| 1 | Dismantling the existing Window/ Split type RAC machine carefully from it's original locations including, carrying & deposited to section store as instructed by EIC. |
| 2 | Supply and delivery of Non inverter wall mounted SPLIT room air conditioner having the following major specification:(a) Minimum Cooling capacity required: 18000 BTU/Hr. or Higher(b) Minimum ISEER - 3.5(c) Rated voltage-230V +/-5%, Frequency 50Hz. (d) Outdoor Ambient Temperature- 56°C.(e) Compressor type- Rotary.(f) Mini. Room Discharge air flow rate 620 CPM or higher(g) Condencer tupe-Copper condencer col(h) Minimum Tonnage required: 1.5TR or higher(i) Refrigarent- R32/R410A(j) Cordless Remote arrangement with all modernize provision of temperature setting, Fan speed option(low/medium/high), Auto swing, Air direction setting. Timer facility, Turbo operation setting, Air ventilation arrangement and others.Incl. delivery charges. (Make: O General/Mitsubishi Heavy or as per direction of EIC) with remote incl. battery and with a minimum 5-year OEM warranty on both the compressor and PCB. |
| 3 | Supply and delivery of Non inverter wall mounted SPLIT room air conditioner having the following major specification:-(a) Minimum Cooling capacity required: 24000 BTU / Hr. or Higher(b) Minimum ISEER - 3.5(c) Rated voltage-230V +/-5%, Frequency-50Hz. (d) Outdoor Ambient Temperature- 56°C.(e) Compressor type-Rotary.(f) Mini. Room Discharge air flow rate 800 CFM or higherg) Condenser type- Copper condenser coilh) Minimum Tonnage required: 2 TR or higheri) Refrigerant- R32/R410Aj) Cordless Remote arrangement with all modernized provision of temperature setting, Fan speed option(low/medium/high), Auto swing, Air direction setting.Timer facility, Turbo operation setting, Air ventilation arrangement and others.Incl. delivery charges. (Make: O General/Mitsubishi Heavy or as per direction of EIC with remote incl battery and with a minimum 5-year OEM warranty on both the compressor and PCB. |
| 4 | Installation, Testing & commissioning of 1.5/2.0 Tr. Split type AC both indoor /outdoor unit incl. S& F of 40x 40x 5 mm MS angle iron frame for installation ODU & sealing of the holes in wall created during copper pipe connection between IDU/& ODU by proper sand cement plastering & painting (both inside & outside) to match up with the original finish mending good damages to complete the installation as per direction of EIC. |
| 5 | Supply & Laying of(i) gauge copper pipe 5 /8'' prime prime 0.7 mm thickness for suction(ii) copper pipe 1 / (4'') 0.6 mm thick for discharge OEM Make with 9 mm thick thermal insulation foam nitrile/rubber/Kflex/ Accroflex with max saddling with max. 1 mtr. distance both for suction & discharge pipe and mending good the hole damages as per direction of EIC (extra length for distance of ODU & IDU exceed 3 mtr.) |
| 6 | S& Laying 4 core 2.5 sqmm PVC insulated & unarmoured copper wire (Finolex /Havells/ KEI) for 1.5/2.0 Tr. Split AC machine extra length for distance of ODU & IDU exceed 3 mtr.) with max saddling with max 1 mtr. Distance as per direction of EIC. |
| 7 | S&F of flexible PVC high quality water carrying pipe of proper size for draining water from allready installed AC to any available (nearest drain water pipe or vnear to ground level and pipe must be properly saddled with the wall incl. proper insertion of the flexible pipe to drain water pipe and sealing the entry with required materials like PVC tape, high quality scaling gum etc. as required. All these arrangement for fixing must be arranged the agency itself as per direction of EIC. |
