| 1 | Replacement of Rocker bearing by Lifting of span by deploying extra stagging at pier cap with appropriate hydraulic jack system for span length from pier cap or providing extra plateform with cribs up to 20 mm with centralized power jack of facilitate for replacement of existing Rocker roller bearing without damaging the girder cleaning & removing damaged bearing including its staking after completion of restoration of bearings at support lowering of deck shall be carried out to its original position without causing any damage to the deck & girder as per approved method statement & standard practice,the item as per specifications & instruction of engineer incharge including cost of all material , labor and T&P etc. required for proper completion of work after the deducting the cost of old damaged material. |
| 2 | Replacement of Rocker Cum Roller bearing by Lifting of span by deploying extra stagging at pier cap with appropriate hydraulic jack system for span length from pier cap or providing extra plateform with cribs up to 20 mm with centralized power jack of facilitate for replacement of existing Rocker roller bearing without damaging the girder cleaning & removing damaged bearing including its staking after completion of restoration of bearings at support lowering of deck shall be carried out to its original position without causing any damage to the deck & girder as per approved method statement & standard practice,the item includes all labour, material ,equipments etc complete as per specifications & instruction of engineer incharge including cost of all material , labor and T&P etc. required for proper completion of work after the deducting the cost of old damaged material. |
| 3 | Lifting of Super Structure height 25 mm and Remove Dust Particles, rust by using Rust Remover after that Oiling & Greasing (Silicon) and Repositioning True Line and manner by use necessary hydraulic jacks equipment, necessary wooden packing and supports required etc complete as per specifications & instruction of engineer incharge including cost of all material , labor and T&P etc. required for proper completion of work |
| 4 | Supply and fixing of C02 type fire extinguisher 6.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 5 | Replacement of old damaged expansion joint system with new single strip seal expansion joint system with rubber seal & concrete after Removal of old expansion joint including breaking of concrete, cutting of lugs and shifting of broken material etc. includes all labour, material ,equipments etc complete as per specifications & instruction of engineer incharge after the deducting the cost of old dmaged material. |
| 6 | Painting of Railing by applying 2 coat of enemal paint including cost of material labour ,T&P etc required for proper completion of work. |
| 7 | Retro reflective Type XI DG3 HIP Sheeting pasted on 4 mm thick ACP/ACM including all 60 cm circular supported on railing jali including cost of all material , labor and T&P etc. required for proper completion of work |
| 8 | Solar Road Studs:Providing and fixing Solar Powered Road Studs (Rectangular) of size not less than 100mm x 100 mm x 10 mm or (Circular) of dia 130+/- 6mm and height 30 +/- 2mm (with 8 super bright LEDs for long visibility from distance greater than 800 m) having twin shank and body made of aluminium alloy and poly carbonate material which shall be absolutely weather resistant and strong enough to support a load of 13635 kg tested in accordance with ASTM D 4280 and water resistance as per IP 65 in accordance with IS 12063:1987, fixed to the road surface using adhesives and the procedure recommended by the manufacturer including cost of all material , labor and T&P etc. required for proper completion of work |
| 9 | Drainage Spouts complete as per drawing and Technical specification including cost of all material , labor and T&P etc. required for proper completion of work |
| 10 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 11 | Supply & fixing of 16 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 3 mm. Top dia minium 150 mm, Bottom dia 360 mm base plate 32 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 to 12 luminaries & its control gear boxes 1.5 HP power tool moter, 3 point suspension system with steel wire rope 6 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site requirement along with foundation bolts nuts, washers, anchor plates etc completee in all respect. |
| 12 | Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 170 to 200 Watt. Confirming to IP 66 protection complete in all respect. |
| 13 | Supplying and laying of 25 mm aluminum conductor PVC insulated armored sheathed cable 1100 volts grout with M.S. clamps of suitable size as directed by Engineer-in-charge, complete in all respect. Armoring shall be properly connected by clamps (Four underground laying cable shall be placed at a depth of 750 mm below ground level over a cushion of 75 m thick and all around and protected with bricks on sides and top). |
| 14 | Supplying and laying of 400 sqmm aluminum conductor PVC insulated armored sheathed cable 1100 volts grout with M.S. clamps of suitable size as directed by Engineer-in-charge, complete in all respect. Armoring shall be properly connected by clamps (Four underground laying cable shall be placed at a depth of 750 mm below ground level over a cushion of 75 m thick and all around and protected with bricks on sides and top). |
| 15 | S&F of 630 Amp. four pole change over switch on 50mm x50mm x 6mm angle iron frame, including the cost of labour,T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge. 630 Amp. four pole on 50mm x 50mm x 6mm angle iron frame |
| 16 | Jointing of L.T. 3 core PVC cable with cost of Lugs, crimping including end termination, tapping, connection etc. rejoining, if required after testing and trial on load 3x400 Smm |
| 17 | Supplying and fixing of metal clad T.P.H.R.C. type switch fuse unit of EE/L.T. and L.K./Havells/Siemens made complete with H.R.C. fuse etc. on angle iron frame complete in all respect.500 Amp |
| 18 | Supplying and fixing DP sheet steel enclosure on surface/recess along with 25/32 A 240 V \\"c\\" curve DP MCB complete with connection, testing and commissicing etc. as required. |
| 19 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface/recessed steel/PVC conduit as required 3x2.5 sq. mm |
| 20 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN ACB(65 KA,4Pole Elect draw out , Micor processer Release IPR2 ) and TPN MCCB's (Four Pole 36 KA with thermal magnatic release) Switches and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, istrument fuses, current transormer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/ DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches entry boxes shall be complete with suitable cable end boxes reverse. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above Will be provided with Amp Metre, current transfonners and selector switches etc and insurtrment fuse. The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6 mm/2mm. Cubicle type switch board shall be of cat A & B Only. |
| 21 | Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of Type XI retro- reflective sheeting, at site including all cost of material, carriage, T&P etc complete the work Please Enable Macros to View BoQ information |