Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CHIEF ENGINEER (AF) SHILLONG ZONE, SHILLONG. Name of Work: PROVISION OF DEFICIENT INFRASTRUCTURE FOR INDUCTION OF MAFI AND ATS BUILDING AT AF STN PURNEA Contract No: CE(AF)SZ/PUR/ OF 2025-2026 File No: 88889/PUR/E8 Bidder Name : PRICE SCHEDULE : BOQ(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SL No ITEM DESCRIPTION Item Code / Make QTY UNIT ESTIAMTED RATE Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE IN FIGURES TO BE ENTERED BY THE BIDDER RS. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT IN WORDS Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | SCHEDULE \\"A\\" Part - I (A)(BUILDINGS/STRUCTURES WORK)Details of Buildings are given here-in-before:- |
| 3 | SCHEDULE \\"A\\" Part - I (B)(ADDN/ALTN OF EXISTING ATC BUILDING WORK)Details of Buildings are given here-in-before:- |
| 4 | SCHEDULE \\"A\\" PART- II ( SITE CLEARENCE, SITE DEVELOPMENT AND EARTH WORK) Details of prepriced Schedule is given in tender documents |
| 5 | SCHEDULE \\"A\\" PART- III( INTERNAL ELECTRIFICATION)Details of prepriced Schedule is given in tender documents. |
| 6 | SCHEDULE \\"A\\" PART-IV ( INTERNAL WATER SUPPLY )Details of prepriced Schedule is given in tender documents. |
| 7 | SCHEDULE \\"A\\" PART- V (ROAD/PATH&CULVERT)(RIGID PAVEMENTS)Details of prepriced Schedule is given in tender documents. |
| 8 | SCHEDULE \\"A\\" PART- VI (SEWAGE DISPOSAL)Details of prepriced Schedule is given in tender documents |
| 9 | SCHEDULE \\"A\\" PART- VII(EXTERNAL WATER SUPPLY)Details of prepriced Schedule is given in tender documents |
| 10 | SCHEDULE \\"A\\" PART- VIII(EXTERNAL ELECTRIC SUPPLY)Details of prepriced Schedule is given in tender documents. |
| 11 | SCHEDULE \\"A\\" PART- IX (FIRE FIGHTING AND FIRE ALARM)Details of prepriced Schedule is given in tender documents |
| 12 | SCHEDULE \\"A\\" PART -XII (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under Col.' F ' signifies this fact only. |
| 13 | INTERNAL ELECTRIC SUPPLYS&F LED lamp 10 Watt complete all as specified and as directed.. |
| 14 | Supply & fixing Unplasticised PVC casing caping of size 38 mm X 16 mm double lock type heavy duty standard conforming to ASTM D638, working temp 60-65 °C, Flammibility UL 94V-0 and Insulatio resistance more than 100 megaohms etc complete all as specified & directed. |
| 15 | Supply & fixing Unplasticised PVC casing caping of size 25 mm X 16 mm double lock type heavy duty standard conforming to ASTM D638, working temp 60-65 °C, Flammibility UL 94V-0 and Insulatio resistance more than 100 megaohms etc complete all as specified & directed. |
| 16 | Supply & fixing PLB Pipe for AFNET OFC of 40 mm dia including accessories etc complete all as specified & directed. |
| 17 | Supply Installation, testing and commissioning of Refrigerant type Industrial Dehumidifier having moisture removal capacity not less than 60 litres/day, air flow not less than 550 m³/hr, suitable for area coverage 50–120 m², operating on 220–240 V, single phase, 50 Hz, power consumption approx. 820 W, Noise level < 60 Db complete with hermetically sealed compressor, R-410 refrigerant, washable air filter, inbuilt humidistat, auto cut-off, condensate collection tank (7 L), castor wheels, all safety protections and accessories,including positioning, connection to power supply, earthing, trial run and performance testing complete all as specified and as directed |
| 18 | EXTERNAL WATER SUPPLYSupply, installation, commissioning and testing of Indian Iron removal plant (IRP) factory assembled floor mounted, of capacity 10000 Gallon/hrs, consisting of 01 set of multi grade filter, 01 set of oxidation chamber complete, 01 set of chlorine dosing pump including dosing system and 01 set of Air Compressor for back wash suitable for treatment of raw water to limit content after treatment pipe connection, fittings, valves etc. The Iron removal Plant shall be comprising of following :-(a) Oxidation chamber vertical cylindrical type fabricated vessel of suitable size as per IS 2062 inc pipe 100 mm, butterfly valve of suitable size inc 2 no. pressure gauge sampling cocks