| 1 | Supply and install 1.5 TR hi wall split units indoor/outdoor complete with cordless remote control unit, twin rotary inverter compressor, 5 star rating,efficient cooling against ambient tempreture up to 55 degree celcius, Minimum 594 CFM, PM 2.5 dust filter and with in built air ioniser for better indoor air quality and ISEER 2.12 of capacity as shown Complete all as Specified & directed by Engr-In-Charge. Make: DAIKIN/ HITACHI/ BLUE STAR/ O-GENERAL/ CARRIER/ VOLTAS/ HAVELLS (LLOYD) |
| 2 | Supply and install in repair Electronic wall mounting type stablizer suitable for AC upto 1.5 TR Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 volt to 250 volt with output voltage stabilized at 230 volt with accuracy of ±2.5% and of capacity 4.0 KVA (Make: AE/V Guard/ other makes specified in Appx 'B' to PS) Complete all as Specified & directed by Engr-In-Charge. |
| 3 | Supply and install 2.0 TR hi wall split units indoor/outdoor complete with cordless remote control unit, twin rotary inverter compressor, 5 star rating,efficient cooling against ambient tempreture up to 55 degree celcius, Minimum 688 CFM, PM 2.5 dust filter and with in built air ioniser for better indoor air quality and ISEER 2.12 of capacity as shown Complete all as Specified & directed by Engr-In-Charge. Make: DAIKIN/ HITACHI/ BLUE STAR/ O-GENERAL/ CARRIER/ VOLTAS/ HAVELLS (LLOYD) |
| 4 | Supply and install in repair Electronic wall mounting type stablizer suitable for AC upto 2.0 TR Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 volt to 250 volt with output voltage stabilized at 230 volt with accuracy of ±2.5% and of capacity 5.0 KVA (Make: AE/V Guard/ other makes specified in Appx 'B' to PS) Complete all as Specified & directed by Engr-In-Charge. |
| 5 | Supply and fix in repair industrial plug and socket with single pole and neutral enclosures with a two pin and earth plug and socket complete with one single pole MCB 20 Amps capacity complete all as Specified & directed by Engr-In-Charge. |
| 6 | Supply and fix in replacement of GI Stand suitable for outdoor of 1.5/2/3.7 Ton AC with and including nut, bolt, dismentel of outdoor after returning gas, fix on GI stand, connect outdoor with indoor, testing and commissioning complete all as specified and as directed by Engr-In-Charge. (Note :- Copper tubes will be paid seperetely if additional required.) |
| 7 | Supply and install inverter Cassette type units indoor/outdoor complete with and including refrigerant pipe,refrigerent, cordless remote control unit, twin rotary compressor, three phase units 415V - 433V, 50 Hz of capacity 3.7 TR or above capacity complete all as specified & directed. Make: DAIKIN/ HITACHI/ BLUE STAR/ O-GENERAL/ CARRIER/ VOLTAS/ HAVELLS (LLOYD) |
| 8 | S&F in replacement of copper tubing suction and liquid line from indoor to out door unit by compressing Ref Gas suitable for split AC of capacity 1.5 TR/ 2.0/3.7 TR including provision of insulation on copper tubing complete all as Specified & directed by Engr-In-Charge. Each RM includes Complete set of suction and discharge line) |
| 9 | Supply, install, testing and commissioning of Packaged AC 11 TR or above capacity, minimum having 132000 Btu/Hr and 4400 CFM Air Cooled with inverter Scroll Compressor, inverter (5.5TR) + Fixed (5.5TR), micro processor control panel with inbuilt logic with LCD display, centrifugal forward curved, double inlet, double width, efficient and eco friendly R410 A refrigerant circuit with 2 Nos of condensing unit, installation on double rubber pads, Nitrogen pressure testing at 5600 Psig hold for 48 hours and vacuming the system at 500 micron, R410A Gas charging as per OEM, air balancing with CFM & testing including necessary plinth for indoor and outdoor unit, all copper pipe for refrigerent, refrigrrent R410 A, Communication cable indoor to outdoor,wiring and drain pipe required for istallation, complete all as specified and as directed. Make : Bule Star, Voltas, Carrier, Daikin, Hitachi. |
| 10 | Supply, install, testing and commissioning of Packaged AC 5.0 TR, 60000 Btu/Hr, 2200 CFM Air Cooled with inverter Scroll Compressor, inverter (5TR), micro processor control panel with inbuilt logic with LCD display, centrifugal forward curved, double inlet, double width, efficient and eco friendly R410 A refrigerate gas, 1 Nos of inverter scroll compressor, indoor unit and 1 Nos of regrigerant circuit with 1 Nos of condensing unit, installation on double rubber pads, Nitrogen pressure testing at 5600 Psig hold for 48 hours and vacuming the system at 500 micron, R410A Gas charging as per OEM, air balancing with CFM & testing including necessary plith for indoor and outdoor unit, all copper pipe for refrigerent, refrigrrent R410 A, Communication cable indoor to outdoor,wiring and drain pipe required for istallation, complete all as specified and as directed.Make : Bule Star, Voltas, Carrier, Daikin, Hitachi. |
