| 1 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge. |
| 2 | Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge. |
| 3 | Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge. |
| 4 | M&L for Hardcore with broken stones/ boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed by Engineer-in-charge. |
| 5 | M&L for sand filling under floors or in foundations spreading and levelling in layers not exc. 25 cm thick including watering and consolidation or Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as per specified and as directed by Engineer-in-charge. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be measured and paid for. |
| 6 | M&L for PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundations, fillings and mass concrete complete all as per specified and as directed by Engineer-in-charge. |
| 7 | M&L for Reinforced Cement Concrete, M-20 (Nominal Mix) (20mm graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item. |
| 8 | M&L for Reinforced Cement Concrete, M-20 (Nominal Mix) (20mm graded stone aggregate) in Columns, pillars, piers, posts and struts, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item. |
| 9 | M&L for Reinforced Cement Concrete, M-20 (Nominal Mix) (20mm graded stone aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span, chajjas, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item. |
| 10 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge. |
| 11 | M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions, rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge. |
| 12 | M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, chajjas, etc. also splays between floors and beams, etc., rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge. |
| 13 | S&F of TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engineer-in-charge. |
| 14 | S&F of TMT bars 6-8mm dia, cut to length, bent to shape required, in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engineer-in-charge. |
| 15 | S&F of Mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and as directed by Engineer-in-charge. |
| 16 | S&F of mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed by Engineer-in-charge. |
| 17 | M&L for Brickwork with Sub-class 'B' bricks, straight or curved on plan to any radius built and set in cement mortar 1:6, complete all as per specified and as directed by Engineer-in-charge. |
| 18 | M&L for Rendering 10mm thick in cement morter 1:6 on fair faces of brick work or concrete surfaces/ one side of lathing, finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-in-charge. |
| 19 | M&L for Rendering (Externally) 15mm thick in Cement Mortar 1:4 in two layers on other than fair faces Brick Walls/Concrete Surfaces/ other side of lathing, 5mm thick top layer mixed with WPC as per Manufactures instruction, plastered surfaces finished Even and Smooth without using Extra Cement, complete all as specified and as directed by Engineer-in-charge. NOTE: WPC shall be Measured and Paid as ‘Supply only’ under relevant Item. |
| 20 | Supply only Integral waterproofing compound, complete all as specified and as directed by Engineer-in-charge. |
| 21 | M&L for providing 75 mm thick Cement concrete type D-2, 1:4:8 (40mm graded stone aggregate) as in sub-base of floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and rough, complete all as per specified and as directed by Engineer-in-charge. |
| 22 | M&L for providing 75 mm thick Cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) as in floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and fair, complete all as per specified and as directed by Engineer-in-charge. |
| 23 | M&L for providing 40 mm thick Cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) as in base of floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and rough, complete all as per specified and as directed by Engineer-in-charge. |
| 24 | M&L for providing Non-skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc., laid over 20mm thick cement screed 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as per specified and as directed by Engineer-in-charge. |
| 25 | M&L for providing Glazed ceramic coloured tiles in vertical surface (like skirting, dado, etc.) 300x450x 7 mm thick, over 10mm thick cement screed 1:3 set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as per specified and as directed by Engineer-in-charge. |
| 26 | S&F of Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube; complete all as specified and as directed by Engineer-in-charge. |
| 27 | S&F of Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement; complete all as specified and as directed by Engineer-in-charge. |
| 28 | S&F of Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and as directed by Engineer-in-charge. |
| 29 | S&F of 100 mm long Butt hinges, medium weight, mild steel, complete all as specified and as directed by Engineer-in-charge. |
| 30 | S&F of 150 mm long Extruded aluminium alloy handles, febricated type, anodised, complete all as specified and as directed by Engineer-in-charge. |
| 31 | S&F of 200 mm long Aluminium anodised, barrel tower bolts of extruded section, complete all as specified and as directed by Engineer-in-charge. |
| 32 | S&F of 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy, complete all as specified and as directed by Engineer-in-charge. |
| 33 | S&F of 0.50mm thick Pre-painted galvalume aluminum zinc coating GI based semi-corrugated (trapizoidal profile) steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-in-charge. |