fitted with oxidation chamber. The shell thickness will be 6 mm and dished end having 6 mm and bed plate under drain collecting system will be strainer on bed plate diameter of vessel shall be 900 mm and height of straight 750 mm. (b) Multi Grade Filter vertical type MS fabricated vessel of suitable size as per IS 2062 including pipeline 100 mm, butterfly valve of suitable size including 2 nos pressure gauge sampling cocks fitted with sand media having 950 mm media depth. The shell thickness shall be 6 mm with header and lateral collecting system having adequate size of air vent line with valve etc diameter of vessel of MGF shall be 2000 mm and height of straight-1875 mm.(c) Multi stage high pressure electric driven Air compressor with motor of Max working pressure 20 Kg/Cm2, 200 L and shell thickness not less than 4 mm including necessary connection fittings to IRP. |
| 19 | Serial Item No. 17 (Contd....)NOTE :-(i) Max working pressure of Plant 3.5 Kg/sq cm and min working pressure 2.0 Kg/sq cm including gauge 0 to 06 Kg/sqcm.(ii) All necessary pipes, flanges, fitting, valves and inter line pipe connection and price of media grade, MNO2, Charcoal deemed to be included in quoted rates.(iii)The water sample to be tested by any CSIR Lab conforming to IS 10500 : 2012 before and after installation of filter by contractor for PH, Turbidity and Iron (mg/L) for suitable range of drinking water and cost for the same deemed to be included in quoted rates.(iv) Cost of PCC foundation, RCC, excavation, returning-filling, removal etc and filter media required at site as recommended by manufacturer deemed to be included in quoted rate. |
| 20 | M&L for Trial bore holes 250 mm dia for exceeding 0 mtr but not exceeding 30 mtr in depth from ground level in any type of strata for bore well if the same is found fit otherwise to fill up the same hole as directed by Engineer-in-Charge complete including submitting the strata details both graphically recommended as well as strata results as per IS- 2800 : 2000. |
| 21 | M&L for Trial bore holes 250 mm dia for exceeding 30 mtr but not exceeding 60 mtr in depth from ground level in any type of strata for bore well if the same is found fit otherwise to fill up the same hole as directed by Engineer-in-Charge complete including submitting the strata details both graphically recommended as well as strata results as per IS- 2800 : 2000. |
| 22 | M&L for Trial bore holes 250 mm dia for exceeding 60 mtr but not exceeding 100 mtr in depth from ground level in any type of strata for bore well if the same is found fit otherwise to fill up the same hole as directed by Engineer-in-Charge complete including submitting the strata details both graphically recommended as well as strata results as per IS- 2800 : 2000. Note :- Boring to any depth beyond 130mtr if required at site shall be carried out with prior approval of Accepting Officer and shall be paid under this item. |
| 23 | M&L for Widening of trial bore by drilling with direct / reverse rotary system upto 500 mm dia bore at any depth including all works pertaining to boring complete in all respects and all specified in alluvium spoil/soft strata incl hard stone/boulder etc. upto 80 mtr depth from ground level. Note :- Reaming/widening of trial bore to any depth beyond 80 mtr if required at site shall be carried out with prior approval of Accepting Officer and shall be paid under this Item. |
| 24 | M&L for Electro logging by means of electric logger of the complete tube well of 500 mm bore and submission of report along with its interpretation indicating exact location of filters alongwith complete casing assembly chart in the bore hole etc complete all as specified & directed. |
| 25 | M&L for Reducer socket, 250mm x 200mm (internally), fabricated from MS ERW casing pipe of 250mm bore by arc welding including necessary anti rusting black bituminous painting etc complete all as specified and directed. |
