|
| 1 | Demolishing cement concrete by Manually Meansincluding disposal of material within 50 meters lead as per direcftion of engineer in Charge 1:3:6 or richer mix (i/C equivalent design mix) |
| 2 | Earth work in excavation by manual means in trenches for foundation, drains, pipes, cables etc. (not exceeding 1.5m in width) and for shafts, wells, cesspits amd the like not exceeding 10 sqm on plan, including getting out excavated earth and dispoal of surplus excavated earth as directed |
| 3 | Fillimg available excavated earth (excluding rock) in trenchews, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidation each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m |
| 4 | P/L Stone soiling/GSB including ramming watering as per required specification to required templete complete including all carriage complete job |
| 5 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 6 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 7 | Providing and laying upto floor v level reinforced cement concrete in kerbs, steps and the like including curing but excluding the cost of centering, shuttering, finishing and reinforcement with1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 8 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platforms |
| 11 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 coarse sand) |
| 12 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level |
| 13 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 14 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) Polyester powder coated aluminum (minimum thickness of polyester powder coated 50 microns) |
| 15 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-I type-II) in panelling fixed in aluminum doors, windowsshutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-incharge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side |
| 16 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlleddevice (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 18.2.1 W.C. pan with ISI marked white solid plastic seat and lid |
| 17 | Shutters and partitions etc with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and thw directions of Engineerin- |
| 18 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests |
| 19 | Providing and fixing 3 layer PP-R (poly Propylene Random Copolymer) pipes conforming to Is: 15801, UV stabilized and anit microbal fusion welded having thermal stability for hot and cols water supply including all pp-R plain and brass threaded polipropylene random fittings. this includes testing of joints complete as per direction of engineer in charge 16 mm including all fixtures lite T union elbow |
| 20 | C.P angle valve |
| 21 | C.P Bib Cock |
| 22 | C.P basin Mixer |
| 23 | C.P Gratting |
| 24 | I drop with lock type of approved brand and manufacture |
| 25 | PVC fitting 100 MM DA (type b) |
| 26 | PVC fitting 75 MM DA (type b) |
| 27 | PVC fitting 50 MM |
| 28 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank |
| 29 | Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position :0.075 x 0.125 of Budloo wood |
| 30 | Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.50 mm thick with zinc coating not less than 275 gram/m2 |
| 31 | Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. 0.50 mm thick with zinc coating not less than 275 gram/m2 |
| 32 | Providing and fixing plained eaves boarding. 250x32 mm (nominal size ) |
| 33 | Construction of Septic tank including earthwork in excavation upto the depth of 7feet deep and 10'-0\\" L & 8' \\"O' Wide including Brick work in 1:4mix having thickness 0'-9\\"incl laying of RCC Slab in 1:1.5:3mix of thickness 0'-5\\" including reinforcement, shuttering 50mm thick cement concrete flooring in 1:2:4 with floating coat of neat cement slurry, 15mm thick inside cement plaster in 1:3 mix with floating coat of neat cement slurry & PVC Manhole heavy duty with frame of required size & of 24 approved quality complete job |
| 34 | Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brick honey comb shaft with common burnt clay (non modular) bricks of class designation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard with rcc slab design. Completet job |
| 35 | Constructing brick masonry manhole chamber of required size in cement mortar1:4 (1 cement: 4 coarse sand), foundation concrete1:4:8 mix (1 cement: 4 coarse sand: 8 graded stone aggregate 40mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand)finished with floating coat of neat cement, & P/L 40mm flooring in 1:2:4 mix and P/F of main hole frame and C.I steel main hole cover in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) finsihed with a floating coat of neat cement complete including cost of main hole cover with frame. (internal 25 size 450x450x450mm) including all carriagesupto site of work complete. Please Enable Macros to View BoQ information |