| 34 | M&L for preparing newly plastered surfaces of wall and applying three coats of white wash, complete all as specified and as directed by Engineer-in-charge. |
| 35 | M&L for preparation of new or previously un-treated steel/iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of Synthetic enamel paint (1st quality) of any tint over a coat of red oxide primer, complete all as specified and as directed by Engineer-in-charge. |
| 36 | S&F of 600x450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and as directed by Engineer-in-charge. |
| 37 | S&F of 15mm dia galvanised steel tubes, 'medium grade', with all fitting; fixed to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-in-charge. |
| 38 | S&F of 20mm dia galvanised steel tubes, 'medium grade', with all fitting; fixed to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-in-charge. |
| 39 | S&F of Vitreous China wash basin, white, with brackets, flat back, size 550x400mm including cutting for and pinning in ends of brackets or erecting stand, fixing of 15mm dia 450mm long PVC connection pipe and 32mm dia 900mm long PVC Flexible waste pipe with and including 32mm dia Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. complete all as specified and as directed by Engineer-in-charge. |
| 40 | S&F of 15 mm dia fancy type chromium plated Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and as directed by Engineer-in-charge. |
| 41 | S&F of 15 mm dia fancy type chromium plated Pillar taps, cast copper alloy, with capstan heads, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe, complete all as specified and as directed by Engineer-in-charge. |
| 42 | S&F of 15 mm dia fancy type, chromium plated Stop valves/ Angle valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and as directed by Engineer-in-charge. |
| 43 | S&F of 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and as directed by Engineer-in-charge. |
| 44 | S&F of 110mm dia PVC (SWR) bends of any radius with access door, complete all as specified and as directed by Engineer-in-charge. |
| 45 | S&F of 75mm dia PVC (SWR) multi-floor trap, plain with grating including jointing with solvent cement, complete all as specified and as directed by Engineer-in-charge. |
| 46 | S&F of stainless steel Grating doom of 100/125 mm dia with/ without waste hole, complete all as specified and as directed by Engineer-in-charge. |
| 47 | M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and incl PVC casing capping sleeves and caps of adequate width and length with all accessories and fittings like bends, elbow, crosses, etc. with PVC round block and PVC terminal boxes with 3.00mm thick laminated sheet cover for mounting fittings like; switches, sockets, fan regulator, etc. incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly for one light/ fan/ exhaust fan/ bell point controlled by one 1-way switch/ bell push, complete all as per specified and as directed by Engineer-in-Charge. |
| 48 | All as per Item No. 47 here-in-above, but for One 3 pin socket outlet, 5/6 Amps, independent board, complete all as specified and as directed by Engineer-in-charge. |
| 49 | All as per Item No. 47 here-in-above, but for One 3 pin socket outlet, 15/16 Amps, independent board, with cables 2.5 sq. mm size, complete all as specified and as directed by Engineer-in-charge. |
| 50 | S&F of Switch piano, flush type single pole, One way 5/6 Amp, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge. |
| 51 | S&F of Switch socket combination 2 in 1, 3/5Pin, 5/6A flush type, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge. |
| 52 | S&F of Switch socket combination 2 in 1, 3/5Pin, 15/16A flush type, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge. |
| 53 | S&F of ceiling rose surface backelite three terminals, PVC/ polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge. |
| 54 | S&F of Sheet Metal Enclosure MCB DB SPN, 8 way 240 volt, with rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoing MCBs of any type, complete all as specified and as directed by Engineer-in-charge. |
| 55 | S&F of RCCB Double Pole (DP), 40 Amps, breaking capacity 30mA, 240 Volt for fixing on DB’s, 10 KA, 50 Hz, conforming to IS/IEC 61008-1, connecting up and testing, complete all as specified and as directed by Engineer-in-charge. |
| 56 | S&F of MCB Single Pole (SP), 'C' Curve, 6-32 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge. |
| 57 | S&F of surface and wall mounted LED tube light fitting (Box type) 1x 20W, (4 Feet) with aluminium housing & integrated electronic driver, 6500K, 220-240 Volts, AC decorative regal type with and including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engineer-in-charge. |
| 58 | S&F of surface and wall mounted LED light fitting mirror type 1x 10W, (2 Feet) with aluminium housing & integrated electronic driver, 6500K, 220-240 Volts, AC decorative box type with and including LED lamp connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engineer-in-charge. |
| 59 | S&F of Energy saving new generation environmental friendly long life versatile presure die cast aluminium housing IP 66 building security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired and lens embedded PC cover having Bottom opening seperate driver compartment and Impact resistance of IK08 with and including necessary mounting arrangements of bracket made out of 1.2m long 32mm dia light grade GI pipe bend to required shape with necessary fixing clamps (MS flat iron clamp 25x4mm) nut-bolts and applying two coats of aluminium paints on the MS surfaces, complete all as specified and as directed by Engineer-in-charge. |
