| 1 | Taking outMirzapur or glazedporcelain tiles carefully bychiselling fromwallsor floor includingstacking serviceable material as directed. |
| 2 | Stripping off worn out plaster and raking out joints of walls,celingsetc.uptoanyheightandin any floor including removing rubbish within a lead of 75m as directed. |
| 3 | Cleaningtheconcretesurfacebyremovingdirtanddebris,markingdefectivelocations and removing loose concrete by careful stripping untill hard surface is exposed, cuttingtheconcretetoregularshape,wirebrushingtheexposedsurface and removing debris fromsite complete as per direction of theEngineer - in - Charge. |
| 4 | Cleaning the exposed reinforcement preferablyupto full diameter bywire brush,applyingtwocoatsof polymer based rustremovingcompoundleft for24hours, removing thecoatingandthenapplyingtwo(2)coatsofpolymermodifiedanticorrosiveprotectivecoatingformulatedtoinhibit thecorrosionof reinforcement as per manufacturer's specification][ |
| 5 | Applyingepoxybasedreactivejoiningagent forjoining the oldconcretewithfresh concrete to be appliedwithin manufacturer's specified time as permanufacturers specification. (0.4 Kg / m² of concrete surface). |
| 6 | Cement concrete (1:1.5:3) with graded stone chips 5.6 mm size withhexagonalsquaremeshwirenetting, I.R.C. fabricmeshorX.P.M. fittedandfixedafter tyingtheexisting reinforcement onconcretewithoutdistributingthe same andwith proper scarping and cleaning thereinforcement anddisturbed concretewithwire brush etc. after applying a coat ofcementincludingthecostofwirenetting I.R.CorX.P.M.&costofallhandlingandscaffolding complete as per direction of Engineer-in -charge. |
| 7 | Plaster(towall, floor, ceilingetc. withsandandcement mortarincluding rounding off or chamfering corners as directed andraking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excludingcost of chipping over concrete surface](i) With 1:6 cement mortarb) 20 mm thick plaster |
| 8 | (ii) With 1:4 cement mortarc) 10 mm thick plaster |
| 9 | Supplyingand laying true to lineand levelDoubleChargeVitrified Tiles of approved brandconforming to IS 15622: 2006 (GroupBIa andtestedasperIS13630:2006 (relevantparts)[Non-modular sizes for tileswithWater Absorption (av.) ≤0.08%] infloor, skirtingetc. set in20mmthicksandcementmortar (1:4)bedprepared afterapplicationof slurryusing1.75Kg of cement per Sqmover the base and 2mm thick cementslurryusing [email protected]./sqmat thebacksideof the tilesand laid over themortarbedusing 0.2kg/sqmof Whitecementused for joint fillingwithapprovedpigmentasdirectedand removalofwaxcoatingof topsurfaceof tiles withwarm water andpolishing the tiles usingsoft anddrycloth upto mirror finish complete including the cost of materials, Iabour and all other incidental charges completetrue to the manufacturer's specification and direction ofEngineer-in-Charge.a)lnGroundFIoor:(sizenotIessthan600mmX600mmX9.5mm thick) |
| 10 | Supplying, fitting&fixing1st qualityCeramic tiles inwallsand floors tomatchwith theexistingwork&4nos. of keystones (10mm) fixedwitharalditeat thebackof each tile&finishing the jointswithwhite cementmixedwithcolouringoxide if required to match the colour of tiles includingrougheningof concrete surface, if necessaryorby syntheticadhesive & grout materials etc.B) Wall WithSandCementMortar (1:3) 15mmthick&2mmthickcement slurry at back side of tiles using [email protected]/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m.b) Area of each tile above 0.09 Sq.m(i) Coloured decorative |
| 11 | Supplying,fitting&fixinggraniteslab15mmto18mmthickinfloor, lobby, stair, landingand treads etc.over20mm (avg)thickbaseofcementmorter (1:2)laidwithwhite cement etcc) Area of each Granite slab above 1.00 Square meter. |
| 12 | Supplying, fittingandfixingBlackStoneslabusedinKitchenslab, alcove, wardrobe etc. laidand jointedwith necessaryadhesiveCementmortar(1:2)including grindingorpolishingas per direction of Engineer-in -Charge in Ground Floor.b) Slab Thickness above 25 mm and upto 37.5 mm |
| 13 | OrdinaryCementconcrete(mix1:2:4withgradedstonechips(6mmnominalsize) excluding shutteringand reinforcement,if any, ingound floor asperrelevant IS codes.Pakur variety |
| 14 | Supplying profiles of required section made of Aluminium AlloyExtrusionsconforming toIS:732-1983 andIS:1285-1975;Annodized(withrequiredfilmthickness andspecifiedcolour/natural)mattfinishedconformingto IS:1868-1983forfabricationofcompositdoor, sliding&casement windows, partitions, formed of basic sections of any ISIembossed/certifiedmakeandbrand asperdirectionofEngineer-InCharge.(A) In 10-12 Micron thickness Annodizing filmII) Colouredi) Fixed partitions.i) Top , bottom & side member. |