| 26 | Supplying, assembling, including jointing, lowering and fixing in position 200 mm bore (Nominal size), 7mm thick Low Carbon Galvanised Steel (LCG) strainer with continuous slot screen (V-Wire Strainer) of 1.00 mm slot width to give an open area of 30% complete all as per IS-8110 : 2000 assembled and lowered as per electro logging result and location approved by the GE including cutting welding as required etc complete all as specified and as directed. |
| 27 | Supply & fixing bail plug made out of 200mm bore ERW MS casing pipe of 8mm wall thickness, 3.0m long including 20mm dia, 50cm long D-block welded at the bottom etc complete all as specified and as directed by Engr-in-Charge. |
| 28 | Supply, fixing and lowering into bore holes centering guides suitable for 250 mm bore housing/ casing pipe etc complete all as directed by Engr-in-Charge. |
| 29 | Supply and packing with Pea gravel of 2 mm to 3.5 mm size approved quality as ordered to packed around the casing/slotted pipe in bore well etc complete all as specified and directed. |
| 30 | S&F holding clamp fabricated from mild steel plate of 10mm thick of size 115cm x 20cm in two halves having four Nos (two at each end) 24mm x 150mm GI bolts, nuts, washers suitable for clamping and holding 250mm bore casing pipe duly painted with two coats of black bituminous paint and grouted in PCC (1:2:4), type B 1, using 20 mm graded stone aggregate in block etc complete all as specified and directed by Engr-in-Charge. |
| 31 | Development of tube well by compressed air with compressor of minimum capacity of 1100/350 CFM/PSI. etc complete all as directed by Engr-in-Charge. |
| 32 | Development of tube well by means of submersible pump (of capacity not less than 25% of rated pump capacity) as required to make the well sand free upto 20 PPM in 20 min etc complete all as specified and as directed by Engr-in-Charge. |
| 33 | Yield testing of bore well by continuous pumping for 16 hrs to determine the safe pumping yield by V-notch. etc complete all as specified and directed by Engr-in-Charge. |
| 34 | S&F of well cap suitable for fixing on top of 250 mm dia casing pipe made out of 6mm thick mild steel plate with locking arrangement including spot welding with casing pipe having opening for column pipe of 100mm bore and submersible cable including necessary painting with two coat of black bituminous paints etc complete all as specified and as directed by Engr-in-Charge. |
| 35 | M&L for strata sample box of second class hard wood of size 40 cm X 30 cm X 20 cm etc complete all as directed by Engineer-in-Charge. |
| 36 | Supply and fix GI column pipe medium grade, IS-1239 marked, 80 mm bore x 3 mtr long, both end flanged joints duly screwed and welded with pipe suspended in deep bore well with groove/cut for submersible cable screwed and welded on both ends including provn of 3mm thick rubber gasket packing and GI nut bolt with washers. etc complete all as specified and as directed. |
| 37 | Testing of water for chemical, bacteriological and potability test form Govt/NABL Lab and submission of testing report. etc complete all as directed by Engineer-in-Charge. |
| 38 | M&L for pulling out and lowering in of submersible pump set from bore well made of 2 Nos RCC pillars of size 45cm x 45cm, 5m height from GL and MS Channel of approx 2.5m length of size suitable to carry load of approx 3 Ton including provision of MS flexible rope and pulley etc complete all as specified and as directed by Engr-in-Charge. |
| 39 | S&F submersible pump electric driven 415 V, TP suitable for 200/250 mm dia bore well (casing pipe size 200/250mm) and installed complete of capacity 7.5 HP Head 50 mtr including of 40 mtr long submersible cable and starter etc complete all as specified and directed. |
| 40 | Construction of brick masonry valve pit of size 90 cm x 90 cm x 90 cm (internal dimensions) with one brick thick wall in cement mortar (1:4) on 100 mm thick PCC (1:4:8), type D2, (using 40mm graded broken stone aggregate ) as in foundation lean concrete, including PCC (1:3:6), type C-1, (using 20 mm graded crushed stone aggregate) as in bedding and coping and 10mm thick cement plaster in CM (1:4) internally and externally up to 15cm below ground level and providing 25 x 25 x 6 mm angle iron frame all around the fixed point by means of 4 Nos holdfast 150 mm long made out of flat iron 40x6mm embedded in PCC block (1:2:4), type B-,1 (using 20 mm graded crushed stoned aggregate) of size 250 x 200 x 150 mm including provision of hinges welded with angle iron frame and MS sheet cover 3mm thick, MS handle of suitable size welded with MS cover and suitable locking arrangement including 65 mm dia Godrej pad lock and applying two coats of synthetic enamel paint over a coats of red oxide primer including necessary excavation and earth work in soft/ loose soil etc complete all as specified and as directed. |
