| 1 | Excavation in trenches n.exc 1.5m wide and 1.5m depth for foundation etc or for shaft well, cesspits etc n.exc on plan and n.exc 1.5m depth and getting out in hard/dense soil, complete all as specified and as directed. |
| 2 | M&L Plain Cement concrete Type C-2, 1:3:6 (40mm graded aggregate), in foundation, filling and mass concrete, complete all as specified and as directed. |
| 3 | Use & waste of formwork to rough finished surfaces of concrete, form work to sides of plinth beam, footings, bases of columns etc, complete all as specified and directed. |
| 4 | M&L for RCC M-25 (design mix) using 20mm graded aggregate as in fdn, footing, plinth beam, bases for columns etc, complete all as specified and as directed. |
| 5 | Use & waste of formwork to square or rectangle shape and fair finished surfaces of concrete, to sides of pillars, post , struts etc complete all as specified and directed. |
| 6 | M&L for RCC M-25 (design mix) using 20mm graded aggregate as in columns etc, complete all as specified and as directed. |
| 7 | Use & waste Formwork to soffits of fair finished suspended slabs such as roof slabs, floor slabs, landings and similar work; n.exc 200mm thick (Horizontal or sloping) etc, complete all as specified and as directed. |
| 8 | M&L for RCC M-25 (design mix) using 20mm graded aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed. |
| 9 | Use & waste of Formwork finished fair to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc, complete all as specified and as directed. |
| 10 | M&L RCC (design Mix) M-25 (20mm grade aggregate in beam bressummers, limtels over 1.5m span etc, complete all as specified and as directed. |
| 11 | Use & waste of Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide etc, complete all as specified and as directed. |
| 12 | M&L TMT bars 10mm dia and over cut to length, bend to shape required including cranking, bending spirally for hookings for cols, hooking ends and binding with and including mild steel wire (aneeled) not less than 0.9mm dia, complete all as specified and as directed. |
| 13 | M&L TMT bars but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, complete all as specified and as directed. |
| 14 | Returning filling in incl spreading leveling, watering and well ramming in layers n exc 25 cm, complete all as specified and as directed. |
| 15 | Removing of excavated soil not exc 50m and depositing where directed at a level not exc 1.5 M above the starting point, complete all as specified and as directed. |
| 16 | Brick work with sub-class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4, complete all as specified and directed. |
| 17 | M & L Rendering 10 mm thick in cement and sand mortar 1:6 on fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth without using extra cement, complete all as specified and as directed. |
| 18 | M & L Rendering 15 mm thick in cement and sand mortar 1:4 on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing with using integral waterproofing compound @ 3% by weight of cement including finishing the surface even and smooth without using extra cement complete all as specified. (Note - W P C shall be measured and paid separately). |
| 19 | M & L Rendering 5 mm thick in cement and sand mortar 1:3 on fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth without using extra cement on ceiling surfaces, complete all as specified and as directed. |
| 20 | Preparation of newly plastered surfaces of walls and applying two coats of cement base paint surface, complete all as specified and as directed. |
| 21 | M&L for preparing newly plastered surfaces of walls , applying two coats of distemper oil emultion, white ot tinted. Over a coat of white chalk primer surface, complete all as specified and as directed. |
| 22 | M&L for preparing newly plastered surfaces of ceilings , applying three coats of white wash, complete all as specified and as directed. |
| 23 | M & L for hardcore of gauge not exceeding 63 mm of broken stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed. |
| 24 | M&L 75 mm thick Cement concrete type D-2, 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring, complete all as specified and as directed. |
| 25 | M & L 25 mm thick PCC 1:2:4 type B-1, using 20 mm graded stone aggregate, including finishing surface of concrete topping even and rough as sub base/ flooring complete all as specified. |
| 26 | M&L for machine cut kota stone slab flooring 20-25mm thick over 20mm thick cement screed bed in cement mortar 1:3 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to get mirror finish, complete all as specified and as directed. |
| 27 | M&L kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid including 15mm thick rendering in cement mortar (1:4) and jointed including rubbing and polishing to get mirror finish, complete all as specified and as directed. |
| 28 | M & L Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement and sand mortar 1:4, complete all as specified and as directed. |
| 29 | M & L Glazed ceramic tile 450 x 300 x 6-7mm thick (coloured) on vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick plaster in cement and sand mortar (1:4), complete all as specified and as directed. |
| 30 | S & F Roof trusses, trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. |