| 11 | Supply, install, testing and commissioning of Packaged AC 16 TR, 192000 Btu/Hr, 7200 CFM Air Cooled with inverter Scroll Compressor, inverter (8.0 TR)+Fixed (8.0 TR), micro processor control panel with inbuilt logic with LCD display, centrifugal forward curved, double inlet, double width, efficient and eco friendly R410 A refrigerant circuit with 2 Nos of condensing unit, installation on double rubber pads, Nitrogen pressure testing at 5600 Psig hold for 48 hours and vacuming the system at 500 micron, R410A Gas charging as per OEM, air balancing with CFM & testing including necessary plith for indoor and outdoor unit, all copper pipe for refrigerent, refrigrrent R410 A, Communication cable indoor to outdoor,wiring and drain pipe required for istallation, complete all as specified and as directed.Make : Bule Star, Voltas, Carrier, Daikin, Hitachi. |
| 12 | S&F in repair Refrigerant hard copper piping for any capacity Package AC Air Cooled, Double circuit with and including proper supporting with anchor fastning, threaded rods, MS angle/flat support with all the necessary accessories including copper pipe of size as per OEM complete all as specified & directed. |
| 13 | S&F in repair 40mm dia PVC pipes with necessary fitting with 9mm thick, nitrile rubber insulation with UV protection aluminium foil on sun exposed pipe complete all as specified & directed. |
| 14 | S&F in repair canvas connection with zip to measure machine outlet temperature and CFM complete all as specified & directed. |
| 15 | Supply and fixing/drawing in repair wiring for Circuit / Submain wiring with PVC casing caping of suitable size inclusive of all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories including all fixtures /fittings fixed on wall/ceiling along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface/ recessed as required of 2 x 10 sqmm and 1 x 10 sqmm as earth wire complete all as specified & directed. |
| 16 | S&F in repair GI air tight ducting & plenums fabricated out of prime quality 120 GSM GI sheets comply with BIS code, complete with necessary supports, expansion fastensers, scaffolding to hang the ducts etc of 20 Guage GI Ducting complete all as specified & directed. |
| 17 | S&F in repair acoustic insulation for ducts with 12mm thick fiberglass of density 48 kg/cum & covered with RP tissue & 28 guage perforated aluminium sheet from inside of the duct complete all as specified and as directed. Make: KIMMCO/ UPTWIGA/ equivalent as approved by GE. |
| 18 | S&F in repair GI Duct damper with adjustable handle to control the volume complete all as specified and as directed. Make : Airmaster/ Carryaire / Cosmos / Dynacraft / Trox / Sachins / System air / Maheswari |
| 19 | Supply, installation, commissioning of metal top deep freezer 5 star, single phase 240V, 50 Hz of capacity 320 litres complete all as Specified & directed by Engr-In-Charge. Make : Bluestar, Haier, Godrej, LG. |
| 20 | Supply install and testing Refrigerator Double door with frost free & compressor, 3 Star rating (minimum) vertical door emboss, Transparent accessories Handle, Direct Cool capacity more than 253 liters upto 310 Ltrs, Antibacterial Door Gasket integrated condenser, energetic freezer. Ecofriendly refrigerant complete all as specified & directed. Make: BLUE STAR/ LG/ SAMSUNG/ equivalent as approved by GE. |
| 21 | Supply and install 53 Litres Capacity Desert Cooler PVC Body with superior Cooling Performance. Cooler Must deliver 5000 M3/ Hr air delivery and must have bearing motor for better performance, Honey Comb Pads. Motor Overload protection, 4 way air deflection, ever last Pump Complete all as Specified & directed by Engr-In-Charge. As per Crompton Model - COOL BREE DAC 53 / or equivalent in Havells/Symhony/ equivalent as approved by GE. |
| 22 | Supply only bottled water dispenser, having option of dispensing hot and cold water with cooling capacity 2 ltrs/hr and tank capacity of 1.5 ltrs, heating capacity 5 ltrs/hr and tank capacity 0.8 ltrs, working in R - 134a refrigerant complete all as specified & directed. Make: BLUE STAR/ VOLTAS/ equivalent as approved by GE. |