| 8 | Supply, fitting, fixing PVC pipe approved make Schedule 80 (Medium Duty ASTMI) 17X5 MM &threaded matched with Gl pipe asper 18 1239 Part 1 with all necessary accessories special viz socket, bend union, cross, elbow, nipple, longscrew, reducing tee, short piece etc fixed with lader, tray, clamps incl. cuttingpipes, making thread, fitting, fixing etc.complete in allrespect including cost of allrecovery fittings etc. required, jointing materialsandtwo coats of painting with approved paint any position above ground maxshaddling, with max 1 mtr. distance (Payment will be made on the centre line measurements of total pipe line incl. all special. No seperate payment will be made for acessories, special payments, payment for painting will be made seperately. (a) For Exposed work (25 mm dia) |
| 9 | 1st class brick work of width 200 mm. with non-modular bricks in cement sand mortar (1:6) (b) In superstructure ground floor |
| 10 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface (i) With 1:6 cement mortar (a) 15 mm thick plaster |
| 11 | Supplying, fitting & fixing 1st quality Ceramic les in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement 2.91Kg/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m. (a) Area of each tile upto 0.09 Sqm Other than Coloured decorative including white (a) Area of each |
| 12 | S&F Timer Control Unit for single phase Split type AC machine assembled withfollowing accessories: -i)12-way SPNDB Box (L & T/Legrand/Siemens)-1 no.ii)16A/20A/25A DP MCB (Make: L&T/Legrand /Siemens ) - 1 no.iii)Digital 24 hour time switch (Make-L&T Cat no.-67DDT0 or equivalent model ofGIC/Siemens) -1no.iv)22A 3-pole power contactor (L&T: Type-MNX22 ; Cat no.-CS94980 & CS94981with 1NO + 1NC Aux. Contacts or equivalent model of Siemens/ABB)---1set.v)Melamine terminal block-2 nos.vi)LED indicating lamp (L&T: SIL R 240V)-1 no.vii) ON/OFF Push = 2 nosviii) 6 amp auto mannual toggle switch (Make- L&T or equivalent make as approvedby E.I.C)All control circuit wiring would be made by 1x1.5 sqmm FRLS stranded Cuwire (Brand approved by E.I.C) and the I/C & O/G circuit with 1x4sqmm copper wireof suitable length maintaining colour code incl taping, socketing to complete thework. |
| 13 | Supply & fixing automatic single phase AC starter of 25Amp capacity equipped withTimecheck, Voltcheck & Ampcheck and 3-digit display (Make- Electron-model no.-OPL-3+ or equivalent model of LT/Legrand as per dierction of E.I.C) to be fixedsurface enclosure as to G.S. Including S&F of 4 Module surface mounting enclosurebox(Crabtree/Legrand/Havells). |
| 14 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved byEIC), without plug top and switch, with 2 Module GI Modular type switch board withtop cover plate flushed in wall and making necy. Connections with PVC Cu wire andearth continuity wire etc. |
| 15 | Supply & Fixing 240 V, 25 A, 3 Pin Modular type plug top with indicator (Brandapproved by EIC) & necy. Connections. |
| 16 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC |
| 17 | Finishing of the PVC insulated wire ends by socketting with pin/ring type Cusockets and insulated tapes etc. including supplying sockets, tapes.(i) 4 sqmm. |
| 18 | (ii) 2.5 sqmm. |
| 19 | Special Terms & Conditions:-(i) The agency must procure the material from the Manufacture/ OEM. Authorisation certificate should be issued by the personal not below the rank of Zonal/ Regional head of that particular company, so that the standard warranty/ Support of the manufacture/OEM become applicable to the products to be delivered and installed by them.ii) Documents that authenticates such procurement from the manufacture / OEM and standard warranty support should be sent from the e- mail of the Authorise signatory of manufacture/ OEM with stating Tender Ref. No., Date of Issuance of certificate, validity of authorisation and the name, designation, contact no, email id of that authorised signatory to the Tender Inviting Authority / EIC and hard copy of it to be submitted during execution of work /submission of bill. iii) If any refurbished material is supplied and installed penal action will be taken as per existing rule. Please Enable Macros to View BoQ information |