| 31 | M & L Preparation of new steel surfaces of any description over 10 cm width or girth and priming with red oxide primer and painting with two coats of synthetic enamel paint, complete all as specified and as directed. |
| 32 | M & L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as etc, complete all as specified and as directed. |
| 33 | M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 34 | S & F Solid PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, complete all as shown in drawing of relevant item in MES, schedule Part-II , 2010 as specified. |
| 35 | S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as shown in drawing of relevant item, complete all as specified and as directed. |
| 36 | S&F Steel door including projecting type hinges, steel handle, complete, with glazing bars, dovetailed or welded, complete all as specified and as directed. |
| 37 | S&F steel ventilators with top hung shutter including hinges steel peg stay, squares no.exc 0.50 Sqm in each pane, complete all as specified and as directed. |
| 38 | S & F Butt hinges, 100 mm long medium weight, cold rolled mild steel, ISI marked, complete all as specified and as directed. |
| 39 | S & F 150mm long aluminium anodised, barrel tower bolt ISI marked, complete all as specified and as directed. |
| 40 | S & F 150mm long aluminium anodised cast type alumiinium handle SI marked complete all as specified. |
| 41 | S & F for PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls for 110 mm bore of pipe, complete all as specified and as directed. |
| 42 | S & F for PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75 mm bore, complete all as specified and as directed. |
| 43 | S & F for PVC (SWR) gully trap, plain with grating including jointing with solvent cement 110 mm bore, complete all as specified and as directed. |
| 44 | S&F 110mm bore PVC (SWR) bend, plain including jointing with solvent cement, complete all as specified and as directed. |
| 45 | S&F in repairs for 15 mm bore bib taps, fancy type chormium plated with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule, complete all as specified and as directed. |
| 46 | S&F Water closet (Orrissa pattern) complete including provision of lime concrete bedding including vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) in repairs, complete all as specified and as directed. |
| 47 | S&F PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle, complete all as specified and as directed. |
| 48 | S & F 600mm x 450mm beveled edge mirror of selected quality glass, mounted on 6mm thick commercial quality ply-wood and fixed to wooden plugs with chromium plated brass screws and cup washers complete supplied and fixed, complete all as specified and as directed. |
| 49 | S & F PVC connection 15 mm size, of length 450 mm, with PTMT nuts supplied and fixed, complete all as specified and as directed. |
| 50 | S & F 75mm bore PVC (SWR) pipe single sokete any length with rubber ring joints laid in trenches or in floors, complete all as specified and as directed. |
| 51 | S&F 100mm bore PVC (SWR) 'T 'any radius, complete all as specified and as directed. |
| 52 | S & F 110mm bore PVC (SWR) vent cowl, plain including jointing with solvent cement, complete all as specified and as directed. |
| 53 | S&F 500 Ltrs capacity Rotational moulded polyethylene in white coloured three layered ISI marked water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position, complete all as specified and as directed. |
| 54 | S&F 1000 Ltrs capacity Rotational moulded polyethylene in white coloured three layered ISI marked water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position, complete all as specified and as directed. |
| 55 | S&F second class softwood plain fillets square, rectangular or triangular in section, wrought secured with screws, cross sectional area exc 13 Sqcm and n.exc 25 Sqcm, complete all as specified and as directed. |
| 56 | S&F second class softwood plain fillets square, rectangular or triangular in section, wrought secured with screws, cross sectional area exc 3 Sqcm and n.exc 6 Sqcm, complete all as specified and as directed. |
| 57 | M&L for 4mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face has decorative veneer fixed with nails to timber frame work in ceiling etc, complete all as specified and as directed. |
| 58 | S&F Vitreous China wash basin, wliile, flat back, size 580x450mm excluding taps, waste, chain and plug and porcelain stopper but including brackets etc complete all as specified and directed. |
| 59 | S&F in repairs pillar taps, 15 mm dia cast copper alloy fency type with capstan heads, chromium plated. screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks & fly nuts screwed for iron pipe, complete all as specified and as directed. |
| 60 | S & F soap dish chromium plated, fixed to plugs with chromium plated brass screws, complete all as specified and as directed. |
| 61 | M & L 75mm thick PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in plinth protection and similar works including finishing the surface of concrete topping even & fair, without using extra cement, complete all as specified and as directed. |
| 62 | M&L pre-cast cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, complete all as specified and as directed. |
| 63 | S & F for 4 mm thick figured glass pin head ftype and glazing with oil putty in squares n.exc 0.5 sqm in each pane, complete all as specified and as directed. |