| 41 | Supply and fix CI Foot Valve conforming to IS 4038, 63 mm dia. etc complete all as specified and as directed. |
| 42 | Supply and Install Pumping sets, centrifugal, electric driven, capacity of 2 HP, 300 LPM inclusive of starter and PCC foundation etc complete all as specified and as directed. |
| 43 | Supply, commissioning and testing cubical housing cabinet type, weather proof, outdoor type CPRI approved, factory made LT Panel boad, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame, suitable dimension to operate submersible pump, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 55 protection, installed on concrete base made of PCC (1:3:6), type C1, using 20mm graded aggregate,including self locking arragement and dismantling of old panel board. New Panel board shall comprise of :-(a) Indication lamp for RYB - 01 Set(b) MCCB-80 Amp, 4 pole, 25 KA fixed thermal and magnetic settig, 415 V, 50 Hz AC-01 No (incoming) (c) MCCB-40 Amp, 4 pole, 25 KA fixed thermal and magnetic settig, 415 V, 50 Hz AC-02 No (Outgoing for pump + 01 spare )(d) MCB-32 Amp, 4 pole, 25 KA 415 V, 50 Hz AC-02 No (Outgoing for 01 Pump house bldg, compressor 5 HP & 01 for bldg security light + 01 spare) (e) Supply and fix time switches 415 V three Phase of 20 Amp rating with contactor fitted inside steel enclosure - 01 No(f) S&F digital ampere meter 3 1/2 display incl CT having CTR 80/5-01 Nos & digital voltmeter 0-500 V (h) Spare space for accomodating Starter for submersible Pump,centrifugal pump and compressor |
| 44 | EXTERNAL ELECTRIC SUPPLYSupply, Installation, Testing and Commissioning of 100 KVA Isolation transformer, 3-Phase, Oil-cooled, copper-wound including first filling of oil of requisite dielectric strength as per IS : 335, unbalance type, Primary -415 V, 3 -wire, 50Hz Delta, Secondary 415 V, 4-wire to be connected in star arrangement, designed for input voltage of 415 Volt, output voltage 415 volt, input frequency 50 Hz+-3%, dielectric strength 2.5 KV for 60 seconds. Insulation to be more than 1000 Mega Ohms, Impedence Voltage - 3-4% and comprises with the followings :-(a) Standard fitting and fixtures with provision for over load short circuit, light low cut off, single phase sequence change.(b) Surge protection against load surges, insulation class 'A' digital instrumentations (digital ampere meter and voltmeter), thermometer, bottom oil cum drain valve, rating diagram and terminal marking plate, earthing terminal - 02 Nos, lifting eye / plugs, under carriage with 04 x Nos of bi-directional rollers, separate neutral bushNote(i) Pre-dispatch inspection at OEM/factory premise shall be carried out by Ref of Accepting Officer. (ii) Prior to manufacture, the contractor shall get the GA drg approved from Accepting Officer. (iii) After installation of transformer at site, the pre-commissioning test shall be carried out by SEI/EI. |
| 45 | Supply, Installation, Testing and Commissioning of 75 KVA Isolation transformer, 3-Phase, Oil -cooled, copper-wound including first filling of oil of requisite dielectric strength as per IS : 335, unbalance type, Primary -415 V, 3 -wire, 50Hz Delta, Secondary 415 V, 4-wire to be connected in star arrangement, designed for input voltage of 415 Volt, output voltage 415 volt, input frequency 50 Hz+-3%, dielectric strength 2.5 KV for 60 seconds. Insulation to be more than 1000 Mega Ohms, Impedence Voltage - 3-4% and comprises with the followings :-(a) Standard fitting and fixtures with provision for over load short circuit, light low cut off, single phase sequence change.(b) Surge protection against load surges, insulation class 'A' digital instrumentations (digital ampere meter and voltmeter), thermometer, bottom oil cum drain valve, rating diagram and terminal marking plate, earthing terminal - 02 Nos, lifting eye / plugs, under carriage with 04 x Nos of bi-directional rollers, separate neutral bushNote(i) Pre-dispatch inspection at OEM/factory premise shall be carried out by Ref of Accepting Officer. (ii) Prior to manufacture, the contractor shall get the GA drg approved from Accepting Officer. (iii) After installation of transformer at site, the pre-commissioning test shall be carried out by SEI/EI. |