| 23 | Supply and fix water cooler electric driven ( single phase) having approx storage capaccity of 80 Litre and nominal cooling capacity of 40 Litres per hour and fully stainless steel body complete all as specified & directed. BLUE STAR/ VOLTAS/ equivalent as approved by GE. |
| 24 | M & L for dismanteling & taking down any type AC/Refrigeretor/deep freezer/Deser Cooler/Water Dispensor/Water Cooler etc including indoor and outdoor unit, of any capacity from installed site, transporting to MES store yard and depositing to MES carefully without damaging any part or body complete all as Specified & directed by Engr-In-Charge. |
| 25 | Supply and fixing/drawing in repair wiring for Circuit / Submain wiring with and including PVC casing caping of suitable size inclusive of all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories including all fixtures /fittings fixed on wall/ceiling along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface/ recessed as required of 2 x 4.0 sqmm and 1 x 4.0 sqmm as earth wire complete all as Specified & directed by Engr-In-Charge. |
| 26 | S&F in repair of MCB DB SPN 8 ways single door with 240 Volt, 200 amps rated bus bar with all accessories fixed in the wall including taking old DBs any type and cap and making good and match with the existing surface of wall complete all as Specified & directed by Engr-In-Charge. |
| 27 | S&F in repair of MCB DB SPN 4 ways single door with 240 Volt, 200 amps rated bus bar with all accessories fixed in the wall including taking old DBs any type and cap and making good and match with the existing surface of wall complete all as Specified & directed by Engr-In-Charge. |
| 28 | S&F in repair MCB’s single pole, 6 to 32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting complete all as Specified & directed by Engr-In-Charge. |
| 29 | S&F in repair MCB’s single pole & neutral, 40 to 63 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting complete all as Specified & directed by Engr-In-Charge. |
| 30 | M & L in repair Earthing complete with GI earth plate electrode 60×60cm.× 5 mm thick, burieddirectly in ground (earth pit not less than 2.25 metres deep below groundlevel) with top edge of the plate not less'than 1.5 metres below normal ground level, connected togalvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel including provn of GI protection pipe light grade of 25mm bore and connected to earth wire earthing test point all as shown in electrical plate No.5 of SSR Part-I 2009 and as specified or indicated and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4)type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 15mm bore medium grade, wire mesh and lugs, test point including salt, Coal etc. complete as specified or indicated including testing on completion complete all as Specified & directed by Engr-In-Charge. |
| 31 | M & L in replacement of earthing complete with galvanised steel earth plate electrode 60cmx60cm x 6 mm thick buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to and including GI strip of 32x6mm as earth lead up to 7.5 mtr long fixed by means of bolts, nuts, check nuts and washers etc. of galvanised iron or steel including provn of HDPE protection pipe light grade of 32/40mm bore and connected to earth strip earthing test point all as shown in electrical plate No.5 of SSR Part-I 2009 and as specified or indicated and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 15mm bore Sch.40, wire mesh and lugs, test point etc. complete all as directed by Engr-In-Charge. Note: GI strip exceeding 7.5m long shall be measured & paid seperately. |
| 32 | M & L in repair for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6 mm GI strip with PVC sleeve and welding at joint all as directed by Engr-In-Charge. |
| 33 | RPA TECH FLIGHT & 2257 Storage Hanger FIRE ALARM SYSTEM |
| 34 | Supply & Fix in repair Conventional Type fire alarm panel below specifications: CE Approved,16 X 2 Dot Matrix LCD Display.Standby battery backup with built in charging.Switch Mode Power Supply.Tactile Keypad for easy panel operation.System ON indication.Low Battery visual warning with audible tone.Fire / Fault status in unambiguous colored LED indication.2 programmable relays for fire, supervisory and fault.All zones accept smoke detectors and any normally open contact device.Any Zone can be configured as alarm or supervisory.Zone wise isolation and one man walk test facility.Programmable Aux Outputs.Lamp test & Drill test facility.100 All Events log with RTC.Date / Time / Password configuration.Programmable auto silence facility. Make: Agni/Ravel/Honeywell /equivalent compatible with OEM and as approved by GE. |
