| 1 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 2 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 3 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 4 | 45 cm length |
| 5 | 15 mm nominal bore |
| 6 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approvedquality conforming to IS:8931 |
| 7 | 15mm nominal bore |
| 8 | HI - WALL SPLIT SYSTEMSSupplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary C10 compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).Inverter Type - Cooling only |
| 9 | 1.5 TR with 5 Star BEE Rating |
| 10 | 2.0 TR with 5 Star BEE Rating |
| 11 | TOWER TYPE SPLIT UNITSSupplying, Installation, Testing and Commissioning of Air Cooled Floor standing Tower type split Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5 Mtr (IDU to ODU), copper power cable upto 5.5 Mtr (IDU to ODU), i/c drain pipe of suitable length and size. R-32/R-410/R-407C Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS: 1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electrotechnical Commission (IEC) 17025 standards / Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS: 1391 as required.Heating & Cooling |
| 12 | 3.3 TR BEE 4 Star Rating |
| 13 | Providing & Fixing of Powder coated ready made heavy duty out door stand for out door unit as per site requirement to the entire satisfaction of Engineer- in Charge. |
| 14 | Providing & fixing of 3 core 2.5 sqmm flexible copper wire as per ISI specifications including connections etc. of approved make Havell/ Finolex/Ecko/Polycab etc. complete in all respect at site. |
| 15 | Providing and Fixing of PVC Rigid drain Pipe complete in all respects from indoor unit to Disposal Points as directed by the E.I.C. Size ¾” including specials Diplast Or Equalivent. |
| 16 | Providing and Fixing of 22 gauge soft copper piping of size 3/8” & 5/8” or as per original manufacturer of A/C size, for Liquid & Suction sides, between indoor & outdoor units with 6 mm thick nitrile rubber insulation & protective covering for exposed whether/chasing including cost of chasing brick wall/RCC wall & repairing to original condition. The rate per meter includes cost of 1 meter each of both 3/8” & 5/8” with insulation. |
| 17 | Providing and fixing of Voltage Stablizers with copper winding input range 170-280 volts nominal output 230 Volts +/- 10% complete in all respect. Make: Deol, Jewel, V-Guard or Equivalent |
| 18 | 5 KVA Capacity |
| 19 | Providing and fixing water cooler full body stainless steel SS 304 with non CFC hermeticaly sealed reciprocating/ rotary type compressor complete in all respect 380-400 of approved make |
| 20 | P/F of Hi Flow water Filter-cum-Purifier including installation charges 3 Ltr/Minute. Make Aqua guardrd/Kent/Usha/Pure-it |
| 21 | Providing and fixing of MCCB 2 pole 32 Amp single phase compplete in all respect to the entire statisfaction of EIC as per approved make list. |
| 22 | Providing and fixing of PVC trunking batten copper pipe, drain pipe and wire in case exposed on walll. |
| 23 | Providing core cutting in brick and RCC wall by means of mechanioical equipement as direction by EIC Please Enable Macros to View BoQ information |