| 60 | M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (medium grade) and chamber and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs), complete all as specified & testing on completion. NOTE:- (i) Item includes the cost of 1.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr GI earth wire. |
| 61 | All as per Item No. 60 here-in-above, but for 32x6mm GI earth strip protected with 40mm dia (light grade) GI tubing, complete all as specified and as directed by Engineer-in-charge. |
| 62 | Supply, installation, testing and commissioning of Factory made (CPRI Approved) floor mounted Outdoor cubical type LT Panel Board of size 800 X 600 X 450 MM fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame totally enclosed dust and vermin proof both side hinge opening arrangement on front and back, centre openable double door with locking arrangements, cable entry and exit from bottom with cable glands and gaskets, earth strip connections, Bus Bar chamber comprising 4 Nos copper strip bus bars air insulated and PVC sheathed capacity 200 Amps with colour coding mounted on DMC insulator and suitable for 200 Amps with main indication IA - 03 Nos (Make- L&T/ Siemens/ Schneider/ Legrand), Digital ammeter 0-500 Amps with selector switch (Make- L&T/ Siemens/ Schneider/ Legrand), digital voltmeter of 500Volts with selector switch (Make- L&T/ Siemens/ Schneider/ Legrand) and LED/ Neon type indicating lamps panel mounting type RYB-3 Nos (Make- L&T/ Siemens/ Schneider/ Legrand), internal wiring of suitable size to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar, including powder coat painting (RAL-7032) on the surfaces externally & internally including necessary preparation of surfaces and providing PCC (1 : 3 : 6) type C-2 as in foundation all as specified and as directed, comprising of the following :-(a) Internal wiring with 6sqmm single core copper conductor cable/ PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job.(b) Fine wiring with 1.5sqmm single core copper conductor cable for instruments/indicating lamps-1 Job. (c) Bus bar chamber comprising 04 Nos copper strip bus bar mounted on DMC (Dough Moulding Compound) insulator and PVC sheathed of capacity 200 Amps with colour coding for RYB & N - 01 SetINCOMING(d) MCCB 100 Amp, 4 Pole , 415 Volts rating with overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 25KA)Ics=100% of Icu, with Spreader terminal of both side-01 No.OUT GOING(e) MCCB 63 Amp, 3 Pole , 415 Volts rating with overload, short circuit fault protection 3 phase with neutral link specially fixed out going supply (Breaking capacity 25KA)Ics=100% of Icu, with Spreader terminal of both side-02 Nos. (f) MCB Single Pole & Neutral (SPN) 32 Amp, 'C' Curve, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-02 Nos.(g) Automatic star-delta starter of capacity 17.5 HP-02 Nos (Note-Fixing arrangement diagram and line diagram of the panel shall be got approved by accepting officer before panel fabrication). Please Enable Macros to View BoQ information |
| 63 | Supply, installation, testing and commissioning of Factory made (CPRI Approved) floor mounted Outdoor cubical type LT Panel Board of size 800 X 600 X 450 MM fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame totally enclosed dust and vermin proof both side hinge opening arrangement on front and back, centre openable double door with locking arrangements, cable entry and exit from bottom with cable glands and gaskets, earth strip connections, Bus Bar chamber comprising 4 Nos copper strip bus bars air insulated and PVC sheathed capacity 200 Amps with colour coding mounted on DMC insulator and suitable for 200 Amps with main indication IA - 03 Nos (Make- L&T/ Siemens/ Schneider/ Legrand), Digital ammeter 0-500 Amps with selector switch (Make- L&T/ Siemens/ Schneider/ Legrand), digital voltmeter of 500Volts with selector switch (Make- L&T/ Siemens/ Schneider/ Legrand) and LED/ Neon type indicating lamps panel mounting type RYB-3 Nos (Make- L&T/ Siemens/ Schneider/ Legrand), internal wiring of suitable size to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar, including powder coat painting (RAL-7032) on the surfaces externally & internally including necessary preparation of surfaces and providing PCC (1 : 3 : 6) type C-2 as in foundation all as specified and as directed, comprising of the following :-(a) Internal wiring with 6sqmm single core copper conductor cable/ PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job.(b) Fine wiring with 1.5sqmm single core copper conductor cable for instruments/indicating lamps-1 Job. (c) Bus bar chamber comprising 04 Nos copper strip bus bar mounted on DMC (Dough Moulding Compound) insulator and PVC sheathed of capacity 200 Amps with colour coding for RYB & N - 01 SetINCOMING(d) MCCB 100 Amp, 4 Pole , 415 Volts rating with overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 25KA)Ics=100% of Icu, with Spreader terminal of both side-01 No.OUT GOING(e) MCCB 63 Amp, 3 Pole , 415 Volts rating with overload, short circuit fault protection 3 phase with neutral link specially fixed out going supply (Breaking capacity 25KA)Ics=100% of Icu, with Spreader terminal of both side-02 Nos. (f) MCB Single Pole & Neutral (SPN) 32 Amp, 'C' Curve, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-02 Nos.(g) Automatic star-delta starter of capacity 17.5 HP-02 Nos (Note-Fixing arrangement diagram and line diagram of the panel shall be got approved by accepting officer before panel fabrication). Please Enable Macros to View BoQ information |