| 46 | Design, Fabrication, Testing & Commissioning of Varmin dust proof LT Feerder Pillar board outdoor type of Al Bus bar 400 Amp rating made out of MS sheet 3.15 mm thick, Type tested conforming to IEC 61439, powder coated , rear and front operated door with locking arrangement , suitable aluminium busbar and fixed on angle iron base suitable for pedastal mounting of size 50x50x5 mm at least 2 feet above GL to accomodating the following (Panel for ATC Non-critical supply & Fire fighting) :- INCOMING :- (a) ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) of capacity 800 Amps - 01(in coming)OUTGOING :-(b) MCCB 3 Pole, 415 V, with Microprocessor release 630 Amps with breaking capacity 36 KA - 02 Nos (out going 01 for ATC Bldg. + 1 Spare)(c) MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA - 01 No. (outgoing fot Fire fighting pumps)(d) MCCB 3 Pole, 415 V, fixed type, 25 Amps with breaking capacity 16 KA (e)Digital Multi-functional Meters for measuring current, voltage and frequency including CTs of suitable rating and class Note : The rate also inclusive of all material mentioned from sl no (a) to (e) and PCC foundation etc complete. |
| 47 | M&L for boring of holes under road, pavement, hard standing mannually or by trenchless technology using ultra sounding technique and necessary machine or mannually etc as per site requirment etc complete all as specified and directed. |
| 48 | S&F polymer based dropout fuse unit complete set suitable and including for 11 KV, HT outdoor and dropout type of capacity 200 Amps including jumper connections with copper flexible designed jumper and testing and commissioning etc complete all as specified and all as per the directions of Engineer-in-charge . |
| 49 | M&L for cable junction box with IP 66 protection (halogen free and weather proof) for outdoor installations of size 155 x 210 x 92 mm with terminals including SP MCB of 6 A, gland for cable, FI clamp of size 20x3 mm, nuts, bolts, washers, including provision of connectors for connection of cables etc complete all as specified and directed . |
| 50 | Supply & fix 2 way NO/NC contract start & stop push button switch (red & green) along with box enclosure fitted on wal etc complete all as specified and directed . |
| 51 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded COPPER conductor of size 6.0 sq mm 3 core. (APLB) etc complete all as specified and directed . |
| 52 | M&L for taking down cables/busbar from transformer/LT side and making necessary arrangment/fabrication in existing HVDB to facilitate connection of Voltage stablizer and isolation transformer to transformer and LT switchgear side of existing HVDB etc complete as directed by Eng- in- Charge. |
| 53 | Supply & Installation of Advance encapsulated compound based CPRI tested maintenance free, pipe in-pipe technology upgraded (Zinc & Alloy Coated), ZINC COATED (80-100) microns with pure Zinc(99.9%) & ALLOY COATING (200-250)microns. Earthing System confirming IS 3034.The outer and inner pipe should be 48.3mm & 26.4mm 3 mtr Length, Zinc coated with additional special Alloy coating 300mm on the topside for additional protection of the Terminal. The annular space between the pipes being filled up with COMPACT FILL (CF) (Crystalline Conductive Compound). The COMPACT FILL (CF) mixture which is machine pressed in the pipes should not disintegrate or collapse when outer pipe corrodes. The inner pipe should be extended with terminals for connectivity, The job includes digging the pits and refilling