| 1 | elefn |
| 2 | OD517182/2025-2026:Supply and fixing dust and vermin proof 3 phase syntex meter board GSMB 6535 as required. |
| 3 | OD517194/2025-2026:Supply and providing32A HRC fuse link with base and giving connection in the existing meter board |
| 4 | OD517193/2025-2026:Supply and providing 32A neutral link mounted on DMC/SMC base and giving connection in the existing meter board |
| 5 | 90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) |
| 6 | 2.1.1:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N |
| 7 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 8 | OD517188/2025-2026:Supply and fixing L&T make MUG-6 DOL starter,relay range,9-14 A ,cat NO,SS97756 COVO consisting of volt meter,/ ammeter/single phasing cum dry run preventor etc suitable for 5 HP submersible motor pumpset on existing board and giving connection as required |
| 9 | 90.14.24.17:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.2 KVAr, 3 phase, 440 V, delta connected, standard duty Metalised Poly Propylene Capacitor, Box Type, suitable for direct connection to motors. |
| 10 | OD517187/2025-2026:Supply and providing 50/5 A,75/5 A,5 VA accuracy class 3 tape wound metering CT and giving connection as required, |
| 11 | OD517201/2025-2026:Supply and providing digital multi function meter to readV,A,F,3phase accuracy class 0.5 in the existing panal board and giving connection as required |
| 12 | OD517195/2025-2026:Supply and fixing phase indication lamp (led) blue on existing board and giving connection |
| 13 | OD517196/2025-2026:Supply and fixing phase indication lamp (led) red/yellow on existing board and giving connection |
| 14 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 15 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 16 | OD517191/2025-2026:Supply and fixing Dry run cum single phasing preventor suitable for 3 phase 400V 5HP Motor on surface and giving connection as required |
| 17 | 90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm |
| 18 | 90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm |
| 19 | 90.6.10.3:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required32 mm |
| 20 | 1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm |
| 21 | 1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm |
| 22 | 1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm |
| 23 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 24 | OD517199/2025-2026:Supply and fixing 2*25*5 mmGI strip test joint for earthing |
| 25 | OD517200/2025-2026:Supply and fixing25mm*3mm GI Strip earth lead from test joint to earth plate |
| 26 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 27 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 28 | 90.12.24.2:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.4 sq mm |
| 29 | OD517198/2025-2026:Supply and providing superior quality brass bolt with hexagonal/square head ,nut and washers for the following size etc as required 25*6 mm |
| 30 | 90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm |
| 31 | OD517185/2025-2026:Supply and providing 20mmor nearest size nylon rope |
| 32 | OD519526/2025-2026:Supply ,laying and jointing of 60/63 mm column pipe of aproved make conforming to relevant standards using leack proof materials as required. |
| 33 | OD519525/2025-2026:Supply and providing stainless steel adaptor suitable for 60/63mm column pipe as required |
| 34 | 90.16.2.5:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.50 mm dia. G.I. pipe (medium class) |
| 35 | OD519577/2025-2026: Supply , installation testing and commissioning of new 5HP borewell submersible motor pumpset suitable for 150mm borewell with 5HP,3phase,50Hz,380/415V, 70/118/143 MT head, 9600/7200/5200 liter/hour discharge HRF 19/25 TEXMO or equivalent make of CRI/DECCAN/KIRLOSKER /V GUARD delivery size of 50mm or nearest size using chain pully block, leackproof materials as required and suspended on existing rope including fixing GI/column pipe as delivery pipe ,lowering upto bottom of well at required water level with necessary supports at both ends of motor pump set ,giving all electrical connections and conducting trial run at full load satisfactorily |
| 36 | OD517192/2025-2026:Supply and providing 50mm brass non return valve as required |
| 37 | OD521471/2025-2026:Supply and providing 50mm gate valve (brass) on delivery pipe as required |
| 38 | OD517197/2025-2026:Supply and providing suitable iron clamp with nut and bolt at top of the well |
| 39 | 1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A |
| 40 | 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 41 | OD517202/2025-2026:Supply and installation of 9w LED Bulb 240V AC |
| 42 | 1.24.2:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.2 way 5/6 amps switch |
| 43 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 44 | OD517190/2025-2026:Charges for preparation of KSEB Test report for submitting to the concerned KSEB Section office |
| 45 | OD521579/2025-2026:Dismantling all electrical connections, detaching the flanged joints of old GI pipe, NRV ,wheel valve, lifting old pipe with defective motor pump set from bore well to top and seperating into pump, pipe and kept at a safe place including all labour charges Please Enable Macros to View BoQ information |