| 35 | Supply & Fix in repair Conventional type heat and photo electric smoke Multi detector with mounting base complying with LPCB approved with the specifications as appended below:-a) Power- 24V, ≤ 0.8 mA (Standby Current) ≤5.0mA (Alarm Current)b) Class A2R,c) Indicator- Red Flashes in normal and illuminates in alarm,d) Ingress Protection IP-22 & Material-ABSMake: Agni/Ravel/Honeywell /equivalent compatible with OEM and as approved by GE. |
| 36 | Supply & Fix in repair Conventional type Sounder Cum strobe with mounting base, continuous normal operation for atleast 50 minutes with sound level 65db- 120db measured at 1.5m with sound output variation +5db complying with the specifications as appended below:-a) Power-12/ 24 V DC or 110 /220V AC, 1Ph, AC, 50Hzb) Range- As applicable.c) visual indication.Make: Agni/Ravel/Honeywell/ equivalent compatible with OEM and as approved by GE. |
| 37 | Supply & Fix in repair conventional type resettable manual call point with mounting base complying with LPCB approved with the specifications as appended below:-a) Power- 24V, ≤ 0.6 mA (Standby Current) ≤1.8mA (Alarm Current)b) Class A/Bc) Initiating Mode- Pressing the action plate manually Resuming Mode-Manually Resumed by a Key,d) Ingress Protection IP-43 & Material-ABSMake: Agni/Ravel/Honeywell / equivalent compatible with OEM and as approved by GE. |
| 38 | Supply & Fix in repair 2 core 1.5 Sq MM Armoured copper cable for wiring of all the detectors and fire alarm sub-systems with required PVC conduit pipe or Caping casing. Make: Polycab/Finolex/RR Kabel. |
| 39 | MOTHALA FIRE ALARM SYSTEM |
| 40 | Supply & Fix in Replacement of GST Power Supply Card with below specifications for Storage building, mothala: Standard: EN54 Part 2/4 Main Input Voltage: 100-240VAC, 50/60Hz input Current Rating: 0.5A system Operating Voltage: 24 VDC Nominal Loop Capacity: Loop 1: 235; Loop 2: 242Outputs (3): Fire Alarm Output: 500mA /24Vdc/NO-NC F.P.E. Output: 500mA /24Vdc/NO-NC Sounder Circuit Output: 500mA /24Vdc/NO-NC. Make: GST / equivalent compatible with original OEM and as approved by GE. |
| 41 | Supply & Fix in repair 2 core 1.5 Sq mm Armoured copper cable for wiring of all the detectors and fire alarm sub-systems to lay over head/underground for alarm alert of AFOB & T&C building, Mothala. Make: Polycab/Finolex/RR Kabel. |
| 42 | Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge. |
| 43 | Returning filling in soil and including spreading leveling watering and well ramming in layers n.exc. 25 cm thick |
| 44 | Removing excavated soil to a distance n.exc. 50 mtr and depositing where directed at a level n.exc. 1.5m above the starting points. |
| 45 | M&L for sand cushioning for UG cables using dry sand; gently punning down all as directed and specified. (Note : For measurement purpose punned thickness shall be considered) |
| 46 | M & L in replacement of unreinforced precast concrete cable covers CLASS LV type I, flat size 250 mm x 150mm x 40mm all as directed. |
| 47 | M & L for road cutting to a depth of 60 cm, provision of 40mm dia GI pipe light grade, filling the cutting portion with 30cm thick earth (watered and rammed) and 30cm thick PCC (1:2:4) after laying of pipe, all as directed. |
| 48 | 2257 MAINTENECE HANGER FIRE ALARM SYSTEM |
| 49 | Supply & fix Intelligent Addressable fire alarm control panel with one Loop complying with EN 54 standard & LPCB approved and battery back up with the specifications as appended below:-a) Power- AC 230V, 50Hz, 0.5 Ab) 235 Devices including detectors, minimum 1 loop,c) Relay- Fire Alarm/ F.P.E/ Fault/ Sounderd) configurable for PC Port- RS-232 interface & communication carde) LCD Display and with battery backup of 24 Hours in non alaram condition and 15 Minutes in alaram condition (Battery type 2 X 12V 14AH, sealed typeMake of Battery- Exide/Amron/Solance. Make of panel: GST/ equivalent compatible with existing OEM and as approved by GE. |
| 50 | Supply & Fix electronically addressable intelligent combination of heat and photo electric smoke Multi detector with mounting base complying with EN 54 standard and LPCB approved with the specifications as appended below:-a) Power- 24V, ≤ 0.8 mA (Standby Current) ≤5.0mA (Alarm Current)b) Class A2R,c) Indicator- Red Flashes in normal and illuminates in alarm,d) Ingress Prote. Make: AGNI/HONEYWELL/ GST/ equivalent compatible with OEM and as approved by GE. |