| 64 | Supply only integral water proofing compound, complete all as specified and as directed. |
| 65 | Excavation in post holes (or similar holes) each n.exc 0.5cum getting out, returing, filling in and raming earth/broken rubble mixed with earth around, in layers n.exc 25cm, watering and removing surplus soil to a distance n.exc 50m and making good surface in soft/loose soil, complete all as specified and as directed. |
| 66 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed. |
| 67 | S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-290 (Gde E-165), complete all as specified and as directed. |
| 68 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out all type soil, complete all as specified and as directed. |
| 69 | M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory ompaction by using plate vibrator, filling he joints with fine sand and cutting of paver block as per required size and attern, finishing and sweeping extra sand, complete all as specified and as directed. |
| 70 | M&L for providing cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in roof kerbs or mud stop, rounded or chamfered on edges, complete all as specified and as directed. |
| 71 | M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar (1:6), complete all as specified and as directed. |
| 72 | M&L for brick work with sub class 'B' bricks (Old size) straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6, complete all as specified and as directed. complete all as specified |
| 73 | M & L Rendering 10 mm thick in cement and sand mortar 1:4 on fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth without using extra cement, complete all as specified and as directed. |
| 74 | S&F second class Softwood plain fillets square, rectangular in section exc 6 Sqcm and not exc 13 Sqcm, complete all as specified and as directed. |
| 75 | S&F vitreous china wash down water closet pan (Pedestal pattern) white or coloured excluding flushing cistern and flush pipe and seat cober incl provision of concrete/ white cementing and P or S trap, complete all as specified and as directed. |
| 76 | S&F Tubular towel rail brass chromium plated 20mm dia D-Type 60cm long between flanges, including brackets and fixed to walls, complete all as specified and as directed. |
| 77 | S&F 15mm bore Angle valve, fancy type chromium plated high pressure with crutch or butterfly handle screwed both ends for iron pipe, complete all as specified and as directed. |
| 78 | S&F mild steel framed work such as grills, frame work of water taks FE 290 Gde E-165, complete all as specified and as directed. |
| 79 | S&F 3 layer PPR pipes 25mm dia abore SDR 7.4 & SDR 11 UV staablished and antimicrobial welded having thermal stability for hot and cold water, complete all as specified and as directed. |
| 80 | S&F 3 layer PPR pipes 20mm dia abore SDR 7.4 & SDR 11 UV staablished and antimicrobial welded having thermal stability for hot and cold water, complete all as specified and as directed. |
| 81 | S&F 25mm PPR Gate valve inserted as per requirement of site, complete all as specified and as directed. |
| 82 | S&F 20mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (min weight 20mm-210 gms), complete all as specified and as directed. |
| 83 | S&F CP basin mixer for hot & cold water supply and fixed complete all as specified and as directed. |
| 84 | S&F Vitreous china wash basin 600mmx450mm including waste pipe, coupling and brackets etc, complete all as specified and as directed. |
| 85 | S&F vitreous china urinal, Half Stall type, white (excluding flusing cistern, flush pipe and waste pipe, complete all as specified and as directed. |
| 86 | M&L Brick work with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar (1:4),complete all as specified and as directed. |
| 87 | S&F in repair vitreous china wash basin, white flat back size 550x400 mm plug, porcelain stopper and incl brackets with waste fittings and connection pipe etc including pedestal, complete all as specified and as directed. |
| 88 | M&L for granite (of any type) 20mm thick machine cut, beded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone incluing, complete all as specified and as directed. |
| 89 | M&L for machine pressed precast interlocking paver block any shape any size confirming to -15658 - 2006 of 60mm thickness, M-35 Grade, laid on sand cushioning,with frey cement and no pigment, Complete all as specified and as directed. |
| 90 | M&L sand filling under or in foundations including watering and consolidation, complete all as specified and as directed. |
| 91 | Construction of LLDPE Septic tank septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC (1:4:8) below foundation, Vent shaft, connection etc., complete for 10 users, complete all as specified and as directed. |
| 92 | Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.20 m dia x 4.50 m deep.complete all as specified and shown in drg No.CESZ/TD-1080/2011 |
| 93 | M&L for PCC (1:4:8) type D2 using 40mm graded stone aggregates as in bed to drain pipes including packing under and haunching against the sides of pipes after these are laid tested for 150 mm bore of pipes, complete all as specified and as directed. |
| 94 | M&L 1:2:4 types B-1 (using 20 mm graded stone agg) as in coping etc, complete all as specified and as directed. |
