| 1 | M&L of Applying 10 mm thick of Finishing the brick surface with water vapour permeable mortar, UNOFIN CLASSIC basecoat Render or equivalnt for weather resistant & high performance façades with CSIV compressive strength, Flexural Strength ≥ 2.5 N/mm2 and water vapour permeability ≤μ15 as per EN 998-1. The system includes the reinforcement of weaker points/areas (change in the substrate material, slabs, pillars, roller blind boxes, around the openings/windows, doors, etc.), with fibreglass mesh to avoid cracks as per manufacturer’s recommendations including taking down of plaster/scraping of wall wherever required |
| 2 | Finishing with the rainwater resistant and water vapour permeable rendering mortar, of thickness 10 mm UNOFIN PRIME COARSE Render, or equivalent applied in two coats for rainproof/weather resistant & decorative facades with a CSII Compressive Strength class, Flexural Strength ≥ 2.5 N/mm2, resistance to water absorption as W2 (C ≤ 0.2 Kg/m2.min0.5), water vapour permeability ≤μ15 as per EN 998-1. The system includes the reinforcement of weaker points/areas (change in the substrate material, slabs, pillars, roller blind boxes, around the openings/windows, doors, etc.), with fibreglass mesh to avoid cracks as per manufacturer's recommendations. |
| 3 | Excavation in trenches n.exc. 1.5m wide and n.exc 1.5 m in depth for foundation for laying /taking down sewage / water supply lines , forming bottom surfaces to required slope & gradient and n.exc 10sqm on plan and n 'exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 4 | Demolition of brick work built in cement mortar incl all quoins, arches, pillars etc complete all as specified and as directed. |
| 5 | M&L Burnt bricks work with whole kiln burnt well burnt old size bricks built in CM 1:4 in walls straight on plan/ exceeding 6 mtrs mean radius complete. |
| 6 | M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in coping exposed surfaces finished even and smooth using extra cement including necessary form work complete all as specified and directed by Engr-in-Charge. |
| 7 | Returning ,filling in including spreading levelling watering and well ramming in layers not exc 25cm thick in soil in any depth complete all as specified and directed by Engr-in-Charge |
| 8 | Removing excavated soil/ materials to a distance not exc 50 mtr and depositing where directed at a level not exceeding 1.50 m above the starting point complete all as directed by Engr-in-Charge |
| 9 | M&L for PCC (1:4:8) type D2 using 40mm graded stone aggregate as in foundation of manholes, mass concrete etc. complete all as directed by Engr-in-Charge |
| 10 | Demolition of cement concrete in ground floors and paving n exc 15cm thickness (below or above GL) |
| 11 | M&L for 75mm thick PCC type C2 1:3:6 using (40mm graded aggregate) as a leaveling course Complete all as specified and as directed. |
| 12 | Material and labour Machine pressed precast concrete rubber moulded interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed. |
| 13 | M&L sand filling under floors or in foundation including watering and consolidation |
| 14 | M&L for Factory made cement concrete prepolished rouber moulded coloured chequered tiles 300x300 x20 to 25 mm thick complete all as specified & directed. |
| 15 | Screed bed or bedding layer of mortar 20mm thick for laying floor finishes in CM 1:6 |
| 16 | Material and labour Machine pressed precast concrete rubber moulded interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade complete all as specified and directed. |
| 17 | M & L Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complet complete all as specified and directed |
| 18 | Taking down cement plaster of any description and in any position of brick or stone wall/concrete surfaces on walls, ceiling etc including raking out joints ,hacking for key scrubbing down with water etc & prepared to receive new plaster complete all as specified and directed |
| 19 | M&L rendering 15 mm thick in CM 1:4 on brick/concrete wall surfaces of any description, and finishing the surfaces even and fair without using extra cement complete all as specified and directed. (Plaster will be carry out in two layers first layer is of 10mm and second layer is of 5mm) |
| 20 | M&L for preparation of newly plastered surfaces of walls & applying 2 coat of cement base paint over a coat of alkali resistant primer complete all as specified and directed. |
| 21 | Material & Labour preparation of newly plastered surfaces of walls & applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. Complete all as specified and as directed. |
| 22 | M&L preparation of old decorated surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efforescent salts and trading oil and greasy spots etc and applying one coat of cement base paint on decorated plastered surfaces of walls. ( Note :- All holes/cracks to be filled with birla putty and making good to old surface) |
| 23 | M&L for preparation of old decoreated/undecoreated external wall / Ceiling applying two coats of weather proofing exterior acrylic emulsion paint by spray gun/ spray machine up to 5 storey bldg complete all as specified and all as directed by Engr- in-charge.Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes.2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Notes for item Nos 23: (a) The work shall be executed through authorised applicator of manufacturer only.(b) Authrised Applicator shall be approved by GE before starting of work.(c) All materials shall be procured directly form manufacturer. The purchase voucher shall be produced to the Engineer-in-Charge for his verification of material.Engineer-in-Charge shall deface the original purchase vouchers.(d) MOU with authorized applicator will be submitted by contractor within 7 days after opening of Financial Bid.(d) A guarantee amount of 5% of contract of work done for item Nos 23 of BOQ will be retained for 5 years of the completion of work.Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. |
| 24 | Dismantling of RCC jali or stone jali and removed from MOD land all as specified and dierected by Engr-in-Charge. |
| 25 | S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as directed. |
| 26 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed |
| 27 | S & F in repair Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified |
| 28 | S&F in repairs pre painted galvalume aluminum ZINC coating GI base corrugated steel 0.5mm thick of any colour having tensile strength of 550 MPA as in roof covering/cladding to wall fixed with self tapping screw with minimum 150mm end lap and one corrugation side lap including dismantling the existing any type of sheets complete all as specified and directed. |
| 29 | S & F in repair 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified. |
| 30 | M&L preparation of new steel and iron surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of redoxide primer, complete all as specified. |
| 31 | Dismantling post or struts (wood , steel or RCC) of any section any description and in any position including taking out embedded portion in concrete, brick work, masonry etc and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed |
| 32 | Dismantling chain link fencing of any type fixed in any situation including flat iron MS round bars, mounted on nuts & bolts etc complete all as specified. |
| 33 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire |
| 34 | Supply only Chain link MS galvanisd fencing, any size or type |
| 35 | M&L for mild steel works as in angle iron posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including al necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 36 | Supply of Fe 410-W Gde -E- 250 quality (A) Mild steel in flat, round or square bars, in available lengths. |
| 37 | S&F Mild steel screw sbolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed ene to be fitted with washers and one hexagonal or square nut, exc 5cm long but n.exc 10cm long and dia of neck 11mm to 15mm complete all as specified and directed. |
| 38 | M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 39 | M & L for providing precast reinforced cement concrete jallies 40 mm thick including all mouldings type B-0 1:2:4 (12.5mm graded stone aggreagte) set in cement mortar 1:4, complete all as specified. |
| 40 | Schedule of Credit Please Enable Macros to View BoQ information |