| 1 | Material & Labour preparation of old plastered or un-plastered surface including brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of white wash on walls complete all as specified and directed. |
| 2 | Preparation of old plastered or un-plastered surface including brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of white wash on ceiling complete all as specified and directed. |
| 3 | Preparation of old decorated surfaces of Wall and applying one coat of plastic emulsion paint complete all as specified and directed. |
| 4 | Preparation of old decorated surfaces of ceiling and applying one coat of plastic emulsion paint complete all as specified and directed. |
| 5 | Preparation of old decorated surface of asbestos based roof or mangalore pattern tile surfaces etc and applying one coat exterior emulsion paint all as specified and directed |
| 6 | Preparation of old surface of wall exposed upto mother surface filled all cracks then applying two coats pidilite product Dr fixit Rain coat over one coat of primer , primer seal complete in all respect as specified as directed. |
| 7 | Preparation of old decorated surfacess of walls/Manglore tiles/AC Sheets and applying one coat of Weather coat paint white or tinted complete all as specified and directed. |
| 8 | Material & Labour preparation of old plastered or un-plastered surface including brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots remove complete existing surface up to mother surface approved by GE than applying two coat of cement base paint and making border or patta on Chhajja, roof projection Column projection , beam projection etc as ordered by Engr-in-Charge with teracotta snowcem dark colour,same materials but diffrent tinted on walls complete all as specified and directed. |
| 9 | All as per item No. 08 above Preparation of old plastered or un-plastered surface and applying one coat of cement base paint on walls complete all as specified and directed. |
| 10 | M&L for preparation of old decorated surfaces of walls by complete removal of existing treatment and applying two coat of oil bound distemper over a coat of 3mm wall care putty complete all as specified and directed. |
| 11 | M&L for preparation of old plastered surfaces of walls and applying one coat of oil bound distemper complete all as specified and directed. |
| 12 | M&L for French polishing on wooden surfaces of any description, width or girth including cleaning and preparing the surfaces including a coat of wood filler on old works with one or more coats on old work etc complete all as specified and directed. |
| 13 | Preparing surfaces of any description of wood, steel, iron, concrete, brick etc andblack paint then writing letter exc 10 cm high but n.exc 30 cm high and width as directed with white synthetic enamel paint of superior grade for writing building numbers in complete all as specified and directed. |
| 14 | M&L for preparation of old painted surfaces of wood and wood based surfaces of any description, over 10 cm in width or girth and apply one coat of synthetic enamel paint complete all as specified and directed. |
| 15 | M&L for preparation of old painted surfaces of steel of any description, over 10cm in width or girth and apply one coat of synthetic enamel paint complete all as specified and directed. |
| 16 | Taking down cement plaster and grit plaster any description on brick or stone walls,ceiling etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 17 | M&L for rendering on fair faces of brick work or concrete surface of wall 10mm thick in CM 1:6 and to be finished even and smooth without using extra cement complete all as specified and directed |
| 18 | M&L for rendering on fair faces of brick work or concrete surface of wall 15mm thick in CM 1:4and to be finished even and smooth without using extra cement complete all as specified and directed |
| 19 | M&L for preparation of new decorated surfaces of walls and applying two coat of oil bound distemper over a coat of wall care putty complete all as specified and directed. |
| 20 | Material & Labour for Preparation of newly plastered surfaces of walls and apply two coat of cement base paint over one coat of primer complete all as specified and directed. |
| 21 | Hacking out old broken glass (any the size quality or description) from wooden or steel frames glazed and incl Sheet glass 3.0 mm thick ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane. all as specified and directed by Engr-in-charge. |
| 22 | S&F 3 mm figured glass, pin head type and glazing with beads\oil putty fixed with m in squares n exc 0.5 sqm in each pane complete all as specified and directed. |