| 15 | ii) Intermediate member. |
| 16 | iii) Glazing clip. |
| 17 | k) Movable door shutter.i) Door frame. (Top & sides). |
| 18 | ii) Shutter :Top rail. |
| 19 | Bottom rail. |
| 20 | Lock rail |
| 21 | Door vertical. |
| 22 | Labour charge for fabrication and installation of composite door,window, partitions made fromannodized extruded alloy aluminiumsections for the following units:A)Glazedaluminiumslidingwindowsmadeofextrudedandannodizedalloyaluminiumsectios, fabrications, including cuttingtopropershapeandsize,drillingandaligningofwindowshutterframefittedwithinbuiltlockingarrangements,slidingrollersandothernecessaryfittings,fixture,adhesives and joineries along with extruded neoprine or EPDMgasketing inbetweenwindowframeandmasonrywork (walls,column,beam.lintelsetc.aswellasbetweenglassandshutter frame for fixing glassand Polysulphides ealantandin betweenshutterandwindowframewherenecessary includingcutting torequisitesizeand fixingglassasper drawing, specification and direction of EIC. Therate includes thehirechargeof all toolsandplants, includingallincidentalcharges,adhesive, joineries such asscrew,cleatangleetc.butexcluding the cost of extruded aluminiumsections, glass, neoprene /EPDM gasket, locking arrangement and rollers.iv ) Fixed glazing. |
| 23 | Supplying bubble free float glass of approved make and brandconforming to IS: 2835-1987.iv) 5mm thick coloured / tinted / smoke glass. |
| 24 | Supplyingfitting&fixinginposition9mmthickHeavyDutyCementboard-TypeA(HighPressure steamcured, testedas perAS-1530part 3&BS-476Part4,5,6,7&8,density> 1450kg/m3,Bondstrength15N/sqmmfireresistant,termiteproof,moisture resistant) reinforcedwithcellulose fibre manufactured through autoclavingprocess asper IS:14862&ISO8336,withfibrecement screws inpartition excludingcostofsupportingstructureasperdrawingsanddirectionofEngineer-in-Chargecomplete. |
| 25 | Anodisedaluminiumbutthingesofapprovedqualitymanufacturedfromextruded sectionconforming to I.S. specification (I.S. 205/66) and fittedand fixedwithcadmium plated screws:(v) 100 x 63 x 3.2mm. |
| 26 | Anodised aliminiumD-type handle of approved quality manufactured fromextruded sectionconforming to I.S. specification (I.S. 230/72) fittedand fixedcomplete:(a) With continuous plate base (Hexagonal/ Round rod)(iii) 100 mm grip x 12 mm dia rod. |
| 27 | Anodised aluminiumbarrel / tower / socket bolt (full covered) of approved manufactured fromextruded sectionconforming to I.S. 204/74 fittedand fixedwith cadmium plated screws:v) 150mm long x 12mm dia. bolt. |
| 28 | HydraulicdoorcloserofapprovedqualityasperI.S.I.standardfittedandfixed complete.(a) Heavy type (I.S.I. size 3) |
| 29 | ii) Door stopper (Anodised aluminium) |
| 30 | (a)Cleaning the walls and ceiling by scraping, sand papering and smoothening down the surface including putting. |
| 31 | Rendering theSurfaceofwalls andceilingwithWhite Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) |
| 32 | ApplyingInteriorgradeAcrylicPrimerofapprovedqualityandbrandon plastered or cencrete surface old or new surface to receiveDistemper/Acrylicemulsionpaint including scrapingandpreparing thesurfacethroughly, completeaspermanufacturer'sspecificationandas per direction of the EIC. (In Ground Floor)(a) One Coati) Water based interior grade Acrylic Primer |
| 33 | ApplyingAcrylicEmulsionPaint of approvedmakeand brandonwallsandceilingincludingsandpaperinginintermediatecoatsincludingputty(to be done under specific instruction of Superintending Engineer) : (Two coats) i) Standard Quality |
| 34 | (a)Primingonecoat onsteel orothermetal surface with syntheticoilboundprimerofapprovedqualityincludingsmootheningsurfacesbysandpapering etc. |
| 35 | Paintingwithbest qualitysyntheticenamel paint of approvedmakeandbrandincludingsmootheningsurfacebysandpaperingetc. includingusing of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface :With super gloss (hi-gloss) (iv) Two coats (with any shade except white) |
| 36 | Frenchpolishing towoodwork includingpreparing surface (ordinary gloss)b)OnoldFrenchpolishedsurfaceincludingcompleteremovalof theoldpolish. |
| 37 | Removal of rubbish,earth etc. from theworkingsite and disposal of the same beyond thecompound, in conformity with theMunicipal / CorporationRulesfor suchdisposal, loadingintotruckandcleaning the site inall respect asperdirection of Engineer in charge |
| 38 | Carriage of Sand, Moorum and similar materials over pucca road. (For 20 km distance) Please Enable Macros to View BoQ information |