the same by Electrodite & Conductolite Back Fill compound (Ground Enhancer), the BFC should be eco friendly it should not contain environmentally hazardous material/metal having ROHS Certification from NABL accredited lab. The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals. the earth pit has been excavated 1mx1mx3m and filled with, G00D EARTH ie Black cotton or moistures normal soil is to be arranged to fill the excavated pits by mixing the arranged soil with BFC 2 Electrodite & 2 bags Conductolite BFC for installation of earth Electrode. Note: Earth strip for connection will be measured and paid seprately.The earthing value should be less than 2 Ohms for single earth. |
| 54 | Supply and fix Baron back fill compound (CONDUCTOLITE) 25KG a bag for filling in exixting earthing etc complete all as specified and as directed |
| 55 | Supply and Fix in replacment test point terminal block made of gun metal or phosphorous bronze, size 75 X 75 X 25 mm , drilled and screwed including 3 Nos. 8 mm dia. 25 mm long hexagonal head screws in repair including MS box 2 mm thick of suitable size for protection of test point terminal & including taking down Old rusted test point etc complete all as specified and directed. |
| 56 | AIR CONDITIONERSupply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR etc complete all as specified and directed. |
| 57 | Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 4 star rating and EER 3.2.of capacity 2 TR etc complete all as specified and directed . |
| 58 | Supply and install Cassette type units indoor/outdoor complete with cordlessremote control unit, twin rotary compressor, single phase units 220V-240V, 50 Hz of capacity 3 TR complete all as specified and directed . |
| 59 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA etc complete all as specified and directed . |
| 60 | FIRE FIGHTING AND FIRE ALARMFire Alarm Detection SystemM&L for Control console, complete all as specified and directed. |
| 61 | Supply and fixing XLPE insulated heavy duty FRLS copper armoured conductor 1.5 Sqmm 2 Core, working voltage 1100 volts conforming to IS: 1554 part - for Fire Alarm System including earth work wherever required etc complete all as specified and as directed. |
| 62 | S&F auto-illuminated (glow-in-dark) exit sign board with green colour background with appropriate symbol, made up of acrylic sheet for fire escape in minimum 10 cm x 30 cm size to be pasted on wall with high quality adhesive or to be hanged with s.s. hook-chain system etc complete all as specified and as directed. |
| 63 | First Aid Fire ExtinguishersSupply only of stored pressure fire extinguiser ISI marked 6 KG Clean Agent Fire Extinguisherof fire rating 2A : 55B Fire consisting with discharge hose and nozzle of welded cylinder, squeeze lever discharge valve fitted with pressure indicating guage, internal discharge tube, discharge nozzle suspension bracket conforming to IS : 15683 :2006 (old IS : 2878) duly charged with ISI Marked Mono Ammoniumphosphate base ABC powder conforming to IS : 14609 and pressurized with Nitrogen Gas, suitable for operating between 30 degree centrigrade to + 55 degree centigrate, Fire Rating Class - 1A & 13B etc complete all as specified and as directed. |
| 64 | Supply only of fire extinguiser ISI markedLight weight squeeze grip type CO2 type Fire Extinguisher 3 KG capacity conforming to IS : 15683 :2006 (old IS : 2878) made from seamless cylinder conforming to IS : 7285 duly approved by chief controller of explosive , Nagpur fitted with ISI Marked Controlled valve conforming to IS : 3224 , high pressure 1 mtr long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket, , suitable for operating between 30 degree centrigrade to + 55 degree centigrate, Fire Rating Class - 13B etc complete all as specified and as directed. |
| 65 | Supply and fixing Ceiling Mounted Clean Agent ( HFC236fa) Fire Suppression System 5 KG Capacity, Modular type , Fire Class A,B,C & Electric with automatic discharge mechanism, discharge time - Min 8 Sec all as specified. |
| 66 | Fixed fire fighting systemSupply & Fixing foot valve conforming to IS 4038, 150 mm (6”) dia etc complete all as specified and as directed. |