| 23 | Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided for coving,benching,coping etc including removing of rubbish from the premises. |
| 24 | Material and labour for 40mm thick cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in roof padding complete all as specified and directed. . |
| 25 | M&L for 10 mm thick rendering in CM 1:3 mixed with water proofing compound @ 3 % by weight of cement on concrete roof surface to maintain the proper slope of roof surface etc complete all as specified and directed. |
| 26 | M&L for Providing water proofing treatment over cleaned roof surface with super thermo APP modified water proofing memberane comprising of the following for roofs complete all as specified and directed. (a) One layer of APP based polymeric water proofing membrane of weight not less than 3 kg/Sqm consisting 3mm thick reinforced with polyster non woven fabric shall be unrolled surfaces with lap of 100 mm and the over lap shall be sealed by flame. |
| 27 | Supply only liquid water proofing compound |
| 28 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 29 | Dismantling of timber scantlings unframed 40Sq Cm and over in section, in any position complete all as specified and directed. |
| 30 | M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, wind ties etc. conforming Fe 410 -W (GdeE- 250) qualityA complete all as specified and directed. |
| 31 | M&L for Second class hard-wood in scantlings and clean sawn timber framed and fixed complete all as specified and directed. |
| 32 | Dismantling of Asbestos cement (corrugated, semi corrugated,etc) sheets in roof covering complete all as specified and directed. |
| 33 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering incl ridge complete all as specified and directed. |
| 34 | M&L for 6mm thick non asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc Fixed with L-type or J-type or cranked hook bolts complete all as specified and directed. |
| 35 | S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 36 | S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 37 | M&L 0.71 mm Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length andgirth as fixed) |
| 38 | Material and labour for cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in coping, coving etc complete all as specified and directed. . |
| 39 | Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.. |
| 40 | M&L for Brick work using old size of fly ash bricks with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 etc complete all as specified and directed. |
| 41 | M&L for half brick thick wall with FLY ASH Bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete etc all as specified and directed. |
| 42 | M&L for 5mm thick cement plaster in cement mortar 1:3 as on ceiling, soffits of RCC shelves, surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 43 | Prepration of newly plastered surfaces and applying three coat of white wash on ceiling all as specified. |
| 44 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed. |
| 45 | M & L for 4 mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed. |
| 46 | S & F for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centreto centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed. |
| 47 | Post Constructional Anti-termite Treatment Along the external wall below concrete or masonry apron using chemical emulsion at the rate 2.25 liters per linear meter including drilling & plugging holes etc. in apron complete all as specified and directed. |
| 48 | Post Constructional Anti-termite Treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and directed. |
| 49 | Material & Labour for repairing sunken floors leakage by taking out existing nahani trap or floor traps carefully by digging out from its position and provision of new PVC (SWR) nahani trap 100mm dia and joining the same to existing waste pipe and ensure leak proof joints including PCC 1:5:10, Type E-2 and making good the adjoining area to match with existing floor tiles etc with PVC NT / FT, CP steel grating 100 mm dia complete all as specified & directed. |
| 50 | Sunken floor(a) Complete removal of existing raw materials ,WC and demoliton of existing concrete from sunken floor and clean the surface with broom for inspection of Engr-in-Charge(b) Provide 1:3 CM plaster with water proofing compound to sunken portion including walls of sunken portion, thickness of plaster minimum 10 mm in sunken floor with proper slope towards outside when conc is green. (c) Provide bitumen primer and a coat of bitumen at 1.2 Kg/Sqm.(d) Lay polythene film of 200 micron over sunken floor as well as walls.(e) Lay 50mm dia GI pipe spouts resting in lower portion or slope of sunken portion projecting outside through walls.(f) Lay 25 mm thick sand cushion over polythene film.(g) Fill PCC (1:4:8) 200mm in sub base. The floor to be flood tested for 72 hours for water tightness |