| 51 | Supply & Fix electronically addressable intelligent Sounder Cum strobe with mounting base, continuous normal operation for atleast 50 minutes with sound level 65db- 120db measured at 1.5m with sound output variation +5db complying with the specifications as appended below:-a) Power-12/ 24 V DC or 110 /220V AC, 1Ph, AC, 50Hzb) Range-1000 mc) visual indication.Make: Agni/Honeywell/GST/ equivalent compitable with OEM and approved by GE. |
| 52 | Supply & Fix intelligent loop isolator with mounting base complying with EN 54 standard and LPCB approved with the specifications as appended below:-a) Power- 24V, ≤ 3 mA (Standby Current) ≤15mA (Action Current)b) Class A ,c) Initiating Mode- Yellow flashes when polling, illuminates in action,d) Ingress Protection IP-30 & Material-ABSMake: Agni/Honeywell/GST/equivalent compatible with OEM and as approved by GE. |
| 53 | Supply & Fix in Replacement of electronically addressable intelligent resettable type manual call point with mounting base complying with EN 54 standard and LPCB approved with the specifications as appended below:-a) Power- 24V, ≤ 0.6 mA (Standby Current) ≤1.8mA (Alarm Current)b) Class A ,c) Initiating Mode- Pressing the action plate manually Resuming Mode-Manually Resumed by a special Key,d) Ingress Protection IP-43 & Material-ABSMake: Agni/Honeywell/GST/equivalent compatible with OEM and as approved by GE. |
| 54 | Supply & Fix Communication card for programming of detectors and other devices in FACP Comm.Interface: USB interfaceComm.Distance <15m <5mBaud Rate 2400bpsAmbient Temperature 0℃~+40℃Relative Humidity ≤95%, non condensing. Make: Agni/Honeywell/GST/ /equivalent compatible with OEM and as approved by GE. |
| 55 | Supply & Fix 2 core 1.5 Sq MM flexible copper cable for wiring of all the detectors and fire alarm sub-systems with required PVC conduit pipe or Caping casing. Make: Polycab/ Finolex/ RR Kabel/ equivalent as specified. |
| 56 | M & L for software Logic deveplopment for Fire alarm control panel which includes the development of logic for false alarm which comes from Addressable fire alarm control panel and addressing of all the detectors, sounders, MCPs room wise for troubleshooting in alarm condition. Make: Agni/Honeywell/GST/ equivalent compitable with OEM and approved by GE. |
| 57 | Supply & Fix Ultraviolet Flame Detector with below specifications: Operating Voltage Loop: 24V(12V~28V)Standby Current ≤2mA, Action Current ≤2.5mAAlarm Clear Instantaneous power out (5s MAS, 2.5VDC MAX)Power-up Time ≤5sIndicator Red. Flashes in polling, Illuminates steadily in alarm.Two wire for loop, Programming Method Electronically addressed.Code Range One address within 1~242Spectral Response Range 185nm~260nm Detection Distance Level I: 25m Level II: 17m Level III: 12mOperating Temperature -20℃~+55℃Relative Humidity ≤95%, non condensingDimension Diameter: 103mm, Height: 53.5mm (with base), Diameter: 100mmHeight: 41mm (without base), Ingress Protection Rating IP21Material and Color of Enclosure ABS, white (RAL 9016), Weight About 110gMounting Hole Distance 45mm~75mm Make: Honeywell/Ravel/GST/ equivalent compatible with OEM and as approved by GE. |
| 58 | SCADA |
| 59 | Supply, Installation, Testing & Commissioning of flowchart based programmable RTU for Monitoring Temperature & Humidity for Package Type/chiller type AC. PVC enclosure to mount RTU inside the existing panel all as directed with following specifications:-(a) Input Output as per requirement for measuring temperature and humidity(b) RS485 ports to receive data from field transmitter & transmit data from RTU(c) Isolated Analog Inputs for monitoring of Temperature & humidity(d) With optional Local Display, membrane key board and data storage to feed input in RTU.Make- Emtech/RDS/ equivalent compatible with OEM and as approved by GE. |
| 60 | Development, Installation, Testing & Commssioning of SCADA continuous polling software Version for display of live data in PC with required tags for Central Monitoring through wired communication for Master Control Station (PC). Data received from AC1 & AC2 building will be fetched by software, displayed live and also stored for future use. The job also includes SITC charges of entire system all as directed. |
| 61 | Supply, Installation, Testing & Commissioning in repiar of RTD/HUMIDITY SENSOR for the measurement of room temperature with installation accessories (to be installed inside room to measure temperature) Make: Waree/ RADIX/ Wika/ equivalent compatible with OEM and as approved by GE. Please Enable Macros to View BoQ information |