| 1 | M&L for 5 mm thick acrylic sheet of size 200mm x 300mm fixed on wall over suitavle fastener border over the stone ofr building insignia (letter size ht 100mm and 50 mm width) for numbering qtrs, Garrages complete all as specified and directed. |
| 2 | Demolition of brick work built in cement mortar incl all quoins, arches, pillars etc complete all as specified and as directed. |
| 3 | M&L Burnt bricks work with whole kiln burnt well burnt old size bricks built in CM 1:4 in walls straight on plan/ exceeding 6 mtrs mean radius complete. |
| 4 | M&L for followings :-(i) Removing plaster & finishes from all exposed / damaged portion of coloumns, slabs & beams(ii) After cleaning gently removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete shall be done to an extent when reinforcement is visible from all sides)(iii) Removal of cover concrete with under cutting of up to a depth of 10mm beyond reinforcement around full circumference & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed)(iv) Cleaning exposed concrete substrate by using water jet.(v) Removing visible rust along the length of reinforcement using hand tools as approved.(The Engr-in-charge may order sand blasting if needed)(vi) Any other work as directed by Engr-in-charge to present clean surface for determination of type of repair to be carried out complete all as specified and directed. Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. |
| 5 | M&L for providing rust proof /anti corrosive treatment to bars :-(i) cleaning of all exposed bars (new & old) alround(ii) Apply a single coat of Alkaline rust converting primer on alround bars new & old as recommended by the manufactuer(iii) Apply two coats of Epoxy phenolic anti corrosive protective coat on bars alround new & old as recommended by the manufactuer. Note : Anti corrosive treatment shall be continuous espcially in the regions where pitting, imperfections, etc were present on the surface of the bars. It is important that the rear portions of re-bars (those towards the concrete substrate) should not be left without coating .Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. |
| 6 | M&L for providing PMM (Polymer modified cementitious mortar) :-(i) Dry sub strate surface and free of debris & dust(ii) Applying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible.(In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes).(iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitious mortar) upto 50 mm thickness.Note : Application of PMM shall be preferably be in coats of appx 10mm thickness. PMM work shall be executed in fairely rapid successions so as entire work is completed with in 30 mins). PMM shall be pre packed ready to use.(iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufactuer complete all as specified and directed. Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. |
| 7 | S&F in repair of Upvc pipe line (Sch-40) of 32 mm dia for AC drain fixed to wall with suitable fittings like elbo, tee etc and clamping with wall all as specified and directed by Engr-in-Charge.Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. |
| 8 | S&F in repair 150 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed complete to walls, ceilings or in floors with suitable clamps/bracket including taking down old PVC/CI pipes and necessary cutting through RCC roof and brick work etc (above six storey height) and making good all as specified. |
| 9 | S&F in repair of 150mm dia PVC (SWR) TEE any radius with solvent joints, complete all as specified. |
| 10 | M&L of Applying Finishing the brick surface with water vapour permeable mortar, UNOFIN CLASSIC basecoat Render for weather resistant&equivalent & high performance façades with CSIV compressive strength, Flexural Strength ≥ 2.5 N/mm2 and water vapour permeability ≤μ15 as per EN 998-1. The system includes the reinforcement of weaker points/areas (change in the substrate material, slabs,pillars, roller blind boxes, around the openings/windows, doors, etc.), with fibreglass mesh to avoid cracks as per manufacturer’s recommendations.including taking down palster or scraping if required. |
| 11 | Finishing with the rainwater resistant and water vapour permeable rendering mortar, UNOFIN PRIME COARSE Render and equivalent, applied in two coats for rainproof/weather resistant & decorative facades with a CSII Compressive Strength class, Flexural Strength ≥ 2.5 N/mm2, resistance to water absorption as W2 (C ≤ 0.2 Kg/m2.min0.5), water vapour permeability ≤μ15 as per EN 998-1. The system includes the reinforcement of weaker points/areas (change in the substrate material, slabs, pillars, roller blind boxes, around the openings/windows, doors, etc.), with fibreglass mesh to avoid cracks as per manufacturer's recommendations. |
| 12 | Dismantling of RCC jali or stone jali and removed from MOD land all as specified and dierected by Engr-in-Charge. |
| 13 | S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as directed. |
| 14 | Taking down cement plaster of any description and in any position of brick or stone wall/concrete surfaces on walls, ceiling etc including raking out joints, hacking for key scrubbing down with water etc & prepared to receive new plaster complete all as specified and directed |
| 15 | M&L rendering 15 mm thick in CM 1:4 on brick/concrete wall surfaces of any description, and finishing the surfaces even and fair without using extra cement complete all as specified and directed .(Plaster will be carry out in two layers first layer is of 10mm and second layer is of 5mm) |
| 16 | Material & Labour preparation of newly plastered surfaces of walls & applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. Complete all as specified and as directed. |
| 17 | M&L preparation of old decorated surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efforescent salts and trading oil and greasy spots etc and applying one coat of cement base paint on decorated plastered surfaces of walls. ( Note :- All holes/cracks to be filled with birla putty and making good to old surface) |
| 18 | M&L for preparation of old decoreated/undecoreated external wall / Ceiling applying two coats of weather proofing exterior acrylic emulsion paint by spray gun/ spray machine up to 5 storey bldg complete all as specified and all as directed by Engr- in-charge.Notes for item Nos 18: (a) The work shall be executed through authorised applicator of manufacturer only.(b) Authrised Applicator shall be approved by GE before starting of work.(c) All materials shall be procured directly form manufacturer. The purchase voucher shall be produced to the Engineer-in-Charge for his verification of material.Engineer-in-Charge shall deface the original purchase vouchers.(d) MOU with authorized applicator will be submitted by contractor immediately after placing of work order.(e) A guarantee amount of 5% of contract of work done for item Nos 18 of BOQ will be retained for 5 years of the completion of work. Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. |
| 19 | Non - skid Ceramic white tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not xceeding 0.38 sqm, in floors etc. set and jointed Screed bed 1:6 in neat cement slurry and pointed in white or coloured cement to match. |
| 20 | S & F in repair Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified |
| 21 | S&F in repairs pre painted galvalume aluminum ZINC coating GI base corrugated steel 0.5mm thick of any colour having tensile strength of 550 MPA as in roof covering/cladding to wall fixed with self tapping screw with minimum 150mm end lap and one corrugation side lap including dismantling the existing any type of sheets complete all as specified and directed. |
| 22 | M&L preparation of new steel and iron surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of redoxide primer, complete all as specified. |
| 23 | S&F of display board of size minimum 1 sqm of colourd acrylic sheet of minimum 8 mm thickness sheet to show houses occupants(Offrs) name, display board will show house number in 3 digit & works like Ground,1st to5th floor on board, size of word should be either 25mm*15mm or instructed by Engr-in-Charge, with fixing/detachable arrangements, this item includes dismantling/ removal of old board complete all as specified and directed. |
| 24 | Schedule of Credit Please Enable Macros to View BoQ information |