| 51 | Taking down eaves gutters and rainwater pipes (any size or pattern ),including all fittings,heads,shoes,bends,swan necks etc.including cleaning or refixing or removal to store complete all as specified and directed. |
| 52 | S&F in repairs 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed. |
| 53 | S&F in repairs 110 mm dia PVC (SWR ) pipes Single socketed in any length with rubber rings joints fixed to walls complete all as specified and as directed. |
| 54 | S&F in repairs 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed. |
| 55 | S&F in repairs 75 mm dia PVC (SWR ) pipes Single socketed in any length with rubber rings ljoits fixed to walls complete all as specified and as directed. |
| 56 | S&F in repairs 110 mm dia PVC (SWR ) bends any radius complete all as specified and as directed. |
| 57 | S&F in repairs 75 mm dia PVC (SWR ) bends any radius complete all as specified and as directed. |
| 58 | S&F in repairs 110 mm dia PVC (SWR ) branch piece,single (single Y) equal or unequal complete all as specified and as directed. |
| 59 | S&F in repairs 75 mm dia PVC (SWR ) branch piece,single (single Y) equal or unequal complete all as specified and as directed. |
| 60 | S&F in repairs 110 mm dia PVC (SWR ) junction,single (single T) equal or unequal complete all as specified and as directed. |
| 61 | S&F in repairs 75 mm dia PVC (SWR ) junction,single (single T) equal or unequal complete all as specified and as directed. |
| 62 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 63 | Demolition of cement concrete un reinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and as directed. |
| 64 | M & L for 25 mm thick PCC 1:2:4 type (B-0) using 12.5 mm graded stone aggregate mixed with water proofing as per manufacturer instruction as in roof padding/ Coving etc at upto Four storey complete all as specified and as directed. . |
| 65 | M&L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in floor finishes 75 mm thick plinth protection laid in panels & finished even and smooth without using extra cement complete all as specified and directed. |
| 66 | M&L for 75 mm thick PCC 1:4:8 type type D2 using 40mm graded stone aggregates as in floors as sub base in patches etc all as specified and directed by Engr-in-charge. |
| 67 | Material and labour for Glazed ceramic tiles of size 350x 250x 7mm/ 450X 350X 7mm thick in vertical surfaces such as dado/ skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 complete all as specified and directed. |
| 68 | M&L for Vitriefied tiles 10mm thick LIGHT SHADE (square/rectangular) polished area of each tiles not exceeding 0.36 sqm in patches in floor including 15mm thick screed bedding layer in CM 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile complete all as specified. |
| 69 | M&L for Vitriefied tiles 10mm thick LIGHT SHADE (square/rectangular) polished area of each tiles not exceeding 0.36 sqm in patchesin skirting/Dado including 10mm thick rendering in CM 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile complete all as specified. |
| 70 | M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or rectangular) area of each tile exc 0.11 Sqm but not exceeding 0.18 Sqm, in floor in patches etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed. |
| 71 | M&L for non skid ceramic tiles/ non skid tiles coloured, area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in patches as per the existing tiles and size as suitable/ matching with the existing tiles in dados/skirting including set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile laid over and including screed bed or bedding layer 10 mm thick rendering in CM 1:4 for laying floor finishes complete all as specified and directed. |
| 72 | M&L for Non skid ceramic joint free coloured tiles 7 to 8 mm thick (Square or rectangular) area of each tile exc 0.18 Sqm but not exceeding 0.36 Sqm, in floor etc in patches set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed.. |
| 73 | M&L for Non skid ceramic joint free coloured tiles 7 to 8 mm thick (Square or rectangular) area of each tile exc 0.18 Sqm but not exceeding 0.36 Sqm, in skiriting/dado etc in patches set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed.. |
| 74 | M&L for ENDURA of Johnson or equivalent outdoor full body Vitrified tiles 30 cm x 30 cm x 10 mm thick, jointed and pointed in neat cement slurry and pointed in white on coloured cement to match as in floors etc laid over in patches and including screed bed or bedding layer of cement mortar 1:6, 15 mm thick etc all complete. |
