|
| 1 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. |
| 2 | 2+4 way Enclosure [Make: Siemens/Legrand/L&T as approved by E.I.C] [D-9, D-10/13] |
| 3 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legrand/ Siemens/L&T) as per direction of EIC. ] |
| 4 | 6-32 Amps SP MCB [D-6/7] |
| 5 | 6-32 Amps FP MCB [D-6/7] |
| 6 | 6-32 Amps DP MCB [D-6/7] |
| 7 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(Gloster/Havells/Polycab/RR Kabel/Finolex) of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS. |
| 8 | i) 3 x 22/0.3 (1.5 sqmm) [ E-9/1(b)] |
| 9 | ii) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) as ECC [ E-9/1(s)] |
| 10 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc.,including supplying sockets, tapes. |
| 11 | 2.5 sq mm [9(i) / F-5] |
| 12 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works [E-16/7] |
| 13 | a) 20mm size [E-16/7(a)] |
| 14 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works [E-17/2(a)] |
| 15 | 2 Module [E-17/2(a)] |
| 16 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Legrand: Myrius/Arterior or ROMA Urban as approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (E18/9(b)) |
| 17 | Supply & Fixing 240 V 6 A Modular type switch (Legrand: Myrius/Arterior or ROMA Urban as approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required. [E-17/3(a)] |
| 18 | Supply & Fixing 240 V, 10 A, 2(Two) way Modular type switch (Legrand: Myrius/Arterior or ROMA Urban as approved by EIC) on existing GI Modular switch board having top cover plate and making necessary connections as required [6(a)/E-17] |
| 19 | Supply & fixing of 25 mm x 6 mm thick GI (Hot Dip) flat / strips for run on wall / floor with GI shaddles as required including drilling holes, bolts, nuts, washers, etc./ and mending good the damages to building works . [G-3/5d]. |
| 20 | Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run [J-1/7] |
| 21 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:.By TATA-Medium GI pipe. [G-1/2(a) |
| 22 | Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. [F-1/2(b)] |
| 23 | Supplying and fixing compression type gland and finishing the ends of following armoured stranded 'FR' PVC insulated & unsheathed copper cable (2/4 / 3.5) Core as per GS. |
| 24 | i) 4 Core 6 Sq. mm |
| 25 | ii) 3 Core 4 Sq. mm |
| 26 | Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. [D-3/ 4(a)] |
| 27 | 63 Amps (mk- L&T/Siemens as approved by EIC), |
| 28 | Fixing only bulk head ceiling fitting on wall /ceiling by screws etc. [C-2/13] |
| 29 | Supplying & Delivery 10W bulk head light fitting. (Make: Philips WT202W LED1OS NW PSU S3 PC NW PSU 53 PC / Wipro eq.) |
| 30 | Supply & fixing of Blank plate for modular board. (Make:- Legrand/Siemens) |
| 31 | Supply of 1.1 KV 4 core 6 sq mm armoured stranded 'FR' PVC insulated & unsheathed copper cable [ Make Gloster/Havells/Polycab/RR Kabel as approved by E.I.C] |
| 32 | Supply of 1.1 KV 3 core 4 sq mm armoured stranded 'FR' PVC insulated & unsheathed copper cable [ Make Gloster/Havells/Polycab/RR Kabel as approved by E.I.C] |
| 33 | Add GST @18% |
| 34 | Add LWC @1% Please Enable Macros to View BoQ information |