| 1 | Taking down ceiling fan/Exhaust fan/Air circulating fans/geyser, sealing cable end. Dismantling blades including regulator, louvers, geyser units, associated electric points, removing fan and blades deposit to MES store complete all as specified and directed. |
| 2 | M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, concealed conduit wiring in walls and surface with GI saddles GI screws, rawal plugs in ceiling or roof if not possible including Tee, Junction boxes and provision of flush metal boxes, inner and outer plate suitable for modular switch, socket and fan regulator as per site requirement and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified and directed. for one light/Fan point controlled by one Switch. |
| 3 | Complete all as per Srl item No 2 above for point wiring for 5 pin switch socket outlet, 5/6 Amps on same board complete all as specified and directed. |
| 4 | Complete all as per Srl item No 2 above for point wiring for 5 pin switch socket outlet, 5/6 Amps on independent board complete all as specified and directed. |
| 5 | Complete all as per item No 2 above for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete all as specified and directed. Make of cable and conduit: Havells/Gemscab/RR cable |
| 6 | S&F Modular switch piano single pole one way 6 amp complete all as specified and directed. Make -Legrand / Anchor Penta / Havells as approved. |
| 7 | S&F Modular switch piano single pole one way 16 amp complete all as specified and directed. Make - Legrand / Anchor Penta / Havells as approved. |
| 8 | S&F Modular socket outlet 2/3 pin combined 2 module 6/16 amp complete all as specified and directed. Make -Legrand / Anchor Penta / Havells as approved. |
| 9 | S&F Modular socket outlet 2/3 pin combined 2 module 6 amp complete all as specified and directed. Make -Legrand / Anchor Penta / Havells as approved. |
| 10 | S&F LED luminaire 2'x2' feet, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver threecore flexible copper conductor cases of suitable size complete all as specified and directed. |
| 11 | Dismantling of old unserviceabe central AC system of any capacity and connected items such as AHU/water pump sets, cooling towers, ducting and electrical conections/ducting etc including all acessories and deposting the same in MES store yard complete all as specified and directed. |
| 12 | Dismantling, removing and shifting for BER window AC's/ Split AC's of any capacity from any existing position and shifted/deposited safely to MES store including making necessary PCC, brick and plastering work to cover the exposted portion of with matching colour etc complete all as specified and directed. |
| 13 | Design, Supply, Installation, Testing & Commissioning of Chilled Water type Central AC Plant of Capacity 2 x 37.5 TR working unit & 1 x 37.5 TR standby unit along with winter heating and humidification with following components and scope of work at Micro Lab, IRDE:-(a) Water Cooled Chilling Machines - 2 x 37.5 TR (Working) + 1 x 37.5 TR (Standby) scrolled type with hermetically sealed compressors, multi circuit Dx chiller,water cooled S&T condenser, Microprocessor based control panel,suitable for R-407 C / R410a Refrigerant, Shell & Tube Insulated Evaporator,Expansion Device, Suitable capacity Control Mechanism(b) Chilled Water Pump Set centrifugal mono block type with standby (c) Condenser Water Pump Set centrifugal mono block type with standby (d) Hot Water Pump Set centrifugal mono block type with standby (e) Air Handling Unit double skin floor mounted type with suitable CFM capacity and quantity(f) Electric Hot Water Generator for Winter Heating Kit and Monsoon Reheating complete with all controls and control wiring etc.(g) Cooling Tower with suitable water capacity(h) Motor control centre for AC Palnt with suitable number of incoming and outgoing MCCBs with necessary provision of intelligent meter and safety protection(j) Motor control centre for AHU with suitable number of incoming and outgoing MCCBs with necessary provision of intelligent meter and safety protection(k) Electrical cables for interconnection of Chillers, Hot water generators, AHU, Pumps etc with Earthing (strip/wire type)(l) Chilled and Hot water pipes of suitable sizes and Class with Valves, Strainers, flanges and fittings including necessary insulation material for pipes(m) HDPE Expansion Tank, Make Up Tank of suitable capacity(n) Air distribution for building through duct along with grills, diffusers for both supply and return air with necessary thermal insulation, fire dampers, actuators control panel, wiring etc. Please Enable Macros to View BoQ information |
| 14 | Design, Supply, Installation, Testing & Commissioning of Chilled Water type Central AC Plant of Capacity 2 x 37.5 TR working unit & 1 x 37.5 TR standby unit along with winter heating and humidification with following components and scope of work at Micro Lab, IRDE:-(a) Water Cooled Chilling Machines - 2 x 37.5 TR (Working) + 1 x 37.5 TR (Standby) scrolled type with hermetically sealed compressors, multi circuit Dx chiller,water cooled S&T condenser, Microprocessor based control panel,suitable for R-407 C / R410a Refrigerant, Shell & Tube Insulated Evaporator,Expansion Device, Suitable capacity Control Mechanism(b) Chilled Water Pump Set centrifugal mono block type with standby (c) Condenser Water Pump Set centrifugal mono block type with standby (d) Hot Water Pump Set centrifugal mono block type with standby (e) Air Handling Unit double skin floor mounted type with suitable CFM capacity and quantity(f) Electric Hot Water Generator for Winter Heating Kit and Monsoon Reheating complete with all controls and control wiring etc.(g) Cooling Tower with suitable water capacity(h) Motor control centre for AC Palnt with suitable number of incoming and outgoing MCCBs with necessary provision of intelligent meter and safety protection(j) Motor control centre for AHU with suitable number of incoming and outgoing MCCBs with necessary provision of intelligent meter and safety protection(k) Electrical cables for interconnection of Chillers, Hot water generators, AHU, Pumps etc with Earthing (strip/wire type)(l) Chilled and Hot water pipes of suitable sizes and Class with Valves, Strainers, flanges and fittings including necessary insulation material for pipes(m) HDPE Expansion Tank, Make Up Tank of suitable capacity(n) Air distribution for building through duct along with grills, diffusers for both supply and return air with necessary thermal insulation, fire dampers, actuators control panel, wiring etc. Please Enable Macros to View BoQ information |