| 75 | M&L for 9-10 mm thick coloured Vitrified tiles (square/ rectangular) nano tech, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm each in patches at floor set and jointed in neat cement slurry and pointed in white or coloured cement to match ( in patches to match the existing colour /shed) laid over and including 15mm thick Screed bed in CM 1:6 complete all as specified and as directed. |
| 76 | M & L for 20mm thick Granite (zed Black) work (table rubbed and polished) in cooking platforms including bedded in CM 1:4 and jointed with grey cement slurry and pointed to match the shade of granite stone in patches etc complete all as specified and as directed. |
| 77 | M&L for rounding the edges of granite stone slabs open edge, such as in cooking platform, and other similar situations all as specified and as directed. |
| 78 | M&L for providing Machine cut Cudapph stone slab as on cooking platform/shelf 25-40 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete |
| 79 | M&L for chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry with grey cement and no pigment in floors including 15 mm thick screed bed in CM 1:6 for laying floor finish complete all as specified and all as direcred. |
| 80 | M&L for Machine pressed precast Coloured cement concrete rubber moulded interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade etc all complete. |
| 81 | Ditto all as per above items but of 80 mm thick M-40 Grade |
| 82 | M&L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed |
| 83 | Taking down chowkats or frames exc 1.50sqm but n exc 4 sqm with shutter (without taking off shutters from the frames). |
| 84 | Taking down shutter n exc 1.00 sqm of any description |
| 85 | Taking down shutter exc 1.0 sqm but n exc 2.0 sqm each of any description |
| 86 | S & F Steel window with side hung shutters incl projecting type hinges with steel handle , steel peg stay, complete with glazing bars, dovetailed and welded.or ventilators, fixed type, with glazing bar complete all as specified and directed. |
| 87 | S & F Steel window with side hung shutters incl projecting type hinges with steel handle , steel peg stay, complete without glazing bars cooler type window, dovetailed and welded.or ventilators, fixed type, complete all as specified and directed.. |
| 88 | M&L for 35mm thick factory made second class hardwood glazed and skelton door (minimum 3 panel in each shutter ) shutters open rebated and prepared to receive glass gauge etc edges of framing plain chamfered or rounded with cut and mitred beads for securing glass/gauges etc with sash bars, size of members of shutter as specified in SSR Part-I section 8, clause 8.20 (a) complete. |
| 89 | S&F second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 90 | M&L for 30 mm thick second class hard wood flush shutters solid core construction with block board core and plywood face panels commerical type on both side rebated & prepared to receive glass all as specified in SSR Part-I section 8, clause 8.20 (b) complete. |
| 91 | S&F Plain colour 1 mm PVC sheet fixed or laid on to flush door by using rubber based adhesive suppling and fixing at site as per specification |
| 92 | S&F Stainless Steel handles suitable for Aluminium powder coated door shutters not less than 300mm long design/Make as approved by GE (ISI Mark) complete all as specified and directed |
| 93 | S & F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised Width of flaps (when open) in 40mm complete all as specified and directed. |
| 94 | S&F in repair 50 mm size magnet catcher, cupbord lock, safety type, Aluminium with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed. |
| 95 | S&F, Aluminium anodised sections for doors/windows/ventilators with one or more rebates including joining cleat for fixing etc complete with frames, shutters and grills of size directed by Engineer-in-charge including handles, tower bolts, grills, etc complete all as specified and directed. Note:- Floor door spring, sheet glass, wire cloth, lock, etc shall be measured and paid seperately. Please Enable Macros to View BoQ information |
| 96 | S&F, Aluminium anodised sections for doors/windows/ventilators with one or more rebates including joining cleat for fixing etc complete with frames, shutters and grills of size directed by Engineer-in-charge including handles, tower bolts, grills, etc complete all as specified and directed. Note:- Floor door spring, sheet glass, wire cloth, lock, etc shall be measured and paid seperately. Please Enable Macros to View BoQ information |