| 67 | Supply & Fixing foot valve conforming to IS 4038, 80 mm dia etc complete all as specified and as directed. |
| 68 | Supplying and fixing Draw off connection as per Fire Service design complete with CI DF Foot valve with nuts & bolts and high pressure rubber gasket, suitable for 100 mm dia MS pipe connection etc. complete as required 6 KG Clean Agent Fire Extinguisher. |
| 69 | Supply, install, testing and commissioning of wall mounted indoor cubical type LT Control Board, factory fabricated CPRI type tested with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-43 & general construction confirming to IS-13947, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming MCCB rating. The panel board shall be fabricated out of 2.0 mm thick CRCA sheet duly pre-treated & powder coated, suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes complete all as specified & as directed with & incl the following accessories :- (For Terrace Pump)BUS-BAR & INTERNAL CONNECTIONS :The bus-bars shall be made up of 04 Nos Aluminium bar 100 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized \\"F\\" class insulators of non-hygroscopic, non-combustible, all internal connections form main bus-bars to switch gears etc.PROVISION FOR CABLE ENTRY :The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables.INCOMING (a) MCCB 4P (Ics = 100% Icu) with adjustable thermal magnetic release, having breaking capaity 16 KA of rating 32 A - 01 No. OUTGOING/INSTRUMENTATION SYSTEM :(a) MCCB, 3 Pole, 25 Amp rating, (Ics = 100% Icu) with adjustable thermal magnetic release, having breaking capaity 16 KA - 02 Nos. (01 No Spare) |
| 70 | Serial Item No. 68 (Contd....)(b) Fully Automatic Panel mounted open execution star-delta starter suitable for 15 HP induction motor for Terrace Pump, 415 volts, including overload relay, auto timer & single phase preventer etc complete -02 Nos (01 No Spare)(c) Auto Control System for Start/Stop of Terrace Pump controlled through pressure switch (paid separately) and other switching control from Fire Control Panel with necessary PLC system with microproceesor controlled relay etc - 02 Sets (d) Digital multi functional meter to indicate voltage, ampere and frequency - 1 No.(g) Indicator lamp with LED (red, yellow & blue), Set of Three - 01 Set(h) Auxiliary Switch with indicator for testing the Pumps on manual mode - 01 NoNOTE : (i) Design / drawing of the Panel Board showing the dimensions shall be obtained from Manufacturer / Supplier & shall be got approved from the Dept before placing final order to the manufacturer.(ii) Anyt items not ementioned above in the technical specifications but technically required for efficient working is deemed to be included in the above quoted rates. |
| 71 | Supplying, installation, testing and commissioning of Repeater Panel showing fire alarm status centrally details as below.a). GSM model with Input output b). Power supply 24 volt c). Battery backupd). Programmable logic controller (PLC) for Intelligent remote terminal unit (iRTU)e). Panel size 600mm x 400mm x 250mm Note : The above work includes charges for Up gradation of RTU Panel software and new sim card installation & SMS Rental Charges for 1 Year. |
| 72 | S&F Direct Low Pressure Clean (DLP) agent fire suppression system: AR SUPPRESSION utilizing various Low-pressure Clean agents i.e. HFC227ea, Novec1230/FK-5-1-12. including The AR SUPPRESSION Linear Pneumatic Fire Detection Tubing (LP-FDT) complete all as specified and directed |
| 73 | Design, supply , installation, testing and commsissioning of clean agent based fire suppression flooding system for server cabinates operated through linear pneumatic tubing auto detection system and interlinked with control panel of the proposed fire detection system etc complete all specified & directed. |