| 95 | M&L Cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in surface channels, drains etc, complete all as specified and as directed. |
| 96 | M & L precast RCC man holes cover in cement concrete 1:2:4 type B-1 using (20mm graded stone aggregate), complete all as specified and as directed. |
| 97 | M&L for point wiring in PVC conduit Concealed with 1.5 Sqmm size multi stranded FRLS copper conductor cable 1.5 Sqm including clamps, screws guttier/plug etc PVC unsheathed cable into and including MS/ GI Sunken board with bakelite sheet and PVC insulated FRLS cable of size 1.5 Sqmm as earth continuity conductor. |
| 98 | (a) One light point/bell/fan point/Ex fan point controlled by one 5 Amps switch one way |
| 99 | (c) One 3 pin 5 Amp switch socket outlet on independent board |
| 100 | (d) One 3 pin 5 Amp switch socket outlet on same board with accessories |
| 101 | M&L for point wiring in PVC conduit Concealed with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including MS/ GI Sunken board with bakelite sheet PVC insulated fire retardant cable of size 2.5 Sqmm as earth continuity conductor. |
| 102 | S&F switch piano Flush type, single pole, one way 6 amp 240 volts, complete all as specified and as directed. |
| 103 | S&F switch piano Flush type, single pole, 15 amp 240 volts, complete all as specified and as directed. |
| 104 | S&F Socket outlet 2 in 1, 3 pin, 5 Amps, flush type, complete all as specified and as directed. |
| 105 | S&F Socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type, complete all as specified and as directed. |
| 106 | S&F Switch socket combination 2 in1, 3 pin,5 and 15Amp flush type,universal complete all as specified and as directed. |
| 107 | Supply and fix ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body, complete all as specified and as directed. |
| 108 | S&F in repairs Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting, complete all as specified and as directed. |
| 109 | S&F in repairs Distribution Board, SPN 2 Way, single door, complete all as specified and as directed. |
| 110 | S&F in repairs Distribution Board, SPN 4 Way, Double door, complete all as specified and as directed. |
| 111 | S & F in repairs MCB, DP 40 Amps 240 Volts B curve, complete all as specified and as directed. |
| 112 | S & F in repairs MCB, SPN 40-63 Amps 240 Volts C curve, complete all as specified and as directed. |
| 113 | S & F MCB SP 6 to 32 Amps, 240 Volts, C Curve complete all as specified and directed. |
| 114 | Supply and fix LED inverter Bulb 12 Watt, complete all as specified and as directed. |
| 115 | S&F LED Lamp 15W, complete all as specified and as directed. |
| 116 | Supply and fixing LED lights fittings 1x20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed. |
| 117 | S&F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed. |
| 118 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed. |
| 119 | Supply and fixing LED luminarie Basic all purpose surface all mounted LED batten with polycarbonate housing and integrated electronic driver of 1x20W, complete all as specified and as directed. |
| 120 | S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300 mm, complete all as specified and as directed. |
| 121 | Supply & Fixing in repair MCB DB 4 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting, complete all as specified and as directed. |
| 122 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SP 6-32 Amp and current carrying capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and directed. |
| 123 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN 32 Amp and current carrying capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and directed. |
| 124 | Material and labour for Supply & fixing 1100 V grade heavy duty PVC insulated aluminium conductor served with an inner sheathing of pvc tape and overall pvc sheathed in service connection suspended by insulating hangers not more than 1mtr apart including 4mm suspension wire with two single core cables flat or circular of size 16 sqmm 2 core, complete all as specified and as directed. |
| 125 | M&L in repairs for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is ilnclusive of necessary earth work, RFR and removal etc |
| 126 | Supply and fix cable PVC insulated unsheathed of size 1.5 Sqmm 3 core copper conductor for service connections of security light fitting, complete all as specified and as directed. |
| 127 | Supply ,Laying ,connecting/ Jointing,charging, testing and commissioning LT cable electric, XLPE insulated, armoured, PVC sheathed, heavy duty, electric cable 1100 Volt grade with stranded aluminum conductor of size 10 sq mm 2 Core, complete all as specified and as directed. |
| 128 | Supply lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade of size 6 Sqmm 2 core, complete all as specified and as directed. |
| 129 | Supply and laying of burnt clay building bricks, sub-classB (old size) Designnation 75 laid flat in tranches for cable protection with wide equal to length of brick, complete all as specified and directed |
| 130 | M & L for dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15cm thick after laying the cable all as specified in clause 19.75 of MES schedule part-1 Note:-Sand shall be fine sand as specified for plastering. |
| 131 | Supply and lay pipe galvanized, \\"Medium class\\", including fittings 25mm, complete all as specified and as directed. Please Enable Macros to View BoQ information |