor etc all as directed. |
| 115 | Dismantling of old U/S main switches DBs, MCB enclosures, electric meter, PVC rectangular blocks etc and keeping in safe custody either for reuse or for disposal Including making good to the disturbed surface of wall all as directed. |
| 116 | Taking down ceiling / exhaust fan from existing location and deposited to store complete all as specified and directed. Please Enable Macros to View BoQ information |
| 117 | Taking down ceiling / exhaust fan from existing location and deposited to store complete all as specified and directed. Please Enable Macros to View BoQ information |