| 74 | DG SET FOR ATC BldgSupply and installation of silent Diesel Engine driven generating set of capacity 500 KVA 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB (CENTRAL POLLUTION CONTROL BOARD) norms and foundation etc, in addition to the details as listed below complete all as specified and as directed :-A.a) Fly wheel to suit flexible coupling.b) Flexile coupling with guards.c) Dry type air cleaners with filters.d) Lubricating oil filter, fuel filter, fuel pre filter.e) Anti-vibration pads-quantity and type as recommended by manufacturer.f) Fuel injection system with injector pump, nozzles, governor(electronic) of suitable capacity.g) Electric start equipment.h) Lead acid storage maintenance free battery 2x12V DC of suitable rating with charging alternator, ammeter, as recommended by manufacturers make: As per OEM standard along with copper battery lead and connector.i) Battery rack made out of MS angle iron 40mmX40mmX5mm and 150mm height.j) Standard safety device. k) Daily service fuel tank of suitable capacity for running 12 hrs non-stop on Full Load with mechanical level indicator, detachable strainer, drain cock, fuel outlet, air vent and locking arrangement etc, including fuel pipe connections. |
| 75 | Serial Item No. 73 (Contd....)l) Exhaust silencer(Residential silencer) with exhaust piping of suitable size brought out side on top of size 76.5 mm dia and complete length of silencer and exhaust piping continuously wrapped with 12 mm dia asbestos rope and suitable anti vibration arrangement around pipe passing through wall. m) LCD display type control panel as per manufacturer's instructions indicating KWH, KVA, PF, Volts, Amps, Hz, RPM, Hour, Oil pressure, Oil temprature, coolent temprature, fuel level, battery charging ammeter, battery charging lamp and incator lamp (RYB), panel duly prewired and displaying protection and safetys as under:- aa) Protection:- short circuit, overload, over speed, earth fault as standard and reverse power as optional.ab) Safeties:- Auto shut down, visual & audio alarm for low lub oil pressure, high coolant temperature, low fuel level, canopy temperature & radiator water level.(B) Alternator 500 KVA brushless type at 0.8 power factor, self regulated, self excited, screen protected 3 phase with neutral 415 volts 50 HZ, 1500 RPM, as per IS:13364/IS-4722 complete with automatic voltage regulator, having voltage regulation +/-1%, SPDP enclosure including making cable connections, insulation class-H and alternator control panel as supplied by manufacturer.C) Base frame sturdy, MS fabricated, channel iron base frame for mounting the engine & alternator with anti vibration pads. |
| 76 | Serial Item No. 73 (Contd....)(D) Acoustics enclosure of suitable size to accommodate DG set 500 KVA, modular construction, fabricated out of 3 mm thick, cold annealed CRCA sheet duly epoxy painted doors to be provided with high quality EDPN gasket, duly epoxy painted. The canopy to be equipped with heavy duty fans of reputed manufacturer for air circulation and cooling the canopy. Rock wool of requisite density per Kg/m3 to be used for insulation. Enclosure to be provided with one light point controlled with one switch for internal lighting. Noise level at one meter to be 75 decibels @ one meter in line as per CPCB norms.(E) Repair tools to be supplied as under:-(i) Ring spanner set of 10- 01 set. (ii) Screw driver 6\\",9\\", 12\\", 14\\" - 01 No Each.(iii) Adjustable spanner 12\\" - 01 No. (iv) Double end spanner set of 10 - 01 No.(v) Cutting pliers insulated and nose plier 10\\" & 12\\" - 01 No. (vi) Techo meter - 01 No.(vii) Tool kit box - 01 No. (F) Maint spares to be supplied as under :- (i) All type of filters - 02 Each. (ii) V-Belt - 01 SetNOTE:- (i) The engine of DG set suitably conditioned to suit the climatic condition, so as to give desire outputs including and testing up to 10% over load.(ii) Foundation of the DG set (PCC/RCC) will be provided by the contractor and will be made as per the manufacturer instruction. Cost of foundation is deemed to be included in the rate of this item. (iii) The items required for testing of DG set e.g. fuel, tripod, tools, water tank etc and panel as below shall be provided by the contractor and the rate of which is deemed to be included in the rate of item. (iv) Testing of DG set will be carried out as specified. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail